Janet E. Stout
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Janet E. Stout has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Julianne L. Baron
University of Pittsburgh
4 shared publications- Julianne L. Baron
Affiliation Special Pathogens Laboratory, Pittsburgh, PA, United States of America
3 shared publications Marilyn M. Wagener
School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA
3 shared publicationsScott Duda
Special Pathogens Laboratory, 1401 Forbes Ave., Suite 209, Pittsburgh, PA, 15219, USA
3 shared publications- David M. Pierre
Special Pathogens Laboratory, Pittsburgh, PA 15219, USA
2 shared publications - Julianne L. Baron
Special Pathogens Laboratory, Pittsburgh, PA 15219, USA
2 shared publications
Latest Publications
- Open Access
- 9 January 2023
- Published by Elsevier in Tuberculosis
- Vol. 139, 102305
Environmental risk of nontuberculous mycobacterial infection: Strategies for advancing methodology
- 9 January 2023
- Published by Elsevier in Tuberculosis
- Vol. 139, 102305
Open AccessEnvironmental risk of nontuberculous mycobacterial infection: Strategies for advancing methodology
- Open Access
- 3 March 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16  (3) , e0247166
Evaluation of a new culture medium for isolation of nontuberculous mycobacteria from environmental water samples
Nontuberculous mycobacteria (NTM) are waterborne pathogens commonly found in building water systems where they are a primary concern to vulnerable patient populations and can cause severe disease. The recovery of NTM from environmental samples can be a laborious undertaking and current pre-treatment methods and selective media lack sensitivity. We explored the use of the highly selective Rapidly Growing Mycobacteria (RGM) medium for culturing NTM from environmental water samples compared to existing methods. In total, 223 environmental water samples, including potable and non-potable water, were cultured for NTM using three culture media. In addition to direct culture on RGM medium, each sample was cultured on Middlebrook 7H10 medium and Mitchison 7H11 medium after pre-treatment with 0.2M KCl-HCl. Additionally, 33 distinct species of NTM were inoculated onto RGM medium and 7H10 medium in parallel to directly compare their growth. The use of RGM medium alone without pre-treatment provided a sensitivity (91%) comparable to that offered by culture on both 7H10 and 7H11 with acid pretreatment (combined sensitivity; 86%) with significantly less overgrowth and interference from other organisms on RGM medium. The average concentration of NTM observed on RGM medium alone was comparable to or greater than the NTM concentration on either medium alone or combined. Thirty-three species were examined in parallel and all tested strains of 27 of these species successfully grew on RGM medium, including 19 of 21 from the CDCâs healthcare-associated infections species list. RGM medium was successful at recovering environmental NTM without a pre-treatment, greatly reducing labor and materials required to process samples. Simplification of culture processing for environmental NTM will allow for a better assessment of their presence in building water systems and the potential for reduced exposure of susceptible populations.
- 3 March 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16  (3) , e0247166
Open AccessEvaluation of a new culture medium for isolation of nontuberculous mycobacteria from environmental water samples
Nontuberculous mycobacteria (NTM) are waterborne pathogens commonly found in building water systems where they are a primary concern to vulnerable patient populations and can cause severe disease. The recovery of NTM from environmental samples can be a laborious undertaking and current pre-treatment methods and selective media lack sensitivity. We explored the use of the highly selective Rapidly Growing Mycobacteria (RGM) medium for culturing NTM from environmental water samples compared to existing methods. In total, 223 environmental water samples, including potable and non-potable water, were cultured for NTM using three culture media. In addition to direct culture on RGM medium, each sample was cultured on Middlebrook 7H10 medium and Mitchison 7H11 medium after pre-treatment with 0.2M KCl-HCl. Additionally, 33 distinct species of NTM were inoculated onto RGM medium and 7H10 medium in parallel to directly compare their growth. The use of RGM medium alone without pre-treatment provided a sensitivity (91%) comparable to that offered by culture on both 7H10 and 7H11 with acid pretreatment (combined sensitivity; 86%) with significantly less overgrowth and interference from other organisms on RGM medium. The average concentration of NTM observed on RGM medium alone was comparable to or greater than the NTM concentration on either medium alone or combined. Thirty-three species were examined in parallel and all tested strains of 27 of these species successfully grew on RGM medium, including 19 of 21 from the CDCâs healthcare-associated infections species list. RGM medium was successful at recovering environmental NTM without a pre-treatment, greatly reducing labor and materials required to process samples. Simplification of culture processing for environmental NTM will allow for a better assessment of their presence in building water systems and the potential for reduced exposure of susceptible populations.
