René Heylen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
René Heylen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Cathy De Deyne
Department of Medicine and Life Sciences, Hasselt University, Diepenbeek, Belgium
2 shared publications - Ingrid Meex
Faculty of Medicine and Life Sciences, Hasselt University, Martelarenlaan 42, 3500 Hasselt, Belgium
2 shared publications - Jo Dens
Department of Medicine and Life Sciences, Hasselt University, Diepenbeek, Belgium
2 shared publications - Willem Boer
Department of Anaesthesiology, Intensive Care, Emergency Medicine and Pain Therapy, Ziekenhuis Oost-Limburg, Genk, Belgium
2 shared publications - Bert Ferdinande
Department of Cardiology, Hospital Oost-Limburg Genk, Belgium
1 shared publication - Cornelia Genbrugge
Department of Medicine and Life Sciences, Hasselt University, Diepenbeek, Belgium
1 shared publication
Latest Publications
- Open Access
- 1 December 2015
- Published by Springer Nature in Critical Care
- Vol. 19 (1) , 112
Increase in cerebral oxygenation during advanced life support in out-of-hospital patients is associated with return of spontaneous circulation
Introduction: By maintaining sufficient cerebral blood flow and oxygenation, the goal of cardiopulmonary resuscitation (CPR) is to preserve the pre-arrest neurological state. To date, cerebral monitoring abilities during CPR have been limited. Therefore, we investigated the time-course of cerebral oxygen saturation values (rSO2) during advanced life support in out-of-hospital cardiac arrest. Our primary aim was to compare rSO2 values during advanced life support from patients with return of spontaneous circulation (ROSC) to patients who did not achieve ROSC. Methods: We performed an observational study to measure rSO2 using Equanox™ (Nonin, Plymouth, MI) from the start of advanced life support in the pre-hospital setting. Results: rSO2 of 49 consecutive out-of-hospital cardiac arrest patients were analyzed. The total increase from initial rSO2 value until two minutes before ROSC or end of advanced life support efforts was significantly larger in the group with ROSC 16% (9 to 36) compared to the patients without ROSC 10% (4 to 15) (P = 0.02). Mean rSO2 from the start of measurement until two minutes before ROSC or until termination of advanced life support was higher in patients with ROSC than in those without, namely 39% ± 7 and 31% ± 4 (P = 0.05) respectively. Conclusions: During pre-hospital advanced life support, higher increases in rSO2 are observed in patients attaining ROSC, even before ROSC was clinically determined. Our findings suggest that rSO2 could be used in the future to guide patient tailored treatment during cardiac arrest and could therefore be a surrogate marker of the systemic oxygenation state of the patient.
- 1 December 2015
- Published by Springer Nature in Critical Care
- Vol. 19 (1) , 112
Open AccessIncrease in cerebral oxygenation during advanced life support in out-of-hospital patients is associated with return of spontaneous circulation
Introduction: By maintaining sufficient cerebral blood flow and oxygenation, the goal of cardiopulmonary resuscitation (CPR) is to preserve the pre-arrest neurological state. To date, cerebral monitoring abilities during CPR have been limited. Therefore, we investigated the time-course of cerebral oxygen saturation values (rSO2) during advanced life support in out-of-hospital cardiac arrest. Our primary aim was to compare rSO2 values during advanced life support from patients with return of spontaneous circulation (ROSC) to patients who did not achieve ROSC. Methods: We performed an observational study to measure rSO2 using Equanox™ (Nonin, Plymouth, MI) from the start of advanced life support in the pre-hospital setting. Results: rSO2 of 49 consecutive out-of-hospital cardiac arrest patients were analyzed. The total increase from initial rSO2 value until two minutes before ROSC or end of advanced life support efforts was significantly larger in the group with ROSC 16% (9 to 36) compared to the patients without ROSC 10% (4 to 15) (P = 0.02). Mean rSO2 from the start of measurement until two minutes before ROSC or until termination of advanced life support was higher in patients with ROSC than in those without, namely 39% ± 7 and 31% ± 4 (P = 0.05) respectively. Conclusions: During pre-hospital advanced life support, higher increases in rSO2 are observed in patients attaining ROSC, even before ROSC was clinically determined. Our findings suggest that rSO2 could be used in the future to guide patient tailored treatment during cardiac arrest and could therefore be a surrogate marker of the systemic oxygenation state of the patient.
