Latest Publications

  • Open Access

    Perspectives of the generation and measurement of small electric currents

    by Nobu-Hisa Kaneko, Takahiro Tanaka, Yuma Okazaki Okazaki

    This paper provides a comprehensive overview of the historical background, current status, and future prospects related to the generation and measurement of small electric currents. It specifically caters to nonprofessional readers, with the aim of making the information comprehensible. A range of technologies are introduced, applicable in both basic research and industrial context. Quantum-mechanical approaches have been the focus of extensive efforts in this field, encompassing various types of single-electron pumps and combinations of two other quantum standards: the Josephson voltage standard and the quantized Hall resistance standard. These methods offer a reliable and precise means of generating and measuring small electric currents, minimizing uncertainties. However, operating complex cryogenic systems requires specialized expertise. Alternatively, conventional room-temperature systems are comparatively easier to handle. They employ low-noise amplifiers in conjunction with stable high-value resistors or capacitors charged with voltage ramps. This paper not only examines the characteristics of the both quantum and classical approaches from multiple perspectives but also outlines current and future applications for the generation and measurement of small electric currents.


  • Open Access

    Harmonic radiation contribution and X-ray transmission at the Small Quantum Systems instrument of European XFEL

    by Thomas M. Baumann, Rebecca Boll, Alberto De Fanis, Patrik Grychtol, Markus Ilchen, Ulf Fini Jastrow, Masahiro Kato, Christoph Lechner, Theophilos Maltezopoulos, Tommaso Mazza, et al.

    Transmission measurements of the soft X-ray beamline to the Small Quantum Systems (SQS) scientific instrument at the SASE3 undulator of European XFEL are presented. Measurements are reported for a wide range of photon energies (650 eV to 2400 eV), using X-ray gas monitors as well as a bolometric radiometer. The results are in good agreement with simulations for the beam transport and show a transmission of up to 80% over the whole photon energy range. The contribution of second- and third-harmonic radiation of the soft X-ray undulator is determined at selected photon energies by performing transmission measurements using a gas absorber to provide variable attenuation of the incoming photon flux. A comparison of the results with semi-analytic calculations for the generation of free-electron laser pulses in the SASE3 undulator reveals an influence of apertures along the beam transport on the exact harmonic content to be accounted for at the experiment. The second-harmonic content is measured to be in the range of 0.1% to 0.3%, while the third-harmonic contributed a few percent to the SASE3 emission. For experiments at the SQS instrument, these numbers can be reduced through specific selections of the mirror reflection angles.


  • Subfemtoampere Resolved Ionization Current Measurements Using a High-Resistance Transimpedance Amplifier

    by Yuma Okazaki, Takahiro Tanaka, Norio Saito, Nobu-Hisa Kaneko

    In low-dose-rate dosimetry using ionization chambers, the predominant component in the uncertainty budget is a measurement uncertainty of current at a measurement range of around 10 fA. To improve this, in this article, we report on the development of a system for measuring a small ionization current based on a transimpedance amplifier utilizing a high-resistance feedback resistor. In this amplifier, we used a feedback resistor of 1 $\text{T}\Omega $ made of a metalized glaze thick film, which has clear traceability to a resistance standard. In addition, the nonlinear current-to-voltage profile of the feedback resistor and its contribution to the measurement uncertainty were carefully evaluated. Type-A uncertainty well below 1 fA can be achieved within a practical measurement time shorter than an hour. As a result, current measurements with relative expanded uncertainty from 0.1 % to 2 % were demonstrated for the ionization currents ranging from sub-fA to sub-pA generated by a 137 Cs gamma-ray source. This transimpedance amplifier with high-resistance feedback is appropriate for low-dose-rate radiation dosimetry needed for medical and environmental monitoring applications.


  • Power meters and fluorescence intensity monitors as intensity diagnostics in the LCLS-II X-ray instruments

    by Philip A. Heimann, Stefan P. Moeller, Matthew H. Seaberg, Peter Walter, William F. Schlotter, David Fritz, Andrey Sorokin, Fini Jastrow, Kai Tiedtke, Takahiro Tanaka

    For LCLS-II, we have developed fluorescence intensity monitors and power meters as intensity monitors. The Fluorescence Intensity Monitor (FIM) provides the non-invasive, pulse-by-pulse normalization of experiments. For the LCLS-II instruments, the diagnostic was constructed with an array of four microchannel plate assemblies and four avalanche photodiodes. The diagnostics are being installed in each Kirkpatrick Baez mirror chamber. The noise of the diagnostic will be evaluated against a goal of 1 %. The X-ray power meter delivers average power values. For the LCLS-II instruments, a power meter was selected compatible with high average power. In the LCLS-II instruments, power meters are being installed with each profile monitor in order to evaluate the transmission along the X-ray transport. A calibration of a set of power meters was carried out against a gas monitor detector at FLASH. In addition for all the power meters, a relative calibration was performed with a visible light source. At the endstations, a power meter will determined the pulse energy at the sample.

