Pirkko-Liisa Kellokumpu-Lehtinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pirkko-Liisa Kellokumpu-Lehtinen has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Mika Kapanen
Department of Oncology, Tampere University Hospital, PO BOX 2000, FI-33521 Tampere, Finland; Department of Medical Physics, Tampere University Hospital, PO BOX 2000, FI-33521 Tampere, Finland
6 shared publications - Tanja Skyttä
Department of Oncology, Tampere University Hospital, PO BOX 2000, FI-33521 Tampere, Finland
6 shared publications - Marko Laaksomaa
Department of Oncology, Tampere University Hospital, Tampere, Finland
4 shared publications - Simo Hyödynmaa
Department of Medical Physics, Medical Imaging Center, Tampere University Hospital, P.O. Box 2000, FI-33521 Tampere, Finland
4 shared publications Pekka Raatikainen
Department of Medicine, Central Finland Health Care District and University of Eastern Finland, Jyväskylä, Finland
2 shared publications- Seppo Peltola
Department of Medical Physics, Tampere University Hospital (TAUH), PO BOX 2000, Teiskontie 35, FI-33521, Tampere, Finland.
2 shared publications
Latest Publications
- Open Access
- 25 January 2017
- Published by Springer Nature in BMC Palliative Care
- Vol. 16 (1) , 1-9
Undergraduate curriculum in palliative medicine at Tampere University increases students’ knowledge
Education in palliative medicine (PM) at medical schools reveals wide variation despite the increasing importance of palliative care. Many universities present poor description of the benefits and detailed content of the total curriculum in PM. Using the recommendations of European Association for Palliative Care (EAPC) as a reference, we evaluated the content and outcomes of the curriculum in PM at the University of Tampere, Finland. We searched for a PM curriculum by examining the teaching offered by every specialty and compared it to EAPC recommendations. Students’ knowledge was evaluated using a progress test over three consecutive years. We found 53.5 teaching hours addressing PM issues, which exceeds the recommendation of the EAPC. Basics, symptom management, ethics, and communication skills were well established, while education in psychosocial/spiritual aspects, teamwork and self-reflection failed to reach the recommendations. Out of the maximum of 4.0, the progress test mean scores in PM among the third, fourth, fifth and sixth year students were 0.1 (SD 0.71), 0.69 (SD 1.28), 1.38 (SD 1.46) and 2.53 (SD 1.26), respectively (p < 0.001). This growing knowledge was associated with the timely increase in teaching provided through the PM discipline. In addition, the students who completed the optional PM course achieved better mean scores (2.66; SD 1.27) than the others (1.33; SD 1.43) (p < 0.001). The curriculum in PM at the University of Tampere is integrated into the teaching of many disciplines and complied well with the EAPC recommendations. This education led to increasing knowledge in PM among medical students.
- 25 January 2017
- Published by Springer Nature in BMC Palliative Care
- Vol. 16 (1) , 1-9
Open AccessUndergraduate curriculum in palliative medicine at Tampere University increases students’ knowledge
Education in palliative medicine (PM) at medical schools reveals wide variation despite the increasing importance of palliative care. Many universities present poor description of the benefits and detailed content of the total curriculum in PM. Using the recommendations of European Association for Palliative Care (EAPC) as a reference, we evaluated the content and outcomes of the curriculum in PM at the University of Tampere, Finland. We searched for a PM curriculum by examining the teaching offered by every specialty and compared it to EAPC recommendations. Students’ knowledge was evaluated using a progress test over three consecutive years. We found 53.5 teaching hours addressing PM issues, which exceeds the recommendation of the EAPC. Basics, symptom management, ethics, and communication skills were well established, while education in psychosocial/spiritual aspects, teamwork and self-reflection failed to reach the recommendations. Out of the maximum of 4.0, the progress test mean scores in PM among the third, fourth, fifth and sixth year students were 0.1 (SD 0.71), 0.69 (SD 1.28), 1.38 (SD 1.46) and 2.53 (SD 1.26), respectively (p < 0.001). This growing knowledge was associated with the timely increase in teaching provided through the PM discipline. In addition, the students who completed the optional PM course achieved better mean scores (2.66; SD 1.27) than the others (1.33; SD 1.43) (p < 0.001). The curriculum in PM at the University of Tampere is integrated into the teaching of many disciplines and complied well with the EAPC recommendations. This education led to increasing knowledge in PM among medical students.
