Prashanth Nookala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Prashanth Nookala has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Baldev Patyal
Loma Linda University, Loma Linda, CA
4 shared publications - Jerry Monroe Slater
Loma Linda University, Loma Linda, CA
3 shared publications - Rachel Mifflin
Loma Linda University, Loma Linda, CA
3 shared publications - Roger Grove
Loma Linda University, Loma Linda, CA
3 shared publications Anh Ly
Loma Linda University, Loma Linda, CA
2 shared publications- Gary Y. Yang
Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, California, USA
2 shared publications
Latest Publications
- Open Access
- 24 October 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 1-11
Passive proton therapy vs. IMRT planning study with focal boost for prostate cancer
Exploiting biologic imaging, studies have been performed to boost dose to gross intraprostatic tumor volumes (GTV) while reducing dose elsewhere in the prostate. Interest in proton beams has increased due to superior normal-tissue sparing they afford. Our goal was to dosimetrically compare 3D conformal proton boost plans with intensity-modulated radiation therapy (IMRT) plans with respect to target coverage and avoiding organs at risk. Treatment planning computer tomography scans of ten patients were selected. For each patient, two hypothetical but realistic GTVs each with a fixed volume were contoured in different anatomical locations of the prostate. IMRT and proton beam plans were created with a prescribed dose of 50.4 Gy to the initial planning target volume (PTV) including the PTV of the seminal vesicles (PSV), 70.2 Gy to the PTV of the prostate (PPS), and 90 Gy to the PTV of the gross tumor volumes (PGTVs). For proton plans, uncertainties of range and patient setup were accounted for; apertures were adjusted until the dose-volume coverage of PTVs matched that of the IMRT plan. For both plans, prescribed PTV doses were made identical to allow for comparing normal-tissue doses. Protons delivered more homogeneous but less conformal doses to PGTVs than IMRT did and comparable doses to PSV and PPS. Volumes of bladder and rectum receiving doses higher than 65 Gy were similar for both plans. However, volumes receiving less than 65 Gy were significantly reduced, i.e., protons reduced integral dose by 45.6 % and 26.5 % for rectum and bladder, respectively. This volume-sparing was also seen in femoral heads and penile bulb. Protons delivered comparable doses to targets in dose homogeneity and conformity and spared normal tissues from intermediate-to-low doses better than IMRT did. Further improvement of dose sparing and changes in homogeneity and conformity may be achieved by reducing proton range uncertainties and from implementing intensity modulation.
- 24 October 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 1-11
Open AccessPassive proton therapy vs. IMRT planning study with focal boost for prostate cancer
Exploiting biologic imaging, studies have been performed to boost dose to gross intraprostatic tumor volumes (GTV) while reducing dose elsewhere in the prostate. Interest in proton beams has increased due to superior normal-tissue sparing they afford. Our goal was to dosimetrically compare 3D conformal proton boost plans with intensity-modulated radiation therapy (IMRT) plans with respect to target coverage and avoiding organs at risk. Treatment planning computer tomography scans of ten patients were selected. For each patient, two hypothetical but realistic GTVs each with a fixed volume were contoured in different anatomical locations of the prostate. IMRT and proton beam plans were created with a prescribed dose of 50.4 Gy to the initial planning target volume (PTV) including the PTV of the seminal vesicles (PSV), 70.2 Gy to the PTV of the prostate (PPS), and 90 Gy to the PTV of the gross tumor volumes (PGTVs). For proton plans, uncertainties of range and patient setup were accounted for; apertures were adjusted until the dose-volume coverage of PTVs matched that of the IMRT plan. For both plans, prescribed PTV doses were made identical to allow for comparing normal-tissue doses. Protons delivered more homogeneous but less conformal doses to PGTVs than IMRT did and comparable doses to PSV and PPS. Volumes of bladder and rectum receiving doses higher than 65 Gy were similar for both plans. However, volumes receiving less than 65 Gy were significantly reduced, i.e., protons reduced integral dose by 45.6 % and 26.5 % for rectum and bladder, respectively. This volume-sparing was also seen in femoral heads and penile bulb. Protons delivered comparable doses to targets in dose homogeneity and conformity and spared normal tissues from intermediate-to-low doses better than IMRT did. Further improvement of dose sparing and changes in homogeneity and conformity may be achieved by reducing proton range uncertainties and from implementing intensity modulation.
