CLChian Yong Liu

Chian Yong Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chian Yong Liu has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Opinions and Attitudes of Anaesthesiology and Critical Care Doctors Regarding Family Presence During Resuscitation in Two Major Hospitals in Kuala Lumpur, Malaysia

    by Yu Xin Tai, Chian Yong Liu, Ismail Tan, Qurratu Aini Musthafa

    Family presence during resuscitation (FPDR) remains controversial despite growing acceptance in Western countries. This study explored Malaysian doctors' views on FPDR within critical care environments. A cross-sectional survey of 169 doctors working in critical care units of Hospital Kuala Lumpur (HKL) and Hospital Canselor Tuanku Muhriz UKM (HCTM) was conducted between October 2023 and January 2024. Data analysis included descriptive statistics, chi-square tests, simple logistic regression, and multivariable logistic regression. A total of 27.7% (n = 44) of respondents agreed to allow FPDR, with no significant association found between acceptance and demographic or professional characteristics. Major concerns included increased staff stress, potential misinterpretation of procedures, space limitations, privacy violations, emotional distress for families, difficulty stopping futile resuscitation, and litigation risks. Healthcare providers recognised FPDR's educational value and potential to promote professionalism. Opinions were divided on FPDR's impact on family participation, support, and bonding. Most did not believe FPDR reduces family anxiety. Respondents who have had personal FPDR experience were more likely to support it (OR: 8.823 (95% CI: 3.670 - 21.212), p < 0.001). This study revealed that the majority of respondents working in critical care settings in HKL and HCTM are opposed to FPDR. Their reluctance is due to the perceived negative effects of FPDR. Experience in FPDR significantly influenced the willingness to practise FPDR.


  • PCA ketamine–morphine versus PCA morphine as post-operative analgesia in colorectal surgery

    by Nurul Akasya Adnan, Chian Yong Liu, Nita Salina Abdullah

    Objective: Ketamine has undergone a recent resurgence of interest as an opioid-sparing agent in pain management. The purpose of this study is to evaluate the effectiveness of patient-controlled analgesia (PCA) ketamine–morphine in comparison to conventional PCA morphine alone as post-operative analgesia in colorectal surgery patients. Design: Double-blind, randomized, controlled study. Setting: This study was conducted at a single, tertiary hospital. Patients: Sixty patients who underwent elective colorectal surgery were randomly assigned into two groups. Interventions: Group A received PCA ketamine–morphine 0.5:0.5 mg mL–1, while Group B received PCA morphine 1 mg mL–1 as post-operative analgesia. Main outcome measures: Patients’ pain scores, total PCA demands, cumulative morphine consumption, side effects, and their overall satisfaction score were recorded and analyzed. Results: Overall, there was no significant difference in pain score in both groups, except at 24-hour intervals where Group A had significantly lower mean pain score at rest (1.10 ± 1.37 vs 2.10 ± 1.65, p = 0.017). Total PCA demands were comparable between both groups. Cumulative morphine consumptions however were significantly lower in Group A at all intervals with 24.7 ± 15.2 vs 48.9 ± 30.4 mg (p < 0.001) at 24-hour interval and 38.3 ± 22.4 vs 77.8 ± 46.3 mg (p = 0.001) at 48-hour interval. There was no significant difference in the incidence of side effects and overall satisfaction score in both groups. Conclusions: PCA ketamine–morphine was as effective as PCA morphine as post-operative analgesia in colorectal surgery, with comparable pain scores, PCA demands, side effects, and significant reduction in morphine consumption.


  • Open Access

    Advancing Anaesthetist Rostering Quality: A Practical Approach Toward Fairness and Efficiency

    by Norizal Abdullah, Masri Ayob, Meng Chun Lam, Nasser R. Sabar, Graham Kendall, Liu Chian Yong