- Open Access
- 24 May 2016
- Published by Springer Nature in Breast Cancer Research and Treatment
- Vol. 157 (3) , 437-446
Biological subtyping of early breast cancer: a study comparing RT-qPCR with immunohistochemistry
The biological subtype of breast cancer influences the selection of systemic therapy. Distinction between luminal A and B cancers depends on consistent assessment of Ki-67, but substantial intra-observer and inter-observer variability exists when immunohistochemistry (IHC) is used. We compared RT-qPCR with IHC in the assessment of Ki-67 and other standard factors used in breast cancer subtyping. RNA was extracted from archival breast tumour tissue of 769 women randomly assigned to the FinHer trial. Cancer ESR1, PGR, ERBB2 and MKI67 mRNA content was quantitated with an RT-qPCR assay. Local pathologists assessed ER, PgR and Ki-67 expression using IHC. HER2 amplification was identified with chromogenic in situ hybridization (CISH) centrally. The results were correlated with distant disease-free survival (DDFS) and overall survival (OS). qPCR-based and IHC-based assessments of ER and PgR showed good concordance. Both low tumour MKI67 mRNA (RT-qPCR) and Ki-67 protein (IHC) levels were prognostic for favourable DDFS [hazard ratio (HR) 0.42, 95 % CI 0.25–0.71, P = 0.001; and HR 0.56, 0.37–0.84, P = 0.005, respectively] and OS. In multivariable analyses, cancer MKI67 mRNA content had independent influence on DDFS (adjusted HR 0.51, 95 % CI 0.29–0.89, P = 0.019) while Ki-67 protein expression had not any influence (P = 0.266) whereas both assessments influenced independently OS. Luminal B patients treated with docetaxel-FEC had more favourable DDFS and OS than those treated with vinorelbine-FEC when the subtype was defined by RT-qPCR (for DDFS, HR 0.52, 95 % CI 0.29–0.94, P = 0.031), but not when defined using IHC. Breast cancer subtypes approximated with RT-qPCR and IHC show good concordance, but cancer MKI67 mRNA content correlated slightly better with DDFS than Ki-67 expression. The findings based on MKI67 mRNA content suggest that patients with luminal B cancer benefit more from docetaxel-FEC than from vinorelbine-FEC.
- 24 May 2016
- Published by Springer Nature in Breast Cancer Research and Treatment
- Vol. 157 (3) , 437-446
Open AccessBiological subtyping of early breast cancer: a study comparing RT-qPCR with immunohistochemistry
The biological subtype of breast cancer influences the selection of systemic therapy. Distinction between luminal A and B cancers depends on consistent assessment of Ki-67, but substantial intra-observer and inter-observer variability exists when immunohistochemistry (IHC) is used. We compared RT-qPCR with IHC in the assessment of Ki-67 and other standard factors used in breast cancer subtyping. RNA was extracted from archival breast tumour tissue of 769 women randomly assigned to the FinHer trial. Cancer ESR1, PGR, ERBB2 and MKI67 mRNA content was quantitated with an RT-qPCR assay. Local pathologists assessed ER, PgR and Ki-67 expression using IHC. HER2 amplification was identified with chromogenic in situ hybridization (CISH) centrally. The results were correlated with distant disease-free survival (DDFS) and overall survival (OS). qPCR-based and IHC-based assessments of ER and PgR showed good concordance. Both low tumour MKI67 mRNA (RT-qPCR) and Ki-67 protein (IHC) levels were prognostic for favourable DDFS [hazard ratio (HR) 0.42, 95 % CI 0.25–0.71, P = 0.001; and HR 0.56, 0.37–0.84, P = 0.005, respectively] and OS. In multivariable analyses, cancer MKI67 mRNA content had independent influence on DDFS (adjusted HR 0.51, 95 % CI 0.29–0.89, P = 0.019) while Ki-67 protein expression had not any influence (P = 0.266) whereas both assessments influenced independently OS. Luminal B patients treated with docetaxel-FEC had more favourable DDFS and OS than those treated with vinorelbine-FEC when the subtype was defined by RT-qPCR (for DDFS, HR 0.52, 95 % CI 0.29–0.94, P = 0.031), but not when defined using IHC. Breast cancer subtypes approximated with RT-qPCR and IHC show good concordance, but cancer MKI67 mRNA content correlated slightly better with DDFS than Ki-67 expression. The findings based on MKI67 mRNA content suggest that patients with luminal B cancer benefit more from docetaxel-FEC than from vinorelbine-FEC.
