Fazel Boujan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fazel Boujan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Emilie M. M. Santos
Department of Radiology and Nuclear Medicine, Amsterdam UMC, Amsterdam, the Netherlands; Department of Biomedical Engineering and Physics, Amsterdam UMC, Amsterdam, the Netherlands; Department of Radiology and Nuclear Medicine, Erasmus Universtiy Medical Center, Rotterdam, the Netherlands; Department of Medical Informatics, Erasmus University Medical Center, Rotterdam, the Netherlands
1 shared publication Gerard Schouten
Philips Healthcare
1 shared publicationJean-Louis Dietemann
University Hospitals of Strasbourg
1 shared publicationLuc Mertz
University Hospitals of Strasbourg
1 shared publicationNicolas Clauss
University Hospitals of Strasbourg
1 shared publicationSjirk Boon
Philips Healthcare
1 shared publication
Latest Publications
- 17 August 2014
- Published by Springer Nature in Neuroradiology
- Vol. 56 (11) , 971-976
A new method of real-time skin dose visualization. Clinical evaluation of fluoroscopically guided interventions
We have conducted a prospective study to clinically evaluate a new radiation dose observing tool that displays patient’s peak skin dose (PSD) map in real time. The skin dose map (SDM) prototype quantifies the air kerma based on exposure parameters from the X-ray system. The accuracy of this prototype was evaluated with radiochromic films, which were used as a mean for PSD measurement. The SDM is a reliable tool that provides an accurate PSD estimation and location. SDM also has many advantages over the radiochromic films, such as real-time dose evaluation and easy access to critical operational parameters for physicians and technicians.
- 17 August 2014
- Published by Springer Nature in Neuroradiology
- Vol. 56 (11) , 971-976
A new method of real-time skin dose visualization. Clinical evaluation of fluoroscopically guided interventions
We have conducted a prospective study to clinically evaluate a new radiation dose observing tool that displays patient’s peak skin dose (PSD) map in real time. The skin dose map (SDM) prototype quantifies the air kerma based on exposure parameters from the X-ray system. The accuracy of this prototype was evaluated with radiochromic films, which were used as a mean for PSD measurement. The SDM is a reliable tool that provides an accurate PSD estimation and location. SDM also has many advantages over the radiochromic films, such as real-time dose evaluation and easy access to critical operational parameters for physicians and technicians.