Takahiro Tanaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takahiro Tanaka has a total of 302 co-authors. Here are the top co-authors by number of shared publications:
H. Tanaka
Department of Physics, Sophia University, Tokyo 102-8554, Japan
37 shared publications- Masashi Kitajima
Institute of Science Tokyo 2 , 2-12-1-W4-5 Ookayama, Meguro-ku, Tokyo 152-8551
34 shared publications - Yusuke Tamenori
Japan Synchrotron Radiation Research Institute, Sayo, Japan
27 shared publications - Kiyoshi Ueda
Institute of Atomic and Molecular Physics and Jilin Provincial Key Laboratory of Applied Atomic and Molecular Spectroscopy, Jilin University, Changchun, China
26 shared publications M. Hoshino
Department of Physics, Sophia University, Tokyo 102-8554, Japan
25 shared publications- Norio Saito
RIKEN SPring-8 Center, Hyogo 679-5148, Japan
22 shared publications
Latest Publications
- Open Access
- 30 October 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (1) , 011001
Perspectives of the generation and measurement of small electric currents
This paper provides a comprehensive overview of the historical background, current status, and future prospects related to the generation and measurement of small electric currents. It specifically caters to nonprofessional readers, with the aim of making the information comprehensible. A range of technologies are introduced, applicable in both basic research and industrial context. Quantum-mechanical approaches have been the focus of extensive efforts in this field, encompassing various types of single-electron pumps and combinations of two other quantum standards: the Josephson voltage standard and the quantized Hall resistance standard. These methods offer a reliable and precise means of generating and measuring small electric currents, minimizing uncertainties. However, operating complex cryogenic systems requires specialized expertise. Alternatively, conventional room-temperature systems are comparatively easier to handle. They employ low-noise amplifiers in conjunction with stable high-value resistors or capacitors charged with voltage ramps. This paper not only examines the characteristics of the both quantum and classical approaches from multiple perspectives but also outlines current and future applications for the generation and measurement of small electric currents.
- 30 October 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (1) , 011001
Open AccessPerspectives of the generation and measurement of small electric currents
This paper provides a comprehensive overview of the historical background, current status, and future prospects related to the generation and measurement of small electric currents. It specifically caters to nonprofessional readers, with the aim of making the information comprehensible. A range of technologies are introduced, applicable in both basic research and industrial context. Quantum-mechanical approaches have been the focus of extensive efforts in this field, encompassing various types of single-electron pumps and combinations of two other quantum standards: the Josephson voltage standard and the quantized Hall resistance standard. These methods offer a reliable and precise means of generating and measuring small electric currents, minimizing uncertainties. However, operating complex cryogenic systems requires specialized expertise. Alternatively, conventional room-temperature systems are comparatively easier to handle. They employ low-noise amplifiers in conjunction with stable high-value resistors or capacitors charged with voltage ramps. This paper not only examines the characteristics of the both quantum and classical approaches from multiple perspectives but also outlines current and future applications for the generation and measurement of small electric currents.
- Open Access
- 10 May 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (4) , 662-670
Harmonic radiation contribution and X-ray transmission at the Small Quantum Systems instrument of European XFEL
Transmission measurements of the soft X-ray beamline to the Small Quantum Systems (SQS) scientific instrument at the SASE3 undulator of European XFEL are presented. Measurements are reported for a wide range of photon energies (650 eV to 2400 eV), using X-ray gas monitors as well as a bolometric radiometer. The results are in good agreement with simulations for the beam transport and show a transmission of up to 80% over the whole photon energy range. The contribution of second- and third-harmonic radiation of the soft X-ray undulator is determined at selected photon energies by performing transmission measurements using a gas absorber to provide variable attenuation of the incoming photon flux. A comparison of the results with semi-analytic calculations for the generation of free-electron laser pulses in the SASE3 undulator reveals an influence of apertures along the beam transport on the exact harmonic content to be accounted for at the experiment. The second-harmonic content is measured to be in the range of 0.1% to 0.3%, while the third-harmonic contributed a few percent to the SASE3 emission. For experiments at the SQS instrument, these numbers can be reduced through specific selections of the mirror reflection angles.