    The Anaesthetist Rostering Problem (ARP) presents significant challenges in healthcare management due to complex constraints and regulations. Existing models for the ARP often fail to address the complexities of real-world hospital environments, particularly in integrating monthly and weekly schedules across multiple locations. This study addresses the key question: How can we develop anaesthetist rosters that improve both staff fairness and operational efficiency while meeting complex hospital requirements? To address this challenge, we propose a novel mixed-integer linear programming model with updated constraints, parameters, and an enhanced evaluation function. We implemented the model at Hospital Canselor Tuanku Muhriz (HCTM), Malaysia, to handle various shift types across multiple locations for both monthly and weekly rosters. The proposed model optimises the roster by satisfying mandatory constraints first (such as legal requirements), and then minimising soft constraint violations, such as employee preferences, through iterative refinement. The evaluation function assesses roster quality by minimising penalties for soft constraint violations. We modified the evaluation function and constraints to accommodate HCTM’s specific shift patterns and rest requirements, enhancing fairness, flexibility, and workload distribution. The model reduced penalties by 69.57% for monthly rosters and 64.37% for weekly rosters compared to manual scheduling. Statistical analysis proved significant enhancement in monthly rosters and weekly rosters. The model improves workload fairness and scheduling efficiency, bridging theoretical models and practical applications. It contributes to healthcare workforce management by offering better resource allocation and increased staff satisfaction.


  • Open Access

    An Improved Saturation Degree-Based Constructive Heuristic for Master Surgery Scheduling Problem: Case Study

    by Mohamad Khairulamirin Md. Razali, Abdul Hadi Abd Rahman, Masri Ayob, Razman Jarmin, Liu Chian Yong, Muhammad Maaya, Azarinah Izaham, Raha Abdul Rahman

    The Master Surgery Scheduling Problem (MSSP) can be described as a timetabling problem involving assigning surgery groups to operating theatre (OT) time slots. Previous MSSP optimization models considered throughput, waiting measures, resource utilization, costs, and schedule assignment objectives, neglecting consecutive days assignment preferences and surgical equipment-sharing limitations. Furthermore, previous works utilize greedy constructive heuristics to produce solutions, which increases quality but decreases feasibility. Our prior study demonstrated that the saturation degree heuristic enhances feasibility by considering assignment difficulty during event selection. However, its impact on solution quality remained unexplored. Therefore, this study proposes an improved saturation degree-based constructive heuristic that integrates objective function value for event selection to increase both quality and feasibility. The algorithm sorts surgery groups based on unit scores , prioritizing lower assignment difficulty and higher objective value. The highest-scoring group is assigned to its feasible slot with the highest slot score , following similar goals. In case of no feasible slots, the repair mechanism vacates the highest swap score slot, assessing the impact on quality and feasibility. A new mathematical model is also formulated, incorporating novel objectives regarding consecutive days assignment preference and surgical equipment-sharing limitations. Validated using real-world data from Hospital Canselor Tuanku Muhriz, the proposed algorithm is evaluated considering repair mechanism usage for feasibility and objective function value for quality. The algorithm is benchmarked against greedy, random, regret-based, and saturation degree-based constructive heuristics. Our algorithm achieved a 14.63% improvement in feasibility compared to the original variant. Its objective function value is over two times better than the closest competitor and 2.6 times superior to the original variant. Comparison with the hospital’s actual plan demonstrates competitive objective function value and a more balanced waiting time distribution among surgical groups. Our study showcases that a saturation degree-based constructive heuristic considering objective function value has increased solution quality while maintaining feasibility.


  • Open Access

    Performance of Point-of-Care Ultrasonography in Confirming Feeding Tube Placement in Mechanically Ventilated Patients

    by Thanalachumy Ragunathan, Rufinah Teo, Aliza Mohamad Yusof, Siti Nidzwani Mohamad Mahdi, Azarinah Izaham, Chian Yong Liu, Maryam Budiman, Syarifah Noor Nazihah Sayed Masri, Raha Abdul Rahman

    Background: A feeding tube (FT) is routinely placed in critically ill patients, and its correct placement is confirmed with a chest X-ray (CXR), which is considered the gold standard. This study evaluated the diagnostic accuracy of ultrasonography (USG) in verifying FT placement compared to a CXR in an intensive care unit (ICU). Method: This was a prospective single-blind study conducted on patients admitted to the ICU of a tertiary hospital in Malaysia. The FT placements were verified through a fogging test and USG at the neck and subxiphoid points. The results of confirmation of FT placement through USG were compared with those obtained using CXRs. Results: A total of 80 patients were included in this study. The FT positions were accurately confirmed by overall USG assessments in 71 patients. The percentage of FT placements correctly identified by neck USG was 97.5%, while the percentage of those identified by epigastric USG was 75%. The corresponding patients’ CXRs confirmed correct FT placement in 76 patients. The overall USG assessment had a sensitivity of 92.11% and specificity of 75%, a positive predictive value of 98.59%, and a negative predictive value of 33.33%. The USG findings also showed a significant association between FT size and BMI. FTs with a size of 14Fr were better visualized (p = 0.008), and negative USG findings had a significantly higher BMI (p < 0.001). Conclusion: USG is a simple, safe, and reliable bedside assessment that offers relatively high sensitivity in confirming correct FT placement in critically ill patients.


