Lothar R. Schad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Lothar R. Schad has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Frank Gerrit Zöllner
Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
5 shared publications - Efe Ilicak
Computer Assisted Clinical Medicine, Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany; National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
3 shared publications - Jascha Zapp
Computer Assisted Clinical Medicine, Medical Faculty Mannheim Heidelberg University Mannheim Germany
3 shared publications - Safa Ozdemir
Computer Assisted Clinical Medicine, Medical Faculty Mannheim Heidelberg University Mannheim Germany
3 shared publications - Dennis Kleimaier
Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany
2 shared publications - Michaela A. U. Hoesl
Computer Assisted Clinical Medicine, Heidelberg University, 68167 Mannheim, Germany
2 shared publications
Latest Publications
- Open Access
- 3 December 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (4) , 1567-1575
Feasibility of undersampled spiral trajectories in MREPT for fast conductivity imaging
Purpose: To investigate spiral‐based imaging including trajectories with undersampling as a fast and robust alternative for phase‐based magnetic resonance electrical properties tomography (MREPT) techniques.Methods: Spiral trajectories with various undersampling ratios were prescribed to acquire images from an experimental phantom and a healthy volunteer at 3T. The non‐Cartesian acquisitions were reconstructed using SPIRiT, and conductivity maps were derived using phase‐based cr‐MREPT. The resulting maps were compared between different sampling trajectories. Additionally, a conductivity map was obtained using a Cartesian balanced SSFP acquisition from the volunteer to comparatively demonstrate the robustness of the proposed method.Results: The phantom and volunteer results illustrate the benefits of the spiral acquisitions. Specifically, undersampled spiral acquisitions display improved robustness against field inhomogeneity artifacts and lowered SD values with shortened readout times. Furthermore, average of conductivity values measured for the cerebrospinal fluid with the spiral acquisitions were 1.703 S/m, indicating a close agreement with the theoretical values of 1.794 S/m.Conclusion: A spiral‐based acquisition framework for conductivity imaging with and without undersampling is presented. Overall, spiral‐based acquisitions improved robustness against field inhomogeneity artifacts, while achieving whole head coverage with multiple averages in less than a minute.
- 3 December 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (4) , 1567-1575
Open AccessFeasibility of undersampled spiral trajectories in MREPT for fast conductivity imaging
Purpose: To investigate spiral‐based imaging including trajectories with undersampling as a fast and robust alternative for phase‐based magnetic resonance electrical properties tomography (MREPT) techniques.Methods: Spiral trajectories with various undersampling ratios were prescribed to acquire images from an experimental phantom and a healthy volunteer at 3T. The non‐Cartesian acquisitions were reconstructed using SPIRiT, and conductivity maps were derived using phase‐based cr‐MREPT. The resulting maps were compared between different sampling trajectories. Additionally, a conductivity map was obtained using a Cartesian balanced SSFP acquisition from the volunteer to comparatively demonstrate the robustness of the proposed method.Results: The phantom and volunteer results illustrate the benefits of the spiral acquisitions. Specifically, undersampled spiral acquisitions display improved robustness against field inhomogeneity artifacts and lowered SD values with shortened readout times. Furthermore, average of conductivity values measured for the cerebrospinal fluid with the spiral acquisitions were 1.703 S/m, indicating a close agreement with the theoretical values of 1.794 S/m.Conclusion: A spiral‐based acquisition framework for conductivity imaging with and without undersampling is presented. Overall, spiral‐based acquisitions improved robustness against field inhomogeneity artifacts, while achieving whole head coverage with multiple averages in less than a minute.
- Open Access
- 29 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (2) , 761-769
Dynamic mode decomposition of dynamic MRI for assessment of pulmonary ventilation and perfusion
Purpose: To introduce dynamic mode decomposition (DMD) as a robust alternative for the assessment of pulmonary functional information from dynamic non‐contrast‐enhanced acquisitions.Methods: Pulmonary fractional ventilation and normalized perfusion maps were obtained using DMD from simulated phantoms as well as in vivo dynamic acquisitions of healthy volunteers at 1.5T. The performance of DMD was compared with conventional Fourier decomposition (FD) and matrix pencil (MP) methods in estimating functional map values. The proposed method was evaluated based on estimated signal amplitude in functional maps across varying number of measurements.Results: Quantitative assessments performed on phantoms and in vivo measurements indicate that DMD is capable of successfully obtaining pulmonary functional maps. Specifically, compared to FD and MP methods, DMD is able to reduce variations in estimated amplitudes across different number of measurements. This improvement is evident in the fractional ventilation and normalized perfusion maps obtain from phantom simulations with frequency variations and noise, as well as in the maps obtained from in vivo measurements.Conclusions: A robust method for accurately estimating pulmonary ventilation and perfusion related signal changes in dynamic acquisitions is presented. The proposed method uses DMD to obtain functional maps reliably, while reducing amplitude variations caused by differences in number of measurements.
