AMAndrea Magnani

Andrea Magnani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrea Magnani has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • EXTENT OF ACUTE CONTRACTILE RECOVERY DURING BIVENTRICULAR PACING IS NOT ASSOCIATED WITH LONG-TERM FOLLOW-UP IN HEART FAILURE PATIENTS WHO UNDERGO RESYNCHRONIZATION THERAPY

    by Federica De Vecchi, Chiara Cavallino, Virginia Di Ruocco, Emanuela Facchini, Eraldo Occhetta, Andrea Magnani, Paolo Marino

  • Open Access

    Lack of interference of electromagnetic navigation bronchoscopy to implanted cardioverter-defibrillator: in-vivo study

    by Andrea Magnani, Piero Balbo, Emanuela Facchini, Eraldo Occhetta, Paolo Marino

    Electromagnetic navigation bronchoscopy (ENB) (Superdimension) is a diagnostic and therapeutic tool in patients with lung lesions. Very small data are available about potential interference of ENB magnetic field to implanted cardioverter-defibrillators (ICDs) and any documentation of ICD behaviour if a ventricular tachyarrhythmia occurs during ENB is lacking. We tested a number of selected ICDs to assess if any interference occurs by ENB magnetic field on detection of clinical ventricular fibrillation and shock delivery. Thirteen patients undergoing an ICD implantation or elective replacement with a clinical indication to assess the efficacy of defibrillation underwent: (i) real-time telemetric recording from ICD during ENB activation to detect possible noise; (ii) defibrillation test during exposure to ENB board-generated magnetic field. All tested ICDs showed no noise detection at maximum sensitivity level. Induced ventricular fibrillation was correctly detected and cured by implanted device. No change in programmed ICD parameters was induced by exposure to ENB magnetic field. All tested ICDs correctly operated and rescued the patients from induced ventricular fibrillation during ENB. Electromagnetic navigation bronchoscopy appears to be safe in heart patients with an ICD; however, close cardiac monitoring of these patients during ENB must be ensured as correct behaviour of all existing ICDs can only be presumed from compliance of the manufacturer to International Standards which establish procedures for electromagnetic interference checking on implantable devices on different ranges of frequency.


    • 1 October 2006
      • Vol. 7  (10) , 695-701

    [Electrical storms in patients with implantable cardioverter-defibrillator: incidence and clinical management].

    by Paolo Devecchi, Laura Plebani, Eraldo Occhetta, Miriam Bortnik, Gabriella Francalacci, Andrea Magnani, Paolo Marino

    Electrical storm in implantable cardioverter-defibrillator (ICD) recipients is a dramatic experience for the patient and a hard emergency for the cardiology team. The aim of our study was to evaluate the incidence and the clinical significance of electrical storm in a standard population of ICD patients. We considered retrospectively 262 consecutive ICD patients (86% males, mean age 65+/-10.7 years). Patients were divided into three groups: 88 patients without appropriate ICD therapy (group A); 140 patients with isolated ICD therapies (group B); 34 patients with electrical storm episodes (> or = 3 appropriate ICD therapies/24 h) (group C). Survival study (endpoint death) was performed for each group of patients. There was no difference in age, sex, heart disease, ejection fraction or NYHA functional class among the three groups. ICD implant was performed for secondary prevention in 79% of group C patients and in 74.3 % of group B patients, but only in 39.8 % of group A patients (p < 0.0001). Mean follow-up was 31.1+/-29.8 months in group A, 55.1+/-38 months in group B, and 71.1+/-51.7 months in group C. The endpoint was reached by 16 patients (18%) of group A, by 53 patients (38%) of group B, and by 20 patients (58%) of group C. Comparison of the survival curves of the three groups did not show significant differences. In group C patients, 54 electrical storm episodes were recorded (mean 1.5/patient). In our population of ICD patients, we observed electrical storm in 34 patients (12.9%). Survival in group with episodes of electrical storm was comparable to patients without electrical storm; thus, in our experience, electrical storm could not represent a negative prognostic factor.


    • 1 May 2004
      • Vol. 5  (5) , 399-402

    Twiddler's syndrome and pectoral stimulation in a patient with dual-site unipolar atrial pacing.

    by Eraldo Occhetta, Miriam Bortnik, Gabriella Francalacci, Andrea Magnani, Laura Plebani, Corrado Vassanelli

    Twiddler's syndrome is a rare condition of pacemaker rotation; when associated with unipolar pacing it could provoke extracardiac muscular stimulation. We report a case of an obese woman who unintentionally reversed her triple-chamber, dual-site unipolar atrial pacemaker, implanted for the prevention of paroxysmal atrial fibrillation. The extracardiac pectoral stimulation was due to unipolar atrial stimulation. The polarity mode was not programmable and output reduction was unsuccessful. Thus, the problem was resolved noninvasively by means of external manual rotation of the pacer. At 24 months of follow-up, the patient was still free of symptoms.

  • A New Approach to the Prevention of Endless Loop Tachycardia in DDD and VVD Pacing

    by Giorgio Rognoni, Eraldo Occhetta, Antonello Perucca, Andrea Magnani, Gabriella Francalacci, Roberto Audoglio, Paolo Rossi