Karin Brolin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karin Brolin has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jonas Östh
Chalmers University of Technology
3 shared publications - Mats Y. Svensson
Chalmers University of Technology
3 shared publications - Astrid Linder
Swedish National Road and Transport Research Institute, VTI, Gothenburg, Sweden
2 shared publications - Manuel Mendoza-Vazquez
Department of Applied Mechanics, Chalmers University of Technology, SE - 412 96 Gothenburg, Sweden
2 shared publications - Antonio Ferreiro Perez
Fundación de Investigación HM Hospitales, Avenida de Montepríncipe nº 25, 28660 Boadilla del Monte, Madrid, Spain
1 shared publication - Erik Eliasson
Department of Laboratory Medicine, Clinical Pharmacology, Karolinska Institutet and Karolinska University Hospital, Stockholm, Sweden
1 shared publication
Latest Publications
- 6 November 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 141 (12)
Relationship Between Cervical, Thoracic, and Lumbar Spinal Alignments in Automotive Seated Posture
The purpose of this study was to investigate the relationship between cervical, thoracic, and lumbar spinal alignments in one automotive occupant seated posture. An image dataset of the spinal column in the automotive seated posture, previously acquired by an upright open magnetic resonance imaging (MRI) system, was re-analyzed in this study. Spinal alignments were presented by the geometrical centers of the vertebral bodies extracted from the image data. Cervical, thoracic, and lumbar spinal alignments were analyzed separately with multidimensional scaling (MDS). Based on distribution maps of cervical, thoracic, and lumbar spinal alignments created by MDS, representative spinal alignment patterns of the cervical, thoracic, and lumbar spines and the relationship between cervical, thoracic, and lumbar spinal alignments were investigated. As a result, this study found a correlation between cervical and thoracic spinal alignments in an automotive occupant seated posture. According to representative spinal alignment patterns illustrated by the distribution map of spinal alignments, subjects who had kyphotic cervical spinal alignment tended to have less kyphotic thoracic spinal alignment, while subjects who had lordotic cervical spinal alignment tended to have more kyphotic thoracic spinal alignment. For lumbar spinal alignments, no prominent relationship was found between cervical and thoracic spinal alignment in the seated condition of this study.
- 6 November 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 141 (12)
Relationship Between Cervical, Thoracic, and Lumbar Spinal Alignments in Automotive Seated Posture
The purpose of this study was to investigate the relationship between cervical, thoracic, and lumbar spinal alignments in one automotive occupant seated posture. An image dataset of the spinal column in the automotive seated posture, previously acquired by an upright open magnetic resonance imaging (MRI) system, was re-analyzed in this study. Spinal alignments were presented by the geometrical centers of the vertebral bodies extracted from the image data. Cervical, thoracic, and lumbar spinal alignments were analyzed separately with multidimensional scaling (MDS). Based on distribution maps of cervical, thoracic, and lumbar spinal alignments created by MDS, representative spinal alignment patterns of the cervical, thoracic, and lumbar spines and the relationship between cervical, thoracic, and lumbar spinal alignments were investigated. As a result, this study found a correlation between cervical and thoracic spinal alignments in an automotive occupant seated posture. According to representative spinal alignment patterns illustrated by the distribution map of spinal alignments, subjects who had kyphotic cervical spinal alignment tended to have less kyphotic thoracic spinal alignment, while subjects who had lordotic cervical spinal alignment tended to have more kyphotic thoracic spinal alignment. For lumbar spinal alignments, no prominent relationship was found between cervical and thoracic spinal alignment in the seated condition of this study.
- 12 February 2018
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 140 (4)
A Nonlinear Viscoelastic Model for Adipose Tissue Representing Tissue Response at a Wide Range of Strain Rates and High Strain Levels
Finite element human body models (FEHBMs) are nowadays commonly used to simulate pre- and in-crash occupant response in order to develop advanced safety systems. In this study, a biofidelic model for adipose tissue is developed for this application. It is a nonlinear viscoelastic model based on the Reese et al.'s formulation. The model is formulated in a large strain framework and applied for finite element (FE) simulation of two types of experiments: rheological experiments and ramped-displacement experiments. The adipose tissue behavior in both experiments is represented well by this model. It indicates the capability of the model to be used in large deformation and wide range of strain rates for application in human body models.
