Theodore V. Vorburger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Theodore V. Vorburger has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- John Song
Physical Measurement Laboratory, National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899, USA
2 shared publications - Robert M. Thompson
National Institute of Standards and Technology, Gaithersburg, MD 20899
2 shared publications - A. Zheng
National Institute of Standards and Technology, Physical Measurement Laboratory, Gaithersburg, MD 20899, USA
1 shared publication - Che Bong Joung
Manufacturing Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899
1 shared publication J Fu
National Institute of Standards and Technology
1 shared publicationJ Song
National Institute of Standards and Technology
1 shared publication
Latest Publications
- 1 December 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 644-73
The Second National Ballistics Imaging Comparison (NBIC-2)
In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF's National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.
- 1 December 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 644-73
The Second National Ballistics Imaging Comparison (NBIC-2)
In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF's National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.
- 1 January 2014
- Published by IOP Publishing in Surface Topography: Metrology and Properties
- Vol. 2 (1) , 14012
Applications of surface metrology in firearm identification
- 1 January 2014
- Published by IOP Publishing in Surface Topography: Metrology and Properties
- Vol. 2 (1) , 14012
Applications of surface metrology in firearm identification
- 1 May 2011
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 116 (3) , 647-653
Selecting Valid Correlation Areas for Automated Bullet Identification System Based on Striation Detection
Some automated bullet identification systems calculate a correlation score between two land impressions to measure their similarity. When extracting a compressed profile from the land impression of a fired bullet, inclusion of areas that do not contain valid individual striation information may lead to sub-optimal extraction and therefore may deteriorate the correlation result. In this paper, an edge detection algorithm and selection process are used together to locate the edge points of all tool-mark features and filter out those not corresponding to striation marks. Edge points of the resulting striation marks are reserved and expanded to generate a mask image. By imposing the mask image on the topography image, the weakly striated area(s) are removed from the expressed profile extraction. Using this method, 48 bullets fired from 12 gun barrels of six manufacturers resulted in a higher matching rate than previous studies.
- 1 May 2011
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 116 (3) , 647-653
Selecting Valid Correlation Areas for Automated Bullet Identification System Based on Striation Detection
Some automated bullet identification systems calculate a correlation score between two land impressions to measure their similarity. When extracting a compressed profile from the land impression of a fired bullet, inclusion of areas that do not contain valid individual striation information may lead to sub-optimal extraction and therefore may deteriorate the correlation result. In this paper, an edge detection algorithm and selection process are used together to locate the edge points of all tool-mark features and filter out those not corresponding to striation marks. Edge points of the resulting striation marks are reserved and expanded to generate a mask image. By imposing the mask image on the topography image, the weakly striated area(s) are removed from the expressed profile extraction. Using this method, 48 bullets fired from 12 gun barrels of six manufacturers resulted in a higher matching rate than previous studies.
- 1 January 2010
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 115 (1) , 1-6
An iterative image registration algorithm by optimizing similarity measurement
A new registration algorithm based on Newton-Raphson iteration is proposed to align images with rigid body transformation. A set of transformation parameters consisting of translation in x and y and rotation angle around z is calculated by optimizing a specified similarity metric using the Newton-Raphson method. This algorithm has been tested by registering and correlating pairs of topography measurements of nominally identical NIST Standard Reference Material (SRM 2461) standard cartridge cases, and very good registration accuracy has been obtained.
- 1 January 2010
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 115 (1) , 1-6
An iterative image registration algorithm by optimizing similarity measurement
A new registration algorithm based on Newton-Raphson iteration is proposed to align images with rigid body transformation. A set of transformation parameters consisting of translation in x and y and rotation angle around z is calculated by optimizing a specified similarity metric using the Newton-Raphson method. This algorithm has been tested by registering and correlating pairs of topography measurements of nominally identical NIST Standard Reference Material (SRM 2461) standard cartridge cases, and very good registration accuracy has been obtained.
- 1 July 2009
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 114 (4) , 201-214
Characterization of Probe Dynamic Behaviors in Critical Dimension Atomic Force Microscopy
This paper describes a detailed computational model of the interaction between an atomic force microscope probe tip and a sample surface. The model provides analyses of dynamic behaviors of the tip to estimate the probe deflections due to surface intermittent contact and the resulting dimensional biases and uncertainties. Probe tip and cantilever beam responses to intermittent contact between the probe tip and sample surface are computed using the finite element method. Intermittent contacts with a wall and a horizontal surface are computed and modeled, respectively. Using a 75 nm Critical Dimension (CD) tip as an example, the responses of the probe to interaction forces between the sample surface and the probe tip are shown in both time and frequency domains. In particular, interaction forces between the tip and both a vertical wall and a horizontal surface of a silicon sample are modeled using Lennard-Jones theory. The Snap-in and Snap-out of the probe tip in surface scanning are calculated and shown in the time domain. Based on the given tip-sample interaction force model, the calculation includes the compliance of the probe and dynamic forces generated by an excitation. Cantilever and probe tip deflections versus interaction forces in the time domain can be derived for both vertical contact with a plateau and horizontal contact with a side wall. Dynamic analysis using the finite element method and Lennard-Jones model provide a unique means to analyze the interaction of the probe and sample, including calculation of the deflection and the gap between the probe tip and the measured sample surface.
- 1 July 2009
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 114 (4) , 201-214
Characterization of Probe Dynamic Behaviors in Critical Dimension Atomic Force Microscopy
This paper describes a detailed computational model of the interaction between an atomic force microscope probe tip and a sample surface. The model provides analyses of dynamic behaviors of the tip to estimate the probe deflections due to surface intermittent contact and the resulting dimensional biases and uncertainties. Probe tip and cantilever beam responses to intermittent contact between the probe tip and sample surface are computed using the finite element method. Intermittent contacts with a wall and a horizontal surface are computed and modeled, respectively. Using a 75 nm Critical Dimension (CD) tip as an example, the responses of the probe to interaction forces between the sample surface and the probe tip are shown in both time and frequency domains. In particular, interaction forces between the tip and both a vertical wall and a horizontal surface of a silicon sample are modeled using Lennard-Jones theory. The Snap-in and Snap-out of the probe tip in surface scanning are calculated and shown in the time domain. Based on the given tip-sample interaction force model, the calculation includes the compliance of the probe and dynamic forces generated by an excitation. Cantilever and probe tip deflections versus interaction forces in the time domain can be derived for both vertical contact with a plateau and horizontal contact with a side wall. Dynamic analysis using the finite element method and Lennard-Jones model provide a unique means to analyze the interaction of the probe and sample, including calculation of the deflection and the gap between the probe tip and the measured sample surface.
- 19 October 2001
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 12 (11) , 2002-2008
The role of periodic interferometer errors in the calibration of capacitance displacement sensors for nanometrology applications
- 19 October 2001
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 12 (11) , 2002-2008
The role of periodic interferometer errors in the calibration of capacitance displacement sensors for nanometrology applications