JRJohn Spence Reid

John Spence Reid

*This is an algorithmically generated author record based on publicly available information.

John Spence Reid has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • David C. Goodspeed

    Department of Orthopedic Surgery, University of Wisconsin—Madison, Madison, Wisconsin

    2 shared publications
  • Arthur Berg

    Penn State College of Medicine

    1 shared publication
  • Comron Saifi

    Houston Methodist Orthopedics & Sports Medicine, Houston Methodist Hospital, Houston, TX, USA

    1 shared publication
  • Cyrus T. Caroom

    Department of Orthopaedics and Rehabilitation, Penn State College of Medicine, M.S. Hershey Medical Center, Hershey, PA

    1 shared publication
  • Darin Jurgensmeier

    Department of Orthopaedics and Rehabilitation, Penn State College of Medicine, M.S. Hershey Medical Center, Hershey, PA

    1 shared publication
  • David Fryzel

    Departments of Orthopaedics and Rehabilitation (V.S., H.J.D., D.F., J.G., and J.S.R.), Pharmacology (K.E.V.), and Public Health Sciences (A.B.), Penn State Hershey College of Medicine, 500 University Drive, Hershey, PA 17033. address for J.S. Reid:

    1 shared publication

Latest Publications

  • Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures

    by Gregory S. Lewis, Cyrus T. Caroom, Hwabok Wee, Darin Jurgensmeier, Shane D. Rothermel, Michelle A. Bramer, John Spence Reid

    Objectives: The biomechanical difficulty in fixation of a Vancouver B1 periprosthetic fracture is purchase of the proximal femoral segment in the presence of the hip stem. Several newer technologies provide the ability to place bicortical locking screws tangential to the hip stem with much longer lengths of screw purchase compared with unicortical screws. This biomechanical study compares the stability of 2 of these newer constructs to previous methods. Methods: Thirty composite synthetic femurs were prepared with cemented hip stems. The distal femur segment was osteotomized, and plates were fixed proximally with either (1) cerclage cables, (2) locked unicortical screws, (3) a composite of locked screws and cables, or tangentially directed bicortical locking screws using either (4) a stainless steel locking compression plate system with a Locking Attachment Plate (Synthes) or (5) a titanium alloy Non-Contact Bridging system (Zimmer). Specimens were tested to failure in either axial or torsional quasistatic loading modes (n = 3) after 20 moderate load preconditioning cycles. Stiffness, maximum force, and failure mechanism were determined. Results: Bicortical constructs resisted higher (by an average of at least 27%) maximum forces than the other 3 constructs in torsional loading (P < 0.05). Cables constructs exhibited lower maximum force than all other constructs, in both axial and torsional loading. The bicortical titanium construct was stiffer than the bicortical stainless steel construct in axial loading. Conclusions: Proximal fixation stability is likely improved with the use of bicortical locking screws as compared with traditional unicortical screws and cable techniques. In this study with a limited sample size, we found the addition of cerclage cables to unicortical screws may not offer much improvement in biomechanical stability of unstable B1 fractures.


  • Outcome of 28 open pilon fractures with injury severity-based fixation

    by Jonathan R. Danoff, Comron Saifi, David C. Goodspeed, J. Spence Reid

    Open pilon fracture management and treatment poses a significant challenge to orthopedic surgeons. The purpose of this study was to determine patient outcomes for open pilon fractures based on wound complication and infection rates, as well as subjective outcome instruments. This was a retrospective consecutive case series of 28 fractures with Orthopaedic Trauma Association (OTA)-type 43-B and 43-C open pilon fractures. Mean length of follow-up was 36 months and minimum of 1 year. Ten fractures were Gustilo and Anderson grade IIIB, and the remaining fractures were grades I–IIIA. Patients were initially treated with spanning external fixation and staged wound debridement followed by osteosynthesis of the articular surface. Metaphyseal fixation was by either plate fixation or Ilizarov frame. The primary outcome was the incidence of deep tissue infection requiring surgery. Secondary outcomes included the incidence of other complications (nonunion, malunion, amputation) and functional outcomes (Short Musculoskeletal Functional Assessment Questionnaire and AAOS Foot and Ankle Questionnaire). Four patients developed deep tissue infections, three in the internal fixation group and one in the Ilizarov group, and all were treated successfully with staged debridement. There were two delayed unions required bone grafting, and infection-free union was ultimately achieved in all fractures. Two patients underwent arthrodesis secondary to post-traumatic arthritis, while no patients experienced malunions or amputations. The use of staged wound debridement in conjunction with either plate fixation or Ilizarov frame achieves low rates of wound infection and stable fixation after anatomic joint reconstruction for OTA-type 43-B and 43-C open pilon fractures.


  • Single Nucleotide Polymorphisms in Osteogenic Genes in Atrophic Delayed Fracture-Healing

    by Vikram Sathyendra, Henry J. Donahue, Kent E. Vrana, Arthur Berg, David Fryzel, Jonathan Gandhi, J. Spence Reid

    Ore single nucleotide polymorphisms (SNPs) within a series of genes related to bone formation. Methods: We performed a population-based, case-controlled study of delayed fracture-healing. Sixty-two adults with a long-bone fracture were identified from a surgical database. Thirty-three patients had an atrophic nonunion (delayed healing), and twenty-nine displayed normal fracture-healing. These patients underwent buccal mucosal cell harvesting. SNP genotyping was performed with use of bead array technology. One hundred and forty-four SNPs (selected from HapMap) within thirty genes associated with fracture-healing were investigated. Three SNPs did not segregate in the population and were excluded from the analysis. Eight of the remaining SNPs failed the test for Hardy-Weinberg equilibrium (p value smaller than the Bonferroni-corrected level of 0.05/141 = 0.000355) and were excluded. Results: Five SNPs on four genes were found to have a p value of 1, indicating that the presence of the allele increased the risk of nonunion. The rs2853550 SNP, which had the largest effect (OR = 5.9, p = 0.034), was on the IL1B gene, which codes for interleukin 1 beta. The rs2297514 SNP (OR = 3.98, p = 0.015) and the rs2248814 SNP (OR = 2.27, p = 0.038) were on the NOS2 gene coding for nitric oxide synthase. The remaining two SNPs had an OR of <1, indicating that the presence of the allele may be protective against nonunion. The rs3819089 SNP (OR = 0.26, p = 0.026) was on the MMP13 gene for matrix metallopeptidase 13, and the rs270393 SNP (OR = 0.30, p = 0.015) was on the BMP6 gene for bone morphogenetic protein 6. Conclusions: Variations in the IL1B and NOS2 genes may contribute to delayed fracture-healing and warrant further investigation. Clinical Relevance: Impaired fracture union may have genetic contributions. This article was updated on September 10, 2014, because of a previous error. On page 1242, in the byline, and on page 1247, in the author addresses, the academic degree for Henry J. Donahue had previously read “MD.” The degree now reads “PhD.”...


  • Open Access

    Intraoperative angioembolization in the management of pelvic-fracture related hemodynamic instability

    by Robert A Cherry, David C Goodspeed, Frank C Lynch, John Delgado, Spence J Reid

    This case series report discusses patients presenting with hemorrhage and hemodymanic compromise due to severe pelvic fractures and undergoing intraoperative angioembolization (IAE) with other resuscitative procedures.