Hydroxyapatite-Coated Pins Versus Titanium Alloy Pins in External Fixation at the Wrist: A Controlled Cohort Study
Authors:
- Oliver PieskeOPOliver Pieske
- Leopold PichlmaierLPLeopold Pichlmaier
- Felicitas KaltenhauserFKFelicitas Kaltenhauser
- Nicolai SchrammNSNicolai Schramm
- Bianka RubenbauerBRBianka Rubenbauer
- Axel GreinerAGAxel Greiner
- Stefan PiltzSPStefan Piltz
- 1 April 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 70 (4) , 845-851
Abstract
The purpose of this study was to analyze whether the prevalence of pin-related complications can be reduced by the use of hydroxyapatite (HA)-coated pins in external fixators applied for unstable wrist fractures.Forty patients (160 pins) were randomized for standard uniplanar fixator treatment with the use of identically designed pins either composed of titanium-alloy (Ti6Al4V) (n = 20) or coated by HA (n = 20). Each pin site was clinically evaluated with regard to erythema, drainage, pain value, and radiologically assessed concerning loosening at T1 (mean, 9 days), T2 (mean, 43 days), and T3 (mean, 56 days). In case of pin-track complication, the patient was followed continuously. The need for antibiotics or additional surgery was documented. Bone mineral density was analyzed by Dual Energy X-ray Absorptiometry. At fixator removal (T2), the pin-extraction strength was measured by the use of a digital-torque-wrench.Two minor pin-track infections requiring oral antibiotics occurred in the HA-pin group (2.7%) (p > 0.05). The vast majority of clinical pin-site parameters were comparable in both groups. At the end of the fixator therapy, there were 16 loose pins (n(Ti6AL4V-group) = 10; n(HA-group) = 6). The rate of loose pins was correlated to patient's age (p < 0.05) but not to bone mineral density values or the occurrence of pin-site infection. Finally, no significant difference between the two groups was detected with regard to the prevalence of clinical relevant pin-site complications (p = 0.80).In external fixation of the wrist, the use of HA-coated pins yields no clinical advantages: there is a trend toward a superior pin-bone anchorage, but a tendency of increased susceptibility for minor pin-track infections.Keywords
This publication has 20 references indexed in Scilit:
- The influence of hydroxyapatite coating of external fixator pins on pin loosening and pin track infection: A systematic reviewInjury, 2010
- Titanium Alloy Pins Versus Stainless Steel Pins in External Fixation at the Wrist: A Randomized Prospective StudyJournal of Trauma: Injury, Infection & Critical Care, 2008
- Fixation of HA-Coated Unicortical Locking Screws in a Sheep Gap Model: A Comparative Biomechanical StudyJournal of Orthopaedic Trauma, 2008
- The fixation strength of hydroxyapatite-coated Schanz screws and standard stainless steel Schanz screws in lower extremity lengtheningArchives of orthopaedic and trauma surgery, 2006
- A Meta-Analysis of Outcomes of External Fixation Versus Plate Osteosynthesis for Unstable Distal Radius FracturesThe Journal of Hand Surgery, 2005
- A contemporary snapshot of the use of hydroxyapatite coating in orthopaedic surgeryThe Journal of Bone and Joint Surgery. British volume, 2005
- Hydroxyapatite-coated external-fixation pinsThe Journal of Bone and Joint Surgery. British volume, 2004
- Effects of hydroxyapatite coating on Ti‐6 Al‐4V implant‐site infection in a rabbit tibial modelJournal of Orthopaedic Research, 2000
- The use of hydroxyapatite in orthopaedic surgery: A ten-year reviewEuropean Journal of Orthopaedic Surgery & Traumatology, 1999
- Thermal response and torque resistance of five cortical half‐pins under simulated insertion techniqueJournal of Orthopaedic Research, 1995