Andrea Magnani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrea Magnani has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Eraldo Occhetta
Clinica Cardiologica A.O.U. Maggiore della Carità, Novara, Italy
3 shared publications Gabriella Francalacci
3 shared publicationsEmanuela Facchini
2 shared publicationsLaura Plebani
2 shared publications- Miriam Bortnik
Cardiology Division, Azienda Ospedaliera Universitaria Maggiore della Carità, Corso Mazzini 18, 28100 Novara, Italy
2 shared publications Paolo Marino
2 shared publications
Latest Publications
- Open Access
- 31 July 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (12) , 1767-1771
Lack of interference of electromagnetic navigation bronchoscopy to implanted cardioverter-defibrillator: in-vivo study
Electromagnetic navigation bronchoscopy (ENB) (Superdimension) is a diagnostic and therapeutic tool in patients with lung lesions. Very small data are available about potential interference of ENB magnetic field to implanted cardioverter-defibrillators (ICDs) and any documentation of ICD behaviour if a ventricular tachyarrhythmia occurs during ENB is lacking. We tested a number of selected ICDs to assess if any interference occurs by ENB magnetic field on detection of clinical ventricular fibrillation and shock delivery. Thirteen patients undergoing an ICD implantation or elective replacement with a clinical indication to assess the efficacy of defibrillation underwent: (i) real-time telemetric recording from ICD during ENB activation to detect possible noise; (ii) defibrillation test during exposure to ENB board-generated magnetic field. All tested ICDs showed no noise detection at maximum sensitivity level. Induced ventricular fibrillation was correctly detected and cured by implanted device. No change in programmed ICD parameters was induced by exposure to ENB magnetic field. All tested ICDs correctly operated and rescued the patients from induced ventricular fibrillation during ENB. Electromagnetic navigation bronchoscopy appears to be safe in heart patients with an ICD; however, close cardiac monitoring of these patients during ENB must be ensured as correct behaviour of all existing ICDs can only be presumed from compliance of the manufacturer to International Standards which establish procedures for electromagnetic interference checking on implantable devices on different ranges of frequency.
- 31 July 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (12) , 1767-1771
Open AccessLack of interference of electromagnetic navigation bronchoscopy to implanted cardioverter-defibrillator: in-vivo study
Electromagnetic navigation bronchoscopy (ENB) (Superdimension) is a diagnostic and therapeutic tool in patients with lung lesions. Very small data are available about potential interference of ENB magnetic field to implanted cardioverter-defibrillators (ICDs) and any documentation of ICD behaviour if a ventricular tachyarrhythmia occurs during ENB is lacking. We tested a number of selected ICDs to assess if any interference occurs by ENB magnetic field on detection of clinical ventricular fibrillation and shock delivery. Thirteen patients undergoing an ICD implantation or elective replacement with a clinical indication to assess the efficacy of defibrillation underwent: (i) real-time telemetric recording from ICD during ENB activation to detect possible noise; (ii) defibrillation test during exposure to ENB board-generated magnetic field. All tested ICDs showed no noise detection at maximum sensitivity level. Induced ventricular fibrillation was correctly detected and cured by implanted device. No change in programmed ICD parameters was induced by exposure to ENB magnetic field. All tested ICDs correctly operated and rescued the patients from induced ventricular fibrillation during ENB. Electromagnetic navigation bronchoscopy appears to be safe in heart patients with an ICD; however, close cardiac monitoring of these patients during ENB must be ensured as correct behaviour of all existing ICDs can only be presumed from compliance of the manufacturer to International Standards which establish procedures for electromagnetic interference checking on implantable devices on different ranges of frequency.
- 1 October 2006
- Vol. 7 (10) , 695-701
[Electrical storms in patients with implantable cardioverter-defibrillator: incidence and clinical management].
