Robert M. Thompson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert M. Thompson has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- John Song
Physical Measurement Laboratory, National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899, USA
3 shared publications - A. Zheng
National Institute of Standards and Technology, Physical Measurement Laboratory, Gaithersburg, MD 20899, USA
2 shared publications - Johannes A. Soons
Physical Measurement Laboratory, National Institute of Standards and Technology (NIST), Gaithersburg, MD 20899, USA
2 shared publications - Mingsi Tong
National Institute of Standards and Technology, Gaithersburg, MD 20899 USA
2 shared publications - Theodore V. Vorburger
National Institute of Standards and Technology, Gaithersburg, MD 20899
2 shared publications - Wei Chu
National Institute of Standards and Technology, Gaithersburg, MD 20899 USA
2 shared publications
Latest Publications
- Open Access
- 27 January 2020
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 125, 125004
NIST Ballistics Toolmark Research Database
In 2009, a report by the National Academies called into question, amongst other issues, the objectivity of visual toolmark identification by firearms examiners. The National Academies recommended development of objective toolmark identification criteria and error rate estimates. Industry, academia, and government laboratories are pursuing two promising approaches towards this goal: 1) development of mathematical criteria and advanced algorithms for the objective and automated identification and scoring of potential matches, and 2) supplementing traditional reflectance microscopy images with three- dimensional surface topography measurement data. Development and validation of both these approaches to objective toolmark identification are hindered by a lack of access to toolmark data sets that 1) represent the large variety of ballistic toolmarks encountered by toolmark examiners, and 2) represent challenging identification scenarios, such as those posed by consecutively manufactured firearms components. The NIST Ballistics Toolmark Research Database enables researchers to test and validate new approaches to objective, mathematics-based, toolmark identification while easing the transition to three- dimensional surface topography data. The database will provide a foundation for a scientific knowledge base on the degree of similarity that can be found between marks made by different firearms and the variability in marks made by an individual firearm. The current, fairly limited, knowledge base is a fundamental barrier to the development and validation of objective mathematical similarity criteria, and associated confidence limits, applicable to a broad range of firearms and ammunition brands.
- 27 January 2020
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 125, 125004
Open AccessNIST Ballistics Toolmark Research Database
In 2009, a report by the National Academies called into question, amongst other issues, the objectivity of visual toolmark identification by firearms examiners. The National Academies recommended development of objective toolmark identification criteria and error rate estimates. Industry, academia, and government laboratories are pursuing two promising approaches towards this goal: 1) development of mathematical criteria and advanced algorithms for the objective and automated identification and scoring of potential matches, and 2) supplementing traditional reflectance microscopy images with three- dimensional surface topography measurement data. Development and validation of both these approaches to objective toolmark identification are hindered by a lack of access to toolmark data sets that 1) represent the large variety of ballistic toolmarks encountered by toolmark examiners, and 2) represent challenging identification scenarios, such as those posed by consecutively manufactured firearms components. The NIST Ballistics Toolmark Research Database enables researchers to test and validate new approaches to objective, mathematics-based, toolmark identification while easing the transition to three- dimensional surface topography data. The database will provide a foundation for a scientific knowledge base on the degree of similarity that can be found between marks made by different firearms and the variability in marks made by an individual firearm. The current, fairly limited, knowledge base is a fundamental barrier to the development and validation of objective mathematical similarity criteria, and associated confidence limits, applicable to a broad range of firearms and ammunition brands.
- 1 December 2019
- Published by Elsevier in Forensic Science International
- Vol. 305, 109964
Fired bullet signature correlation using the Congruent Matching Profile Segments (CMPS) method
- 1 December 2019
- Published by Elsevier in Forensic Science International
- Vol. 305, 109964
Fired bullet signature correlation using the Congruent Matching Profile Segments (CMPS) method
- 1 February 2017
- Published by Elsevier in Forensic Science International
- Vol. 271, 98-106
Applying 3D measurements and computer matching algorithms to two firearm examination proficiency tests
- 1 February 2017
- Published by Elsevier in Forensic Science International
- Vol. 271, 98-106
Applying 3D measurements and computer matching algorithms to two firearm examination proficiency tests
- 25 November 2015
- Published by Wiley in Journal of Forensic Sciences
- Vol. 61 (2) , 509-519
Dimensional Review of Scales for Forensic Photography
Scales for photography provide a geometrical reference in the photographic documentation of a crime scene, pattern, or item of evidence. The ABFO No. 2 Standard Reference Scale (1) is used by the forensic science community as an accurate reference scale. We investigated the overall accuracy of the major centimeter graduations, internal/external diameters of the circles, error in placement of the circle centers, and leg perpendicularity. Four vendors were selected for the scales, and the features were measured on a vision‐based coordinate measurement system. The scales were well within the specified tolerance for the length graduations. After 4 years, the same scales were measured to determine what change could be measured. The scales demonstrated acceptable stability in the scale length and center‐to‐center measurements; however, the perpendicularity exhibited change. The study results indicate that scale quality checks using certified metal rulers are good practice.