- Open Access
- 2 March 2021
- Published by Oxford University Press (OUP) in Letters in Applied Microbiology
- Vol. 72  (6) , 750-756
Crossâreactivity of the IDEXX Legiolert method with other Gramânegative bacteria and waterborne pathogens leads to falseâpositive assay results
Legionella species are the causative agent of Legionnairesâ disease, a potentially fatal bacterial pneumonia. New regulations and standards have prioritized the development of water safety plans to minimize the growth and spread of Legionella species in buildings. To determine the presence and type of Legionella in a water system, microbiological culturing is the gold standard method. However, recently new methodologies have been developed that claim to be sensitive and specific for Legionella at the genus or L. pneumophila at the species level. Published and anecdotal reports suggest that one of these newer cultureâbased, enzymeâsubstrate methods, the IDEXX Legiolert test, may exhibit false positivity with other microbes common to water sources. We experimentally evaluated the IDEXX Legiolert method using these other waterborne bacteria including Elizabethkingia meningoseptica, Pseudomonas aeruginosa, Proteus mirabilis and Serratia marcescens at realâworld environmental concentrations. We saw falseâpositive results for the Legiolert test with several of these organisms, at sample concentrations as low as 60 CFU per ml. Falseâpositive Legionella results can trigger costly remediation and waterâuse restrictions, that may be implemented while waiting for additional, confirmatory microbiological testing that could, in this case, yield no L. pneumophila.
- 2 March 2021
- Published by Oxford University Press (OUP) in Letters in Applied Microbiology
- Vol. 72  (6) , 750-756
Open AccessCrossâreactivity of the IDEXX Legiolert method with other Gramânegative bacteria and waterborne pathogens leads to falseâpositive assay results
Legionella species are the causative agent of Legionnairesâ disease, a potentially fatal bacterial pneumonia. New regulations and standards have prioritized the development of water safety plans to minimize the growth and spread of Legionella species in buildings. To determine the presence and type of Legionella in a water system, microbiological culturing is the gold standard method. However, recently new methodologies have been developed that claim to be sensitive and specific for Legionella at the genus or L. pneumophila at the species level. Published and anecdotal reports suggest that one of these newer cultureâbased, enzymeâsubstrate methods, the IDEXX Legiolert test, may exhibit false positivity with other microbes common to water sources. We experimentally evaluated the IDEXX Legiolert method using these other waterborne bacteria including Elizabethkingia meningoseptica, Pseudomonas aeruginosa, Proteus mirabilis and Serratia marcescens at realâworld environmental concentrations. We saw falseâpositive results for the Legiolert test with several of these organisms, at sample concentrations as low as 60 CFU per ml. Falseâpositive Legionella results can trigger costly remediation and waterâuse restrictions, that may be implemented while waiting for additional, confirmatory microbiological testing that could, in this case, yield no L. pneumophila.
- Open Access
- 11 November 2020
- Published by MDPI AG in Microorganisms
- Vol. 8  (11) , 1770
Evaluation of Recommended Water Sample Collection Methods and the Impact of Holding Time on Legionella Recovery and Variability from Healthcare Building Water Systems
Water safety and management programs (WSMP) utilize field measurements to evaluate control limits and monitor water quality parameters including Legionella presence. This monitoring is important to verify that the plan is being implemented properly. However, once it has been determined when and how to sample for Legionella, it is important to choose appropriate collection and processing methods. We sought to compare processing immediate and flushed samples, filtration of different volumes collected, and sample hold times. Hot water samples were collected immediately and after a 2-min flush. These samples were plated directly and after filtration of either 100 mL, 200 mL, or 1 L. Additionally, unflushed samples were collected and processed immediately and after 1, 24, and 48 h of hold time. We found that flushed samples had significant reductions in Legionella counts compared to immediate samples. Processing 100 mL of that immediate sample both directly and after filter concentration yielded the highest concentration and percent sample positivity, respectively. We also show that there was no difference in culture values from time 0 compared to hold times of 1 h and 24 h. At 48 h, there were slightly fewer Legionella recovered than at time 0. However, Legionella counts were so variable based on sampling location and date that this hold time effect was minimal. The interpretation of Legionella culture results depends on the sample collection and processing methods used, as these can have a huge impact on the success of sampling and the validation of control measures.