- 29 March 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (2) , 761-769
Open AccessDynamic mode decomposition of dynamic MRI for assessment of pulmonary ventilation and perfusion
Purpose: To introduce dynamic mode decomposition (DMD) as a robust alternative for the assessment of pulmonary functional information from dynamic non‐contrast‐enhanced acquisitions.Methods: Pulmonary fractional ventilation and normalized perfusion maps were obtained using DMD from simulated phantoms as well as in vivo dynamic acquisitions of healthy volunteers at 1.5T. The performance of DMD was compared with conventional Fourier decomposition (FD) and matrix pencil (MP) methods in estimating functional map values. The proposed method was evaluated based on estimated signal amplitude in functional maps across varying number of measurements.Results: Quantitative assessments performed on phantoms and in vivo measurements indicate that DMD is capable of successfully obtaining pulmonary functional maps. Specifically, compared to FD and MP methods, DMD is able to reduce variations in estimated amplitudes across different number of measurements. This improvement is evident in the fractional ventilation and normalized perfusion maps obtain from phantom simulations with frequency variations and noise, as well as in the maps obtained from in vivo measurements.Conclusions: A robust method for accurately estimating pulmonary ventilation and perfusion related signal changes in dynamic acquisitions is presented. The proposed method uses DMD to obtain functional maps reliably, while reducing amplitude variations caused by differences in number of measurements.
- Open Access
- 24 May 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (4) , 1764-1774
Phase‐cycled balanced SSFP imaging for non‐contrast‐enhanced functional lung imaging
Purpose: To introduce phase‐cycled balanced SSFP (bSSFP) acquisition as an alternative in Fourier decomposition MRI for improved robustness against field inhomogeneities.Methods: Series 2D dynamic lung images were acquired in 5 healthy volunteers at 1.5 T and 3 T using bSSFP sequence with multiple RF phase increments and compared with conventional single RF phase increment acquisitions. The approach was evaluated based on functional map homogeneity analysis, while ensuring image and functional map quality by means of SNR and contrast‐to‐noise ratio analyses.Results: At both field strengths, functional maps obtained with phase‐cycled acquisitions displayed improved robustness against local signal losses compared with single‐phase acquisitions. The coefficient of variation (mean ± SD, across volunteers) measured in the ventilation maps resulted in 29.7 ± 2.6 at 1.5 T and 37.5 ± 3.1 at 3 T for phase‐cycled acquisitions, compared with 39.9 ± 5.2 at 1.5 T and 49.5 ± 3.7 at 3 T for single‐phase acquisitions, indicating a significant improvement () in ventilation map homogeneity.Conclusions: Phase‐cycled bSSFP acquisitions improve robustness against field inhomogeneity artifacts and significantly improve ventilation map homogeneity at both field strengths. As such, phase‐cycled bSSFP may serve as a robust alternative in lung function assessments.
- 24 May 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (4) , 1764-1774
Open AccessPhase‐cycled balanced SSFP imaging for non‐contrast‐enhanced functional lung imaging
Purpose: To introduce phase‐cycled balanced SSFP (bSSFP) acquisition as an alternative in Fourier decomposition MRI for improved robustness against field inhomogeneities.Methods: Series 2D dynamic lung images were acquired in 5 healthy volunteers at 1.5 T and 3 T using bSSFP sequence with multiple RF phase increments and compared with conventional single RF phase increment acquisitions. The approach was evaluated based on functional map homogeneity analysis, while ensuring image and functional map quality by means of SNR and contrast‐to‐noise ratio analyses.Results: At both field strengths, functional maps obtained with phase‐cycled acquisitions displayed improved robustness against local signal losses compared with single‐phase acquisitions. The coefficient of variation (mean ± SD, across volunteers) measured in the ventilation maps resulted in 29.7 ± 2.6 at 1.5 T and 37.5 ± 3.1 at 3 T for phase‐cycled acquisitions, compared with 39.9 ± 5.2 at 1.5 T and 49.5 ± 3.7 at 3 T for single‐phase acquisitions, indicating a significant improvement () in ventilation map homogeneity.Conclusions: Phase‐cycled bSSFP acquisitions improve robustness against field inhomogeneity artifacts and significantly improve ventilation map homogeneity at both field strengths. As such, phase‐cycled bSSFP may serve as a robust alternative in lung function assessments.