- Open Access
Analysis of Intensity-Modulated Radiation Therapy (IMRT), Proton and 3D Conformal Radiotherapy (3D-CRT) for Reducing Perioperative Cardiopulmonary Complications in Esophageal Cancer Patients
Background. While neoadjuvant concurrent chemoradiotherapy has improved outcomes for esophageal cancer patients, surgical complication rates remain high. The most frequent perioperative complications after trimodality therapy were cardiopulmonary in nature. The radiation modality utilized can be a strong mitigating factor of perioperative complications given the location of the esophagus and its proximity to the heart and lungs. The purpose of this study is to make a dosimetric comparison of Intensity-Modulated Radiation Therapy (IMRT), proton and 3D conformal radiotherapy (3D-CRT) with regard to reducing perioperative cardiopulmonary complications in esophageal cancer patients. Materials. Ten patients with esophageal cancer treated between 2010 and 2013 were evaluated in this study. All patients were simulated with contrast-enhanced CT imaging. Separate treatment plans using proton radiotherapy, IMRT, and 3D-CRT modalities were created for each patient. Dose-volume histograms were calculated and analyzed to compare plans between the three modalities. The organs at risk (OAR) being evaluated in this study are the heart, lungs, and spinal cord. To determine statistical significance, ANOVA and two-tailed paired t-tests were performed for all data parameters. Results. The proton plans showed decreased dose to various volumes of the heart and lungs in comparison to both the IMRT and 3D-CRT plans. There was no difference between the IMRT and 3D-CRT plans in dose delivered to the lung or heart. This finding was seen consistently across the parameters analyzed in this study. Conclusions. In patients receiving radiation therapy for esophageal cancer, proton plans are technically feasible while achieving adequate coverage with lower doses delivered to the lungs and cardiac structures. This may result in decreased cardiopulmonary toxicity and less morbidity to esophageal cancer patients.
Open AccessAnalysis of Intensity-Modulated Radiation Therapy (IMRT), Proton and 3D Conformal Radiotherapy (3D-CRT) for Reducing Perioperative Cardiopulmonary Complications in Esophageal Cancer Patients
Background. While neoadjuvant concurrent chemoradiotherapy has improved outcomes for esophageal cancer patients, surgical complication rates remain high. The most frequent perioperative complications after trimodality therapy were cardiopulmonary in nature. The radiation modality utilized can be a strong mitigating factor of perioperative complications given the location of the esophagus and its proximity to the heart and lungs. The purpose of this study is to make a dosimetric comparison of Intensity-Modulated Radiation Therapy (IMRT), proton and 3D conformal radiotherapy (3D-CRT) with regard to reducing perioperative cardiopulmonary complications in esophageal cancer patients. Materials. Ten patients with esophageal cancer treated between 2010 and 2013 were evaluated in this study. All patients were simulated with contrast-enhanced CT imaging. Separate treatment plans using proton radiotherapy, IMRT, and 3D-CRT modalities were created for each patient. Dose-volume histograms were calculated and analyzed to compare plans between the three modalities. The organs at risk (OAR) being evaluated in this study are the heart, lungs, and spinal cord. To determine statistical significance, ANOVA and two-tailed paired t-tests were performed for all data parameters. Results. The proton plans showed decreased dose to various volumes of the heart and lungs in comparison to both the IMRT and 3D-CRT plans. There was no difference between the IMRT and 3D-CRT plans in dose delivered to the lung or heart. This finding was seen consistently across the parameters analyzed in this study. Conclusions. In patients receiving radiation therapy for esophageal cancer, proton plans are technically feasible while achieving adequate coverage with lower doses delivered to the lungs and cardiac structures. This may result in decreased cardiopulmonary toxicity and less morbidity to esophageal cancer patients.
- 20 January 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (3_suppl) , 369
A treatment planning evaluation of protons versus IMRT in pancreatic cancer: A comparative study.
369 Background: The purpose of this study is to investigate dose distributions of proton and intensity-modulated radiation therapy (IMRT) photon treatment plans in patients with resected pancreatic adenocarcinoma, focusing specifically on dose reduction to the kidney, liver, and small bowel as organs at risk. Methods: Ten patients with pancreatic head adenocarcinoma underwent Whipple procedure between 2010 and 2013 were included in this study. Most of the patients had locally advanced disease (T3-4N1). All patients were simulated with contrast-enhanced CT imaging. The clinical target volume (CTV) consisted of the pre-operative extent of tumor plus a 10 mm manual expansion in all directions. The planning target volume (PTV) was generated by a further expansion on the CTV ranging from 10-15 mm. A dose of 50.4 Gy given in 28 fractions was delivered to the PTV. All plans were optimized to allow 95% isodose coverage of at least 95% of the PTV. Dose-volume histograms, conformity index (CI), uniformity index (UI), homogeneity index (HI), were calculated and analyzed in order to compare plans between the two modalities. The OAR being evaluated in this study are the kidneys, liver, small bowel, and spinal cord. To determine statistical significance, ANOVA and two-tailed paired t-tests were performed for all data parameters. Results: The proton plans resulted in a lower mean kidney dose (3.17 Gy vs. 9.59 Gy, p=0.039), a lower dose delivered to 1/3 of the liver, D1/3, (0.25 Gy vs. 4.56 Gy, p=0.003), and a lower mean liver dose (1.83 Gy vs. 5.24 Gy, p=0.021). See table for a summary of the results. Conclusions: For patients receiving postoperative radiotherapy for pancreatic cancer, the proton plans are technically feasible and dosimetrically appealing with superior organ at risk sparing compared to IMRT photon treatment plans.[Table: see text]
- 20 January 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (3_suppl) , 369
A treatment planning evaluation of protons versus IMRT in pancreatic cancer: A comparative study.