- 25 November 2015
- Published by Wiley in Journal of Forensic Sciences
- Vol. 61 (2) , 509-519
Dimensional Review of Scales for Forensic Photography
Scales for photography provide a geometrical reference in the photographic documentation of a crime scene, pattern, or item of evidence. The ABFO No. 2 Standard Reference Scale (1) is used by the forensic science community as an accurate reference scale. We investigated the overall accuracy of the major centimeter graduations, internal/external diameters of the circles, error in placement of the circle centers, and leg perpendicularity. Four vendors were selected for the scales, and the features were measured on a vision‐based coordinate measurement system. The scales were well within the specified tolerance for the length graduations. After 4 years, the same scales were measured to determine what change could be measured. The scales demonstrated acceptable stability in the scale length and center‐to‐center measurements; however, the perpendicularity exhibited change. The study results indicate that scale quality checks using certified metal rulers are good practice.
- 1 December 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 644-73
The Second National Ballistics Imaging Comparison (NBIC-2)
In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF's National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.
- 1 December 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 644-73
The Second National Ballistics Imaging Comparison (NBIC-2)
In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF's National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.
- 1 November 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 575-82
Fired Cartridge Case Identification Using Optical Images and the Congruent Matching Cells (CMC) Method
The Congruent Matching Cells (CMC) method for ballistics identification was invented at the National Institute of Standards and Technology (NIST). The CMC method is based on the correlation of pairs of small correlation cells instead of the correlation of entire images. Four identification parameters - T CCF, T θ, T x and T y are proposed for identifying correlated cell pairs originating from the same firearm. The correlation conclusion (matching or non-matching) is determined by whether the number of CMC is ≥ 6. This method has been previously validated using a set of 780 pair-wise 3D topography images. However, most ballistic images stored in current local and national databases are in an optical intensity (grayscale) format. As a result, the reliability of applying the CMC method on optical intensity images is an important issue. In this paper, optical intensity images of breech face impressions captured on the same set of 40 cartridge cases are correlated and analyzed for the validation test of CMC method using optical images. This includes correlations of 63 pairs of matching images and 717 pairs of non-matching images under top ring lighting. Tests of the method do not produce any false identification (false positive) or false exclusion (false negative) results, which support the CMC method and the proposed identification criterion, C = 6, for firearm breech face identifications using optical intensity images.
- 1 November 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 575-82
Fired Cartridge Case Identification Using Optical Images and the Congruent Matching Cells (CMC) Method
The Congruent Matching Cells (CMC) method for ballistics identification was invented at the National Institute of Standards and Technology (NIST). The CMC method is based on the correlation of pairs of small correlation cells instead of the correlation of entire images. Four identification parameters - T CCF, T θ, T x and T y are proposed for identifying correlated cell pairs originating from the same firearm. The correlation conclusion (matching or non-matching) is determined by whether the number of CMC is ≥ 6. This method has been previously validated using a set of 780 pair-wise 3D topography images. However, most ballistic images stored in current local and national databases are in an optical intensity (grayscale) format. As a result, the reliability of applying the CMC method on optical intensity images is an important issue. In this paper, optical intensity images of breech face impressions captured on the same set of 40 cartridge cases are correlated and analyzed for the validation test of CMC method using optical images. This includes correlations of 63 pairs of matching images and 717 pairs of non-matching images under top ring lighting. Tests of the method do not produce any false identification (false positive) or false exclusion (false negative) results, which support the CMC method and the proposed identification criterion, C = 6, for firearm breech face identifications using optical intensity images.
- 1 May 2011
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 116 (3) , 647-653
Selecting Valid Correlation Areas for Automated Bullet Identification System Based on Striation Detection
Some automated bullet identification systems calculate a correlation score between two land impressions to measure their similarity. When extracting a compressed profile from the land impression of a fired bullet, inclusion of areas that do not contain valid individual striation information may lead to sub-optimal extraction and therefore may deteriorate the correlation result. In this paper, an edge detection algorithm and selection process are used together to locate the edge points of all tool-mark features and filter out those not corresponding to striation marks. Edge points of the resulting striation marks are reserved and expanded to generate a mask image. By imposing the mask image on the topography image, the weakly striated area(s) are removed from the expressed profile extraction. Using this method, 48 bullets fired from 12 gun barrels of six manufacturers resulted in a higher matching rate than previous studies.
- 1 May 2011
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 116 (3) , 647-653
Selecting Valid Correlation Areas for Automated Bullet Identification System Based on Striation Detection
Some automated bullet identification systems calculate a correlation score between two land impressions to measure their similarity. When extracting a compressed profile from the land impression of a fired bullet, inclusion of areas that do not contain valid individual striation information may lead to sub-optimal extraction and therefore may deteriorate the correlation result. In this paper, an edge detection algorithm and selection process are used together to locate the edge points of all tool-mark features and filter out those not corresponding to striation marks. Edge points of the resulting striation marks are reserved and expanded to generate a mask image. By imposing the mask image on the topography image, the weakly striated area(s) are removed from the expressed profile extraction. Using this method, 48 bullets fired from 12 gun barrels of six manufacturers resulted in a higher matching rate than previous studies.