- 10 May 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (4) , 662-670
Open AccessHarmonic radiation contribution and X-ray transmission at the Small Quantum Systems instrument of European XFEL
Transmission measurements of the soft X-ray beamline to the Small Quantum Systems (SQS) scientific instrument at the SASE3 undulator of European XFEL are presented. Measurements are reported for a wide range of photon energies (650 eV to 2400 eV), using X-ray gas monitors as well as a bolometric radiometer. The results are in good agreement with simulations for the beam transport and show a transmission of up to 80% over the whole photon energy range. The contribution of second- and third-harmonic radiation of the soft X-ray undulator is determined at selected photon energies by performing transmission measurements using a gas absorber to provide variable attenuation of the incoming photon flux. A comparison of the results with semi-analytic calculations for the generation of free-electron laser pulses in the SASE3 undulator reveals an influence of apertures along the beam transport on the exact harmonic content to be accounted for at the experiment. The second-harmonic content is measured to be in the range of 0.1% to 0.3%, while the third-harmonic contributed a few percent to the SASE3 emission. For experiments at the SQS instrument, these numbers can be reduced through specific selections of the mirror reflection angles.
- 1 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Subfemtoampere Resolved Ionization Current Measurements Using a High-Resistance Transimpedance Amplifier
In low-dose-rate dosimetry using ionization chambers, the predominant component in the uncertainty budget is a measurement uncertainty of current at a measurement range of around 10 fA. To improve this, in this article, we report on the development of a system for measuring a small ionization current based on a transimpedance amplifier utilizing a high-resistance feedback resistor. In this amplifier, we used a feedback resistor of 1 $\text{T}\Omega $ made of a metalized glaze thick film, which has clear traceability to a resistance standard. In addition, the nonlinear current-to-voltage profile of the feedback resistor and its contribution to the measurement uncertainty were carefully evaluated. Type-A uncertainty well below 1 fA can be achieved within a practical measurement time shorter than an hour. As a result, current measurements with relative expanded uncertainty from 0.1 % to 2 % were demonstrated for the ionization currents ranging from sub-fA to sub-pA generated by a 137 Cs gamma-ray source. This transimpedance amplifier with high-resistance feedback is appropriate for low-dose-rate radiation dosimetry needed for medical and environmental monitoring applications.
- 1 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Subfemtoampere Resolved Ionization Current Measurements Using a High-Resistance Transimpedance Amplifier
In low-dose-rate dosimetry using ionization chambers, the predominant component in the uncertainty budget is a measurement uncertainty of current at a measurement range of around 10 fA. To improve this, in this article, we report on the development of a system for measuring a small ionization current based on a transimpedance amplifier utilizing a high-resistance feedback resistor. In this amplifier, we used a feedback resistor of 1 $\text{T}\Omega $ made of a metalized glaze thick film, which has clear traceability to a resistance standard. In addition, the nonlinear current-to-voltage profile of the feedback resistor and its contribution to the measurement uncertainty were carefully evaluated. Type-A uncertainty well below 1 fA can be achieved within a practical measurement time shorter than an hour. As a result, current measurements with relative expanded uncertainty from 0.1 % to 2 % were demonstrated for the ionization currents ranging from sub-fA to sub-pA generated by a 137 Cs gamma-ray source. This transimpedance amplifier with high-resistance feedback is appropriate for low-dose-rate radiation dosimetry needed for medical and environmental monitoring applications.
- 18 April 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11776, 20
Power meters and fluorescence intensity monitors as intensity diagnostics in the LCLS-II X-ray instruments
For LCLS-II, we have developed fluorescence intensity monitors and power meters as intensity monitors. The Fluorescence Intensity Monitor (FIM) provides the non-invasive, pulse-by-pulse normalization of experiments. For the LCLS-II instruments, the diagnostic was constructed with an array of four microchannel plate assemblies and four avalanche photodiodes. The diagnostics are being installed in each Kirkpatrick Baez mirror chamber. The noise of the diagnostic will be evaluated against a goal of 1 %. The X-ray power meter delivers average power values. For the LCLS-II instruments, a power meter was selected compatible with high average power. In the LCLS-II instruments, power meters are being installed with each profile monitor in order to evaluate the transmission along the X-ray transport. A calibration of a set of power meters was carried out against a gas monitor detector at FLASH. In addition for all the power meters, a relative calibration was performed with a visible light source. At the endstations, a power meter will determined the pulse energy at the sample.
