Hari Prasad Aithal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hari Prasad Aithal has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Amar Pal
Division of Surgery, ICAR-Indian Veterinary Research Institute, Bareilly, India
3 shared publications Amarpal
Training and Education Centre, Indian Veterinary Research Institute, Pune-411 001, Maharashtra, India
3 shared publicationsPrakash Kinjavdekar
Training and Education Centre, Indian Veterinary Research Institute, Pune-411 001, Maharashtra, India
3 shared publicationsA. M. Pawde
2 shared publications- Prakash Kinjavdekar
Division of Surgery, ICAR-Indian Veterinary Research Institute, Izatnagar, Bareilly, Uttar Pradesh, India
2 shared publications Rohit Kumar
Division of Surgery, Indian Veterinary Research Institute, Izzatnagar, Uttar Pradesh, India
2 shared publications
Latest Publications
- Open Access
- 12 January 2026
- Published by Agricultural Research Communication Center in Indian Journal of Animal Research
- No. Of
Evaluation of Titanium Elastic Nails for Femoral Fractures in Young Dogs: A Clinical Study
Background: Femur fractures from multifactorial etiologies are a common occurrence in young and growing dogs. Various methods of internal fixation are available to repair young femur fractures but titanium elastic nails (TENs) are superior in stabilizing such fractures. Micromotion at the fracture site by these nails limits stress shielding and stimulates for early callus formation. TENs nails have been used in children but fewer studies are conducted in immature dogs in the recent years. The objective of this study was the clinical evaluation of TENs technique in femur fracture fixation among young dogs. Methods: This study included 16 clinical cases of young ( less than 2 months) dogs (12 male and 4 female) with mean ± SD age of 5.19±2.83 month, body weight 7.46±5.07 Kg injured since 2.93±2.14 days and associated with vehicular accident, fall from height, hit injury with stick and unknown injury with femur fractures. TENs technique was applied in all the classes and postoperative clinical evaluation was done. Result: All the cases resulted in satisfactory functional outcome based on radiographically visible early bridging callus with mean radiographic fracture healing score of 2.43±0.18, better fracture union (bone union score: 1.37±0.24 and bone formation score: 2.25±0.19), early weight bearing (standing: 2.43±0.28 days, walking: 4.93±0.39 days, pain perception score (1.62±0.12) and ambulation with weight bearing score: 2.5±0.12 (standing) and 3.00±0.22 (walking), respectively on 15th postoperative day, in affected dogs with no major complications. Therefore, TENs technique provides an adequate repair of diaphyseal and supracondylar femur fractures in young dogs with better postoperative outcome.
- 12 January 2026
- Published by Agricultural Research Communication Center in Indian Journal of Animal Research
- No. Of
Open AccessEvaluation of Titanium Elastic Nails for Femoral Fractures in Young Dogs: A Clinical Study
Background: Femur fractures from multifactorial etiologies are a common occurrence in young and growing dogs. Various methods of internal fixation are available to repair young femur fractures but titanium elastic nails (TENs) are superior in stabilizing such fractures. Micromotion at the fracture site by these nails limits stress shielding and stimulates for early callus formation. TENs nails have been used in children but fewer studies are conducted in immature dogs in the recent years. The objective of this study was the clinical evaluation of TENs technique in femur fracture fixation among young dogs. Methods: This study included 16 clinical cases of young ( less than 2 months) dogs (12 male and 4 female) with mean ± SD age of 5.19±2.83 month, body weight 7.46±5.07 Kg injured since 2.93±2.14 days and associated with vehicular accident, fall from height, hit injury with stick and unknown injury with femur fractures. TENs technique was applied in all the classes and postoperative clinical evaluation was done. Result: All the cases resulted in satisfactory functional outcome based on radiographically visible early bridging callus with mean radiographic fracture healing score of 2.43±0.18, better fracture union (bone union score: 1.37±0.24 and bone formation score: 2.25±0.19), early weight bearing (standing: 2.43±0.28 days, walking: 4.93±0.39 days, pain perception score (1.62±0.12) and ambulation with weight bearing score: 2.5±0.12 (standing) and 3.00±0.22 (walking), respectively on 15th postoperative day, in affected dogs with no major complications. Therefore, TENs technique provides an adequate repair of diaphyseal and supracondylar femur fractures in young dogs with better postoperative outcome.
