Khosrow Bargi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Khosrow Bargi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Aliakbar Shakeri
University of Tehran
2 shared publications - Amirreza Nilav
University of Tehran
2 shared publications Hossein Sadaee
Ph.D. Student of Geotechnical Engineering, Civil Faculty, Iran University of Science and Technology (IUST), Tehran, Iran
1 shared publicationMahdi Izadi
University of Tehran
1 shared publicationMasoud Moghaddasi Kuchaksarai
1 shared publication- Mehdi Jalili
Ph.D. Student of Geotechnical Engineering, Civil Faculty, Iran University of Science and Technology (IUST), Tehran, Iran
1 shared publication
Latest Publications
- 10 November 2026
- Published by SAGE Publications in Bridge Structures
Enhanced seismic and structural response of cable-stayed bridges with micro-cables
Cable-stayed bridges (CSBs) are favored for long spans, but their performance and cost are dominated by the cable system. Conventional fan, semi-fan, and harp layouts often require thick cables, leading to high fabrication, maintenance, and replacement expenses. This study introduces a novel “Micro-cables” arrangement, a hybrid fan-harp system designed to overcome these challenges. The configuration’s efficiency is evaluated through comprehensive numerical analysis of CSB models featuring five different pylon shapes and spans ranging from 50 m to 310 m. Using nonlinear static and spectral-based seismic analyses, the study compares the proposed system to traditional layouts. The results confirm significant performance enhancements. Quantitatively, the Micro-cables layout reduces pylon head displacement by up to 32% under dead load and 27% under traffic load compared to the harp configuration. Furthermore, individual cable axial forces are decreased by approximately 68% (distributed across the denser network of 360 micro-cables), and pylon base moments are lowered by 22–35%, depending on the pylon geometry. These structural improvements reduce seismic structural demands and suggest a potential for optimizing material usage, particularly in the cable system. While comprehensive lifecycle cost and constructability analyses are required for full validation, the structural improvements establish the Micro-cables system as a promising alternative worthy of further investigation.
- 10 November 2026
- Published by SAGE Publications in Bridge Structures
Enhanced seismic and structural response of cable-stayed bridges with micro-cables
Cable-stayed bridges (CSBs) are favored for long spans, but their performance and cost are dominated by the cable system. Conventional fan, semi-fan, and harp layouts often require thick cables, leading to high fabrication, maintenance, and replacement expenses. This study introduces a novel “Micro-cables” arrangement, a hybrid fan-harp system designed to overcome these challenges. The configuration’s efficiency is evaluated through comprehensive numerical analysis of CSB models featuring five different pylon shapes and spans ranging from 50 m to 310 m. Using nonlinear static and spectral-based seismic analyses, the study compares the proposed system to traditional layouts. The results confirm significant performance enhancements. Quantitatively, the Micro-cables layout reduces pylon head displacement by up to 32% under dead load and 27% under traffic load compared to the harp configuration. Furthermore, individual cable axial forces are decreased by approximately 68% (distributed across the denser network of 360 micro-cables), and pylon base moments are lowered by 22–35%, depending on the pylon geometry. These structural improvements reduce seismic structural demands and suggest a potential for optimizing material usage, particularly in the cable system. While comprehensive lifecycle cost and constructability analyses are required for full validation, the structural improvements establish the Micro-cables system as a promising alternative worthy of further investigation.
- 29 May 2024
- Published by Taylor & Francis in Structural Engineering International
- Vol. 35 (2) , 191-202
Evaluation of Pylon Shape and Cable Layout Interaction on the Seismic Behavior of Cable-stayed Bridges
- 29 May 2024
- Published by Taylor & Francis in Structural Engineering International
- Vol. 35 (2) , 191-202
Evaluation of Pylon Shape and Cable Layout Interaction on the Seismic Behavior of Cable-stayed Bridges
- 1 August 2022
- Published by American Society of Civil Engineers (ASCE) in Practice Periodical on Structural Design and Construction
- Vol. 27 (3) , 04022034
Seismic Enhancement of Pile-Supported Wharf Using Tension-Only Cables
Pile-supported wharf structures exposed to seismic hazards may suffer severe damage. As such, an effective approach for enhancing the seismic performance of these structures is vital. This study introduces a new retrofitting method, mitigating earthquake-induced damage by fastening the deck of a wharf to the shoreline with an array of tension cables. At first, using the Macro-Simulink model, a parametric study was carried out to assess the contribution of the cable with different stiffness on the seismic response of the wharves. In the parametric study, the seismic performance of a wide range of pile-supported wharves having different periods and levels of hysteretic deterioration is investigated. Maximum and residual deck drifts as well as maximum shear demands on the piles are among the investigated seismic responses. Second, the effectiveness of the proposed method is evaluated by nonlinear time history analysis of a typical pile-supported wharf. The obtained results indicate that the tension-only cables reduce the maximum and residual deck drift of the pile-supported wharf and significantly decrease the seismic demand on the piles. In the nonlinear time history analysis, with retrofitting section piles performance enhances remarkably with almost all the piles remaining in the elastic zone. Moreover, the contribution of the proposed technique is more pronounced in the case of more vulnerable wharves.
