Geordi Pang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Geordi Pang has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Deabreu
Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
3 shared publications - Laura D'Alimonte
Department of Radiation Therapy, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
3 shared publications - Alexandre Mamedov
Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Canada
2 shared publications Colin I Tang
Calvary Mater Newcastle, Newcastle, Australia
2 shared publicationsD. Andrew Loblaw
Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, ON, Canada
2 shared publications- Gerard Morton
Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, ON, Canada; Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
2 shared publications
Latest Publications
- Open Access
- 18 October 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (20) , 12459
Assessing the DNA Damaging Effectiveness of Ionizing Radiation Using Plasmid DNA
Plasmid DNA is useful for investigating the DNA damaging effects of ionizing radiation. In this study, we have explored the feasibility of plasmid DNA-based detectors to assess the DNA damaging effectiveness of two radiotherapy X-ray beam qualities after undergoing return shipment of ~8000 km between two institutions. The detectors consisted of of pBR322 DNA enclosed with an aluminum seal in nine cylindrical cavities drilled into polycarbonate blocks. We shipped them to Toronto, Canada for irradiation with either or X-ray beams to doses of 10, 20, and 30 in triplicate before being shipped back to San Diego, USA. The Toronto return shipment also included non-irradiated controls and we kept a separate set of controls in San Diego. In San Diego, we quantified DNA single strand breaks (SSBs), double strand breaks (DSBs), and applied Nth and Fpg enzymes to quantify oxidized base damage. The rate of DSBs/Gy/plasmid was greater for the 100 kVp than the 6 MV irradiation. The irradiation also resulted in times more DSBs/SSB than the beam, demonstrating that the detector is sensitive enough to quantify relative DNA damage effectiveness, even after shipment over thousands of kilometers.- 18 October 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (20) , 12459
Open AccessAssessing the DNA Damaging Effectiveness of Ionizing Radiation Using Plasmid DNA
Plasmid DNA is useful for investigating the DNA damaging effects of ionizing radiation. In this study, we have explored the feasibility of plasmid DNA-based detectors to assess the DNA damaging effectiveness of two radiotherapy X-ray beam qualities after undergoing return shipment of ~8000 km between two institutions. The detectors consisted of of pBR322 DNA enclosed with an aluminum seal in nine cylindrical cavities drilled into polycarbonate blocks. We shipped them to Toronto, Canada for irradiation with either or X-ray beams to doses of 10, 20, and 30 in triplicate before being shipped back to San Diego, USA. The Toronto return shipment also included non-irradiated controls and we kept a separate set of controls in San Diego. In San Diego, we quantified DNA single strand breaks (SSBs), double strand breaks (DSBs), and applied Nth and Fpg enzymes to quantify oxidized base damage. The rate of DSBs/Gy/plasmid was greater for the 100 kVp than the 6 MV irradiation. The irradiation also resulted in times more DSBs/SSB than the beam, demonstrating that the detector is sensitive enough to quantify relative DNA damage effectiveness, even after shipment over thousands of kilometers. - Open Access
- 4 November 2019
- Published by Wiley in Medical Physics
- Vol. 47 (1) , 152-163
Development of a novel high quantum efficiency MV x‐ray detector for image‐guided radiotherapy: A feasibility study
Purpose To develop a new scintillating‐fiber‐based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. Methods Two prototypes were built: one with a single pixel readout and the other with an active matrix flat panel imager (AMFPI) for readout. The energy conversion layer of both prototypes was made of scintillating‐fiber layers interleaved with corrugated lead sheets to form a honeycomb pattern. The scintillating fibers have a diameter of 1 mm and the distance between the centers of neighboring fibers on the same layer is 1.35 mm. The layers have 1.22 mm spacing between them. The energy conversion layer has a thickness of 2 cm. The modulation transfer function (MTF), anti‐scatter properties and sensitivity of the detector with a single pixel readout were measured using 6 MV beam on a LINAC machine. In addition, a Monte Carlo simulation was conducted to calculate the zero‐frequency detective quantum efficiency (DQE(0)) of the proposed detector with an active matrix flat panel imager for readout. Results The DQE(0) of the proposed detector can be 11.5%, which is about an order of magnitude higher than that of current EPIDs. The frequency of 50% modulation (f50) of the measured MTF is 0.2 mm‐1 at 6 MV, which is comparable to that of video‐based EPIDs. The scatter to primary ratio (SPR) measured with the detector at 10 cm air gap and 20×20 cm2 field size is approximately 30% lower than that of ionization‐chamber‐based detectors with a comparable QE. The detector noise which includes the x‐ray quantum noise and absorption noise is much larger than the electronic noise per pixel of the flat‐panel imager at a dose of less than two LINAC pulses. Thus the proposed detector is quantum noise limited down to very low doses (~ a couple of radiation pulses of the LINAC). A proof‐of‐concept image has been obtained using a 6 MV beam. Conclusions This work indicates that by using scintillating fibers and lead layers it is possible to increase the thickness of the detecting materials, and therefore the QE or the DQE(0) of the detector, while maintaining an adequate spatial resolution for MV x‐ray imaging. Due to the use of lead as the spacing material, the new detector also has anti‐scatter property, which will help improve the signal‐to‐noise ratio of the images. Further investigation to optimize the design of the detector and achieve a better combination of DQE and spatial resolution is warranted.