- 2 April 2021
- Published by Agricultural Research Communication Center in Indian Journal of Animal Research
- Vol. 57 (Of) , 58-65
Acrylic and Epoxy-pin External Skeletal Fixation Systems for Fracture Management in Dogs
Background: The metallic ESF systems are not easily available in the field and have fixed frames leading to less versatility in size and direction. Free forms of external skeletal fixators (acrylic and epoxy-pin) have advantages as they can be customized. Both acrylic and epoxy-pin ESF systems have been evaluated biomechanically in earlier studies; in the present study both are compared clinically. Methods: Twenty four dogs presented with 27 fractures of long bones, were randomly divided into 4 groups, according to the bones involved, group A was divided into A-I (radius-ulna) and A-II (tibia-fibula) sub-groups and group B was divided into B-I (radius-ulna) and B-II (tibia-fibula) sub-groups. Result: The mean±SE fracture healing time in animals was 48.85±2.56 days with no significant difference between two groups.The early presented cases and the ones with less soft tissue trauma showed better gait scores during the follow up period. Both acrylic and epoxy-pin fixators provided stable fixation and the technique can be practiced at field conditions with minimal facilities. Epoxy-pin ESF owing to better handling characteristics of epoxy resin is easier to construct than the acrylic ESF.
- 2 April 2021
- Published by Agricultural Research Communication Center in Indian Journal of Animal Research
- Vol. 57 (Of) , 58-65
Acrylic and Epoxy-pin External Skeletal Fixation Systems for Fracture Management in Dogs
Background: The metallic ESF systems are not easily available in the field and have fixed frames leading to less versatility in size and direction. Free forms of external skeletal fixators (acrylic and epoxy-pin) have advantages as they can be customized. Both acrylic and epoxy-pin ESF systems have been evaluated biomechanically in earlier studies; in the present study both are compared clinically. Methods: Twenty four dogs presented with 27 fractures of long bones, were randomly divided into 4 groups, according to the bones involved, group A was divided into A-I (radius-ulna) and A-II (tibia-fibula) sub-groups and group B was divided into B-I (radius-ulna) and B-II (tibia-fibula) sub-groups. Result: The mean±SE fracture healing time in animals was 48.85±2.56 days with no significant difference between two groups.The early presented cases and the ones with less soft tissue trauma showed better gait scores during the follow up period. Both acrylic and epoxy-pin fixators provided stable fixation and the technique can be practiced at field conditions with minimal facilities. Epoxy-pin ESF owing to better handling characteristics of epoxy resin is easier to construct than the acrylic ESF.
- 1 February 2021
- Published by Wiley in Veterinary Surgery
- Vol. 50 (2) , 444-454
Biomechanical properties of a novel locking compression plate to stabilize oblique tibial osteotomies in buffaloes
Objective Quantitation of mechanical properties of a novel locking compression plate (LCP) for bovine tibia. Study design Prospective in vitro study. Sample population Adult Murrah buffalo (250-350 kg) tibiae. Methods Forty tibiae were randomly assigned to five treatment groups (n = 8/group): intact bone and bone constructs with a standard nonlocking plate, single LCP, double LCP, and novel LCP. During implant application, a mid-diaphyseal, oblique osteotomy was performed in all constructs, which were subsequently tested in axial compression (n = 4 each) or three-point craniocaudal bending (n = 4 each). Novel LCP alone (n = 4) was tested only in bending. Stiffness, yield load, ultimate failure load, and bending moment were determined from the load deformation curves and compared among different treatment groups (P < .05). Results Under compression, yield load of the novel LCP (24.07 +/- 3.45 kN) was greater than that of the nonlocking plate (11.10 +/- 2.46 kN) and the single LCP (18.01 +/- 2.07 kN) but less than that of the double LCP (30.61 +/- 1.95 kN), and ultimate failure load of the novel LCP (25.85 +/- 4.32 kN) was greater than that of the nonlocking plate (13.18 +/- 2.91 kN) but similar to that of the single LCP (21.17 +/- 2.33 kN) and the double LCP (32.40 +/- 1.46 kN). Bending moment, yield load, and ultimate failure load of the novel LCP were 565.37 +/- 79.30 Nm, 7.90 +/- 1.14 kN, 9.83 +/- 1.38 kN, respectively, which were greater than those of the nonlocking plate and the single LCP but comparable to those of the double LCP. Conclusion The novel LCP developed for bovine tibia was mechanically superior to the standard nonlocking plate or the single LCP and comparable to the double LCP. Clinical significance The novel LCP may provide rigid fixation of tibial diaphyseal fractures in buffaloes and cattle weighing 250 to 350 kg.