- Open Access
- 1 March 2013
- Published by Springer Nature in Critical Care
- Vol. 17 (2) , R36
Feasibility of absolute cerebral tissue oxygen saturation during cardiopulmonary resuscitation
Introduction: Current monitoring during cardiopulmonary resuscitation (CPR) is limited to clinical observation of consciousness, breathing pattern and presence of a pulse. At the same time, the adequacy of cerebral oxygenation during CPR is critical for neurological outcome and thus survival. Cerebral oximetry, based on near-infrared spectroscopy (NIRS), provides a measure of brain oxygen saturation. Therefore, we examined the feasibility of using NIRS during CPR. Methods: Recent technologies (FORE-SIGHT™ and EQUANOX™) enable the monitoring of absolute cerebral tissue oxygen saturation (SctO2) values without the need for pre-calibration. We tested both FORE-SIGHT™ (five patients) and EQUANOX Advance™ (nine patients) technologies in the in-hospital as well as the out-of-hospital CPR setting. In this observational study, values were not utilized in any treatment protocol or therapeutic decision. An independent t-test was used for statistical analysis. Results: Our data demonstrate the feasibility of both technologies to measure cerebral oxygen saturation during CPR. With the continuous, pulseless near-infrared wave analysis of both FORE-SIGHT™ and EQUANOX™ technology, we obtained SctO2 values in the absence of spontaneous circulation. Both technologies were able to assess the efficacy of CPR efforts: improved resuscitation efforts (improved quality of chest compressions with switch of caregivers) resulted in higher SctO2 values. Until now, the ability of CPR to provide adequate tissue oxygenation was difficult to quantify or to assess clinically due to a lack of specific technology. With both technologies, any change in hemodynamics (for example, ventricular fibrillation) results in a reciprocal change in SctO2. In some patients, a sudden drop in SctO2 was the first warning sign of reoccurring ventricular fibrillation. Conclusions: Both the FORE-SIGHT™ and EQUANOX™ technology allow non-invasive monitoring of the cerebral oxygen saturation during CPR. Moreover, changes in SctO2 values might be used to monitor the efficacy of CPR efforts.
- 1 March 2013
- Published by Springer Nature in Critical Care
- Vol. 17 (2) , R36
Open AccessFeasibility of absolute cerebral tissue oxygen saturation during cardiopulmonary resuscitation
Introduction: Current monitoring during cardiopulmonary resuscitation (CPR) is limited to clinical observation of consciousness, breathing pattern and presence of a pulse. At the same time, the adequacy of cerebral oxygenation during CPR is critical for neurological outcome and thus survival. Cerebral oximetry, based on near-infrared spectroscopy (NIRS), provides a measure of brain oxygen saturation. Therefore, we examined the feasibility of using NIRS during CPR. Methods: Recent technologies (FORE-SIGHT™ and EQUANOX™) enable the monitoring of absolute cerebral tissue oxygen saturation (SctO2) values without the need for pre-calibration. We tested both FORE-SIGHT™ (five patients) and EQUANOX Advance™ (nine patients) technologies in the in-hospital as well as the out-of-hospital CPR setting. In this observational study, values were not utilized in any treatment protocol or therapeutic decision. An independent t-test was used for statistical analysis. Results: Our data demonstrate the feasibility of both technologies to measure cerebral oxygen saturation during CPR. With the continuous, pulseless near-infrared wave analysis of both FORE-SIGHT™ and EQUANOX™ technology, we obtained SctO2 values in the absence of spontaneous circulation. Both technologies were able to assess the efficacy of CPR efforts: improved resuscitation efforts (improved quality of chest compressions with switch of caregivers) resulted in higher SctO2 values. Until now, the ability of CPR to provide adequate tissue oxygenation was difficult to quantify or to assess clinically due to a lack of specific technology. With both technologies, any change in hemodynamics (for example, ventricular fibrillation) results in a reciprocal change in SctO2. In some patients, a sudden drop in SctO2 was the first warning sign of reoccurring ventricular fibrillation. Conclusions: Both the FORE-SIGHT™ and EQUANOX™ technology allow non-invasive monitoring of the cerebral oxygen saturation during CPR. Moreover, changes in SctO2 values might be used to monitor the efficacy of CPR efforts.