- 1 April 2021
- Published by Elsevier in Multiple Sclerosis and Related Disorders
- Vol. 49, 102752
Diffusely appearing white matter in multiple sclerosis: Insights from sodium (23Na) MRI
- 1 April 2021
- Published by Elsevier in Multiple Sclerosis and Related Disorders
- Vol. 49, 102752
Diffusely appearing white matter in multiple sclerosis: Insights from sodium (23Na) MRI
- Open Access
- 12 July 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (10) , e4367
Protein conformational changes affect the sodium triple‐quantum MR signal
The aim of this study was to investigate possible sodium triple‐quantum (TQ) signal dependence on pH variation and protein unfolding which may happen in vivo. The model system, composed of bovine serum albumin (BSA), was investigated over a wide pH range of 0.70 to 13.05 and during urea‐induced unfolding. In both experimental series, the sodium and BSA concentration were kept constant so that TQ signal changes solely arose from an environmental change. The experiments were performed using unique potential to detect weak TQ signals by implementing a TQ time proportional phase increment pulse sequence. At a pH of 0.70, in which case the effect of the negatively charged groups was minimized, the minimum TQ percentage relative to single‐quantum of 1.34% ± 0.05% was found. An increase of the pH up to 13.05 resulted in an increase of the sodium TQ signal by 225%. Urea‐induced unfolding of BSA, without changes in pH, led to a smaller increase in the sodium TQ signal of up to 40%. The state of BSA unfolding was verified by fluorescence microscopy. Results of both experiments were well fitted by sigmoid functions. Both TQ signal increases were in agreement with an increase of the availability of negatively charged groups. The results point to vital contributions of the biochemical environment to the TQ MR signals. The sodium TQ signal in vivo could be a valuable biomarker of cell viability, and therefore possible effects of pH and protein unfolding need to be considered for a proper interpretation of changes in sodium TQ signals.
- 12 July 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (10) , e4367
Open AccessProtein conformational changes affect the sodium triple‐quantum MR signal
The aim of this study was to investigate possible sodium triple‐quantum (TQ) signal dependence on pH variation and protein unfolding which may happen in vivo. The model system, composed of bovine serum albumin (BSA), was investigated over a wide pH range of 0.70 to 13.05 and during urea‐induced unfolding. In both experimental series, the sodium and BSA concentration were kept constant so that TQ signal changes solely arose from an environmental change. The experiments were performed using unique potential to detect weak TQ signals by implementing a TQ time proportional phase increment pulse sequence. At a pH of 0.70, in which case the effect of the negatively charged groups was minimized, the minimum TQ percentage relative to single‐quantum of 1.34% ± 0.05% was found. An increase of the pH up to 13.05 resulted in an increase of the sodium TQ signal by 225%. Urea‐induced unfolding of BSA, without changes in pH, led to a smaller increase in the sodium TQ signal of up to 40%. The state of BSA unfolding was verified by fluorescence microscopy. Results of both experiments were well fitted by sigmoid functions. Both TQ signal increases were in agreement with an increase of the availability of negatively charged groups. The results point to vital contributions of the biochemical environment to the TQ MR signals. The sodium TQ signal in vivo could be a valuable biomarker of cell viability, and therefore possible effects of pH and protein unfolding need to be considered for a proper interpretation of changes in sodium TQ signals.
