AGAxel Greiner

Axel Greiner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Axel Greiner has a total of 45 co-authors. Here are the top co-authors by number of shared publications:

  • Bianka Rubenbauer

    Department of Trauma-, Hand- and Plastic-Surgery, University Hospital of Munich, Campus Grosshadern, Marchioninistraße 15, 81377 Munich, Germany

    2 shared publications
  • Christian Kammerlander

    Department of General, Trauma and Reconstructive Surgery, University Hospital, LMU Munich, Munich, Germany

    2 shared publications
  • Christoph Linhart

    Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, LMU Munich, 80336 Munich, Germany

    2 shared publications
  • Christopher Alexander Becker

    Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany

    2 shared publications
  • Matthias Woiczinski

    Department of Orthopedic Surgery, Physical medicine and Rehabilitation, University Hospital, LMU Munich, Munich, Germany

    2 shared publications
  • Wolfgang Böcker

    Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital Munich, Ludwig-Maximilians-Universität München, Munich, Germany

    2 shared publications

Latest Publications

  • Open Access

    Micro-Structural and Biomechanical Evaluation of Bioresorbable and Conventional Bone Cements for Augmentation of the Proximal Femoral Nail

    by Christoph Linhart, Manuel Kistler, Maximilian Saller, Axel Greiner, Christopher Lampert, Matthias Kassube, Christopher A. Becker, Wolfgang Böcker, Christian Ehrnthaller

    Osteoporotic proximal femur fractures are on the rise due to demographic change. The most dominant surgical treatment option for per/subtrochanteric fractures is cephalomedullary nailing. As it has been shown to increase primary stability, cement augmentation has become increasingly popular in the treatment of osteoporotic per/subtrochanteric femur fractures. The ultimate goal is to achieve stable osteosynthesis, allowing for rapid full weight-bearing to reduce possible postoperative complications. In recent years, bioresorbable bone cements have been developed and are now mainly used to fill bone voids. The aim of this study was to evaluate the biomechanical stability as well as the micro-structural behaviour of bioresorbable bone cements compared to conventional polymethylmethacrylate (PMMA)-cements in a subtrochanteric femur fracture model. Biomechanical as well as micro-computed tomography morphology analysis revealed no significant differences in both bone cements, as they showed equal mechanical stability and tight interdigitation into the spongious bone of the femoral head. Given the positive risk/benefit ratio for bioresorbable bone cements, their utilisation should be evaluated in future clinical studies, making them a promising alternative to PMMA-bone cements.


  • Open Access

    Tape suture for stabilization of incomplete posterior pelvic ring fractures—biomechanical analysis of a new minimally invasive treatment for incomplete lateral compression pelvic ring fractures

    by Christopher Alexander Becker, Adrian Cavalcanti Kussmaul, Eduardo Manuel Suero, Markus Regauer, Matthias Woiczinski, Christian Braun, Wilhelm Flatz, Oliver Pieske, Christian Kammerlander, Wolfgang Boecker, et al.

    Background: Incomplete lateral compression fractures (including AO Type B2.1) are among the most common pelvic ring injuries. Although the treatment of choice remains controversial, sacroiliac (SI) screws are commonly used for the operative treatment of incomplete lateral compression fractures of the pelvic ring. However, the disadvantages of SI screws include the risk of nerve root or blood vessel injury. Recently, tape sutures have been found useful as stabilizing material for the treatment of injuries of the syndesmosis, the rotator cuff and knee ligaments. In this current study, we aimed to test the biomechanical feasibility of tape sutures to stabilize the pelvis in the setting of AO Type B2.1 injury. Methods: Six human cadaveric pelvises underwent cyclic loading to compare the biomechanical stability of different osteosynthesis methods in a B2.1 fracture model. The methods tested in this experiment were a FiberTape® suture and the currently established SI screw. A 3D ultrasound tracking system was used to measure fracture fragment motion. Linear regression was used to model displacement and stiffness at the posterior and anterior pelvic ring. Results: At the posterior fracture site, the FiberTape® demonstrated similar displacement (2.2 ± 0.8 mm) and stiffness (52.2 ± 18.0 N/mm) compared to the sacroiliac screw (displacement 2.1 ± 0.6 mm, P > 0.999; stiffness 50.8 ± 13.0 N/mm, P > 0.999). Considering the anterior fracture site, the FiberTape® again demonstrated similar displacement (3.8 ± 1.3 mm) and stiffness (29.5 ± 9.0 N/mm) compared to the sacroiliac screw (displacement 2.9 ± 0.8 mm, P = 0.2196; stiffness 37.5 ± 11.5 N/mm, P = 0.0711). Conclusion: The newly presented osteosynthesis, the FiberTape®, shows promising results for the stabilization of the posterior pelvic ring in AO Type B2.1 lateral compression fractures compared to a sacroiliac screw osteosynthesis based on its minimal-invasiveness and the statistically similar biomechanical properties.