- 1 February 2016
- Vol. 36 (2) , 555-63
Restoring Natural Killer Cell Cytotoxicity After Hyperthermia Alone or Combined with Radiotherapy.
The aim of the present study was to investigate in vitro the effect of hypo- and hyperthermia alone or in combination with irradiation on natural killer cell (NK) cytotoxicity, recovery of this function and the possibility of preventing damage to or enhancing cytotoxicity recovery using interferons (IFNs) α, β, and γ and interleukin-2 (IL-2). We used non-selected NK cells and measured their cytotoxicity using the (51)Cr release assay. Temperatures ranging from 31-45°C and thermal treatment times from 0-180 min were assessed. IFNs were applied at concentrations from 0-1,000 IU/ml and IL-2 from 0-450 IU/ml. The range of irradiation dose was from 0-30 Gy. We detected no significant differences in cytotoxicity at temperatures from 31-37°C. The most significant decrease in cytotoxicity was observed between 41 and 42°C (p=0.0010), and heating NK cells at 42°C for 180 min almost completely abolished this function. NK cell cytotoxicity largely recovered during the first 24 h, depending on the heating time. IFN-α, β, and γ demonstrated no concentration-dependent ability to aid in recovery when used before or after the thermal treatment. In contrast, IL-2 restored cytotoxicity in a concentration- and incubation time-dependent manner and was equally active when used before, during or after heating. NK cells were heated at 42°C for various times and then irradiated with a single dose or first irradiated and then heated; however, no statistically significant differences were observed (p=0.520). An approach of IL-2 treatment followed by radiation and heating was the most effective in restoring NK cytotoxicity (p=0.000). NK cell cytotoxicity is impaired in vitro at 42°C and above, with possible partial recovery. IL-2, but not IFNs, was able to restore NK cell cytotoxicity in a concentration-dependent manner. IL-2 can also reverse the damage caused by combined hyperthermia and irradiation.
- 1 February 2016
- Vol. 36 (2) , 555-63
Restoring Natural Killer Cell Cytotoxicity After Hyperthermia Alone or Combined with Radiotherapy.
The aim of the present study was to investigate in vitro the effect of hypo- and hyperthermia alone or in combination with irradiation on natural killer cell (NK) cytotoxicity, recovery of this function and the possibility of preventing damage to or enhancing cytotoxicity recovery using interferons (IFNs) α, β, and γ and interleukin-2 (IL-2). We used non-selected NK cells and measured their cytotoxicity using the (51)Cr release assay. Temperatures ranging from 31-45°C and thermal treatment times from 0-180 min were assessed. IFNs were applied at concentrations from 0-1,000 IU/ml and IL-2 from 0-450 IU/ml. The range of irradiation dose was from 0-30 Gy. We detected no significant differences in cytotoxicity at temperatures from 31-37°C. The most significant decrease in cytotoxicity was observed between 41 and 42°C (p=0.0010), and heating NK cells at 42°C for 180 min almost completely abolished this function. NK cell cytotoxicity largely recovered during the first 24 h, depending on the heating time. IFN-α, β, and γ demonstrated no concentration-dependent ability to aid in recovery when used before or after the thermal treatment. In contrast, IL-2 restored cytotoxicity in a concentration- and incubation time-dependent manner and was equally active when used before, during or after heating. NK cells were heated at 42°C for various times and then irradiated with a single dose or first irradiated and then heated; however, no statistically significant differences were observed (p=0.520). An approach of IL-2 treatment followed by radiation and heating was the most effective in restoring NK cytotoxicity (p=0.000). NK cell cytotoxicity is impaired in vitro at 42°C and above, with possible partial recovery. IL-2, but not IFNs, was able to restore NK cell cytotoxicity in a concentration-dependent manner. IL-2 can also reverse the damage caused by combined hyperthermia and irradiation.