- Open Access
- 28 May 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (5) , 2412-2428
Efficient 23Na triple‐quantum signal imaging on clinical scanners: Cartesian imaging of single and triple‐quantum 23Na (CRISTINA)
Purpose: To capture the multiquantum coherence (MQC) 23Na signal. Different phase‐cycling options and sequences are compared in a unified theoretical layout, and a novel sequence is developed.Methods: An open source simulation overview is provided with graphical explanations to facilitate MQC understanding and access to techniques. Biases such as B0 inhomogeneity and stimulated echo signal were simulated for 4 different phase‐cycling options previously described. Considerations for efficiency and accuracy lead to the implementation of a 2D Cartesian single and triple quantum imaging of sodium (CRISTINA) sequence employing two 6‐step cycles in combination with a multi‐echo readout. CRISTINA was compared to simultaneous single‐quantum and triple‐quantum‐filtered MRI of sodium (SISTINA) under strong static magnetic gradient. CRISTINA capabilities were assessed on 8 × 60 mL, 0% to 5% agarose phantom with 50 to 154 mM 23Na concentration at 7 T. CRISTINA was demonstrated subsequently in vivo in the brain.Results: Simulation of B0 inhomogeneity showed severe signal dropout, which can lead to erroneous MQC measurement. Stimulated echo signal was highest at the time of triple‐quantum coherences signal maximum. However, stimulated echo signal is separated by Fourier Transform as an offset and did not interfere with MQC signals. The multi‐echo readout enabled capturing both single‐quantum coherences and triple‐quantum coherences signal evolution at once. Signal combination of 2 phase‐cycles with a corresponding B0 map was found to recover the signal optimally. Experimental results confirm and complement the simulations.Conclusion: Considerations for efficient MQC measurements, most importantly avoiding B0 signal loss, led to the design of CRISTINA. CRISTINA captures triple‐quantum coherences and single‐quantum coherences signal evolution to provide complete sodium signal characterization including fast, slow, MQC amplitudes, and sodium concentration.
- 28 May 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (5) , 2412-2428
Open AccessEfficient 23Na triple‐quantum signal imaging on clinical scanners: Cartesian imaging of single and triple‐quantum 23Na (CRISTINA)
Purpose: To capture the multiquantum coherence (MQC) 23Na signal. Different phase‐cycling options and sequences are compared in a unified theoretical layout, and a novel sequence is developed.Methods: An open source simulation overview is provided with graphical explanations to facilitate MQC understanding and access to techniques. Biases such as B0 inhomogeneity and stimulated echo signal were simulated for 4 different phase‐cycling options previously described. Considerations for efficiency and accuracy lead to the implementation of a 2D Cartesian single and triple quantum imaging of sodium (CRISTINA) sequence employing two 6‐step cycles in combination with a multi‐echo readout. CRISTINA was compared to simultaneous single‐quantum and triple‐quantum‐filtered MRI of sodium (SISTINA) under strong static magnetic gradient. CRISTINA capabilities were assessed on 8 × 60 mL, 0% to 5% agarose phantom with 50 to 154 mM 23Na concentration at 7 T. CRISTINA was demonstrated subsequently in vivo in the brain.Results: Simulation of B0 inhomogeneity showed severe signal dropout, which can lead to erroneous MQC measurement. Stimulated echo signal was highest at the time of triple‐quantum coherences signal maximum. However, stimulated echo signal is separated by Fourier Transform as an offset and did not interfere with MQC signals. The multi‐echo readout enabled capturing both single‐quantum coherences and triple‐quantum coherences signal evolution at once. Signal combination of 2 phase‐cycles with a corresponding B0 map was found to recover the signal optimally. Experimental results confirm and complement the simulations.Conclusion: Considerations for efficient MQC measurements, most importantly avoiding B0 signal loss, led to the design of CRISTINA. CRISTINA captures triple‐quantum coherences and single‐quantum coherences signal evolution to provide complete sodium signal characterization including fast, slow, MQC amplitudes, and sodium concentration.
- 17 May 2019
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 51 (2) , 355-376
X‐nuclei imaging: Current state, technical challenges, and future directions
1H imaging is concerned with contrast generation among anatomically distinct soft tissues. X‐nuclei imaging, on the other hand, aims to reveal the underlying changes in the physiological processes on a cellular level. Advanced clinical MR hardware systems improved1H image quality and simultaneously enabled X‐nuclei imaging. Adaptation of1H methods and optimization of both sequence design and postprocessing protocols launched X‐nuclei imaging past feasibility studies and into clinical studies. This review outlines the current state of X‐nuclei MRI, with the focus on23Na,35Cl,39K, and17O. Currently, various aspects of technical challenges limit the possibilities of clinical X‐nuclei MRI applications. To address these challenges, quintessential physical and technical concepts behind different applications are presented, and the advantages and drawbacks are delineated. The working process for methods such as quantification and multiquantum imaging is shown step‐by‐step. Clinical examples are provided to underline the potential value of X‐nuclei imaging in multifaceted areas of application. In conclusion, the scope of the latest technical advance is outlined, and suggestions to overcome the most fundamental hurdles on the way into clinical routine by leveraging the full potential of X‐nuclei imaging are presented.Level of Evidence:1Technical Efficacy Stage:3J. Magn. Reson. Imaging 2020;51:355–376.
