Jerry Monroe Slater
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jerry Monroe Slater has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Baldev Patyal
Loma Linda University, Loma Linda, CA
3 shared publications - Prashanth Nookala
Loma Linda University, Loma Linda, CA
3 shared publications Anh Ly
Loma Linda University, Loma Linda, CA
2 shared publicationsGary Yang
Loma Linda University Medical Center, Loma Linda, CA
2 shared publications- Rachel Mifflin
Loma Linda University, Loma Linda, CA
2 shared publications - Reinhard Schulte
Department of Basic Sciences, Loma Linda University School of Medicine, 11085 Campus Street, Loma Linda, California, 92350, UNITED STATES
2 shared publications
Latest Publications
- Open Access
- 17 September 2021
- Published by Wiley in Precision Radiation Oncology
- Vol. 5 (3) , 202-204
Multiple severe late adverse effects after definitive chemoradiation for locally advanced cervical cancer
Concurrent chemoradiation is the standard of care for locally advanced cervical cancer and is commonly associated with mild to moderate toxicities. Severe late complications in multiple organ systems in patients without known patient‐ or treatment‐related risk factors are rare. A 42‐year‐old woman was treated with definitive chemoradiotherapy with external beam radiotherapy and brachytherapy. She had complete resolution of the disease, with no evidence of recurrence. However, she experienced late morbidity in multiple organ systems due to treatment, likely indicating an increased sensitivity to radiation. This case highlights the need for improvements in the identification of such patients.
- 17 September 2021
- Published by Wiley in Precision Radiation Oncology
- Vol. 5 (3) , 202-204
Open AccessMultiple severe late adverse effects after definitive chemoradiation for locally advanced cervical cancer
Concurrent chemoradiation is the standard of care for locally advanced cervical cancer and is commonly associated with mild to moderate toxicities. Severe late complications in multiple organ systems in patients without known patient‐ or treatment‐related risk factors are rare. A 42‐year‐old woman was treated with definitive chemoradiotherapy with external beam radiotherapy and brachytherapy. She had complete resolution of the disease, with no evidence of recurrence. However, she experienced late morbidity in multiple organ systems due to treatment, likely indicating an increased sensitivity to radiation. This case highlights the need for improvements in the identification of such patients.
- Open Access
- 24 October 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 1-11
Passive proton therapy vs. IMRT planning study with focal boost for prostate cancer
Exploiting biologic imaging, studies have been performed to boost dose to gross intraprostatic tumor volumes (GTV) while reducing dose elsewhere in the prostate. Interest in proton beams has increased due to superior normal-tissue sparing they afford. Our goal was to dosimetrically compare 3D conformal proton boost plans with intensity-modulated radiation therapy (IMRT) plans with respect to target coverage and avoiding organs at risk. Treatment planning computer tomography scans of ten patients were selected. For each patient, two hypothetical but realistic GTVs each with a fixed volume were contoured in different anatomical locations of the prostate. IMRT and proton beam plans were created with a prescribed dose of 50.4 Gy to the initial planning target volume (PTV) including the PTV of the seminal vesicles (PSV), 70.2 Gy to the PTV of the prostate (PPS), and 90 Gy to the PTV of the gross tumor volumes (PGTVs). For proton plans, uncertainties of range and patient setup were accounted for; apertures were adjusted until the dose-volume coverage of PTVs matched that of the IMRT plan. For both plans, prescribed PTV doses were made identical to allow for comparing normal-tissue doses. Protons delivered more homogeneous but less conformal doses to PGTVs than IMRT did and comparable doses to PSV and PPS. Volumes of bladder and rectum receiving doses higher than 65 Gy were similar for both plans. However, volumes receiving less than 65 Gy were significantly reduced, i.e., protons reduced integral dose by 45.6 % and 26.5 % for rectum and bladder, respectively. This volume-sparing was also seen in femoral heads and penile bulb. Protons delivered comparable doses to targets in dose homogeneity and conformity and spared normal tissues from intermediate-to-low doses better than IMRT did. Further improvement of dose sparing and changes in homogeneity and conformity may be achieved by reducing proton range uncertainties and from implementing intensity modulation.