  • Open Access

    Clinical Performance Comparison of LMA Protector™ Cuff Pilot™ and LMA Supreme™ When Used in Anesthetized, Non-paralyzed Patients

    by Weng Ken Chan, Chian Yong Liu

    The advancement of supraglottic airways (SGAs) has eased airway management, especially for anesthetists. There were functional improvements implemented to the newer SGA. We aim to assess the clinical performance of laryngeal mask airway (LMA) Protector™ Cuff Pilot™ (Teleflex Inc., Wayne, Pennsylvania, USA) against LMA Supreme™ (Teleflex Inc., Wayne, Pennsylvania, USA), in terms of oropharyngeal leak pressure (OLP), successful insertion attempts, mean insertion time, ease of gastric tube insertion, laryngeal view, and incidence of sore throat among anesthetized, non-paralyzed patients undergoing general anesthesia. In this prospective single-blinded study, 60 patients were randomized to use either LMA Protector™ Cuff Pilot™ or LMA Supreme™. Both groups received standard monitoring and induction regimes. Post-insertion, a bronchoscope was used to verify its position. A gastric tube was inserted and OLP was measured. Patients were assessed during the post-operative period for sore throats. LMA Protector™ Cuff Pilot™ was comparable to LMA Supreme™ in terms of mean OLP (30.72±8.60 vs 27.23±8.09 cmH2O, P = 0.114), first successful attempt (P = 0.312), mean insertion time (27.72±9.45 vs 24.37±6.46 seconds, P = 0.116), and grade 1 laryngeal view (51.7% vs 36.7%, P = 0.244). At first attempt, LMA Protector™ Cuff Pilot™ had a lower success rate of gastric tube insertion than LMA Supreme™ (55.17% vs 96.67%, P <0.001). The incidence of the blood-stained device and sore throat post-operatively were comparable between the two groups. LMA Protector™ Cuff Pilot™ was comparable to LMA Supreme™ in terms of overall clinical performance, except for the first successful gastric tube insertion. Improvements should be made to the gastric channel for easier gastric tube insertion in the LMA Protector™ Cuff Pilot™.


  • Open Access

    Validation of the Malay Self-Report Quick Inventory of Depressive Symptomatology in a Malaysian Sample

    by Lai Fong Chan, Choon Leng Eu, Seng Fah Tong, Song Jie Chin, Shalisah Sharip, Yee Chin Chai, Jiann Lin Loo, Nurul Ain Mohamad Kamal, Jo Aan Goon, Raynuha Mahadevan, et al.

    Depression is ranked as the second-leading cause for years lived with disability worldwide. Objective monitoring with a standardized scale for depressive symptoms can improve treatment outcomes. This study evaluates the construct and concurrent validity of the Malay Self-Report Quick Inventory of Depressive Symptomatology (QIDS-SR16) among Malaysian clinical and community samples. This cross-sectional study was based on 277 participants, i.e., patients with current major depressive episode (MDE), n = 104, and participants without current MDE, n = 173. Participants answered the Malay QIDS-SR16 and were administered the validated Malay Mini-International Neuropsychiatric Interview (MINI) for DSM-IV-TR. Factor analysis was used to determine construct validity, alpha statistic for internal consistency, and receiver operating characteristic (ROC) analysis for concurrent validity with MINI to determine the optimal threshold to identify MDE. Data analysis provided evidence for the unidimensionality of the Malay QIDS-SR16 with good internal consistency (Cronbach’s α = 0.88). Based on ROC analysis, the questionnaire demonstrated good validity with a robust area under the curve of 0.916 (p < 0.000, 95% CI 0.884–0.948). A cut-off score of nine provided the best balance between sensitivity (88.5%) and specificity (83.2%). The Malay QIDS-SR16 is a reliable and valid instrument for identifying MDE in unipolar or bipolar depression.