- 4 November 2019
- Published by Wiley in Medical Physics
- Vol. 47 (1) , 152-163
Open AccessDevelopment of a novel high quantum efficiency MV x‐ray detector for image‐guided radiotherapy: A feasibility study
Purpose To develop a new scintillating‐fiber‐based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. Methods Two prototypes were built: one with a single pixel readout and the other with an active matrix flat panel imager (AMFPI) for readout. The energy conversion layer of both prototypes was made of scintillating‐fiber layers interleaved with corrugated lead sheets to form a honeycomb pattern. The scintillating fibers have a diameter of 1 mm and the distance between the centers of neighboring fibers on the same layer is 1.35 mm. The layers have 1.22 mm spacing between them. The energy conversion layer has a thickness of 2 cm. The modulation transfer function (MTF), anti‐scatter properties and sensitivity of the detector with a single pixel readout were measured using 6 MV beam on a LINAC machine. In addition, a Monte Carlo simulation was conducted to calculate the zero‐frequency detective quantum efficiency (DQE(0)) of the proposed detector with an active matrix flat panel imager for readout. Results The DQE(0) of the proposed detector can be 11.5%, which is about an order of magnitude higher than that of current EPIDs. The frequency of 50% modulation (f50) of the measured MTF is 0.2 mm‐1 at 6 MV, which is comparable to that of video‐based EPIDs. The scatter to primary ratio (SPR) measured with the detector at 10 cm air gap and 20×20 cm2 field size is approximately 30% lower than that of ionization‐chamber‐based detectors with a comparable QE. The detector noise which includes the x‐ray quantum noise and absorption noise is much larger than the electronic noise per pixel of the flat‐panel imager at a dose of less than two LINAC pulses. Thus the proposed detector is quantum noise limited down to very low doses (~ a couple of radiation pulses of the LINAC). A proof‐of‐concept image has been obtained using a 6 MV beam. Conclusions This work indicates that by using scintillating fibers and lead layers it is possible to increase the thickness of the detecting materials, and therefore the QE or the DQE(0) of the detector, while maintaining an adequate spatial resolution for MV x‐ray imaging. Due to the use of lead as the spacing material, the new detector also has anti‐scatter property, which will help improve the signal‐to‐noise ratio of the images. Further investigation to optimize the design of the detector and achieve a better combination of DQE and spatial resolution is warranted.
- Open Access
- 6 June 2017
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 18 (4) , 180-184
MR‐safe personal radiation dosimeters
Magnetic resonance imaging (MRI) is being rapidly integrated for cancer treatments—such systems are referred to as MRI-guided radiation therapy (MRIgRT). As the magnet of an MRI scanner is always on, the presence of a strong static magnetic field from the MRI scanner during radiotherapy delivery presents new challenges. One of the challenges is that a personal radiation dosimeter used to estimate the radiation dose deposited in an individual wearing the device must be MR-safe. No such devices, however, are currently available. In this work we first modified an existing personal dosimeter (by removing a metal clip) to make it MR-safe and then investigated potential effects of magnetic field on dosimeter readings, i.e., optically stimulated luminescent dosimeter (OSLD) readings. We found that the effect of magnetic field on OSLD sensitivity was within radiation protection tolerance levels. OSLD personal dosimeters can be directly used in conjunction with MRIgRT radiation protection purposes.