- 1 October 2015
- Vol. 35 (10) , 5193-200
Effects of Single and Fractionated Irradiation on Natural Killer Cell Populations: Radiobiological Characteristics of Viability and Cytotoxicity In Vitro.
Natural killer (NK) cells are important in destroying tumor cells. However, they are damaged by radiation therapy. We studied the effects of single and fractionated irradiation on the viability and cytotoxicity of human non-selected NK cells and sub-groups with cluster of differentiation (CD) CD16(+) and CD56(+) in vitro. Only very few studies dealing with the standard radiobiological parameters for characterizing NK cells exist in the literature. NK cell populations were isolated from buffy coats using different methods and irradiated with single doses up to 80 Gy and fractionated doses of 10 or 30 Gy with different numbers of applications and at different intervals. The study end-points were viability using propidium iodide (PI), trypan blue and intracellular adenosine triphosphate (ATP) assays, and cytotoxicity using the (51)Cr-release assay. The standard radiobiological parameters α and β of the linear-quadratic (L-Q) model and the mean inactivation dose D̅ taken as the area under the curve (AUC) were calculated to characterize the radiosensitivity of different NK cell populations. The AUC values of the 51Cr release data in the dose range of 0-40 Gy were as follows: for non-selected NK cells, 23.6-20.9 Gy; for CD16(+) and CD56(+) cells, 14.5-13.2 Gy. The AUC values of ATP, trypan blue and propidium iodide methods equally well described the viability of irradiated NK cells. The α/β ratio for cytotoxicity and viability data in the L-Q model corresponded to the acutely responding tissues. Splitting a 30-Gy dose into two fractions applied at different intervals caused a significant rise in ATP levels and cytotoxicity. Dividing the total dose into four doses applied at fixed intervals also resulted in significant elevations of ATP content and cytotoxicity of NK cells at 10 Gy. According to the L-Q method, irradiated NK cells behaved similarly to acutely responding human tissues with respect to cytotoxicity and viability. The AUC proved very useful for comparing the effects of irradiation on NK cells.
- 1 October 2015
- Vol. 35 (10) , 5193-200
Effects of Single and Fractionated Irradiation on Natural Killer Cell Populations: Radiobiological Characteristics of Viability and Cytotoxicity In Vitro.
Natural killer (NK) cells are important in destroying tumor cells. However, they are damaged by radiation therapy. We studied the effects of single and fractionated irradiation on the viability and cytotoxicity of human non-selected NK cells and sub-groups with cluster of differentiation (CD) CD16(+) and CD56(+) in vitro. Only very few studies dealing with the standard radiobiological parameters for characterizing NK cells exist in the literature. NK cell populations were isolated from buffy coats using different methods and irradiated with single doses up to 80 Gy and fractionated doses of 10 or 30 Gy with different numbers of applications and at different intervals. The study end-points were viability using propidium iodide (PI), trypan blue and intracellular adenosine triphosphate (ATP) assays, and cytotoxicity using the (51)Cr-release assay. The standard radiobiological parameters α and β of the linear-quadratic (L-Q) model and the mean inactivation dose D̅ taken as the area under the curve (AUC) were calculated to characterize the radiosensitivity of different NK cell populations. The AUC values of the 51Cr release data in the dose range of 0-40 Gy were as follows: for non-selected NK cells, 23.6-20.9 Gy; for CD16(+) and CD56(+) cells, 14.5-13.2 Gy. The AUC values of ATP, trypan blue and propidium iodide methods equally well described the viability of irradiated NK cells. The α/β ratio for cytotoxicity and viability data in the L-Q model corresponded to the acutely responding tissues. Splitting a 30-Gy dose into two fractions applied at different intervals caused a significant rise in ATP levels and cytotoxicity. Dividing the total dose into four doses applied at fixed intervals also resulted in significant elevations of ATP content and cytotoxicity of NK cells at 10 Gy. According to the L-Q method, irradiated NK cells behaved similarly to acutely responding human tissues with respect to cytotoxicity and viability. The AUC proved very useful for comparing the effects of irradiation on NK cells.
