LGLaleh Golestanirad

Laleh Golestanirad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Laleh Golestanirad has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Giorgio Bonmassar

    Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts

    3 shared publications
  • Lawrence L. Wald

    Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts

    3 shared publications
  • Leonardo M. Angelone

    U.S. FDA, CDRH, Office of Science and Engineering Laboratories, Division of Biomedical Physics, Silver Spring, MD 20993 USA

    3 shared publications
  • Boris Keil

    Department of Life Science Engineering, Institute of Medical Physics and Radiation Protection, Giessen, Germany

    2 shared publications
  • Amir Ali Rahsepar

    Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois

    1 shared publication
  • Azma Mareyam

    Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA

    1 shared publication

Latest Publications

  • Open Access

    Changes in the specific absorption rate (SAR) of radiofrequency energy in patients with retained cardiac leads during MRI at 1.5T and 3T

    by Laleh Golestanirad, Amir Ali Rahsepar, John E Kirsch, Kenichiro Suwa, Jeremy C. Collins, Leonardo M. Angelone, Boris Keil, Rod S. Passman, Giorgio Bonmassar, Peter Serano, et al.

    Purpose: To evaluate the local specific absorption rate (SAR) and heating around retained cardiac leads during MRI at 64 MHz (1.5T) and 127 MHz (3T) as a function of RF coil type and imaging landmark.Methods: Numerical models of retained cardiac leads were built from CT and X‐ray images of 6 patients with retained cardiac leads. Electromagnetic simulations and bio‐heat modeling were performed with MRI RF body and head coils tuned to 64 MHz and 127 MHz and positioned at 9 different imaging landmarks covering an area from the head to the lower limbs.Results: For all patients and at both 1.5T and 3T, local transmit head coils produced negligible temperature rise ( ) for . For body imaging with quadrature‐driven coils at 1.5T, during a 10‐min scan remained < 3°C at all imaging landmarks for and <6°C for . For body imaging at 3T, during a 10‐min scan remained < 6°C at all imaging landmarks for . For shorter pulse sequences up to 2 min, remained < 6°C for .Conclusion: For the models based on 6 patients studied, simulations suggest that MRI could be performed safely using a local head coil at both 1.5T and 3T, and with a body coil at 1.5T with pulses that produced . MRI at 3T could be performed safely in these patients using pulses with .


  • Local SAR near deep brain stimulation (DBS) electrodes at 64 and 127 MHz: A simulation study of the effect of extracranial loops

    by Laleh Golestanirad, Leonardo M. Angelone, Maria Ida Iacono, Husam Katnani, Lawrence L. Wald, Giorgio Bonmassar

    Purpose: MRI may cause brain tissue around deep brain stimulation (DBS) electrodes to become excessively hot, causing lesions. The presence of extracranial loops in the DBS lead trajectory has been shown to affect the specific absorption rate (SAR) of the radiofrequency energy at the electrode tip, but experimental studies have reported controversial results. The goal of this study was to perform a systematic numerical study to provide a better understanding of the effects of extracranial loops in DBS leads on the local SAR during MRI at 64 and 127 MHz.Methods: A total of 160 numerical simulations were performed on patient‐derived data, in which relevant factors including lead length and trajectory, loop location and topology, and frequency of MRI radiofrequency (RF) transmitter were assessed.Results: Overall, the presence of extracranial loops reduced the local SAR in the tissue around the DBS tip compared with straight trajectories with the same length. SAR reduction was significantly larger at 127 MHz compared with 64 MHz. SAR reduction was significantly more sensitive to variable loop parameters (eg, topology and location) at 127 MHz compared with 64 MHz.Conclusion: Lead management strategies could exist that significantly reduce the risks of 3 Tesla (T) MRI for DBS patients. Magn Reson Med 78:1558–1565, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


  • Feasibility of using linearly polarized rotating birdcage transmitters and close-fitting receive arrays in MRI to reduce SAR in the vicinity of deep brain simulation implants

    by Laleh Golestanirad, Boris Keil, Leonardo M. Angelone, Giorgio Bonmassar, Azma Mareyam, Lawrence L. Wald

    Purpose MRI of patients with deep brain stimulation (DBS) implants is strictly limited due to safety concerns, including high levels of local specific absorption rate (SAR) of radiofrequency (RF) fields near the implant and related RF‐induced heating. This study demonstrates the feasibility of using a rotating linearly polarized birdcage transmitter and a 32‐channel close‐fit receive array to significantly reduce local SAR in MRI of DBS patients. Methods Electromagnetic simulations and phantom experiments were performed with generic DBS lead geometries and implantation paths. The technique was based on mechanically rotating a linear birdcage transmitter to align its zero electric‐field region with the implant while using a close‐fit receive array to significantly increase signal to noise ratio of the images. Results It was found that the zero electric‐field region of the transmitter is thick enough at 1.5 Tesla to encompass DBS lead trajectories with wire segments that were up to 30 degrees out of plane, as well as leads with looped segments. Moreover, SAR reduction was not sensitive to tissue properties, and insertion of a close‐fit 32‐channel receive array did not degrade the SAR reduction performance. Conclusion The ensemble of rotating linear birdcage and 32‐channel close‐fit receive array introduces a promising technology for future improvement of imaging in patients with DBS implants. Magn Reson Med 77:1701–1712, 2017. © 2016 International Society for Magnetic Resonance in Medicine


  • Open Access

    A preliminary fMRI study of a novel self-paced written fluency task: observation of left-hemispheric activation, and increased frontal activation in late vs. early task phases

    by Laleh Golestanirad, Sunit Das, Tom A. Schweizer, Simon J. Graham

    Neuropsychological tests of verbal fluency are very widely used to characterize impaired cognitive function. For clinical neuroscience studies and potential medical applications, measuring the brain activity that underlies such tests with functional magnetic resonance imaging (fMRI) is of significant interest - but a challenging proposition because overt speech can cause signal artifacts, which tend to worsen as the duration of speech tasks becomes longer. In a novel approach, we present the group brain activity of 12 subjects who performed a self-paced written version of phonemic fluency using fMRI-compatible tablet technology that recorded responses and provided task-related feedback on a projection screen display, over long-duration task blocks (60 s). As predicted, we observed robust activation in the left anterior inferior and medial frontal gyri, consisting with previously reported results of verbal fluency tasks which established the role of these areas in strategic word retrieval. In addition, the number of words produced in the late phase (last 30 s) of written phonemic fluency was significantly less (p < 0.05) than the number produced in the early phase (first 30 s). Activation during the late phase vs. the early phase was also assessed from the first 20 s and last 20 s of task performance, which eliminated the possibility that the sluggish hemodynamic response from the early phase would affect the activation estimates of the late phase. The last 20 s produced greater activation maps covering extended areas in bilateral precuneus, cuneus, middle temporal gyrus, insula, middle frontal gyrus and cingulate gyrus. Among them, greater activation was observed in the bilateral middle frontal gyrus (Brodmann area BA 9) and cingulate gyrus (BA 24, 32) likely as part of the initiation, maintenance, and shifting of attentional resources.