- 24 October 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 1-11
Open AccessPassive proton therapy vs. IMRT planning study with focal boost for prostate cancer
Exploiting biologic imaging, studies have been performed to boost dose to gross intraprostatic tumor volumes (GTV) while reducing dose elsewhere in the prostate. Interest in proton beams has increased due to superior normal-tissue sparing they afford. Our goal was to dosimetrically compare 3D conformal proton boost plans with intensity-modulated radiation therapy (IMRT) plans with respect to target coverage and avoiding organs at risk. Treatment planning computer tomography scans of ten patients were selected. For each patient, two hypothetical but realistic GTVs each with a fixed volume were contoured in different anatomical locations of the prostate. IMRT and proton beam plans were created with a prescribed dose of 50.4 Gy to the initial planning target volume (PTV) including the PTV of the seminal vesicles (PSV), 70.2 Gy to the PTV of the prostate (PPS), and 90 Gy to the PTV of the gross tumor volumes (PGTVs). For proton plans, uncertainties of range and patient setup were accounted for; apertures were adjusted until the dose-volume coverage of PTVs matched that of the IMRT plan. For both plans, prescribed PTV doses were made identical to allow for comparing normal-tissue doses. Protons delivered more homogeneous but less conformal doses to PGTVs than IMRT did and comparable doses to PSV and PPS. Volumes of bladder and rectum receiving doses higher than 65 Gy were similar for both plans. However, volumes receiving less than 65 Gy were significantly reduced, i.e., protons reduced integral dose by 45.6 % and 26.5 % for rectum and bladder, respectively. This volume-sparing was also seen in femoral heads and penile bulb. Protons delivered comparable doses to targets in dose homogeneity and conformity and spared normal tissues from intermediate-to-low doses better than IMRT did. Further improvement of dose sparing and changes in homogeneity and conformity may be achieved by reducing proton range uncertainties and from implementing intensity modulation.
- 20 January 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (3_suppl) , 369
A treatment planning evaluation of protons versus IMRT in pancreatic cancer: A comparative study.
369 Background: The purpose of this study is to investigate dose distributions of proton and intensity-modulated radiation therapy (IMRT) photon treatment plans in patients with resected pancreatic adenocarcinoma, focusing specifically on dose reduction to the kidney, liver, and small bowel as organs at risk. Methods: Ten patients with pancreatic head adenocarcinoma underwent Whipple procedure between 2010 and 2013 were included in this study. Most of the patients had locally advanced disease (T3-4N1). All patients were simulated with contrast-enhanced CT imaging. The clinical target volume (CTV) consisted of the pre-operative extent of tumor plus a 10 mm manual expansion in all directions. The planning target volume (PTV) was generated by a further expansion on the CTV ranging from 10-15 mm. A dose of 50.4 Gy given in 28 fractions was delivered to the PTV. All plans were optimized to allow 95% isodose coverage of at least 95% of the PTV. Dose-volume histograms, conformity index (CI), uniformity index (UI), homogeneity index (HI), were calculated and analyzed in order to compare plans between the two modalities. The OAR being evaluated in this study are the kidneys, liver, small bowel, and spinal cord. To determine statistical significance, ANOVA and two-tailed paired t-tests were performed for all data parameters. Results: The proton plans resulted in a lower mean kidney dose (3.17 Gy vs. 9.59 Gy, p=0.039), a lower dose delivered to 1/3 of the liver, D1/3, (0.25 Gy vs. 4.56 Gy, p=0.003), and a lower mean liver dose (1.83 Gy vs. 5.24 Gy, p=0.021). See table for a summary of the results. Conclusions: For patients receiving postoperative radiotherapy for pancreatic cancer, the proton plans are technically feasible and dosimetrically appealing with superior organ at risk sparing compared to IMRT photon treatment plans.[Table: see text]
- 20 January 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (3_suppl) , 369
A treatment planning evaluation of protons versus IMRT in pancreatic cancer: A comparative study.
369 Background: The purpose of this study is to investigate dose distributions of proton and intensity-modulated radiation therapy (IMRT) photon treatment plans in patients with resected pancreatic adenocarcinoma, focusing specifically on dose reduction to the kidney, liver, and small bowel as organs at risk. Methods: Ten patients with pancreatic head adenocarcinoma underwent Whipple procedure between 2010 and 2013 were included in this study. Most of the patients had locally advanced disease (T3-4N1). All patients were simulated with contrast-enhanced CT imaging. The clinical target volume (CTV) consisted of the pre-operative extent of tumor plus a 10 mm manual expansion in all directions. The planning target volume (PTV) was generated by a further expansion on the CTV ranging from 10-15 mm. A dose of 50.4 Gy given in 28 fractions was delivered to the PTV. All plans were optimized to allow 95% isodose coverage of at least 95% of the PTV. Dose-volume histograms, conformity index (CI), uniformity index (UI), homogeneity index (HI), were calculated and analyzed in order to compare plans between the two modalities. The OAR being evaluated in this study are the kidneys, liver, small bowel, and spinal cord. To determine statistical significance, ANOVA and two-tailed paired t-tests were performed for all data parameters. Results: The proton plans resulted in a lower mean kidney dose (3.17 Gy vs. 9.59 Gy, p=0.039), a lower dose delivered to 1/3 of the liver, D1/3, (0.25 Gy vs. 4.56 Gy, p=0.003), and a lower mean liver dose (1.83 Gy vs. 5.24 Gy, p=0.021). See table for a summary of the results. Conclusions: For patients receiving postoperative radiotherapy for pancreatic cancer, the proton plans are technically feasible and dosimetrically appealing with superior organ at risk sparing compared to IMRT photon treatment plans.[Table: see text]
- 20 January 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (3) , 167
A comparison of proton and photon radiotherapy in reducing cardiac exposure for patients receiving radiation therapy for distal and esophagogastric junction cancer.