- 1 July 2015
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 20 (4) , 292-298
Effects of remedies made in patient setup process on residual setup errors and margins in head and neck cancer radiotherapy based on 2D image guidance
Patient setup errors were aimed to be reduced in radiotherapy (RT) of head-and-neck (H&N) cancer. Some remedies in patient setup procedure were proposed for this purpose. RT of H&N cancer has challenges due to patient rotation and flexible anatomy. Residual position errors occurring in treatment situation and required setup margins were estimated for relevant bony landmarks after the remedies made in setup process and compared with previous results. The formation process for thermoplastic masks was improved. Also image matching was harmonized to the vertebrae in the middle of the target and a 5 mm threshold was introduced for immediate correction of systematic errors of the landmarks. After the remedies, residual position errors of bony landmarks were retrospectively determined from 748 orthogonal X-ray images of 40 H&N cancer patients. The landmarks were the vertebrae C1-2, C5-7, the occiput bone and the mandible. The errors include contributions from patient rotation, flexible anatomy and inter-observer variation in image matching. Setup margins (3D) were calculated with the Van Herk formula. Systematic residual errors of the landmarks were reduced maximally by 49.8% (p ≤ 0.05) and the margins by 3.1 mm after the remedies. With daily image guidance the setup margins of the landmarks were within 4.4 mm, but larger margins of 6.4 mm were required for the mandible. Remarkable decrease in the residual errors of the bony landmarks and setup margins were achieved through the remedies made in the setup process. The importance of quality assurance of the setup process was demonstrated.
- 1 July 2015
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 20 (4) , 292-298
Effects of remedies made in patient setup process on residual setup errors and margins in head and neck cancer radiotherapy based on 2D image guidance
Patient setup errors were aimed to be reduced in radiotherapy (RT) of head-and-neck (H&N) cancer. Some remedies in patient setup procedure were proposed for this purpose. RT of H&N cancer has challenges due to patient rotation and flexible anatomy. Residual position errors occurring in treatment situation and required setup margins were estimated for relevant bony landmarks after the remedies made in setup process and compared with previous results. The formation process for thermoplastic masks was improved. Also image matching was harmonized to the vertebrae in the middle of the target and a 5 mm threshold was introduced for immediate correction of systematic errors of the landmarks. After the remedies, residual position errors of bony landmarks were retrospectively determined from 748 orthogonal X-ray images of 40 H&N cancer patients. The landmarks were the vertebrae C1-2, C5-7, the occiput bone and the mandible. The errors include contributions from patient rotation, flexible anatomy and inter-observer variation in image matching. Setup margins (3D) were calculated with the Van Herk formula. Systematic residual errors of the landmarks were reduced maximally by 49.8% (p ≤ 0.05) and the margins by 3.1 mm after the remedies. With daily image guidance the setup margins of the landmarks were within 4.4 mm, but larger margins of 6.4 mm were required for the mandible. Remarkable decrease in the residual errors of the bony landmarks and setup margins were achieved through the remedies made in the setup process. The importance of quality assurance of the setup process was demonstrated.