  • Open Access

    Transmission measurement at the Bernina branch of the Aramis Beamline of SwissFEL

    by Pavle Juranic, Kai Tiedtke, Shigeki Owada, Takahiro Tanaka, Ulf Jastrow, Andrey Sorokin, Luc Patthey, Roman Mankowsky, Markus Degenhardt, Yunieski Arbelo, et al.

    The transmission of the optical components of the Bernina branch of the Aramis beamline at SwissFEL has been measured with an X-ray gas monitor from DESY and compared with a PSI gas detector upstream of the optical components. The transmission efficiencies of the Mo, Si and SiC mirror coatings of the Aramis beamline and the various other in-beam components were evaluated and compared with theoretical calculations, showing an agreement of 6% or better in all cases. The experiment has also shown the efficacy of the high-harmonic rejection mirrors at the Bernina branch of the Aramis beamline at SwissFEL, and characterized the transmission efficiency of the on-line spectrometer in the Aramis beamline. The theoretical transmission of the mirror coatings match the experimental data to within 7%. The accuracy of these measurements was checked against a radiative bolometer from a Japanese collaboration and found to agree to a level of 4% or better. Further comparisons with a diamond detector from a US-based inter-institute collaboration demonstrated a good agreement for the attenuator settings of the beamline.


  • Pulse power measurements and attenuator characterization of the hard X-ray beamline at the Linac Coherent Light Source

    by Sanghoon Song, Roberto Alonso-Mori, Matthieu Chollet, Yiping Feng, James M. Glownia, Henrik T. Lemke, Marcin Sikorski, Diling Zhu, Stefan P. Moeller, Hae Ja Lee, et al.

    The absolute power of the Linac Coherent Light Source pulses has been measured accurately in the hard X-ray beamline by using simultaneously two detectors: an X-ray Gas Monitor Detector (XGMD) in tandem with a radiometer. From these measurements, we were also able to characterize and calibrate in details our sets of beamline attenuators, in addition to extending an absolute calibration for our beamline intensity monitors. Similarly, we demonstrate that commercial optical power meter has a response in the hard X-ray regime, that can be cross-correlated with the absolute power of the LCLS beam.

  • Open Access

    Measurement of the absolute number of photons of the hard X-ray beamline at the Linac Coherent Light Source

    by Sanghoon Song, Roberto Alonso-Mori, Matthieu Chollet, Yiping Feng, James M. Glownia, Henrik T. Lemke, Marcin Sikorski, Diling Zhu, Stefan Moeller, Hae Ja Lee, et al.

    X-ray free-electron lasers provide intense pulses of coherent X-rays with a short pulse duration. These sources are chaotic by nature and therefore, to be used at their full potential, require that every X-ray pulse is characterized in terms of various relevant properties such as intensity, photon energy, position and timing. Diagnostics are for example installed on an X-ray beamline to specifically monitor the intensity of individual X-ray pulses. To date, these can however only provide a single-shot value of the relative number of photons per shot. Here are reported measurements made in January 2015 of the absolute number of photons in the hard X-ray regime at LCLS which is typically 3.5 × 1011 photons shot−1 between 6 and 9.5 keV at the X-ray Pump–Probe instrument. Moreover, an average transmission of ≈62% of the hard X-ray beamline over this energy range is measured and the third-harmonic content of ≈0.47% below 9 keV is characterized.


  • Compact bolometric radiometer for free-electron lasers in a wavelength range from extreme-ultraviolet to x-rays

    by Takahiro Tanaka, Masahiro Kato, Norio Saito, Shigeki Owada, Kensuke Tono, Makina Yabashi, Tetsuya Ishikawa

    A reliable diagnostic device for free-electron lasers (FELs) is essential for both users and the evaluation of FEL sources and beamline optics. Here, we propose a compact bolometric radiometer (CBR) that can operate at room temperature. The CBR is mainly designed for FELs in the wavelength range from the extreme-ultraviolet (EUV) to x-rays; moreover, we confirmed that the proposed device can also be applied to synchrotron radiation. As an application of the CBR, we evaluated an FEL beamline transmission by means of bolometric technique in the EUV range for the first time, to the best of our knowledge. This indicates that the CBR is an effective diagnostic device for FELs.