Kirpal Kohli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kirpal Kohli has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
A. Karvat
BC Cancer-Fraser Valley Centre, Surrey, BC
1 shared publication- Alexandra Bourgouin
National Research Council of Canada, Metrology Research Centre, 1200 Montreal Road, Ottawa, K1A0R6, ON, Canada
1 shared publication - Anand Karvat
Department of Radiation Oncology, Fraser Valley Center, BC Cancer Agency, 13750 96th Avenue, Surrey, V3V 1Z2, BC, Canada
1 shared publication - Ash Parameswaran
School of Engineering Science, Simon Fraser University, Burnaby, V5A1S6, BC, Canada
1 shared publication Brige Paul Chugh
1 shared publication- Bryan R. Muir
National Research Council Canada
1 shared publication
Latest Publications
- 29 December 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (1) , 015019
Calorimeter measurements of absolute dose in aluminum, a surrogate of bone, to validate dose-to-medium in Acuros XB
Objective . While the accuracy of dose calculations in water with Acuros XB is well established, experimental validation of dose in bone is limited. Acuros XB reports both dose-to-medium and dose-to-water, and these values differ in bone, but there are no reports of measurements of validation in bone. This work compares Acuros XB calculations to measurements of absolute dose in aluminum (medium similar to bone). The validity of using selected relative dosimeters in aluminum is also investigated. Approach . A calorimeter with an aluminum core embedded in an aluminum phantom was selected as bone surrogate for the measurement of absolute dose. Matching the medium of the core to the medium of the phantom allowed eliminating the calculation of the conversion between media. The dose was measured at the fixed depth of 3.3 cm in aluminum (∼9 g·cm −2 ) with 6X, 10X, 6FFF and 10FFF photon beams from a TrueBeam Varian linac. In addition, experimental cross-calibration between water and aluminum was performed for an IBA CC13 ionization chamber, a PTW microDiamond and EBT3 Gafchromic film. Main results . Calculations with Acuros XB dose-to-medium in aluminum differed from the calorimetry data by −2.8% to −3.5%, depending on the beam. Use of dose-to-water would have resulted in about 39% discrepancy. The cross calibration coefficient between water and aluminum yielded values of about 0.87 for the CC13 chamber, 0.91 for the microDiamond, and 0.88 for the film, and independent of the beam within about ±1%. Significance . It was demonstrated the value of the dose-to-medium in aluminum (surrogate of bone) computed with Acuros XB is close to the value of the absolute dose measured with a calorimeter, and there is a significant discrepancy when dose-to-water is used instead. The use of an ionization chamber, a microDiamond and Gafchromic film in aluminum required a considerable correction from calibration in water.
- 29 December 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (1) , 015019
Calorimeter measurements of absolute dose in aluminum, a surrogate of bone, to validate dose-to-medium in Acuros XB
Objective . While the accuracy of dose calculations in water with Acuros XB is well established, experimental validation of dose in bone is limited. Acuros XB reports both dose-to-medium and dose-to-water, and these values differ in bone, but there are no reports of measurements of validation in bone. This work compares Acuros XB calculations to measurements of absolute dose in aluminum (medium similar to bone). The validity of using selected relative dosimeters in aluminum is also investigated. Approach . A calorimeter with an aluminum core embedded in an aluminum phantom was selected as bone surrogate for the measurement of absolute dose. Matching the medium of the core to the medium of the phantom allowed eliminating the calculation of the conversion between media. The dose was measured at the fixed depth of 3.3 cm in aluminum (∼9 g·cm −2 ) with 6X, 10X, 6FFF and 10FFF photon beams from a TrueBeam Varian linac. In addition, experimental cross-calibration between water and aluminum was performed for an IBA CC13 ionization chamber, a PTW microDiamond and EBT3 Gafchromic film. Main results . Calculations with Acuros XB dose-to-medium in aluminum differed from the calorimetry data by −2.8% to −3.5%, depending on the beam. Use of dose-to-water would have resulted in about 39% discrepancy. The cross calibration coefficient between water and aluminum yielded values of about 0.87 for the CC13 chamber, 0.91 for the microDiamond, and 0.88 for the film, and independent of the beam within about ±1%. Significance . It was demonstrated the value of the dose-to-medium in aluminum (surrogate of bone) computed with Acuros XB is close to the value of the absolute dose measured with a calorimeter, and there is a significant discrepancy when dose-to-water is used instead. The use of an ionization chamber, a microDiamond and Gafchromic film in aluminum required a considerable correction from calibration in water.
- Open Access
- 1 June 2018
- Published by MDPI AG in Current Oncology
- Vol. 25 (3) , 193-199
A Bioimpedance Analysis of Head-and-neck Cancer Patients Undergoing Radiotherapy
Malnutrition is a frequent manifestation in patients with head-and-neck cancer undergoing radiation therapy and a major contributor to morbidity and mortality. Thus, body composition is an important component of an overall evaluation of nutrition in cancer patients. Malnutrition is characterized by weight loss, loss of muscle mass, changes in cell membrane integrity, and alterations in fluid balance. Bioelectrical impedance analysis is a method to analyze body composition and includes parameters such as intracellular water content, extracellular water content, and cell membrane integrity in the form of a phase angle (Φ). Bioelectrical impedance analysis has consistently been shown to have prognostic value with respect to mortality and morbidity in patients undergoing chemotherapy. The goal of the present study was to evaluate the relationship between Φ, time, intracellular water content, and weight for head-and-neck cancer patients undergoing radiotherapy. The results demonstrate that Φ decreases with time and increases with intracellular water content and weight.