- Open Access
- 3 April 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 76
Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold
Adjuvant radiotherapy (RT) of left-sided breast cancer is increasingly performed in voluntary deep inspiration breath-hold (vDIBH). The aim of this study was to estimate the reproducibility of breath-hold level (BHL) and to find optimal bony landmarks for matching of orthogonal setup images to minimise setup margins. 1067 sets of images with an orthogonal setup and tangential field from 67 patients were retrospectively analysed. Residual position errors were determined in the tangential treatment field images for different matches of the setup images. Variation of patient posture and BHL were analysed for position errors of the vertebrae, clavicula, ribs and sternum in the setup and tangential field images. The BHL was controlled with a Varian RPM® system. Setup margins were calculated using the van Herk’s formula. Patients who underwent lymph node irradiation were also investigated. For the breast alone, the midway compromise of the ribs and sternum was the best general choice for matching of the setup images. The required margins were 6.5 mm and 5.3 mm in superior-inferior (SI) and lateral/anterior-posterior (LAT/AP) directions, respectively. With the individually optimised image matching position also including the vertebrae, slightly smaller margins of 6.0 mm and 4.8 mm were achieved, respectively. With the individually optimised match, margins of 7.5 mm and 10.8 mm should be used in LAT and SI directions, respectively, for the lymph node regions. These margins were considered too large. The reproducibility of the BHL was within 5 mm in the AP direction for 75% of patients. The smallest setup margins were obtained when the matching position of the setup images was individually optimised for each patient. Optimal match for the breast alone is not optimal for the lymph node region, and, therefore, a threshold of 5 mm was introduced for residual position errors of the sternum, upper vertebrae, clavicula and chest wall to retain minimal setup margins of 5 mm. Because random interfraction variation in patient posture was large, we recommend daily online image guidance. The BHL should be verified with image guidance.
- 3 April 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 76
Open AccessDetermination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold
Adjuvant radiotherapy (RT) of left-sided breast cancer is increasingly performed in voluntary deep inspiration breath-hold (vDIBH). The aim of this study was to estimate the reproducibility of breath-hold level (BHL) and to find optimal bony landmarks for matching of orthogonal setup images to minimise setup margins. 1067 sets of images with an orthogonal setup and tangential field from 67 patients were retrospectively analysed. Residual position errors were determined in the tangential treatment field images for different matches of the setup images. Variation of patient posture and BHL were analysed for position errors of the vertebrae, clavicula, ribs and sternum in the setup and tangential field images. The BHL was controlled with a Varian RPM® system. Setup margins were calculated using the van Herk’s formula. Patients who underwent lymph node irradiation were also investigated. For the breast alone, the midway compromise of the ribs and sternum was the best general choice for matching of the setup images. The required margins were 6.5 mm and 5.3 mm in superior-inferior (SI) and lateral/anterior-posterior (LAT/AP) directions, respectively. With the individually optimised image matching position also including the vertebrae, slightly smaller margins of 6.0 mm and 4.8 mm were achieved, respectively. With the individually optimised match, margins of 7.5 mm and 10.8 mm should be used in LAT and SI directions, respectively, for the lymph node regions. These margins were considered too large. The reproducibility of the BHL was within 5 mm in the AP direction for 75% of patients. The smallest setup margins were obtained when the matching position of the setup images was individually optimised for each patient. Optimal match for the breast alone is not optimal for the lymph node region, and, therefore, a threshold of 5 mm was introduced for residual position errors of the sternum, upper vertebrae, clavicula and chest wall to retain minimal setup margins of 5 mm. Because random interfraction variation in patient posture was large, we recommend daily online image guidance. The BHL should be verified with image guidance.
- 1 April 2015
- Vol. 35 (4) , 2141-7
Early effects of adjuvant breast cancer radiotherapy on right ventricular systolic and diastolic function.
Reduced right ventricular (RV) systolic function correlates with poor prognosis in several heart diseases. The aim of this prospective single-Center study was to investigate whether conformal three-dimensional (3D) breast cancer radiotherapy impairs RV function. Forty-nine patients with early-stage left-sided breast cancer underwent comprehensive two-dimensional (2D) echocardiography before and after radiotherapy. RV function was evaluated with tricuspid annular plane systolic excursion (TAPSE), pulsed tissue Doppler peak velocity at the lateral RV wall (S') and RV and venous flow analysis. Radiotherapy reduced TAPSE from 24.5 ± 4.0 mm to 22.4 ± 3.9 mm (p<0.001), S' from 12.7 ± 3.1 m/s to 12.2 ± 2.7 m/s (p=0.11) and pulmonary flow velocity time integral (VTI) from 16.6 ± 3.1 cm to 15.9 ± 2.3 cm (p=0.07), respectively. These changes were unrelated to changes in LV function. Modern radiotherapy reduced RV systolic function. As a readily-available and sensitive measurement, TAPSE is as a practical tool for detection of radiotherapy-induced cardiac changes.