- 1 February 2021
- Published by Wiley in Veterinary Surgery
- Vol. 50 (2) , 444-454
Biomechanical properties of a novel locking compression plate to stabilize oblique tibial osteotomies in buffaloes
Objective Quantitation of mechanical properties of a novel locking compression plate (LCP) for bovine tibia. Study design Prospective in vitro study. Sample population Adult Murrah buffalo (250-350 kg) tibiae. Methods Forty tibiae were randomly assigned to five treatment groups (n = 8/group): intact bone and bone constructs with a standard nonlocking plate, single LCP, double LCP, and novel LCP. During implant application, a mid-diaphyseal, oblique osteotomy was performed in all constructs, which were subsequently tested in axial compression (n = 4 each) or three-point craniocaudal bending (n = 4 each). Novel LCP alone (n = 4) was tested only in bending. Stiffness, yield load, ultimate failure load, and bending moment were determined from the load deformation curves and compared among different treatment groups (P < .05). Results Under compression, yield load of the novel LCP (24.07 +/- 3.45 kN) was greater than that of the nonlocking plate (11.10 +/- 2.46 kN) and the single LCP (18.01 +/- 2.07 kN) but less than that of the double LCP (30.61 +/- 1.95 kN), and ultimate failure load of the novel LCP (25.85 +/- 4.32 kN) was greater than that of the nonlocking plate (13.18 +/- 2.91 kN) but similar to that of the single LCP (21.17 +/- 2.33 kN) and the double LCP (32.40 +/- 1.46 kN). Bending moment, yield load, and ultimate failure load of the novel LCP were 565.37 +/- 79.30 Nm, 7.90 +/- 1.14 kN, 9.83 +/- 1.38 kN, respectively, which were greater than those of the nonlocking plate and the single LCP but comparable to those of the double LCP. Conclusion The novel LCP developed for bovine tibia was mechanically superior to the standard nonlocking plate or the single LCP and comparable to the double LCP. Clinical significance The novel LCP may provide rigid fixation of tibial diaphyseal fractures in buffaloes and cattle weighing 250 to 350 kg.
- 28 March 2019
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 32 (03) , 257-268
Epoxy-Pin External Skeletal Fixation for Management of Open Bone Fractures in Calves and Foals: A Review of 32 Cases
Objective The aim of this study was to evaluate epoxy-pin external skeletal fixation technique for the treatment of open fractures in calves and foals. Study Design Twenty-eight calves and four foals (weighing 45–105 kg) with fractures distal to the stifle or elbow made the subject for the retrospective study. The pins (2.0–3.0-mm Kirschner wires, crossed at 60–90°) were fixed at least at two locations in both proximal and distal bone fragments as per the case situation. The pins in the same plane were bent (∼2 cm from the skin) towards the fracture site or joint and were joined using an adhesive tape (additional pins used when required) to make a temporary scaffold of connecting bars or rings. Thoroughly mixed epoxy putty was applied along the pin scaffold (the epoxy columns were 20–25 mm diameter) and allowed to set for 45 to 60 minutes. All animals were evaluated based on various clinical and radiographic observations made at regular intervals. Results The epoxy-pin fixation was easy to apply and provided stable fixation of bone as indicated by early weight bearing, and fracture healing within 45 to 60 days (17/32 cases). The functional recovery was good to very good in 14 animals and satisfactory in nine cases by 12 months after removal of the fixator. Conclusions The multiplanar epoxy-pin external skeletal fixation provides stable fixation of unstable open fractures distal to the stifle or elbow joint; hence, it can be used to treat a variety of fractures in calves and foals weighing up to approximately 100 kg, especially open infected fractures of lower limb, which are difficult to treat by conventional techniques.