- 6 June 2017
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 18 (4) , 180-184
Open AccessMR‐safe personal radiation dosimeters
Magnetic resonance imaging (MRI) is being rapidly integrated for cancer treatments—such systems are referred to as MRI-guided radiation therapy (MRIgRT). As the magnet of an MRI scanner is always on, the presence of a strong static magnetic field from the MRI scanner during radiotherapy delivery presents new challenges. One of the challenges is that a personal radiation dosimeter used to estimate the radiation dose deposited in an individual wearing the device must be MR-safe. No such devices, however, are currently available. In this work we first modified an existing personal dosimeter (by removing a metal clip) to make it MR-safe and then investigated potential effects of magnetic field on dosimeter readings, i.e., optically stimulated luminescent dosimeter (OSLD) readings. We found that the effect of magnetic field on OSLD sensitivity was within radiation protection tolerance levels. OSLD personal dosimeters can be directly used in conjunction with MRIgRT radiation protection purposes.
- 1 March 2015
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 33 (7_suppl) , 224
Dose escalation of five-fraction SABR for prostate cancer: Biochemical outcome and toxicity comparison of two prospective trials.
224 Background: To compare the biochemical outcomes and toxicities of two different 5 fraction stereotactic ablative body radiotherapy (SABR) schedules for the treatment of localized prostate cancer. Methods: Two sequential phase I/II studies of 5-fraction SABR for the treatment of low and intermediate risk (LR and IR) prostate cancer have been conducted. In the first trial, 84 LR patients(pts) received 35 Gy in 5 fractions, once per week over 29 days (Group 1). In the second trial, 30 pts (18 LR, 11 IR) received 40 Gy in 5 fractions, once per week over 29 days (Group 2). Treatment was delivered to the prostate with intensity modulated radiotherapy using daily image guidance and a 4mm (Group 1) or 5 mm (Group 2) CTV-PTV margin. PSA nadir and bRFS(nadir+2 definition) were compared between the two groups. Acute (CTCv3.0), late (RTOG) and cumulative toxicity for late grade ≥ 2 GU/GI toxicities were also compared. Results: Median follow up was 74 (IQR 67-81) and 36 (IQR 32-39) months. Median PSA nadir was 0.4 ng/ml and 0.3 ng/ml. Time to PSA nadir was 54 and 32.5 months. 44.0% in group 1 and 30% in Group 2 experienced benign PSA bounce. There were 3 and 0 PSA failures in Groups 1 and 2. 2-, 4- and 6-year bRFS was 100%, 98.7% and 95.9% and 100%, 100% and not reached in groups 1 and 2, respectively (p=0.91). The only acute grade 3 toxicity was noticed in Group 1 (1 pt, GU). Late grade 4 GI toxicity was noted in Group 1 (1 pt, GI, fistula). Up to 4 years of follow-up, Group 2 pts have had a greater percentage of grade 2+ cumulative GU (5.0% vs 24.2%) and GI (7.6% vs 26.2%) toxicities. Conclusions: Pts receiving a dose escalated SABR had slightly lower PSA nadir and similar bRFS - longer follow up is needed to better estimate biochemical outcomes in Group 2. There seemed to be a greater risk of grade 2 toxicities in the higher dose cohort but grade 3+ toxicities were not increased. Quality of life analyses will be presented separately. Clinical trial information: NCT01578902 , NCT01146340 .[Table: see text]
- 1 March 2015
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 33 (7_suppl) , 224
Dose escalation of five-fraction SABR for prostate cancer: Biochemical outcome and toxicity comparison of two prospective trials.