- 17 May 2019
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 51 (2) , 355-376
X‐nuclei imaging: Current state, technical challenges, and future directions
1H imaging is concerned with contrast generation among anatomically distinct soft tissues. X‐nuclei imaging, on the other hand, aims to reveal the underlying changes in the physiological processes on a cellular level. Advanced clinical MR hardware systems improved1H image quality and simultaneously enabled X‐nuclei imaging. Adaptation of1H methods and optimization of both sequence design and postprocessing protocols launched X‐nuclei imaging past feasibility studies and into clinical studies. This review outlines the current state of X‐nuclei MRI, with the focus on23Na,35Cl,39K, and17O. Currently, various aspects of technical challenges limit the possibilities of clinical X‐nuclei MRI applications. To address these challenges, quintessential physical and technical concepts behind different applications are presented, and the advantages and drawbacks are delineated. The working process for methods such as quantification and multiquantum imaging is shown step‐by‐step. Clinical examples are provided to underline the potential value of X‐nuclei imaging in multifaceted areas of application. In conclusion, the scope of the latest technical advance is outlined, and suggestions to overcome the most fundamental hurdles on the way into clinical routine by leveraging the full potential of X‐nuclei imaging are presented.Level of Evidence:1Technical Efficacy Stage:3J. Magn. Reson. Imaging 2020;51:355–376.
- 1 May 2017
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 278, 39-50
1D and 2D diffusion pore imaging on a preclinical MR system using adaptive rephasing: Feasibility and pulse sequence comparison
- 1 May 2017
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 278, 39-50
1D and 2D diffusion pore imaging on a preclinical MR system using adaptive rephasing: Feasibility and pulse sequence comparison
- 20 July 2014
- Published by Springer Nature in European Radiology
- Vol. 24 (10) , 2427-2434
High temporal versus high spatial resolution in MR quantitative pulmonary perfusion imaging of two-year old children after congenital diaphragmatic hernia repair
Congenital diaphragmatic hernia (CDH) leads to lung hypoplasia. Using dynamic contrast-enhanced (DCE) MR imaging, lung perfusion can be quantified. As MR perfusion values depend on temporal resolution, we compared two protocols to investigate whether ipsilateral lung perfusion is impaired after CDH, whether there are protocol-dependent differences, and which protocol is preferred. DCE-MRI was performed in 36 2-year old children after CDH on a 3 T MRI system; protocol A (n = 18) based on a high spatial (3.0 s; voxel: 1.25 mm3) and protocol B (n = 18) on a high temporal resolution (1.5 s; voxel: 2 mm3). Pulmonary blood flow (PBF), pulmonary blood volume (PBV), mean transit time (MTT), and peak-contrast-to-noise-ratio (PCNR) were quantified. PBF was reduced ipsilaterally, with ipsilateral PBF of 45 ± 26 ml/100 ml/min to contralateral PBF of 63 ± 28 ml/100 ml/min (p = 0.0016) for protocol A; and for protocol B, side differences were equivalent (ipsilateral PBF = 62 ± 24 vs. contralateral PBF = 85 ± 30 ml/100 ml/min; p = 0.0034). PCNR was higher for protocol B (30 ± 18 vs. 20 ± 9; p = 0.0294). Protocol B showed higher values of PBF in comparison to protocol A (p always Quantitative lung perfusion parameters depend on temporal and spatial resolution. • Reduction of lung perfusion in CDH can be measured with different MR protocols. • Temporal resolution of 1.5 s with spatial resolution of 2 mm 3 is suitable.
- 20 July 2014
- Published by Springer Nature in European Radiology
- Vol. 24 (10) , 2427-2434
High temporal versus high spatial resolution in MR quantitative pulmonary perfusion imaging of two-year old children after congenital diaphragmatic hernia repair
Congenital diaphragmatic hernia (CDH) leads to lung hypoplasia. Using dynamic contrast-enhanced (DCE) MR imaging, lung perfusion can be quantified. As MR perfusion values depend on temporal resolution, we compared two protocols to investigate whether ipsilateral lung perfusion is impaired after CDH, whether there are protocol-dependent differences, and which protocol is preferred. DCE-MRI was performed in 36 2-year old children after CDH on a 3 T MRI system; protocol A (n = 18) based on a high spatial (3.0 s; voxel: 1.25 mm3) and protocol B (n = 18) on a high temporal resolution (1.5 s; voxel: 2 mm3). Pulmonary blood flow (PBF), pulmonary blood volume (PBV), mean transit time (MTT), and peak-contrast-to-noise-ratio (PCNR) were quantified. PBF was reduced ipsilaterally, with ipsilateral PBF of 45 ± 26 ml/100 ml/min to contralateral PBF of 63 ± 28 ml/100 ml/min (p = 0.0016) for protocol A; and for protocol B, side differences were equivalent (ipsilateral PBF = 62 ± 24 vs. contralateral PBF = 85 ± 30 ml/100 ml/min; p = 0.0034). PCNR was higher for protocol B (30 ± 18 vs. 20 ± 9; p = 0.0294). Protocol B showed higher values of PBF in comparison to protocol A (p always Quantitative lung perfusion parameters depend on temporal and spatial resolution. • Reduction of lung perfusion in CDH can be measured with different MR protocols. • Temporal resolution of 1.5 s with spatial resolution of 2 mm 3 is suitable.