- 1 April 2015
- Vol. 35 (4) , 2141-7
Early effects of adjuvant breast cancer radiotherapy on right ventricular systolic and diastolic function.
Reduced right ventricular (RV) systolic function correlates with poor prognosis in several heart diseases. The aim of this prospective single-Center study was to investigate whether conformal three-dimensional (3D) breast cancer radiotherapy impairs RV function. Forty-nine patients with early-stage left-sided breast cancer underwent comprehensive two-dimensional (2D) echocardiography before and after radiotherapy. RV function was evaluated with tricuspid annular plane systolic excursion (TAPSE), pulsed tissue Doppler peak velocity at the lateral RV wall (S') and RV and venous flow analysis. Radiotherapy reduced TAPSE from 24.5 ± 4.0 mm to 22.4 ± 3.9 mm (p<0.001), S' from 12.7 ± 3.1 m/s to 12.2 ± 2.7 m/s (p=0.11) and pulmonary flow velocity time integral (VTI) from 16.6 ± 3.1 cm to 15.9 ± 2.3 cm (p=0.07), respectively. These changes were unrelated to changes in LV function. Modern radiotherapy reduced RV systolic function. As a readily-available and sensitive measurement, TAPSE is as a practical tool for detection of radiotherapy-induced cardiac changes.
- 1 March 2015
- Vol. 35 (3) , 1559-66
The concurrent use of aromatase inhibitors and radiotherapy induces echocardiographic changes in patients with breast cancer.
Adjuvant radiotherapy (RT) for left-sided breast cancer has a negative impact on cardiac health. The concurrent use of aromatase inhibitors (AIs) during RT was found to increase the anticancer efficacy of radiation in pre-clinical models. We evaluated whether the acute effects of RT on cardiac functions are augmented by the concurrent use of AIs. Sixty patients with early-stage left-sided breast cancer underwent a 2D echocardiography, electrocardiogram and cardiac biomarker measurements before and after adjuvant breast RT. Data were analyzed in two groups according to AI use. We observed a significant (p<0.05) decrease in right ventricular systolic function during RT in tricuspid annular plane systolic excursion (TAPSE). TAPSE decreased by 3.0 mm [95% confidence interval (CI)=1.9-4.1 mm] in the AI group and 1.4 mm (95% CI=0.3-2.4 mm) in the non-AI group. In addition, left ventricular diastolic function decreased among patients using AI, as the mitral inflow E-wave decreased 5.8 cm/s (95% CI=1.8-9.7 cm/s) (p=0.006). The concurrent use of AI during RT for left-sided breast cancer led to a more pronounced change on right ventricular systolic function and left ventricular diastolic functions compared to RT alone.
- 1 March 2015
- Vol. 35 (3) , 1559-66
The concurrent use of aromatase inhibitors and radiotherapy induces echocardiographic changes in patients with breast cancer.
Adjuvant radiotherapy (RT) for left-sided breast cancer has a negative impact on cardiac health. The concurrent use of aromatase inhibitors (AIs) during RT was found to increase the anticancer efficacy of radiation in pre-clinical models. We evaluated whether the acute effects of RT on cardiac functions are augmented by the concurrent use of AIs. Sixty patients with early-stage left-sided breast cancer underwent a 2D echocardiography, electrocardiogram and cardiac biomarker measurements before and after adjuvant breast RT. Data were analyzed in two groups according to AI use. We observed a significant (p<0.05) decrease in right ventricular systolic function during RT in tricuspid annular plane systolic excursion (TAPSE). TAPSE decreased by 3.0 mm [95% confidence interval (CI)=1.9-4.1 mm] in the AI group and 1.4 mm (95% CI=0.3-2.4 mm) in the non-AI group. In addition, left ventricular diastolic function decreased among patients using AI, as the mitral inflow E-wave decreased 5.8 cm/s (95% CI=1.8-9.7 cm/s) (p=0.006). The concurrent use of AI during RT for left-sided breast cancer led to a more pronounced change on right ventricular systolic function and left ventricular diastolic functions compared to RT alone.