- 1 August 2022
- Published by American Society of Civil Engineers (ASCE) in Practice Periodical on Structural Design and Construction
- Vol. 27 (3) , 04022034
Seismic Enhancement of Pile-Supported Wharf Using Tension-Only Cables
Pile-supported wharf structures exposed to seismic hazards may suffer severe damage. As such, an effective approach for enhancing the seismic performance of these structures is vital. This study introduces a new retrofitting method, mitigating earthquake-induced damage by fastening the deck of a wharf to the shoreline with an array of tension cables. At first, using the Macro-Simulink model, a parametric study was carried out to assess the contribution of the cable with different stiffness on the seismic response of the wharves. In the parametric study, the seismic performance of a wide range of pile-supported wharves having different periods and levels of hysteretic deterioration is investigated. Maximum and residual deck drifts as well as maximum shear demands on the piles are among the investigated seismic responses. Second, the effectiveness of the proposed method is evaluated by nonlinear time history analysis of a typical pile-supported wharf. The obtained results indicate that the tension-only cables reduce the maximum and residual deck drift of the pile-supported wharf and significantly decrease the seismic demand on the piles. In the nonlinear time history analysis, with retrofitting section piles performance enhances remarkably with almost all the piles remaining in the elastic zone. Moreover, the contribution of the proposed technique is more pronounced in the case of more vulnerable wharves.
- 6 June 2019
- Published by Springer Nature in Frontiers of Structural and Civil Engineering
- Vol. 13 (5) , 1105-1119
Improvement of mechanical behavior of buried pipelines subjected to strike-slip faulting using textured pipeline
- 6 June 2019
- Published by Springer Nature in Frontiers of Structural and Civil Engineering
- Vol. 13 (5) , 1105-1119
Improvement of mechanical behavior of buried pipelines subjected to strike-slip faulting using textured pipeline
- Open Access
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Latin American Journal of Solids and Structures
- Vol. 16 (7)
Enhancement the Fatigue Life of Floating Breakwater Mooring System Using Tuned Liquid Column Damper
Safety is a key design criterion for floating structures. A high rate of mooring accidents has been reported over the past decades. Preventing mooring line failure is a key design objective for floating breakwater systems. The mooring system comprises sets of mooring lines anchored to the seabed. These components are exposed to highly cyclic nonlinear load fluctuations induced by an irregular wave climate during their service life. DNVGL-OS-E301 classifies the mooring lines for floating breakwaters as long-term elements that should be evaluated according to the fatigue limit state. Fatigue of mooring lines needs to be monitored and evaluated to warrant the station keeping and integrity of overall system. Applying an additional control device to a floating breakwater mitigates the structural response and hence mobilized tension in mooring system. The focus of present study was to examine the effect of an additional control device on fatigue life of mooring lines for floating breakwaters. To evaluate the effect of a control device on the fatigue behavior of mooring lines, a floating breakwater was simulated with a tuned liquid column damper (TLCD) attached. A time-dependent approach based on S-N curves in conjunction with the Palmgren-Miner rule was employed to evaluate the mooring line fatigue. This paper presents a further parametric study focused on the effect of TLCD on fairlead point displacement, mobilized tension, damage rate, and fatigue life of mooring lines. The results showed that TLCD increased the fatigue life of mooring line and thus dramatically decreased the likelihood of the mooring system being damaged by fatigue. This would reduce the maintenance costs and increase the lifetime and operational safety of floating breakwater. In addition, the presented case study showed that failure probability of mooring lines against fatigue damage was also reduced and was acceptable for the safety factor defined in DNVGL-OS-E301. This proposed approach of applying a TLCD is a practical tool for designing the components of a floating breakwater more efficiently.