- 16 July 2010
- Published by Wiley in NMR in Biomedicine
- Vol. 23 (6) , 592-600
In vivo chlorine‐35, sodium‐23 and proton magnetic resonance imaging of the rat brain
In this study we demonstrate the feasibility of combined chlorine‐35, sodium‐23 and proton magnetic resonance imaging (MRI) at 9.4 Tesla, and present the first in vivo chlorine‐35 images obtained by means of MRI. With the experimental setup used in this study all measurements could be done in one session without changing the setup or moving the subject. The multinuclear measurement requires a total measurement time of 2 h and provides morphological (protons) and physiological (sodium‐23, chlorine‐35) information in one scanning session. Chlorine‐35, sodium‐23 and high resolution proton images were acquired from a phantom, a healthy rat and from a rat displaying a focal cerebral infarction. Compared to the healthy tissue a signal enhancement of a factor of 2.2 ± 0.2 in the chlorine‐35 and a factor of 2.9 ± 0.6 in the sodium‐23 images is observed in the areas of infarction. Exemplary unlocalized measurement of the in vivo longitudinal and transversal relaxation time of chlorine‐35 in a healthy rat showed multi‐exponential behaviour. A biexponential fit revealed a fast and a slow relaxing component with T1,a = (1.7 ± 0.4) ms, T1,b = (25.1 ± 1.4) ms, amplitudes of A = 0.26 ± 0.02, (1–A) = 0.74 ± 0.02 and T2,a = (1.3 ± 0.1) ms, T2,b = (11.8 ± 1.1) ms, A = 0.64 ± 0.02, (1–A) = 0.36 ± 0.02. Combined proton, sodium‐23 and chlorine‐35 MRI may provide a new approach for non‐invasive studies of ionic regulatory processes under physiological and pathological conditions in vivo. Copyright © 2010 John Wiley & Sons, Ltd.
- 16 July 2010
- Published by Wiley in NMR in Biomedicine
- Vol. 23 (6) , 592-600
In vivo chlorine‐35, sodium‐23 and proton magnetic resonance imaging of the rat brain
In this study we demonstrate the feasibility of combined chlorine‐35, sodium‐23 and proton magnetic resonance imaging (MRI) at 9.4 Tesla, and present the first in vivo chlorine‐35 images obtained by means of MRI. With the experimental setup used in this study all measurements could be done in one session without changing the setup or moving the subject. The multinuclear measurement requires a total measurement time of 2 h and provides morphological (protons) and physiological (sodium‐23, chlorine‐35) information in one scanning session. Chlorine‐35, sodium‐23 and high resolution proton images were acquired from a phantom, a healthy rat and from a rat displaying a focal cerebral infarction. Compared to the healthy tissue a signal enhancement of a factor of 2.2 ± 0.2 in the chlorine‐35 and a factor of 2.9 ± 0.6 in the sodium‐23 images is observed in the areas of infarction. Exemplary unlocalized measurement of the in vivo longitudinal and transversal relaxation time of chlorine‐35 in a healthy rat showed multi‐exponential behaviour. A biexponential fit revealed a fast and a slow relaxing component with T1,a = (1.7 ± 0.4) ms, T1,b = (25.1 ± 1.4) ms, amplitudes of A = 0.26 ± 0.02, (1–A) = 0.74 ± 0.02 and T2,a = (1.3 ± 0.1) ms, T2,b = (11.8 ± 1.1) ms, A = 0.64 ± 0.02, (1–A) = 0.36 ± 0.02. Combined proton, sodium‐23 and chlorine‐35 MRI may provide a new approach for non‐invasive studies of ionic regulatory processes under physiological and pathological conditions in vivo. Copyright © 2010 John Wiley & Sons, Ltd.