- 28 March 2019
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 32 (03) , 257-268
Epoxy-Pin External Skeletal Fixation for Management of Open Bone Fractures in Calves and Foals: A Review of 32 Cases
Objective The aim of this study was to evaluate epoxy-pin external skeletal fixation technique for the treatment of open fractures in calves and foals. Study Design Twenty-eight calves and four foals (weighing 45–105 kg) with fractures distal to the stifle or elbow made the subject for the retrospective study. The pins (2.0–3.0-mm Kirschner wires, crossed at 60–90°) were fixed at least at two locations in both proximal and distal bone fragments as per the case situation. The pins in the same plane were bent (∼2 cm from the skin) towards the fracture site or joint and were joined using an adhesive tape (additional pins used when required) to make a temporary scaffold of connecting bars or rings. Thoroughly mixed epoxy putty was applied along the pin scaffold (the epoxy columns were 20–25 mm diameter) and allowed to set for 45 to 60 minutes. All animals were evaluated based on various clinical and radiographic observations made at regular intervals. Results The epoxy-pin fixation was easy to apply and provided stable fixation of bone as indicated by early weight bearing, and fracture healing within 45 to 60 days (17/32 cases). The functional recovery was good to very good in 14 animals and satisfactory in nine cases by 12 months after removal of the fixator. Conclusions The multiplanar epoxy-pin external skeletal fixation provides stable fixation of unstable open fractures distal to the stifle or elbow joint; hence, it can be used to treat a variety of fractures in calves and foals weighing up to approximately 100 kg, especially open infected fractures of lower limb, which are difficult to treat by conventional techniques.
- Open Access
- 8 February 2017
- Published by Veterinary World in Veterinary World
- Vol. 10 (2) , 163-169
Evaluation of tissue-engineered bone constructs using rabbit fetal osteoblasts on acellular bovine cancellous bone matrix
The aim of this study was to generate composite bone graft and investigate the rabbit fetal osteoblasts adhesion, proliferation and penetration on acellular matrices of cancellous bone. Acellular cancellous bone was prepared and developed as in the previous study with little modification. These matrices were decellularized by rapid freeze and thaw cycle. To remove the cell debris, they were then treated with hydrogen peroxide (3%) and ethanol to remove antigenic cellular and nuclear materials from the scaffold. Primary osteoblast cells were harvested from 20 to 22 days old rabbit fetal long and calvarial bone. These cells were cultured and characterized using a specific marker. The third passaged fetal osteoblast cells were then seeded on the scaffold and incubated for 14 days. The growth pattern of the cells was observed. Scanning electron microscope and hematoxylin and eosin staining were used to investigate cells proliferation. The cells were found to be growing well on the surface of the scaffold and were also present in good numbers with the matrix filopodial extensions upto inside of the core of the tissue. Thus, a viable composite scaffold of bone could be developed which has a great potential in the field of bone tissue engineering.
- 8 February 2017
- Published by Veterinary World in Veterinary World
- Vol. 10 (2) , 163-169
Open AccessEvaluation of tissue-engineered bone constructs using rabbit fetal osteoblasts on acellular bovine cancellous bone matrix
The aim of this study was to generate composite bone graft and investigate the rabbit fetal osteoblasts adhesion, proliferation and penetration on acellular matrices of cancellous bone. Acellular cancellous bone was prepared and developed as in the previous study with little modification. These matrices were decellularized by rapid freeze and thaw cycle. To remove the cell debris, they were then treated with hydrogen peroxide (3%) and ethanol to remove antigenic cellular and nuclear materials from the scaffold. Primary osteoblast cells were harvested from 20 to 22 days old rabbit fetal long and calvarial bone. These cells were cultured and characterized using a specific marker. The third passaged fetal osteoblast cells were then seeded on the scaffold and incubated for 14 days. The growth pattern of the cells was observed. Scanning electron microscope and hematoxylin and eosin staining were used to investigate cells proliferation. The cells were found to be growing well on the surface of the scaffold and were also present in good numbers with the matrix filopodial extensions upto inside of the core of the tissue. Thus, a viable composite scaffold of bone could be developed which has a great potential in the field of bone tissue engineering.
