Zaipeng Man
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zaipeng Man has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Fan Ding
The State Key Lab of Fluid Power Transmission and Control, Zhejiang University, Hangzhou 310027, China
2 shared publications - Shuo Liu
Ocean Academy, Zhejiang University, Zhoushan 316000, China
2 shared publications Chuan Ding
1 shared publication- Chuan Ding
The State Key Lab of Fluid Power Transmission and Control, Zhejiang University, Hangzhou 310027, China
1 shared publication
Latest Publications
- 15 March 2015
- Published by Faculty of Mechanical Engineering in Strojniški vestnik - Journal of Mechanical Engineering
- Vol. 61 (3) , 196-206
Study of an Energy Regeneration System with Accumulator for Hydraulic Impulse Testing Equipment
- 15 March 2015
- Published by Faculty of Mechanical Engineering in Strojniški vestnik - Journal of Mechanical Engineering
- Vol. 61 (3) , 196-206
Study of an Energy Regeneration System with Accumulator for Hydraulic Impulse Testing Equipment
- Open Access
A High-Pressure Bi-Directional Cycloid Rotor Flowmeter
The measurement of the flow rate of various liquids and gases is critical in industrial automation. Rotary positive displacement meters (rotary PD meters) are highly accurate flowmeters that are widely employed in engineering applications, especially in custody transfer operations and hydraulic control systems. This paper presents a high pressure rotary PD meter containing a pair of internal cycloid rotors. It has the advantages of concise structure, low pressure loss, high accuracy and low noise. The curve of the internal rotor is designed as an equidistant curtate epicycloid curve with the external rotor curve as its conjugate. The calculation method used to determine the displacement of the cycloid rotor flowmeter is discussed. A prototype was fabricated, and experiments were performed to confirm measurements over a flow range of 1–100 L/min with relative errors of less than ±0.5%. The pressure loss through the flowmeter was about 3 bar at a flow rate of 100 L/min.
Open AccessA High-Pressure Bi-Directional Cycloid Rotor Flowmeter
The measurement of the flow rate of various liquids and gases is critical in industrial automation. Rotary positive displacement meters (rotary PD meters) are highly accurate flowmeters that are widely employed in engineering applications, especially in custody transfer operations and hydraulic control systems. This paper presents a high pressure rotary PD meter containing a pair of internal cycloid rotors. It has the advantages of concise structure, low pressure loss, high accuracy and low noise. The curve of the internal rotor is designed as an equidistant curtate epicycloid curve with the external rotor curve as its conjugate. The calculation method used to determine the displacement of the cycloid rotor flowmeter is discussed. A prototype was fabricated, and experiments were performed to confirm measurements over a flow range of 1–100 L/min with relative errors of less than ±0.5%. The pressure loss through the flowmeter was about 3 bar at a flow rate of 100 L/min.