  • Open Access

    Modified less invasive anterior subcutaneous fixator for unstable Tile-C-pelvic ring fractures: a biomechanical study

    by Christopher A. Becker, Christian Kammerlander, Adrian Cavalcanti Kußmaul, Matthias Woiczinski, Christoph Thorwächter, Christian Zeckey, Fabian Sommer, Christoph Linhart, Simon Weidert, Eduardo M. Suero, et al.

    Operative procedures for unstable pelvic ring fractures remain controversially discussed. Minimally invasive treatment options for pelvic ring fractures have several benefits for the patient. But they can also provide disadvantages. Anterior subcutaneous pelvic fixation (INFIX) has shown promising biomechanical results in pelvic ring fractures, but there is a high complication rate of nerve injuries. An additional screw to the INFIX seems to be more stable. The aim of this study is to compare biomechanical stability of a new modified unilateral INFIX fixing the unilateral injured pelvic ring with the standard INFIX. 24 composite synthetic full pelvises were used in this study. 4 groups each with a number of six pelvic specimens were randomly assigned. A C1.3-type pelvic fracture was made with an osteotomy of the sacrum and an osteotomy of the anterior pelvic ring. Fracture fixation was performed within the four groups: (1) unilateral INFIX, (2) “extended” unilateral INFIX + additional pubic ramus pedicle screw, (3) bilateral INFIX, (4) “extended” bilateral INFIX + additional pubic ramus pedicle screw. All specimens were cyclic loaded with 200 N until maximum of 300 N. Distance/dislocation of the fracture fragments were detected with 3D-ultrasound measuring system. Stiffness was calculated. Extended unilateral INFIX showed the lowest mean dislocation. Lowest rotational stability was displayed by the standard bilateral INFIX. A significant difference (P = 0.04) was shown between the extended unilateral INFIX and the “standard” bilateral INFIX in terms of rotational stability. Extended unilateral INFIX showed significantly improved stability of anterior fracture dislocation (P = 0.01) and unilateral INFIX showed the highest rotational stiffness. Anterior fixation stiffness of the unilateral INFIX was significantly improved using an additional symphysis/pubic ramus screw (P = 0.002). Extended unilateral INFIX (+ additional pubic ramus pedicle screw) is a feasible minimally invasive treatment for anterior pelvic ring fractures. Higher stability and lower probability of bilateral nerve damage is provided by the extended unilateral INFIX compared to the standard bilateral INFIX.


  • Minimally invasive screw fixation is as stable as anterior plating in acetabular T-Type fractures – a biomechanical study

    by Christopher A. Becker, Christian Kammerlander, Adrian Cavalcanti Kußmaul, Fabian Dotzauer, Matthias Woiczinski, Bianka Rubenbauer, Fabian Sommer, Christoph Linhart, Simon Weidert, Christian Zeckey, et al.


  • CT-guided sacroiliac percutaneous screw placement in unstable posterior pelvic ring injuries: Accuracy of screw position, injury reduction and complications in 71 patients with 136 screws

    by Oliver Pieske, Christoph Landersdorfer, Christoph Trumm, Axel Greiner, Jens Wallmichrath, Oliver Gottschalk, Bianka Rubenbauer


  • Hydroxyapatite-Coated Pins Versus Titanium Alloy Pins in External Fixation at the Wrist: A Controlled Cohort Study

    by Oliver Pieske, Leopold Pichlmaier, Felicitas Kaltenhauser, Nicolai Schramm, Bianka Rubenbauer, Axel Greiner, Stefan Piltz

    The purpose of this study was to analyze whether the prevalence of pin-related complications can be reduced by the use of hydroxyapatite (HA)-coated pins in external fixators applied for unstable wrist fractures.Forty patients (160 pins) were randomized for standard uniplanar fixator treatment with the use of identically designed pins either composed of titanium-alloy (Ti6Al4V) (n = 20) or coated by HA (n = 20). Each pin site was clinically evaluated with regard to erythema, drainage, pain value, and radiologically assessed concerning loosening at T1 (mean, 9 days), T2 (mean, 43 days), and T3 (mean, 56 days). In case of pin-track complication, the patient was followed continuously. The need for antibiotics or additional surgery was documented. Bone mineral density was analyzed by Dual Energy X-ray Absorptiometry. At fixator removal (T2), the pin-extraction strength was measured by the use of a digital-torque-wrench.Two minor pin-track infections requiring oral antibiotics occurred in the HA-pin group (2.7%) (p > 0.05). The vast majority of clinical pin-site parameters were comparable in both groups. At the end of the fixator therapy, there were 16 loose pins (n(Ti6AL4V-group) = 10; n(HA-group) = 6). The rate of loose pins was correlated to patient's age (p < 0.05) but not to bone mineral density values or the occurrence of pin-site infection. Finally, no significant difference between the two groups was detected with regard to the prevalence of clinical relevant pin-site complications (p = 0.80).In external fixation of the wrist, the use of HA-coated pins yields no clinical advantages: there is a trend toward a superior pin-bone anchorage, but a tendency of increased susceptibility for minor pin-track infections.