224 Background: To compare the biochemical outcomes and toxicities of two different 5 fraction stereotactic ablative body radiotherapy (SABR) schedules for the treatment of localized prostate cancer. Methods: Two sequential phase I/II studies of 5-fraction SABR for the treatment of low and intermediate risk (LR and IR) prostate cancer have been conducted. In the first trial, 84 LR patients(pts) received 35 Gy in 5 fractions, once per week over 29 days (Group 1). In the second trial, 30 pts (18 LR, 11 IR) received 40 Gy in 5 fractions, once per week over 29 days (Group 2). Treatment was delivered to the prostate with intensity modulated radiotherapy using daily image guidance and a 4mm (Group 1) or 5 mm (Group 2) CTV-PTV margin. PSA nadir and bRFS(nadir+2 definition) were compared between the two groups. Acute (CTCv3.0), late (RTOG) and cumulative toxicity for late grade ≥ 2 GU/GI toxicities were also compared. Results: Median follow up was 74 (IQR 67-81) and 36 (IQR 32-39) months. Median PSA nadir was 0.4 ng/ml and 0.3 ng/ml. Time to PSA nadir was 54 and 32.5 months. 44.0% in group 1 and 30% in Group 2 experienced benign PSA bounce. There were 3 and 0 PSA failures in Groups 1 and 2. 2-, 4- and 6-year bRFS was 100%, 98.7% and 95.9% and 100%, 100% and not reached in groups 1 and 2, respectively (p=0.91). The only acute grade 3 toxicity was noticed in Group 1 (1 pt, GU). Late grade 4 GI toxicity was noted in Group 1 (1 pt, GI, fistula). Up to 4 years of follow-up, Group 2 pts have had a greater percentage of grade 2+ cumulative GU (5.0% vs 24.2%) and GI (7.6% vs 26.2%) toxicities. Conclusions: Pts receiving a dose escalated SABR had slightly lower PSA nadir and similar bRFS - longer follow up is needed to better estimate biochemical outcomes in Group 2. There seemed to be a greater risk of grade 2 toxicities in the higher dose cohort but grade 3+ toxicities were not increased. Quality of life analyses will be presented separately. Clinical trial information: NCT01578902 , NCT01146340 .[Table: see text]
- Open Access
- 28 November 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 262
Prostatic displacement during extreme hypofractionated radiotherapy using volumetric modulated arc therapy (VMAT)
To determine prostate displacement during extreme hypofractionated volume modulated arc radiotherapy (VMAT) using pre- and post-treatment orthogonal images with three implanted gold seed fiducial markers. A total of 150 image pairs were obtained from 30 patients who underwent extreme hypofractionated radiotherapy to a dose of 40 Gy in five fractions on standard linear accelerators. Position verification was obtained with orthogonal x-rays before and after treatment and were used to determine intra-fraction prostate displacement. The mean prostate displacements were 0.03 ± 1.23 mm (1SD), 0.18 ± 1.55 mm, and 0.37 ± 1.95 mm in the left-right, superior-inferior, and anterior-posterior directions, respectively. The mean 3D displacement was 2.32 ± 1.55 mm. Only 6 (4%) fractions had a 3D displacement of >5 mm. The average time of treatment delivery for a given fraction was 195 ± 59 seconds. The mean intra-fraction prostate displacement during a course of extreme hypofractionated radiotherapy delivered via VMAT, continues to be small. Clinical margins typically used in a similar fixed-angle IMRT treatment are adequate. The use of VMAT in further extreme hypofractionation may limit prostatic motion uncertainties that would be otherwise be associated with longer treatment times.
- 28 November 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 262
Open AccessProstatic displacement during extreme hypofractionated radiotherapy using volumetric modulated arc therapy (VMAT)
To determine prostate displacement during extreme hypofractionated volume modulated arc radiotherapy (VMAT) using pre- and post-treatment orthogonal images with three implanted gold seed fiducial markers. A total of 150 image pairs were obtained from 30 patients who underwent extreme hypofractionated radiotherapy to a dose of 40 Gy in five fractions on standard linear accelerators. Position verification was obtained with orthogonal x-rays before and after treatment and were used to determine intra-fraction prostate displacement. The mean prostate displacements were 0.03 ± 1.23 mm (1SD), 0.18 ± 1.55 mm, and 0.37 ± 1.95 mm in the left-right, superior-inferior, and anterior-posterior directions, respectively. The mean 3D displacement was 2.32 ± 1.55 mm. Only 6 (4%) fractions had a 3D displacement of >5 mm. The average time of treatment delivery for a given fraction was 195 ± 59 seconds. The mean intra-fraction prostate displacement during a course of extreme hypofractionated radiotherapy delivered via VMAT, continues to be small. Clinical margins typically used in a similar fixed-angle IMRT treatment are adequate. The use of VMAT in further extreme hypofractionation may limit prostatic motion uncertainties that would be otherwise be associated with longer treatment times.
- 30 June 2012
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 81 (6) , 599-608
Characteristics of radiation induced light in optical fibres for portal imaging application
- 30 June 2012
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 81 (6) , 599-608
Characteristics of radiation induced light in optical fibres for portal imaging application
- 10 February 2012
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 30 (5) , 186
Biochemical, pathologic, toxicity, and quality-of-life outcomes in a five-fraction hypofractionated accelerated radiotherapy treatment using standard linear accelerators and gold seed fiducials.