  • Open Access

    A Randomized Controlled Trial Comparing Wide-Awake Local Anesthesia With No Tourniquet (WALANT) to General Anesthesia in Plating of Distal Radius Fractures With Pain and Anxiety Level Perception

    by Mohd Hazim Abd Hamid, Shalimar Abdullah, Amir Adham Ahmad, Parminder Singh Gill Narin Singh, Elaine Zi Fan Soh, Chian Yong Liu, Jamari Sapuan

    Introduction: Distal end radius fractures are common fractures commonly treated with an option of open reduction and plating. Traditionally, plating is performed under general anesthesia (GA) or regional block. Recently, a new technique of plating under wide-awake local anesthesia with no tourniquet (WALANT) has been introduced. We aim to compare the preoperative anxiety level, intraoperative pain scores, post-operative pain scores, operating time, blood loss and clinical outcome of distal end radius plating with WALANT versus GA with tourniquet. Methods: We conducted a randomized controlled study on patients with closed fracture of the distal end of the radius requiring open reduction and plating from January 2019 till April 2020. We recruited 65 patients (33 patients in the WALANT group and 32 patients in the GA group). Randomization was done via block randomization. Data were collected to evaluate preoperative anxiety using the Amsterdam Preoperative Anxiety and Information Scale (APAIS) score, intraoperative pain score during injection (baseline) (V1), 10 minutes after injection (V2), during incision (V3), during gentle manipulation (V4), during aggressive manipulation (V5) and during first drilling of screw (V6), blood loss, duration of surgery and post-operative pain score. Additionally, intraoperative visual analog scale (VAS) score was obtained in the WALANT group. At three weeks, six weeks, three months and six months after operation, the Quick Disabilities of Arm, Shoulder and Hand (QuickDASH) scores and range of motion (ROM) of the wrists were obtained. Results: The average age in the WALANT group was 47.19 (range, 36-64) years and GA group was 49.48 (range, 38-60) years. The mean APAIS score obtained was 7.78 (WALANT group) and 7.36 (GA group) with no statistical difference. For intraoperative VAS, only during V4 and V5 were the scores 1/10; otherwise at all other phases, the VAS score was 0. The average time for surgery was statistically longer in the WALANT group (61.22 minutes) compared to the GA group (55.33 minutes) (p = 0.003). There was no statistical difference in mean blood loss in both groups. The average post-operative VAS showed statistical significance only at 1 hour and 12 hours post-operation with no statistical difference at 2 and 24 hours post-operation. There was no difference in the post-operative ROM including wrist flexion, extension, supination and pronation for both groups up to six months’ follow-up. Conclusion: There was no statistically significant difference in terms of preoperative anxiety level, intraoperative and post-operative VAS score, amount of blood loss and clinical outcome in both groups for plating of the distal end radius. However, the operating time was slightly longer in the WALANT group. We conclude that distal radius plating under WALANT has similar outcomes to GA. In centres with limited resources, WALANT offers a safe, reliable and cheaper option, reserving GA time for head, abdominal and thoracic surgery.


  • Open Access

    Reduction of the Dimensionality of the EEG Channels during Scoliosis Correction Surgeries Using a Wavelet Decomposition Technique

    by Mahmoud I. Al-Kadi, Mamun Bin Ibne Reaz, Mohd Alauddin Mohd Ali, Chian Yong Liu

    This paper presents a comparison between the electroencephalogram (EEG) channels during scoliosis correction surgeries. Surgeons use many hand tools and electronic devices that directly affect the EEG channels. These noises do not affect the EEG channels uniformly. This research provides a complete system to find the least affected channel by the noise. The presented system consists of five stages: filtering, wavelet decomposing (Level 4), processing the signal bands using four different criteria (mean, energy, entropy and standard deviation), finding the useful channel according to the criteria’s value and, finally, generating a combinational signal from Channels 1 and 2. Experimentally, two channels of EEG data were recorded from six patients who underwent scoliosis correction surgeries in the Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM) (the Medical center of National University of Malaysia). The combinational signal was tested by power spectral density, cross-correlation function and wavelet coherence. The experimental results show that the system-outputted EEG signals are neatly switched without any substantial changes in the consistency of EEG components. This paper provides an efficient procedure for analyzing EEG signals in order to avoid averaging the channels that lead to redistribution of the noise on both channels, reducing the dimensionality of the EEG features and preparing the best EEG stream for the classification and monitoring stage.