- 18 April 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11776, 20
Power meters and fluorescence intensity monitors as intensity diagnostics in the LCLS-II X-ray instruments
For LCLS-II, we have developed fluorescence intensity monitors and power meters as intensity monitors. The Fluorescence Intensity Monitor (FIM) provides the non-invasive, pulse-by-pulse normalization of experiments. For the LCLS-II instruments, the diagnostic was constructed with an array of four microchannel plate assemblies and four avalanche photodiodes. The diagnostics are being installed in each Kirkpatrick Baez mirror chamber. The noise of the diagnostic will be evaluated against a goal of 1 %. The X-ray power meter delivers average power values. For the LCLS-II instruments, a power meter was selected compatible with high average power. In the LCLS-II instruments, power meters are being installed with each profile monitor in order to evaluate the transmission along the X-ray transport. A calibration of a set of power meters was carried out against a gas monitor detector at FLASH. In addition for all the power meters, a relative calibration was performed with a visible light source. At the endstations, a power meter will determined the pulse energy at the sample.
- Open Access
- 23 October 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (6) , 2081-2085
Transmission measurement at the Bernina branch of the Aramis Beamline of SwissFEL
The transmission of the optical components of the Bernina branch of the Aramis beamline at SwissFEL has been measured with an X-ray gas monitor from DESY and compared with a PSI gas detector upstream of the optical components. The transmission efficiencies of the Mo, Si and SiC mirror coatings of the Aramis beamline and the various other in-beam components were evaluated and compared with theoretical calculations, showing an agreement of 6% or better in all cases. The experiment has also shown the efficacy of the high-harmonic rejection mirrors at the Bernina branch of the Aramis beamline at SwissFEL, and characterized the transmission efficiency of the on-line spectrometer in the Aramis beamline. The theoretical transmission of the mirror coatings match the experimental data to within 7%. The accuracy of these measurements was checked against a radiative bolometer from a Japanese collaboration and found to agree to a level of 4% or better. Further comparisons with a diamond detector from a US-based inter-institute collaboration demonstrated a good agreement for the attenuator settings of the beamline.
- 23 October 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (6) , 2081-2085
Open AccessTransmission measurement at the Bernina branch of the Aramis Beamline of SwissFEL
The transmission of the optical components of the Bernina branch of the Aramis beamline at SwissFEL has been measured with an X-ray gas monitor from DESY and compared with a PSI gas detector upstream of the optical components. The transmission efficiencies of the Mo, Si and SiC mirror coatings of the Aramis beamline and the various other in-beam components were evaluated and compared with theoretical calculations, showing an agreement of 6% or better in all cases. The experiment has also shown the efficacy of the high-harmonic rejection mirrors at the Bernina branch of the Aramis beamline at SwissFEL, and characterized the transmission efficiency of the on-line spectrometer in the Aramis beamline. The theoretical transmission of the mirror coatings match the experimental data to within 7%. The accuracy of these measurements was checked against a radiative bolometer from a Japanese collaboration and found to agree to a level of 4% or better. Further comparisons with a diamond detector from a US-based inter-institute collaboration demonstrated a good agreement for the attenuator settings of the beamline.
- 24 April 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11038, 34
Pulse power measurements and attenuator characterization of the hard X-ray beamline at the Linac Coherent Light Source
The absolute power of the Linac Coherent Light Source pulses has been measured accurately in the hard X-ray beamline by using simultaneously two detectors: an X-ray Gas Monitor Detector (XGMD) in tandem with a radiometer. From these measurements, we were also able to characterize and calibrate in details our sets of beamline attenuators, in addition to extending an absolute calibration for our beamline intensity monitors. Similarly, we demonstrate that commercial optical power meter has a response in the hard X-ray regime, that can be cross-correlated with the absolute power of the LCLS beam.
- 24 April 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11038, 34
Pulse power measurements and attenuator characterization of the hard X-ray beamline at the Linac Coherent Light Source
The absolute power of the Linac Coherent Light Source pulses has been measured accurately in the hard X-ray beamline by using simultaneously two detectors: an X-ray Gas Monitor Detector (XGMD) in tandem with a radiometer. From these measurements, we were also able to characterize and calibrate in details our sets of beamline attenuators, in addition to extending an absolute calibration for our beamline intensity monitors. Similarly, we demonstrate that commercial optical power meter has a response in the hard X-ray regime, that can be cross-correlated with the absolute power of the LCLS beam.