Electrical storm in implantable cardioverter-defibrillator (ICD) recipients is a dramatic experience for the patient and a hard emergency for the cardiology team. The aim of our study was to evaluate the incidence and the clinical significance of electrical storm in a standard population of ICD patients. We considered retrospectively 262 consecutive ICD patients (86% males, mean age 65+/-10.7 years). Patients were divided into three groups: 88 patients without appropriate ICD therapy (group A); 140 patients with isolated ICD therapies (group B); 34 patients with electrical storm episodes (> or = 3 appropriate ICD therapies/24 h) (group C). Survival study (endpoint death) was performed for each group of patients. There was no difference in age, sex, heart disease, ejection fraction or NYHA functional class among the three groups. ICD implant was performed for secondary prevention in 79% of group C patients and in 74.3 % of group B patients, but only in 39.8 % of group A patients (p < 0.0001). Mean follow-up was 31.1+/-29.8 months in group A, 55.1+/-38 months in group B, and 71.1+/-51.7 months in group C. The endpoint was reached by 16 patients (18%) of group A, by 53 patients (38%) of group B, and by 20 patients (58%) of group C. Comparison of the survival curves of the three groups did not show significant differences. In group C patients, 54 electrical storm episodes were recorded (mean 1.5/patient). In our population of ICD patients, we observed electrical storm in 34 patients (12.9%). Survival in group with episodes of electrical storm was comparable to patients without electrical storm; thus, in our experience, electrical storm could not represent a negative prognostic factor.
- 1 October 2006
- Vol. 7 (10) , 695-701
[Electrical storms in patients with implantable cardioverter-defibrillator: incidence and clinical management].
Electrical storm in implantable cardioverter-defibrillator (ICD) recipients is a dramatic experience for the patient and a hard emergency for the cardiology team. The aim of our study was to evaluate the incidence and the clinical significance of electrical storm in a standard population of ICD patients. We considered retrospectively 262 consecutive ICD patients (86% males, mean age 65+/-10.7 years). Patients were divided into three groups: 88 patients without appropriate ICD therapy (group A); 140 patients with isolated ICD therapies (group B); 34 patients with electrical storm episodes (> or = 3 appropriate ICD therapies/24 h) (group C). Survival study (endpoint death) was performed for each group of patients. There was no difference in age, sex, heart disease, ejection fraction or NYHA functional class among the three groups. ICD implant was performed for secondary prevention in 79% of group C patients and in 74.3 % of group B patients, but only in 39.8 % of group A patients (p < 0.0001). Mean follow-up was 31.1+/-29.8 months in group A, 55.1+/-38 months in group B, and 71.1+/-51.7 months in group C. The endpoint was reached by 16 patients (18%) of group A, by 53 patients (38%) of group B, and by 20 patients (58%) of group C. Comparison of the survival curves of the three groups did not show significant differences. In group C patients, 54 electrical storm episodes were recorded (mean 1.5/patient). In our population of ICD patients, we observed electrical storm in 34 patients (12.9%). Survival in group with episodes of electrical storm was comparable to patients without electrical storm; thus, in our experience, electrical storm could not represent a negative prognostic factor.
- 1 May 2004
- Vol. 5 (5) , 399-402
Twiddler's syndrome and pectoral stimulation in a patient with dual-site unipolar atrial pacing.
Twiddler's syndrome is a rare condition of pacemaker rotation; when associated with unipolar pacing it could provoke extracardiac muscular stimulation. We report a case of an obese woman who unintentionally reversed her triple-chamber, dual-site unipolar atrial pacemaker, implanted for the prevention of paroxysmal atrial fibrillation. The extracardiac pectoral stimulation was due to unipolar atrial stimulation. The polarity mode was not programmable and output reduction was unsuccessful. Thus, the problem was resolved noninvasively by means of external manual rotation of the pacer. At 24 months of follow-up, the patient was still free of symptoms.
- 1 May 2004
- Vol. 5 (5) , 399-402
Twiddler's syndrome and pectoral stimulation in a patient with dual-site unipolar atrial pacing.
Twiddler's syndrome is a rare condition of pacemaker rotation; when associated with unipolar pacing it could provoke extracardiac muscular stimulation. We report a case of an obese woman who unintentionally reversed her triple-chamber, dual-site unipolar atrial pacemaker, implanted for the prevention of paroxysmal atrial fibrillation. The extracardiac pectoral stimulation was due to unipolar atrial stimulation. The polarity mode was not programmable and output reduction was unsuccessful. Thus, the problem was resolved noninvasively by means of external manual rotation of the pacer. At 24 months of follow-up, the patient was still free of symptoms.
- 1 November 1991
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 14 (11) , 1828-1834
A New Approach to the Prevention of Endless Loop Tachycardia in DDD and VVD Pacing
- 1 November 1991
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 14 (11) , 1828-1834
A New Approach to the Prevention of Endless Loop Tachycardia in DDD and VVD Pacing