- 11 November 2020
- Published by MDPI AG in Microorganisms
- Vol. 8  (11) , 1770
Open AccessEvaluation of Recommended Water Sample Collection Methods and the Impact of Holding Time on Legionella Recovery and Variability from Healthcare Building Water Systems
Water safety and management programs (WSMP) utilize field measurements to evaluate control limits and monitor water quality parameters including Legionella presence. This monitoring is important to verify that the plan is being implemented properly. However, once it has been determined when and how to sample for Legionella, it is important to choose appropriate collection and processing methods. We sought to compare processing immediate and flushed samples, filtration of different volumes collected, and sample hold times. Hot water samples were collected immediately and after a 2-min flush. These samples were plated directly and after filtration of either 100 mL, 200 mL, or 1 L. Additionally, unflushed samples were collected and processed immediately and after 1, 24, and 48 h of hold time. We found that flushed samples had significant reductions in Legionella counts compared to immediate samples. Processing 100 mL of that immediate sample both directly and after filter concentration yielded the highest concentration and percent sample positivity, respectively. We also show that there was no difference in culture values from time 0 compared to hold times of 1 h and 24 h. At 48 h, there were slightly fewer Legionella recovered than at time 0. However, Legionella counts were so variable based on sampling location and date that this hold time effect was minimal. The interpretation of Legionella culture results depends on the sample collection and processing methods used, as these can have a huge impact on the success of sampling and the validation of control measures.
- 9 March 2020
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 6  (5) , 1324-1335
Bacterial community structure correlates with Legionella pneumophila colonization of New York City high rise building premises plumbing systems
Complex building premises plumbing systems provide an ideal niche for diverse waterborne microorganisms, including opportunistic pathogens such as Legionella pneumophila. In this field study, we collected cold and hot water samples from premises plumbing systems of nine different high-rise buildings and examined the L. pneumophila culturable positivity and concentration to examine microbial ecology trends associated with L. pneumophila colonization. In addition, bacterial community structure was evaluated using high throughput 16S rRNA gene sequencing. 9.1% (2/22) of cold-water samples and 30.5% (18/59) of hot water samples were positive for L. pneumophila culture. 16S rRNA gene sequencing demonstrated a diverse bacterial community in the sampled premises plumbing systems. The phyla Proteobacteria, Acidobacteria, Bacteroidetes, Gemmatimonadetes, Planctomycetes, and Thermi represented a combined 97.7% average relative abundance, dominating the bacterial community. Also, an apparent bacterial community difference was observed between cold water and hot water. Interestingly, by examining cold water and hot water separately, we identified several bacterial taxa in the phyla Bacteroidetes, Gemmatimonadetes, and Acidobacteria were significantly enriched in L. pneumophila culture positive samples, while taxa in Proteobacteria were significantly enriched in L. pneumophila culture negative water samples. The correlation of L. pneumophila colonization and bacterial community structure suggests a potential association between this waterborne opportunistic pathogen and the premises plumbing microbial community, which merits further research.
- 9 March 2020
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 6  (5) , 1324-1335
Bacterial community structure correlates with Legionella pneumophila colonization of New York City high rise building premises plumbing systems
Complex building premises plumbing systems provide an ideal niche for diverse waterborne microorganisms, including opportunistic pathogens such as Legionella pneumophila. In this field study, we collected cold and hot water samples from premises plumbing systems of nine different high-rise buildings and examined the L. pneumophila culturable positivity and concentration to examine microbial ecology trends associated with L. pneumophila colonization. In addition, bacterial community structure was evaluated using high throughput 16S rRNA gene sequencing. 9.1% (2/22) of cold-water samples and 30.5% (18/59) of hot water samples were positive for L. pneumophila culture. 16S rRNA gene sequencing demonstrated a diverse bacterial community in the sampled premises plumbing systems. The phyla Proteobacteria, Acidobacteria, Bacteroidetes, Gemmatimonadetes, Planctomycetes, and Thermi represented a combined 97.7% average relative abundance, dominating the bacterial community. Also, an apparent bacterial community difference was observed between cold water and hot water. Interestingly, by examining cold water and hot water separately, we identified several bacterial taxa in the phyla Bacteroidetes, Gemmatimonadetes, and Acidobacteria were significantly enriched in L. pneumophila culture positive samples, while taxa in Proteobacteria were significantly enriched in L. pneumophila culture negative water samples. The correlation of L. pneumophila colonization and bacterial community structure suggests a potential association between this waterborne opportunistic pathogen and the premises plumbing microbial community, which merits further research.