- Open Access
- 11 February 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (2) , 320-327
Measurement of the absolute number of photons of the hard X-ray beamline at the Linac Coherent Light Source
X-ray free-electron lasers provide intense pulses of coherent X-rays with a short pulse duration. These sources are chaotic by nature and therefore, to be used at their full potential, require that every X-ray pulse is characterized in terms of various relevant properties such as intensity, photon energy, position and timing. Diagnostics are for example installed on an X-ray beamline to specifically monitor the intensity of individual X-ray pulses. To date, these can however only provide a single-shot value of the relative number of photons per shot. Here are reported measurements made in January 2015 of the absolute number of photons in the hard X-ray regime at LCLS which is typically 3.5 × 1011 photons shot−1 between 6 and 9.5 keV at the X-ray Pump–Probe instrument. Moreover, an average transmission of ≈62% of the hard X-ray beamline over this energy range is measured and the third-harmonic content of ≈0.47% below 9 keV is characterized.
- 11 February 2019
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 26 (2) , 320-327
Open AccessMeasurement of the absolute number of photons of the hard X-ray beamline at the Linac Coherent Light Source
X-ray free-electron lasers provide intense pulses of coherent X-rays with a short pulse duration. These sources are chaotic by nature and therefore, to be used at their full potential, require that every X-ray pulse is characterized in terms of various relevant properties such as intensity, photon energy, position and timing. Diagnostics are for example installed on an X-ray beamline to specifically monitor the intensity of individual X-ray pulses. To date, these can however only provide a single-shot value of the relative number of photons per shot. Here are reported measurements made in January 2015 of the absolute number of photons in the hard X-ray regime at LCLS which is typically 3.5 × 1011 photons shot−1 between 6 and 9.5 keV at the X-ray Pump–Probe instrument. Moreover, an average transmission of ≈62% of the hard X-ray beamline over this energy range is measured and the third-harmonic content of ≈0.47% below 9 keV is characterized.
- 1 June 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 894, 107-110
Absolute laser-intensity measurement and online monitor calibration using a calorimeter at a soft X-ray free-electron laser beamline in SACLA
- 1 June 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 894, 107-110
Absolute laser-intensity measurement and online monitor calibration using a calorimeter at a soft X-ray free-electron laser beamline in SACLA
- 15 November 2017
- Published by Optica Publishing Group in Optics Letters
- Vol. 42 (22) , 4776-4779
Compact bolometric radiometer for free-electron lasers in a wavelength range from extreme-ultraviolet to x-rays
A reliable diagnostic device for free-electron lasers (FELs) is essential for both users and the evaluation of FEL sources and beamline optics. Here, we propose a compact bolometric radiometer (CBR) that can operate at room temperature. The CBR is mainly designed for FELs in the wavelength range from the extreme-ultraviolet (EUV) to x-rays; moreover, we confirmed that the proposed device can also be applied to synchrotron radiation. As an application of the CBR, we evaluated an FEL beamline transmission by means of bolometric technique in the EUV range for the first time, to the best of our knowledge. This indicates that the CBR is an effective diagnostic device for FELs.
- 15 November 2017
- Published by Optica Publishing Group in Optics Letters
- Vol. 42 (22) , 4776-4779
Compact bolometric radiometer for free-electron lasers in a wavelength range from extreme-ultraviolet to x-rays
A reliable diagnostic device for free-electron lasers (FELs) is essential for both users and the evaluation of FEL sources and beamline optics. Here, we propose a compact bolometric radiometer (CBR) that can operate at room temperature. The CBR is mainly designed for FELs in the wavelength range from the extreme-ultraviolet (EUV) to x-rays; moreover, we confirmed that the proposed device can also be applied to synchrotron radiation. As an application of the CBR, we evaluated an FEL beamline transmission by means of bolometric technique in the EUV range for the first time, to the best of our knowledge. This indicates that the CBR is an effective diagnostic device for FELs.
- 1 October 2017
- Published by Elsevier in Journal of Electron Spectroscopy and Related Phenomena
- Vol. 220, 3-5
An accumulation mode of a room-temperature calorimeter for total pulse energy measurement of X-ray FELs
- 1 October 2017
- Published by Elsevier in Journal of Electron Spectroscopy and Related Phenomena
- Vol. 220, 3-5
An accumulation mode of a room-temperature calorimeter for total pulse energy measurement of X-ray FELs