AIAzarinah Izaham

Azarinah Izaham

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Azarinah Izaham has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Current Practices of Haemodynamic Monitoring in High-Risk Surgical Patients: A Nationwide Survey Among Malaysian Anaesthesiologists

    by Syarifah Noor Nazihah Sayed Masri, Iskandar Khalid, Weng Ken Chan, Azarinah Izaham, Qurratu Aini Musthafa, Mohd Fitry Zainal Abidin, Siti Nadzrah Yunus, Ina Ismiarti Shariffuddin, Afifah Samsudin, Mohd Zulfakar Mazlan, et al.

    Background: Advanced haemodynamic monitoring has been recommended for use in high-risk surgeries and high-risk patients undergoing surgery. This study aims to assess the current practices of haemodynamic monitoring in high-risk surgical patients among Malaysian anaesthesiologists. Methodology: This is a cross-sectional survey among Malaysian anaesthesiologists, following approval from the institution’s Medical Research Ethics Committee and the National Medical Research Register. The survey utilised a questionnaire developed by Cannesson et al. to gather demographic data, practice information, and haemodynamic monitoring practices. Statistical analysis was performed using SPSS, and results were presented as the mean, median, or frequency as appropriate. Results: A total of 366 participants responded to the questionnaire, and 2 dropped out due to an incomplete form. This study found differences in the frequency of haemodynamic optimisation and monitoring techniques used in different healthcare settings. Written protocols or statements concerning haemodynamic management in high-risk surgical cases were only available to 15.7% of participants in the institution. The overall utilisation rate of cardiac output monitoring was found to be 31.1%, with a significant majority of the usage observed in university hospitals (p < 0.001). Central venous pressure was more commonly used in university hospitals and private hospitals compared to public hospitals (p < 0.001). The usage of advanced parameters such as stroke volume variation, cardiac index, and systemic vascular resistance was significantly higher in university hospitals, with a p value < 0.001. Transthoracic echocardiography was the most common tool used for high-risk surgical patients. The primary reasons for participants not utilising cardiac output monitoring include the lack of availability of such monitoring in their respective settings, which constitutes 66.9% of the respondents. The overwhelming majority of participants, namely 98%, expressed the belief that there is room for improvement in their present haemodynamic care. Conclusions: This study offers significant insights into the prevailing haemodynamic monitoring practices employed by Malaysian anaesthesiologists in the context of high-risk surgical patients. The findings have the potential to contribute to future educational initiatives and establish practice standards for haemodynamic monitoring in high-risk surgical procedures.

  • Open Access

    Performance of Point-of-Care Ultrasonography in Confirming Feeding Tube Placement in Mechanically Ventilated Patients

    by Thanalachumy Ragunathan, Rufinah Teo, Aliza Mohamad Yusof, Siti Nidzwani Mohamad Mahdi, Azarinah Izaham, Chian Yong Liu, Maryam Budiman, Syarifah Noor Nazihah Sayed Masri, Raha Abdul Rahman

    Background: A feeding tube (FT) is routinely placed in critically ill patients, and its correct placement is confirmed with a chest X-ray (CXR), which is considered the gold standard. This study evaluated the diagnostic accuracy of ultrasonography (USG) in verifying FT placement compared to a CXR in an intensive care unit (ICU). Method: This was a prospective single-blind study conducted on patients admitted to the ICU of a tertiary hospital in Malaysia. The FT placements were verified through a fogging test and USG at the neck and subxiphoid points. The results of confirmation of FT placement through USG were compared with those obtained using CXRs. Results: A total of 80 patients were included in this study. The FT positions were accurately confirmed by overall USG assessments in 71 patients. The percentage of FT placements correctly identified by neck USG was 97.5%, while the percentage of those identified by epigastric USG was 75%. The corresponding patients’ CXRs confirmed correct FT placement in 76 patients. The overall USG assessment had a sensitivity of 92.11% and specificity of 75%, a positive predictive value of 98.59%, and a negative predictive value of 33.33%. The USG findings also showed a significant association between FT size and BMI. FTs with a size of 14Fr were better visualized (p = 0.008), and negative USG findings had a significantly higher BMI (p < 0.001). Conclusion: USG is a simple, safe, and reliable bedside assessment that offers relatively high sensitivity in confirming correct FT placement in critically ill patients.


  • Open Access

    Changes in Bispectral Index with different positions during general anaesthesia.

    by Khairunnadiah Kamaruzaman, Azarinah Izaham, Raha Abdul Rahman, Mohammad Nizam Mokhtar

    Background & Objective: Bispectral index (BIS) is used for intraoperative anesthesia depth assessment during general anesthesia (GA). This monitoring modality has been used routinely at many centers during GA, but especially during susceptible patients, in which precise depth of anesthesia is required. We aimed to compare changes of BIS in different head positions under GA, but without surgical stimulation. Methodology: Thirty ASA physical status I patients aged 18−60 y were recruited for this prospective, observational study after ethical approval by the institutional ethical review committee. After administration of GA, patients were kept in supine position for 15 min and the BIS, signal quality index (SQI), electromyography (EMG), mean arterial pressure (MAP) and heart rate (HR) were recorded. Patients were then sequentially placed in: reverse Trendelenburg (45°), supine, Trendelenburg (45°) positions, each for 15-min duration and 3 readings were taken in each position at 5 min interval. Lastly patient was positioned back to supine position for the surgery to begin. Results: There was a statistically significant decrease of BIS value with a change from supine position to reverse Trendelenburg position (P = 0.02) and increase in BIS value from supine to Trendelenburg position (P = 0.01). Changing of position from supine to reverse Trendelenburg was found to have a statistically significant decrease in MAP (P = 0.005), whereas changing to Trendelenburg position significantly increased MAP compared to supine position (P < 0.001). There was a positive moderate linear correlation between BIS and MAP (r = 0.513, P = 0.004). Conclusion: A change of position from supine to reverse Trendelenburg decreases and from supine to Trendelenburg position transiently increases the BIS values. Abbreviations: BIS - Bispectral Index; SQI - Signal Quality Index; EMG – Electromyography; MAP - Mean Arterial Pressure Key words: Anesthesia; Anesthesia, General; Bispectral Index; Electroencephalography; Electromyography; Monitoring; Positioning Citation: Kamaruzaman K, Izaham A, Rahman RA, Mokhtar MN. Changes in bispectral index (BIS) with different positions during general anesthesia. Anaesth. pain intensive care 2023;27(3):325−331. DOI: 10.35975/apic.v27i3.1922 Received: June 24, 2022; Reviewed: April 10, 2023; Accepted: April 10, 2023