- Open Access
- 5 August 2014
- Published by Veterinary World in Veterinary World
- Vol. 7 (8)
Clinicophysiological, haematobiochemical and haemodynamic effect of propofol and ketamine with dexmedetomidine in urolithic goats
- 5 August 2014
- Published by Veterinary World in Veterinary World
- Vol. 7 (8)
Open AccessClinicophysiological, haematobiochemical and haemodynamic effect of propofol and ketamine with dexmedetomidine in urolithic goats
- 10 October 2007
- Published by Wiley in Journal of Veterinary Medicine Series A
- Vol. 54 (9) , 484-490
Occurrence and Pattern of Long Bone Fractures in Growing Dogs with Normal and Osteopenic Bones
A retrospective study was undertaken to record the occurrence and pattern of long bone fractures, and the efficacy of Intramedullary (IM) Steinmann pin fixing in growing dogs. All the records of growing dogs during a 10-year-period were screened to record the cause of trauma, the age and sex of the animal, the bone involved, the type and location of the fracture, the status of fixation, alignment, maintenance of fixation and fracture healing. The results were analysed and comparisons were made between growing dogs with normal and osteopenic bones. Among the 310 cases of fractures recorded, the bones were osteopenic in 91 cases (29%). Minor trauma was the principal cause of fracture in dogs with osteopenia (25%), and indigenous breeds were most commonly affected (38%). Fractures in dogs with osteopenic bones were most commonly recorded in the age group of 2-4 months (53%), whereas fractures in normal dogs were almost equally distributed between 2 and 8 months of age. Male dogs were affected significantly more often in both groups. In osteopenic bones, most fractures were recorded in the femur (56%), and they were distributed equally along the length of the bone. Whereas in normal bones, fractures were almost equally distributed in radius/ulna, femur and tibia, and were more often recorded at the middle and distal third of long bones. Oblique fractures were most common in both groups; however, comminuted fractures were more frequent in normal bones, whereas incomplete fractures were more common in osteopenic bones. Ninety-nine fracture cases treated with IM pinning (66 normal, 33 osteopenic) were evaluated for the status of fracture reduction and healing. In a majority of the cases (61%) with osteopenic bones, the diameter of the pin was relatively smaller than the diameter of the medullary cavity (<70-75%), whereas in 68% of the cases in normal bones the pin diameter was optimum. The status of fracture fixing was satisfactory to good in significantly more osteonormal (59%) than osteopenic dogs (42%). Fracture healing, however, was satisfactory in significantly more cases with osteopenic than normal bones. The appearance of callus was relatively early and the amount of bridging callus was relatively large in greater number of osteopenic bone fractures. Mal-union and non-union were recorded more often in osteopenic cases than in normal cases. However, the incidence of bone shortening and osteomyelitis was significantly higher in normal bones than in osteopenic bones.
- 10 October 2007
- Published by Wiley in Journal of Veterinary Medicine Series A
- Vol. 54 (9) , 484-490
Occurrence and Pattern of Long Bone Fractures in Growing Dogs with Normal and Osteopenic Bones
A retrospective study was undertaken to record the occurrence and pattern of long bone fractures, and the efficacy of Intramedullary (IM) Steinmann pin fixing in growing dogs. All the records of growing dogs during a 10-year-period were screened to record the cause of trauma, the age and sex of the animal, the bone involved, the type and location of the fracture, the status of fixation, alignment, maintenance of fixation and fracture healing. The results were analysed and comparisons were made between growing dogs with normal and osteopenic bones. Among the 310 cases of fractures recorded, the bones were osteopenic in 91 cases (29%). Minor trauma was the principal cause of fracture in dogs with osteopenia (25%), and indigenous breeds were most commonly affected (38%). Fractures in dogs with osteopenic bones were most commonly recorded in the age group of 2-4 months (53%), whereas fractures in normal dogs were almost equally distributed between 2 and 8 months of age. Male dogs were affected significantly more often in both groups. In osteopenic bones, most fractures were recorded in the femur (56%), and they were distributed equally along the length of the bone. Whereas in normal bones, fractures were almost equally distributed in radius/ulna, femur and tibia, and were more often recorded at the middle and distal third of long bones. Oblique fractures were most common in both groups; however, comminuted fractures were more frequent in normal bones, whereas incomplete fractures were more common in osteopenic bones. Ninety-nine fracture cases treated with IM pinning (66 normal, 33 osteopenic) were evaluated for the status of fracture reduction and healing. In a majority of the cases (61%) with osteopenic bones, the diameter of the pin was relatively smaller than the diameter of the medullary cavity (<70-75%), whereas in 68% of the cases in normal bones the pin diameter was optimum. The status of fracture fixing was satisfactory to good in significantly more osteonormal (59%) than osteopenic dogs (42%). Fracture healing, however, was satisfactory in significantly more cases with osteopenic than normal bones. The appearance of callus was relatively early and the amount of bridging callus was relatively large in greater number of osteopenic bone fractures. Mal-union and non-union were recorded more often in osteopenic cases than in normal cases. However, the incidence of bone shortening and osteomyelitis was significantly higher in normal bones than in osteopenic bones.