GSGuilherme Paula Pinto Schettino

Guilherme Paula Pinto Schettino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Guilherme Paula Pinto Schettino has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Kinetics of arterial carbon dioxide during veno-venous extracorporeal membrane oxygenation support in an apnoeic porcine model

    by Pedro Vitale Mendes, Marcelo Park, Alexandre Toledo Maciel, Débora Prudêncio e Silva, Natalia Friedrich, Edzangela Vasconcelos Santos Barbosa, Adriana Sayuri Hirota, Guilherme Pinto Paula Schettino, Luciano Cesar Pontes Azevedo, Eduardo Leite Vieira Costa

    Extracorporeal membrane oxygenation (ECMO) is a technique widely used worldwide to improve gas exchange. Changes in ECMO settings affect both oxygen and carbon dioxide. The impact on oxygenation can be followed closely by continuous pulse oximeter. Conversely, carbon dioxide equilibrates much slower and is not usually monitored directly. We investigated the time to stabilization of arterial carbon dioxide partial pressure (PaCO2) following step changes in ECMO settings in 5 apnoeic porcine models under veno-venous ECMO support with polymethylpentene membranes. We collected sequential arterial blood gases at a pre-specified interval of 50 min using a sequence of standardized blood and sweep gas flow combinations. Following the changes in ECMO parameters, the kinetics of carbon dioxide was dependent on sweep gas and ECMO blood flow. With a blood flow of 1500 mL/min, PaCO2 takes longer than 50 min to equilibrate following the changes in sweep gas flow. Furthermore, the sweep gas flow from 3.0 to 10.0 L/min did not significantly affect PaCO2. However, with a blood flow of 3500 mL/min, 50 min was enough for PaCO2 to reach the equilibrium and every increment of sweep gas flow (up to 10.0 L/min) resulted in additional reductions of PaCO2. Fifty minutes was enough to reach the equilibrium of PaCO2 after ECMO initiation or after changes in blood and sweep gas flow with an ECMO blood flow of 3500 ml/min. Longer periods may be necessary with lower ECMO blood flows.


  • Open Access

    Sepsis-related deaths in Brazil: an analysis of the national mortality registry from 2002 to 2010

    by Leandro U Taniguchi, Ana Luiza Bierrenbach, Cristiana M Toscano, Guilherme Pp Schettino, Luciano Cp Azevedo

    Introduction: Limited population-based epidemiologic information about sepsis’ demography, including its mortality and temporal changes is available from developing countries. We investigated the epidemiology of sepsis deaths in Brazil using secondary data from the Brazilian Mortality Information System. Methods: Retrospective descriptive analysis of Brazilian multiple-cause-of-death data between 2002 and 2010, with sepsis-associated International Classification of Diseases, 10th Revision (ICD-10) code indicated as the cause of death. Population-based sepsis associated mortality rates and trends were estimated. Annual population-based mortality rates were calculated using age-stratified population estimates from the 2010 census provided by the Brazilian Institute of Geography and Statistics as denominators. Results: The total number of annual deaths recorded in Brazil increased over the decade, from 982,294 deaths reported in 2002 to 1,133,761 deaths reported in 2010. The number of sepsis associated deaths also increased both in absolute numbers and proportions from 95,972 (9.77% of total deaths) in 2002 to 186,712 deaths (16.46%) in 2010. The age-adjusted rate of sepsis-associated mortality increased from 69.5 deaths per 100,000 to 97.8 deaths per 100,000 population from 2002 to 2010 (P <0.001). Sepsis-associated mortality was higher in individuals older than 60 years of age as compared to subjects aged 0 to 20 years (adjusted rate ratio 15.7 (95% confidence interval (CI) 15.6 to 15.8)) and in male subjects (1.15 (95% CI 1.15 to 1.16)). Conclusions: Between 2002 and 2010 the contribution of sepsis to all cause mortality as reported in multiple-cause-of-death forms increased significantly in Brazil. Age-adjusted mortality rates by sepsis also increased in the last decade. Our results confirm the importance of sepsis as a significant healthcare issue in Brazil.


  • Open Access

    Pulmonary capillary pressure in pulmonary hypertension

    by Rogerio Souza, Marcelo Britto Passos Amato, Sergio Eduardo Demarzo, Daniel Deheinzelin, Carmen Silvia Valente Barbas, Guilherme Paula Pinto Schettino, Carlos Roberto Ribeiro Carvalho

    Introduction: Pulmonary capillary pressure (PCP), together with the time constants of the various vascular compartments, define the dynamics of the pulmonary vascular system. Our objective in the present study was to estimate PCPs and time constants of the vascular system in patients with idiopathic pulmonary arterial hypertension (IPAH), and compare them with these measures in patients with acute respiratory distress syndrome (ARDS). Methods: We conducted the study in two groups of patients with pulmonary hypertension: 12 patients with IPAH and 11 with ARDS. Four methods were used to estimate the PCP based on monoexponential and biexponential fitting of pulmonary artery pressure decay curves. Results: PCPs in the IPAH group were considerably greater than those in the ARDS group. The PCPs measured using the four methods also differed significantly, suggesting that each method measures the pressure at a different site in the pulmonary circulation. The time constant for the slow component of the biexponential fit in the IPAH group was significantly longer than that in the ARDS group. Conclusion: The PCP in IPAH patients is greater than normal but methodological limitations related to the occlusion technique may limit interpretation of these data in isolation. Different disease processes may result in different times for arterial emptying, with resulting implications for the methods available for estimating PCP.