- 1 February 2020
- Published by Elsevier in American Journal of Infection Control
- Vol. 48  (2) , 132-138
Point-of-use filters for prevention of health careâacquired Legionnairesâ disease: Field evaluation of a new filter product and literature review
- 1 February 2020
- Published by Elsevier in American Journal of Infection Control
- Vol. 48  (2) , 132-138
Point-of-use filters for prevention of health careâacquired Legionnairesâ disease: Field evaluation of a new filter product and literature review
- Open Access
Water Quality as a Predictor of Legionella Positivity of Building Water Systems
Testing drinking water systems for the presence of Legionella colonization is a proactive approach to assess and reduce the risk of Legionnairesâ disease. Previous studies suggest that there may be a link between Legionella positivity in the hot water return line or certain water quality parameters (temperature, free chlorine residual, etc.) with distal site Legionella positivity. It has been suggested that these measurements could be used as a surrogate for testing for Legionella in building water systems. We evaluated the relationship between hot water return line Legionella positivity and other water quality parameters and Legionella colonization in premise plumbing systems by testing 269 samples from domestic cold and hot water samples in 28 buildings. The hot water return line Legionella positivity and distal site positivity only demonstrated a 77.8% concordance rate. Hot water return line Legionella positivity compared to distal site positivity had a sensitivity of 55% and a specificity of 96%. There was poor correlation and a low positive predictive value between the hot water return line and distal outlet positivity. There was no correlation between Legionella distal site positivity and total bacteria (heterotrophic plate count), pH, free chlorine, calcium, magnesium, zinc, manganese, copper, temperature, total organic carbon, or incoming cold-water chlorine concentration. These findings suggest that hot water return line Legionella positivity and other water quality parameters are not predictive of distal site positivity and should not be used alone to determine the buildingâs Legionella colonization rate and effectiveness of water management programs.
Open AccessWater Quality as a Predictor of Legionella Positivity of Building Water Systems
Testing drinking water systems for the presence of Legionella colonization is a proactive approach to assess and reduce the risk of Legionnairesâ disease. Previous studies suggest that there may be a link between Legionella positivity in the hot water return line or certain water quality parameters (temperature, free chlorine residual, etc.) with distal site Legionella positivity. It has been suggested that these measurements could be used as a surrogate for testing for Legionella in building water systems. We evaluated the relationship between hot water return line Legionella positivity and other water quality parameters and Legionella colonization in premise plumbing systems by testing 269 samples from domestic cold and hot water samples in 28 buildings. The hot water return line Legionella positivity and distal site positivity only demonstrated a 77.8% concordance rate. Hot water return line Legionella positivity compared to distal site positivity had a sensitivity of 55% and a specificity of 96%. There was poor correlation and a low positive predictive value between the hot water return line and distal outlet positivity. There was no correlation between Legionella distal site positivity and total bacteria (heterotrophic plate count), pH, free chlorine, calcium, magnesium, zinc, manganese, copper, temperature, total organic carbon, or incoming cold-water chlorine concentration. These findings suggest that hot water return line Legionella positivity and other water quality parameters are not predictive of distal site positivity and should not be used alone to determine the buildingâs Legionella colonization rate and effectiveness of water management programs.
- Open Access
- 29 August 2017
- Published by Springer Nature in Annals of Clinical Microbiology and Antimicrobials
- Vol. 16  (1) , 1-4
Diagnostic testing for Legionnairesâ disease
Legionnairesâ disease is commonly diagnosed clinically using a urinary antigen test. The urinary antigen test is highly accurate for L. pneumophila serogroup 1, however other diagnostic tests should also be utilized in conjunction with the urinary antigen as many other Legionella species and serogroups are pathogenic. Culturing of patient specimens remains the gold standard for diagnosis of Legionnairesâ disease. Selective media, BYCE with the addition of antibiotics, allows for a high sensitivity and specificity. Culturing can identify all species and serogroups of Legionella. A major benefit of culturing is that it provides the recovery of a patient isolate, which can be used to find an environmental match. Other diagnostic tests, including DFA and molecular tests such as PCR and LAMP, are useful tests to supplement culturing. Molecular tests provide much more rapid results in comparison to culture, however these tests should not be a primary diagnostic tool given their lower sensitivity and specificity in comparison to culturing. It is recommended that all laboratories develop the ability to culture patient specimens in-house with the selective media.