369 Background: The purpose of this study is to investigate dose distributions of proton and intensity-modulated radiation therapy (IMRT) photon treatment plans in patients with resected pancreatic adenocarcinoma, focusing specifically on dose reduction to the kidney, liver, and small bowel as organs at risk. Methods: Ten patients with pancreatic head adenocarcinoma underwent Whipple procedure between 2010 and 2013 were included in this study. Most of the patients had locally advanced disease (T3-4N1). All patients were simulated with contrast-enhanced CT imaging. The clinical target volume (CTV) consisted of the pre-operative extent of tumor plus a 10 mm manual expansion in all directions. The planning target volume (PTV) was generated by a further expansion on the CTV ranging from 10-15 mm. A dose of 50.4 Gy given in 28 fractions was delivered to the PTV. All plans were optimized to allow 95% isodose coverage of at least 95% of the PTV. Dose-volume histograms, conformity index (CI), uniformity index (UI), homogeneity index (HI), were calculated and analyzed in order to compare plans between the two modalities. The OAR being evaluated in this study are the kidneys, liver, small bowel, and spinal cord. To determine statistical significance, ANOVA and two-tailed paired t-tests were performed for all data parameters. Results: The proton plans resulted in a lower mean kidney dose (3.17 Gy vs. 9.59 Gy, p=0.039), a lower dose delivered to 1/3 of the liver, D1/3, (0.25 Gy vs. 4.56 Gy, p=0.003), and a lower mean liver dose (1.83 Gy vs. 5.24 Gy, p=0.021). See table for a summary of the results. Conclusions: For patients receiving postoperative radiotherapy for pancreatic cancer, the proton plans are technically feasible and dosimetrically appealing with superior organ at risk sparing compared to IMRT photon treatment plans.[Table: see text]
- 20 January 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (3) , 167
A comparison of proton and photon radiotherapy in reducing cardiac exposure for patients receiving radiation therapy for distal and esophagogastric junction cancer.
167 Background: Recent studies indicate that radiation exposure to heart may have a greater impact on perioperative cardiac morbidities than do other clinical factors. The purpose of this study is to investigate dose distributions of proton and photon treatment plans in patients (pts) with distal and esophagogastric junction (GEJ) carcinoma, focusing specifically on dose reduction to cardiac structures. Methods: Ten pts between 2010 and 2013 were included in this study. Three separate plans were generated for each patient: 3D proton plan, 3D photon plan, and Intensity modulated radiotherapy (IMRT) photon plan. The clinical target volume (CTV) consisted of the pre-operative extent of tumor plus a 10mm manual expansion in all directions. The planning target volume (PTV) was generated by a further expansion on the CTV ranging from 10-15mm. A dose of 50.4Gy given in 28 fractions was delivered to the PTV. All plans were optimized to allow 90% isodose coverage of at least 95% of the PTV. Dose-volume histograms were calculated and analyzed in order to compare plans between the three modalities. ANOVA and two-tailed paired t-tests were performed for all data parameters. Results: The 3D proton plans showed decreased dose to partial volumes of the entire heart, arteries, valves, atria, and ventricles in comparison to both the IMRT and 3D photon plans (see Table). The IMRT plans showed decreased dose delivered to the LAD artery, pericardium, and atria in comparison to the 3D photon plans (see Table). Conclusions: For pts receiving radiation therapy for distal esophageal and GEJ cancer, proton plans are technically feasible with adequate coverage while resulting in lower dose to cardiac structures. This may result in decreased cardiac toxicity and less complications in a multimodality setting. [Table: see text]
- 20 January 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (3) , 167
A comparison of proton and photon radiotherapy in reducing cardiac exposure for patients receiving radiation therapy for distal and esophagogastric junction cancer.
167 Background: Recent studies indicate that radiation exposure to heart may have a greater impact on perioperative cardiac morbidities than do other clinical factors. The purpose of this study is to investigate dose distributions of proton and photon treatment plans in patients (pts) with distal and esophagogastric junction (GEJ) carcinoma, focusing specifically on dose reduction to cardiac structures. Methods: Ten pts between 2010 and 2013 were included in this study. Three separate plans were generated for each patient: 3D proton plan, 3D photon plan, and Intensity modulated radiotherapy (IMRT) photon plan. The clinical target volume (CTV) consisted of the pre-operative extent of tumor plus a 10mm manual expansion in all directions. The planning target volume (PTV) was generated by a further expansion on the CTV ranging from 10-15mm. A dose of 50.4Gy given in 28 fractions was delivered to the PTV. All plans were optimized to allow 90% isodose coverage of at least 95% of the PTV. Dose-volume histograms were calculated and analyzed in order to compare plans between the three modalities. ANOVA and two-tailed paired t-tests were performed for all data parameters. Results: The 3D proton plans showed decreased dose to partial volumes of the entire heart, arteries, valves, atria, and ventricles in comparison to both the IMRT and 3D photon plans (see Table). The IMRT plans showed decreased dose delivered to the LAD artery, pericardium, and atria in comparison to the 3D photon plans (see Table). Conclusions: For pts receiving radiation therapy for distal esophageal and GEJ cancer, proton plans are technically feasible with adequate coverage while resulting in lower dose to cardiac structures. This may result in decreased cardiac toxicity and less complications in a multimodality setting. [Table: see text]