186 Background: Biological dose escalation through hypofractionated image-guided radiotherapy (H-IGRT) holds the promise of improved patient outcomes, system capacity but decreased cost. In 2006 we initiated a prospective trial of H-IGRT of patients with low risk localized prostate cancer. In this report, we report the toxicities, quality of life (QOL), biochemical and pathologic outcomes of this cohort with more mature follow-up. Methods: A phase I/II study in which patients with T1-2b, Gleason≤6, and PSA≤10 ng/ml prostate cancer received 35 Gy in 5 fractions, once a week over 29 days. No patients received hormone therapy. Treatment was delivered with intensity modulated radiotherapy (IMRT) on standard linear accelerators, with daily image guidance using gold seed fiducials, and a 4 mm CTV-PTV margin. CTCAE v3.0 and RTOG late morbidity scores were used to assess acute and late toxicities, respectively. QOL was assessed by the Expanded Prostate Cancer Index Composite (EPIC). Biochemical control (BC) was defined by the Phoenix definition, adjusted for benign bounce. Results: As of September 2011, 83 patients have completed treatment with a median follow-up of 42 months (range 12–60 months). Median age was 67y (42 – 82y). 78 patients (92%) were T1a-c; all had Gleason 6 cancers; median PSA was 5.3 (0.8 – 9.9 ng/ml). 82 (99%) had BC; the remaining patient had a negative biopsy and a history of chronic prostatitis. The median PSA on last visit was 0.69 ng/ml (.02 – 2.6 ng/ml). Of 59 patients who have had a biopsy to date, 2 (3%) were positive but both are under BC. The following toxicities were observed: acute grade 3+: 0% GI, 1% GU, 0% fatigue; late grade 3+: 1% GI, 1% GU. Median transformed QOL scores at baseline (0.5 SD) and 36mo follow-up are: urinary – 95% (4.1), 93%; bowel – 96% (4.8), 96%; sexual – 65% (13.7), 51%; and hormonal – 95% (5.3), 95%. Conclusions: This novel technique employing standard linear accelerators to deliver an extreme hypofractionated schedule of radiotherapy is feasible, well tolerated and shows excellent pathologic and biochemical control. A randomized study versus standard fractionation should be performed.
- 10 February 2012
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 30 (5) , 186
Biochemical, pathologic, toxicity, and quality-of-life outcomes in a five-fraction hypofractionated accelerated radiotherapy treatment using standard linear accelerators and gold seed fiducials.
186 Background: Biological dose escalation through hypofractionated image-guided radiotherapy (H-IGRT) holds the promise of improved patient outcomes, system capacity but decreased cost. In 2006 we initiated a prospective trial of H-IGRT of patients with low risk localized prostate cancer. In this report, we report the toxicities, quality of life (QOL), biochemical and pathologic outcomes of this cohort with more mature follow-up. Methods: A phase I/II study in which patients with T1-2b, Gleason≤6, and PSA≤10 ng/ml prostate cancer received 35 Gy in 5 fractions, once a week over 29 days. No patients received hormone therapy. Treatment was delivered with intensity modulated radiotherapy (IMRT) on standard linear accelerators, with daily image guidance using gold seed fiducials, and a 4 mm CTV-PTV margin. CTCAE v3.0 and RTOG late morbidity scores were used to assess acute and late toxicities, respectively. QOL was assessed by the Expanded Prostate Cancer Index Composite (EPIC). Biochemical control (BC) was defined by the Phoenix definition, adjusted for benign bounce. Results: As of September 2011, 83 patients have completed treatment with a median follow-up of 42 months (range 12–60 months). Median age was 67y (42 – 82y). 78 patients (92%) were T1a-c; all had Gleason 6 cancers; median PSA was 5.3 (0.8 – 9.9 ng/ml). 82 (99%) had BC; the remaining patient had a negative biopsy and a history of chronic prostatitis. The median PSA on last visit was 0.69 ng/ml (.02 – 2.6 ng/ml). Of 59 patients who have had a biopsy to date, 2 (3%) were positive but both are under BC. The following toxicities were observed: acute grade 3+: 0% GI, 1% GU, 0% fatigue; late grade 3+: 1% GI, 1% GU. Median transformed QOL scores at baseline (0.5 SD) and 36mo follow-up are: urinary – 95% (4.1), 93%; bowel – 96% (4.8), 96%; sexual – 65% (13.7), 51%; and hormonal – 95% (5.3), 95%. Conclusions: This novel technique employing standard linear accelerators to deliver an extreme hypofractionated schedule of radiotherapy is feasible, well tolerated and shows excellent pathologic and biochemical control. A randomized study versus standard fractionation should be performed.