167 Background: Recent studies indicate that radiation exposure to heart may have a greater impact on perioperative cardiac morbidities than do other clinical factors. The purpose of this study is to investigate dose distributions of proton and photon treatment plans in patients (pts) with distal and esophagogastric junction (GEJ) carcinoma, focusing specifically on dose reduction to cardiac structures. Methods: Ten pts between 2010 and 2013 were included in this study. Three separate plans were generated for each patient: 3D proton plan, 3D photon plan, and Intensity modulated radiotherapy (IMRT) photon plan. The clinical target volume (CTV) consisted of the pre-operative extent of tumor plus a 10mm manual expansion in all directions. The planning target volume (PTV) was generated by a further expansion on the CTV ranging from 10-15mm. A dose of 50.4Gy given in 28 fractions was delivered to the PTV. All plans were optimized to allow 90% isodose coverage of at least 95% of the PTV. Dose-volume histograms were calculated and analyzed in order to compare plans between the three modalities. ANOVA and two-tailed paired t-tests were performed for all data parameters. Results: The 3D proton plans showed decreased dose to partial volumes of the entire heart, arteries, valves, atria, and ventricles in comparison to both the IMRT and 3D photon plans (see Table). The IMRT plans showed decreased dose delivered to the LAD artery, pericardium, and atria in comparison to the 3D photon plans (see Table). Conclusions: For pts receiving radiation therapy for distal esophageal and GEJ cancer, proton plans are technically feasible with adequate coverage while resulting in lower dose to cardiac structures. This may result in decreased cardiac toxicity and less complications in a multimodality setting. [Table: see text]
- 20 January 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (3) , 167
A comparison of proton and photon radiotherapy in reducing cardiac exposure for patients receiving radiation therapy for distal and esophagogastric junction cancer.
167 Background: Recent studies indicate that radiation exposure to heart may have a greater impact on perioperative cardiac morbidities than do other clinical factors. The purpose of this study is to investigate dose distributions of proton and photon treatment plans in patients (pts) with distal and esophagogastric junction (GEJ) carcinoma, focusing specifically on dose reduction to cardiac structures. Methods: Ten pts between 2010 and 2013 were included in this study. Three separate plans were generated for each patient: 3D proton plan, 3D photon plan, and Intensity modulated radiotherapy (IMRT) photon plan. The clinical target volume (CTV) consisted of the pre-operative extent of tumor plus a 10mm manual expansion in all directions. The planning target volume (PTV) was generated by a further expansion on the CTV ranging from 10-15mm. A dose of 50.4Gy given in 28 fractions was delivered to the PTV. All plans were optimized to allow 90% isodose coverage of at least 95% of the PTV. Dose-volume histograms were calculated and analyzed in order to compare plans between the three modalities. ANOVA and two-tailed paired t-tests were performed for all data parameters. Results: The 3D proton plans showed decreased dose to partial volumes of the entire heart, arteries, valves, atria, and ventricles in comparison to both the IMRT and 3D photon plans (see Table). The IMRT plans showed decreased dose delivered to the LAD artery, pericardium, and atria in comparison to the 3D photon plans (see Table). Conclusions: For pts receiving radiation therapy for distal esophageal and GEJ cancer, proton plans are technically feasible with adequate coverage while resulting in lower dose to cardiac structures. This may result in decreased cardiac toxicity and less complications in a multimodality setting. [Table: see text]
- Open Access
- 1 February 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 143 (2-4) , 513-518
Microdosimetric comparison of scanned and conventional proton beams used in radiation therapy
Multiple groups have hypothesised that the use of scanning beams in proton therapy will reduce the neutron component of secondary radiation in comparison with conventional methods with a corresponding reduction in risks of radiation-induced cancers. Loma Linda University Medical Center (LLUMC) has had FDA marketing clearance for scanning beams since 1988 and an experimental scanning beam has been available at the LLUMC proton facility since 2001. The facility has a dedicated research room with a scanning beam and fast switching that allows its use during patient treatments. Dosimetric measurements and microdosimetric distributions for a scanned beam are presented and compared with beams produced with the conventional methods presently used in proton therapy.
- 1 February 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 143 (2-4) , 513-518
Open AccessMicrodosimetric comparison of scanned and conventional proton beams used in radiation therapy
Multiple groups have hypothesised that the use of scanning beams in proton therapy will reduce the neutron component of secondary radiation in comparison with conventional methods with a corresponding reduction in risks of radiation-induced cancers. Loma Linda University Medical Center (LLUMC) has had FDA marketing clearance for scanning beams since 1988 and an experimental scanning beam has been available at the LLUMC proton facility since 2001. The facility has a dedicated research room with a scanning beam and fast switching that allows its use during patient treatments. Dosimetric measurements and microdosimetric distributions for a scanned beam are presented and compared with beams produced with the conventional methods presently used in proton therapy.