Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures
- 1 October 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 29 (10) , e364-e370
Abstract
Objectives: The biomechanical difficulty in fixation of a Vancouver B1 periprosthetic fracture is purchase of the proximal femoral segment in the presence of the hip stem. Several newer technologies provide the ability to place bicortical locking screws tangential to the hip stem with much longer lengths of screw purchase compared with unicortical screws. This biomechanical study compares the stability of 2 of these newer constructs to previous methods. Methods: Thirty composite synthetic femurs were prepared with cemented hip stems. The distal femur segment was osteotomized, and plates were fixed proximally with either (1) cerclage cables, (2) locked unicortical screws, (3) a composite of locked screws and cables, or tangentially directed bicortical locking screws using either (4) a stainless steel locking compression plate system with a Locking Attachment Plate (Synthes) or (5) a titanium alloy Non-Contact Bridging system (Zimmer). Specimens were tested to failure in either axial or torsional quasistatic loading modes (n = 3) after 20 moderate load preconditioning cycles. Stiffness, maximum force, and failure mechanism were determined. Results: Bicortical constructs resisted higher (by an average of at least 27%) maximum forces than the other 3 constructs in torsional loading (P < 0.05). Cables constructs exhibited lower maximum force than all other constructs, in both axial and torsional loading. The bicortical titanium construct was stiffer than the bicortical stainless steel construct in axial loading. Conclusions: Proximal fixation stability is likely improved with the use of bicortical locking screws as compared with traditional unicortical screws and cable techniques. In this study with a limited sample size, we found the addition of cerclage cables to unicortical screws may not offer much improvement in biomechanical stability of unstable B1 fractures.Keywords
This publication has 27 references indexed in Scilit:
- Cement-in-Cement Revision for Selected Vancouver Type B1 Femoral Periprosthetic Fractures: A Biomechanical AnalysisThe Journal of Arthroplasty, 2013
- Biomechanical performance of different cable and wire cerclage configurationsInternational Orthopaedics, 2012
- The locking attachment plate for proximal fixation of periprosthetic femur fractures—a biomechanical comparison of two techniquesInternational Orthopaedics, 2012
- The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both?Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2011
- Biomechanical Comparison of 2 Different Locking Plate Fixation Methods in Vancouver B1 Periprosthetic Femur FracturesGeriatric Orthopaedic Surgery & Rehabilitation, 2011
- Periprosthetic fracture fixation of the femur following total hip arthroplasty: A review of biomechanical testingClinical Biomechanics, 2011
- Treatment of periprosthetic femoral fractures with two different minimal invasive angle-stable plates: Biomechanical comparison studies on cadaveric bonesInjury, 2010
- Fracture and Dislocation Classification Compendium - 2007Journal of Orthopaedic Trauma, 2007
- A biomechanical study comparing cortical onlay allograft struts and plates in the treatment of periprosthetic femoral fracturesClinical Biomechanics, 2005
- The effect of muscle loading on the simulation of bone remodelling in the proximal femurJournal of Biomechanics, 2005