- 24 January 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (4) , 999-1013
Megavoltage cone beam digital tomosynthesis (MV-CBDT) for image-guided radiotherapy: a clinical investigational system
Cone beam digital tomosynthesis (CBDT) is a new imaging technique proposed recently as a rapid approach for creating tomographic images of a patient in the radiotherapy treatment room. The purpose of this work is to investigate the feasibility of performing megavoltage (MV) CBDT clinically. A clinical investigational MV-CBDT system was installed on an existing LINAC. After the installation, the treatment machine can be operated in two distinct modes: (1) normal clinical treatment mode; (2) CBDT mode, in which tomographic images of the patient can be obtained using MV-CBDT. Various calibration and phantom measurements were performed on the system, followed by a patient study. Our phantom measurements have shown that: (1) for the same imaging dose, MV-CBDT has the same signal-difference-to-noise ratio as megavoltage cone beam computed tomography (MV-CBCT); (2) MV-CBDT has a better spatial resolution than MV-CBCT in the planes of reconstruction but a worse spatial resolution in the direction perpendicular to the planes of reconstruction. MV-CBDT patient images were also obtained and compared to that of MV-CBCT. We have demonstrated that it is clinically feasible to perform MV-CBDT in the treatment room for image-guided radiotherapy.
- 24 January 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (4) , 999-1013
Megavoltage cone beam digital tomosynthesis (MV-CBDT) for image-guided radiotherapy: a clinical investigational system
Cone beam digital tomosynthesis (CBDT) is a new imaging technique proposed recently as a rapid approach for creating tomographic images of a patient in the radiotherapy treatment room. The purpose of this work is to investigate the feasibility of performing megavoltage (MV) CBDT clinically. A clinical investigational MV-CBDT system was installed on an existing LINAC. After the installation, the treatment machine can be operated in two distinct modes: (1) normal clinical treatment mode; (2) CBDT mode, in which tomographic images of the patient can be obtained using MV-CBDT. Various calibration and phantom measurements were performed on the system, followed by a patient study. Our phantom measurements have shown that: (1) for the same imaging dose, MV-CBDT has the same signal-difference-to-noise ratio as megavoltage cone beam computed tomography (MV-CBCT); (2) MV-CBDT has a better spatial resolution than MV-CBCT in the planes of reconstruction but a worse spatial resolution in the direction perpendicular to the planes of reconstruction. MV-CBDT patient images were also obtained and compared to that of MV-CBCT. We have demonstrated that it is clinically feasible to perform MV-CBDT in the treatment room for image-guided radiotherapy.
- Open Access
- 1 June 2007
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 8 (3) , 137-146
Lag correction model and ghosting analysis for an indirect‐conversion flat‐panel imager
Cone‐beam digital tomosynthesis (CBDT) is a new approach that was recently proposed for rapid tomographic imaging of soft‐tissue targets in the radiotherapy treatment room. One of the potential problems in implementing CBDT using, for example, megavoltage (MV) X rays is the possibility of artifacts caused by image lag and ghosting of the X‐ray detector used. In the present work, we developed a model to correct for image lag with indirect‐conversion flat‐panel imagers (FPIs) used for MV‐CBDT. This model is based on measurement and analysis of image lag in an indirect‐conversion FPI irradiated with a 6‐MV X‐ray beam. Our results demonstrated that image lag is amenable to correction. In addition, we measured the ghosting effect for an indirect‐conversion FPI and found it to be insignificant.PACS numbers: 87.53.Oq, 87.57.Ce
- 1 June 2007
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 8 (3) , 137-146
Open AccessLag correction model and ghosting analysis for an indirect‐conversion flat‐panel imager
Cone‐beam digital tomosynthesis (CBDT) is a new approach that was recently proposed for rapid tomographic imaging of soft‐tissue targets in the radiotherapy treatment room. One of the potential problems in implementing CBDT using, for example, megavoltage (MV) X rays is the possibility of artifacts caused by image lag and ghosting of the X‐ray detector used. In the present work, we developed a model to correct for image lag with indirect‐conversion flat‐panel imagers (FPIs) used for MV‐CBDT. This model is based on measurement and analysis of image lag in an indirect‐conversion FPI irradiated with a 6‐MV X‐ray beam. Our results demonstrated that image lag is amenable to correction. In addition, we measured the ghosting effect for an indirect‐conversion FPI and found it to be insignificant.PACS numbers: 87.53.Oq, 87.57.Ce