- 12 February 2018
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 140 (4)
A Nonlinear Viscoelastic Model for Adipose Tissue Representing Tissue Response at a Wide Range of Strain Rates and High Strain Levels
Finite element human body models (FEHBMs) are nowadays commonly used to simulate pre- and in-crash occupant response in order to develop advanced safety systems. In this study, a biofidelic model for adipose tissue is developed for this application. It is a nonlinear viscoelastic model based on the Reese et al.'s formulation. The model is formulated in a large strain framework and applied for finite element (FE) simulation of two types of experiments: rheological experiments and ramped-displacement experiments. The adipose tissue behavior in both experiments is represented well by this model. It indicates the capability of the model to be used in large deformation and wide range of strain rates for application in human body models.
- Open Access
- 1 January 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 51, 49-56
A female head–neck model for rear impact simulations
- 1 January 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 51, 49-56
Open AccessA female head–neck model for rear impact simulations
- 2 May 2016
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 138 (6) , 061005
A Female Ligamentous Cervical Spine Finite Element Model Validated for Physiological Loads
Mathematical cervical spine models allow for studying of impact loading that can cause whiplash associated disorders (WAD). However, existing models only cover the male anthropometry, despite the female population being at a higher risk of sustaining WAD in automotive rear-end impacts. The aim of this study is to develop and validate a ligamentous cervical spine intended for biomechanical research on the effect of automotive impacts. A female model has the potential to aid the design of better protection systems as well as improve understanding of injury mechanisms causing WAD. A finite element (FE) mesh was created from surface data of the cervical vertebrae of a 26-year old female (stature 167 cm, weight 59 kg). Soft tissues were generated from the skeletal geometry and anatomical literature descriptions. Ligaments were modeled with nonlinear elastic orthotropic membrane elements, intervertebral disks as composites of nonlinear elastic bulk elements, and orthotropic anulus fibrosus fiber layers, while cortical and trabecular bones were modeled as isotropic plastic–elastic. The model has geometrical features representative of the female cervical spine—the largest average difference compared with published anthropometric female data was the vertebral body depth being 3.4% shorter for the model. The majority the cervical segments compare well with respect to biomechanical data at physiological loads, with the best match for flexion–extension loads and less biofidelity for axial rotation. An average female FE ligamentous cervical spine model was developed and validated with respect to physiological loading. In flexion–extension simulations with the developed female model and an existing average male cervical spine model, a greater range of motion (ROM) was found in the female model.
- 2 May 2016
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 138 (6) , 061005
A Female Ligamentous Cervical Spine Finite Element Model Validated for Physiological Loads
Mathematical cervical spine models allow for studying of impact loading that can cause whiplash associated disorders (WAD). However, existing models only cover the male anthropometry, despite the female population being at a higher risk of sustaining WAD in automotive rear-end impacts. The aim of this study is to develop and validate a ligamentous cervical spine intended for biomechanical research on the effect of automotive impacts. A female model has the potential to aid the design of better protection systems as well as improve understanding of injury mechanisms causing WAD. A finite element (FE) mesh was created from surface data of the cervical vertebrae of a 26-year old female (stature 167 cm, weight 59 kg). Soft tissues were generated from the skeletal geometry and anatomical literature descriptions. Ligaments were modeled with nonlinear elastic orthotropic membrane elements, intervertebral disks as composites of nonlinear elastic bulk elements, and orthotropic anulus fibrosus fiber layers, while cortical and trabecular bones were modeled as isotropic plastic–elastic. The model has geometrical features representative of the female cervical spine—the largest average difference compared with published anthropometric female data was the vertebral body depth being 3.4% shorter for the model. The majority the cervical segments compare well with respect to biomechanical data at physiological loads, with the best match for flexion–extension loads and less biofidelity for axial rotation. An average female FE ligamentous cervical spine model was developed and validated with respect to physiological loading. In flexion–extension simulations with the developed female model and an existing average male cervical spine model, a greater range of motion (ROM) was found in the female model.
- 1 December 2015
- Published by Elsevier in Accident Analysis & Prevention
- Vol. 85, 73-82
Construction and evaluation of thoracic injury risk curves for a finite element human body model in frontal car crashes
- 1 December 2015
- Published by Elsevier in Accident Analysis & Prevention
- Vol. 85, 73-82
Construction and evaluation of thoracic injury risk curves for a finite element human body model in frontal car crashes
- Open Access
- 1 September 2014
- Published by Elsevier in Gait & Posture
- Vol. 40 (4) , 664-669
A method to model anticipatory postural control in driver braking events
- 1 September 2014
- Published by Elsevier in Gait & Posture
- Vol. 40 (4) , 664-669
Open AccessA method to model anticipatory postural control in driver braking events