TNToshiaki Nitatori

Toshiaki Nitatori

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Toshiaki Nitatori has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automatic slice-alignment method in cardiac magnetic resonance imaging for evaluation of the right ventricle in patients with pulmonary hypertension

    by Kenichi Yokoyama, Shuhei Nitta, Shigehide Kuhara, Rieko Ishimura, Toshiya Kariyasu, Masamichi Imai, Toshiaki Nitatori, Tomoyuki Takeguchi, Taichiro Shiodera

    We propose a new automatic slice-alignment method, which enables right ventricular scan planning in addition to the left ventricular scan planning developed in our previous work, to simplify right ventricular cardiac scan planning and assess its accuracy and the clinical acceptability of the acquired imaging planes in the evaluation of patients with pulmonary hypertension. Steady-state free precession (SSFP) sequences covering the whole heart in the end-diastolic phase with ECG gating were used to acquire 2D axial multislice images. To realize right ventricular scan planning, two morphological feature points are added to be detected and a total of eight morphological features of the heart were extracted from these series of images, and six left ventricular planes and four right ventricular planes were calculated simultaneously based on the extracted features. The subjects were 33 patients (25 with chronic thromboembolic pulmonary hypertension and 8 with idiopathic pulmonary arterial hypertension). The four right ventricular reference planes including right ventricular short-axis, 4-chamber, 2-chamber, and 3-chamber images were evaluated. The acceptability of the acquired imaging planes was visually evaluated using a 4-point scale, and the angular differences between the results obtained by this method and by conventional manual annotation were measured for each view. The average visual scores were 3.9±0.4 for short-axis images, 3.8±0.4 for 4-chamber images, 3.8±0.4 for 2-chamber images, and 3.5±0.6 for 3-chamber images. The average angular differences were 8.7±5.3, 8.3±4.9, 8.1±4.8, and 7.9±5.3 degrees, respectively. The processing time was less than 2.5 seconds in all subjects. The proposed method, which enables right ventricular scan planning in addition to the left ventricular scan planning developed in our previous work, can provide clinically acceptable planes in a short time and is useful because special proficiency in performing cardiac MR for patients with right ventricles of various sizes and shapes is not required.


  • Non-contrast myocardial perfusion using a novel 4D magnetic resonance arterial spin labeling technique: Initial experience

    by Mitsue Miyazaki, Xiangzhi Zhou, Tsutomu Hoshino, Kenichi Yokoyama, Rieko Ishimura, Toshiaki Nitatori


    • 1 December 2002
      • Vol. 62  (14) , 808-15

    [Detection and diagnosis of coronary arteries using multi-detector CT].

    by Syuji Takahashi, Toshiaki Nitatori, Kenichi Yokoyama, Jyunichi Hachiya, Eisei Kachi, Hideaki Yoshino

    In this study coronary arteries were compared and evaluated in 41 cases using multidetector CT with slice thicknesses of 2 mm and 1 mm. All 323 segments including #1-3, 5-8, and 11 [based on the American Heart Association (AHA) classification system] were used: 163 segments of 2 mm and 160 segments of 1 mm. The images obtained were separated into fivelevels (0-4 points) of cardiac motion artifacts and evaluated based on volume rendering (VR) and partial maximum intensity projection (partial MIP). Of the results obtained, slice images of 1 mm in thickness were superior to those of 2 mm by 15.4% for sensitivity, 7.5% for specificity, and 8.2% for accuracy. On evaluation by segment, diagnostic accuracy was 2.88 +/- 0.57 for 2-mm slices and 3.28 +/- 0.59 for 1-mm slices of the left coronary artery, and 2.11 +/- 0.82 for 2-mm slices and 2.33 +/- 0.67 for 1-mm slices of the right coronary artery. Particularly for #6, a significantly high value was found for 1-mm slices (p < 0.05). Diagnostic accuracy was low in groups #2 and #3. On the basis of these findings, we were persuaded of the usefulness of MDCT for the evaluation of coronary arterial stenosed lesions, and we consider that diagnostic capability is improved by using thinner slices. We concluded that further studies would be necessary for visualization of the right coronary artery, which was seriously affected by cardiac motion artifacts.