- 29 August 2017
- Published by Springer Nature in Annals of Clinical Microbiology and Antimicrobials
- Vol. 16  (1) , 1-4
Open AccessDiagnostic testing for Legionnairesâ disease
Legionnairesâ disease is commonly diagnosed clinically using a urinary antigen test. The urinary antigen test is highly accurate for L. pneumophila serogroup 1, however other diagnostic tests should also be utilized in conjunction with the urinary antigen as many other Legionella species and serogroups are pathogenic. Culturing of patient specimens remains the gold standard for diagnosis of Legionnairesâ disease. Selective media, BYCE with the addition of antibiotics, allows for a high sensitivity and specificity. Culturing can identify all species and serogroups of Legionella. A major benefit of culturing is that it provides the recovery of a patient isolate, which can be used to find an environmental match. Other diagnostic tests, including DFA and molecular tests such as PCR and LAMP, are useful tests to supplement culturing. Molecular tests provide much more rapid results in comparison to culture, however these tests should not be a primary diagnostic tool given their lower sensitivity and specificity in comparison to culturing. It is recommended that all laboratories develop the ability to culture patient specimens in-house with the selective media.
- 3 June 2015
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 187  (7) , 1-10
Lack of correlation between Legionella colonization and microbial population quantification using heterotrophic plate count and adenosine triphosphate bioluminescence measurement
This investigation compared biological quantification of potable and non-potable (cooling) water samples using pour plate heterotrophic plate count (HPC) methods and adenosine triphosphate (ATP) concentration measurement using bioluminescence. The relationship between these measurements and the presence of Legionella spp. was also examined. HPC for potable and non-potable water were cultured on R2A and PCA, respectively. Results indicated a strong correlation between HPC and ATP measurements in potable water (R = 0.90, p < 0.001). In the make-up water and two cooling towers, the correlations between ATP and HPC were much weaker but statistically significant (make-up water: R = 0.37, p = 0.005; cooling tower 1: R = 0.52, p < 0.001; cooling tower 2: R = 0.54, p < 0.001). For potable and non-potable samples, HPC exhibited higher measurement variability than ATP. However, ATP measurements showed higher microbial concentrations than HPC measurements. Following chlorination of the cooling towers, ATP measurements indicated very low bacterial concentrations (1000 CFU/mL) which consisted primarily of non-tuberculous mycobacteria. HPC concentrations have been suggested to be predictive of Legionella presence, although this has not been proven. Our evaluation showed that HPC or ATP demonstrated a fair predictive capacity for Legionella positivity in potable water (HPC: receiver operating characteristic (ROC) = 0.70; ATP: ROC = 0.78; p = 0.003). However, HPC or ATP correctly classified sites as positive only 64 and 62 % of the time, respectively. No correlation between HPC or ATP and Legionella colonization in non-potable water samples was found (HPC: ROC = 0.28; ATP: ROC = 0.44; p = 0.193).
- 3 June 2015
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 187  (7) , 1-10
Lack of correlation between Legionella colonization and microbial population quantification using heterotrophic plate count and adenosine triphosphate bioluminescence measurement
This investigation compared biological quantification of potable and non-potable (cooling) water samples using pour plate heterotrophic plate count (HPC) methods and adenosine triphosphate (ATP) concentration measurement using bioluminescence. The relationship between these measurements and the presence of Legionella spp. was also examined. HPC for potable and non-potable water were cultured on R2A and PCA, respectively. Results indicated a strong correlation between HPC and ATP measurements in potable water (R = 0.90, p < 0.001). In the make-up water and two cooling towers, the correlations between ATP and HPC were much weaker but statistically significant (make-up water: R = 0.37, p = 0.005; cooling tower 1: R = 0.52, p < 0.001; cooling tower 2: R = 0.54, p < 0.001). For potable and non-potable samples, HPC exhibited higher measurement variability than ATP. However, ATP measurements showed higher microbial concentrations than HPC measurements. Following chlorination of the cooling towers, ATP measurements indicated very low bacterial concentrations (1000 CFU/mL) which consisted primarily of non-tuberculous mycobacteria. HPC concentrations have been suggested to be predictive of Legionella presence, although this has not been proven. Our evaluation showed that HPC or ATP demonstrated a fair predictive capacity for Legionella positivity in potable water (HPC: receiver operating characteristic (ROC) = 0.70; ATP: ROC = 0.78; p = 0.003). However, HPC or ATP correctly classified sites as positive only 64 and 62 % of the time, respectively. No correlation between HPC or ATP and Legionella colonization in non-potable water samples was found (HPC: ROC = 0.28; ATP: ROC = 0.44; p = 0.193).
- 1 May 2015
- Published by Elsevier in Systematic and Applied Microbiology
- Vol. 38  (3) , 198-205
Effect of monochloramine treatment on the microbial ecology of Legionella and associated bacterial populations in a hospital hot water system
- 1 May 2015
- Published by Elsevier in Systematic and Applied Microbiology
- Vol. 38  (3) , 198-205
Effect of monochloramine treatment on the microbial ecology of Legionella and associated bacterial populations in a hospital hot water system