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Latin American Journal of Solids and Structures
- Vol. 16 (7)
Open AccessEnhancement the Fatigue Life of Floating Breakwater Mooring System Using Tuned Liquid Column Damper
Safety is a key design criterion for floating structures. A high rate of mooring accidents has been reported over the past decades. Preventing mooring line failure is a key design objective for floating breakwater systems. The mooring system comprises sets of mooring lines anchored to the seabed. These components are exposed to highly cyclic nonlinear load fluctuations induced by an irregular wave climate during their service life. DNVGL-OS-E301 classifies the mooring lines for floating breakwaters as long-term elements that should be evaluated according to the fatigue limit state. Fatigue of mooring lines needs to be monitored and evaluated to warrant the station keeping and integrity of overall system. Applying an additional control device to a floating breakwater mitigates the structural response and hence mobilized tension in mooring system. The focus of present study was to examine the effect of an additional control device on fatigue life of mooring lines for floating breakwaters. To evaluate the effect of a control device on the fatigue behavior of mooring lines, a floating breakwater was simulated with a tuned liquid column damper (TLCD) attached. A time-dependent approach based on S-N curves in conjunction with the Palmgren-Miner rule was employed to evaluate the mooring line fatigue. This paper presents a further parametric study focused on the effect of TLCD on fairlead point displacement, mobilized tension, damage rate, and fatigue life of mooring lines. The results showed that TLCD increased the fatigue life of mooring line and thus dramatically decreased the likelihood of the mooring system being damaged by fatigue. This would reduce the maintenance costs and increase the lifetime and operational safety of floating breakwater. In addition, the presented case study showed that failure probability of mooring lines against fatigue damage was also reduced and was acceptable for the safety factor defined in DNVGL-OS-E301. This proposed approach of applying a TLCD is a practical tool for designing the components of a floating breakwater more efficiently.
- Open Access
- 1 September 2018
- Vol. 2 (2) , 241-250
Prediction of Local Seismic Damage in Jacket-type Offshore Platforms
- 1 September 2018
- Vol. 2 (2) , 241-250
Open AccessPrediction of Local Seismic Damage in Jacket-type Offshore Platforms
- Open Access
- 1 July 2015
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 19 (5) , 1375-1384
Use of applied element method for structural analysis
- 1 July 2015
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 19 (5) , 1375-1384
Open AccessUse of applied element method for structural analysis
- 28 March 2008
- Published by American Society of Civil Engineers (ASCE)
- p. 939-951
Knapsack Placing of Blocks Assess on Wall Stability in Seismic Regions and Proper Section Recommendation
Concrete block quay walls consist of solid or hollow concrete blocks sitting on each other to form the wall section. In this type of walls geotechnical conditions, design calculations and the ability of contractor determine the blocks dimensions. In these walls, resistance against applied loads is provided by wall weight. To reduce active soil pressure and increasing the wall stability in seismic regions, a hunchback section is formed by placing a protruding knapsack to the landside. In the knapsack formation, wall stability will be increased. For knapsack section special considerations such as trimming the blocks, more accuracy in setting the blocks and consequently increases in construction costs should be considered. In this article, by conducting pseudo-static analysis in different earthquake levels and for various wall heights relative comparisons have been evaluated between knapsack and simple (vertical front face) sections. Finally suggestions about proper section of quay wall have been recommended.
- 28 March 2008
- Published by American Society of Civil Engineers (ASCE)
- p. 939-951
Knapsack Placing of Blocks Assess on Wall Stability in Seismic Regions and Proper Section Recommendation
Concrete block quay walls consist of solid or hollow concrete blocks sitting on each other to form the wall section. In this type of walls geotechnical conditions, design calculations and the ability of contractor determine the blocks dimensions. In these walls, resistance against applied loads is provided by wall weight. To reduce active soil pressure and increasing the wall stability in seismic regions, a hunchback section is formed by placing a protruding knapsack to the landside. In the knapsack formation, wall stability will be increased. For knapsack section special considerations such as trimming the blocks, more accuracy in setting the blocks and consequently increases in construction costs should be considered. In this article, by conducting pseudo-static analysis in different earthquake levels and for various wall heights relative comparisons have been evaluated between knapsack and simple (vertical front face) sections. Finally suggestions about proper section of quay wall have been recommended.