- 1 June 2018
- Published by MDPI AG in Current Oncology
- Vol. 25 (3) , 193-199
Open AccessA Bioimpedance Analysis of Head-and-neck Cancer Patients Undergoing Radiotherapy
Malnutrition is a frequent manifestation in patients with head-and-neck cancer undergoing radiation therapy and a major contributor to morbidity and mortality. Thus, body composition is an important component of an overall evaluation of nutrition in cancer patients. Malnutrition is characterized by weight loss, loss of muscle mass, changes in cell membrane integrity, and alterations in fluid balance. Bioelectrical impedance analysis is a method to analyze body composition and includes parameters such as intracellular water content, extracellular water content, and cell membrane integrity in the form of a phase angle (Φ). Bioelectrical impedance analysis has consistently been shown to have prognostic value with respect to mortality and morbidity in patients undergoing chemotherapy. The goal of the present study was to evaluate the relationship between Φ, time, intracellular water content, and weight for head-and-neck cancer patients undergoing radiotherapy. The results demonstrate that Φ decreases with time and increases with intracellular water content and weight.
- Open Access
- 14 October 2014
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 13 (1) , 1-18
Prototype development of an electrical impedance based simultaneous respiratory and cardiac monitoring system for gated radiotherapy
In radiotherapy, temporary translocations of the internal organs and tumor induced by respiratory and cardiac activities can undesirably lead to significantly lower radiation dose on the targeted tumor but more harmful radiation on surrounding healthy tissues. Respiratory and cardiac gated radiotherapy offers a potential solution for the treatment of tumors located in the upper thorax. The present study focuses on the design and development of simultaneous acquisition of respiratory and cardiac signal using electrical impedance technology for use in dual gated radiotherapy. An electronic circuitry was developed for monitoring the bio-impedance change due to respiratory and cardiac motions and extracting the cardiogenic ECG signal. The system was analyzed in terms of reliability of signal acquisition, time delay, and functionality in a high energy radiation environment. The resulting signal of the system developed was also compared with the output of the commercially available Real-time Position Management™ (RPM) system in both time and frequency domains. The results demonstrate that the bioimpedance-based method can potentially provide reliable tracking of respiratory and cardiac motion in humans, alternative to currently available methods. When compared with the RPM system, the impedance-based system developed in the present study shows similar output pattern but different sensitivities in monitoring different respiratory rates. The tracking of cardiac motion was more susceptible to interference from other sources than respiratory motion but also provided synchronous output compared with the ECG signal extracted. The proposed hardware-based implementation was observed to have a worst-case time delay of approximately 33 ms for respiratory monitoring and 45 ms for cardiac monitoring. No significant effect on the functionality of the system was observed when it was tested in a radiation environment with the electrode lead wires directly exposed to high-energy X-Rays. The developed system capable of rendering quality signals for tracking both respiratory and cardiac motions can potentially provide a solution for simultaneous dual-gated radiotherapy.
- 14 October 2014
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 13 (1) , 1-18
Open AccessPrototype development of an electrical impedance based simultaneous respiratory and cardiac monitoring system for gated radiotherapy
In radiotherapy, temporary translocations of the internal organs and tumor induced by respiratory and cardiac activities can undesirably lead to significantly lower radiation dose on the targeted tumor but more harmful radiation on surrounding healthy tissues. Respiratory and cardiac gated radiotherapy offers a potential solution for the treatment of tumors located in the upper thorax. The present study focuses on the design and development of simultaneous acquisition of respiratory and cardiac signal using electrical impedance technology for use in dual gated radiotherapy. An electronic circuitry was developed for monitoring the bio-impedance change due to respiratory and cardiac motions and extracting the cardiogenic ECG signal. The system was analyzed in terms of reliability of signal acquisition, time delay, and functionality in a high energy radiation environment. The resulting signal of the system developed was also compared with the output of the commercially available Real-time Position Management™ (RPM) system in both time and frequency domains. The results demonstrate that the bioimpedance-based method can potentially provide reliable tracking of respiratory and cardiac motion in humans, alternative to currently available methods. When compared with the RPM system, the impedance-based system developed in the present study shows similar output pattern but different sensitivities in monitoring different respiratory rates. The tracking of cardiac motion was more susceptible to interference from other sources than respiratory motion but also provided synchronous output compared with the ECG signal extracted. The proposed hardware-based implementation was observed to have a worst-case time delay of approximately 33 ms for respiratory monitoring and 45 ms for cardiac monitoring. No significant effect on the functionality of the system was observed when it was tested in a radiation environment with the electrode lead wires directly exposed to high-energy X-Rays. The developed system capable of rendering quality signals for tracking both respiratory and cardiac motions can potentially provide a solution for simultaneous dual-gated radiotherapy.
- 7 August 2014
- Published by Wiley in Medical Physics
- Vol. 41 (8) , 8
Poster — Thur Eve — 09: Evaluation of electrical impedance and computed tomography fusion algorithms using an anthropomorphic phantom
- 7 August 2014
- Published by Wiley in Medical Physics
- Vol. 41 (8) , 8
Poster — Thur Eve — 09: Evaluation of electrical impedance and computed tomography fusion algorithms using an anthropomorphic phantom