- 1 January 2015
- Vol. 131 (5) , 433-40
[Cardiac effects of radiation therapy].
Because of increased life-expentancy cancer patients having undergone radiation therapy nowadays live longer, and late-appearing adverse effects are therefore playing a more significant role. Radiation therapy given to the chest is known to approximately double the risk of heart disease, the cumulative total radiation dose being the most important risk-increasing factor. The most significant adverse effects appear only years after the treatment. The mortality from late manifestations reduces the total benefit of radiation therapy. Patients with radiation therapy due to a cancer of the left breast or Hodgkin's lymphoma are particularly susceptible to cardiac effects. A safe radiation dose is not known.
- 1 January 2015
- Vol. 131 (5) , 433-40
[Cardiac effects of radiation therapy].
Because of increased life-expentancy cancer patients having undergone radiation therapy nowadays live longer, and late-appearing adverse effects are therefore playing a more significant role. Radiation therapy given to the chest is known to approximately double the risk of heart disease, the cumulative total radiation dose being the most important risk-increasing factor. The most significant adverse effects appear only years after the treatment. The mortality from late manifestations reduces the total benefit of radiation therapy. Patients with radiation therapy due to a cancer of the left breast or Hodgkin's lymphoma are particularly susceptible to cardiac effects. A safe radiation dose is not known.
- 1 November 2014
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 19 (6) , 369-375
Estimation of optimal matching position for orthogonal kV setup images and minimal setup margins in radiotherapy of whole breast and lymph node areas
The aim was to find an optimal setup image matching position and minimal setup margins to maximally spare the organs at risk in breast radiotherapy. Radiotherapy of breast cancer is a routine task but has many challenges. We investigated residual position errors in whole breast radiotherapy when orthogonal setup images were matched to different bony landmarks. A total of 1111 orthogonal setup image pairs and tangential field images were analyzed retrospectively for 50 consecutive patients. Residual errors in the treatment field images were determined by matching the orthogonal setup images to the vertebrae, sternum, ribs and their compromises. The most important region was the chest wall as it is crucial for the dose delivered to the heart and the ipsilateral lung. Inter-observer variation in online image matching was investigated. The best general image matching position was the compromise of the vertebrae, ribs and sternum, while the worst position was the vertebrae alone (p ≤ 0.03). The setup margins required for the chest wall varied from 4.3 mm to 5.5 mm in the lung direction while in the superior-inferior (SI) direction the margins varied from 5.1 mm to 7.6 mm. The inter-observer variation increased the minimal margins by approximately 1 mm. The margin of the lymph node areas should be at least 4.8 mm. Setup margins can be reduced by proper selection of a matching position for the orthogonal setup images. To retain the minimal margins sufficient, systematic error of the chest wall should not exceed 4 mm in the tangential field image.
- 1 November 2014
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 19 (6) , 369-375
Estimation of optimal matching position for orthogonal kV setup images and minimal setup margins in radiotherapy of whole breast and lymph node areas
The aim was to find an optimal setup image matching position and minimal setup margins to maximally spare the organs at risk in breast radiotherapy. Radiotherapy of breast cancer is a routine task but has many challenges. We investigated residual position errors in whole breast radiotherapy when orthogonal setup images were matched to different bony landmarks. A total of 1111 orthogonal setup image pairs and tangential field images were analyzed retrospectively for 50 consecutive patients. Residual errors in the treatment field images were determined by matching the orthogonal setup images to the vertebrae, sternum, ribs and their compromises. The most important region was the chest wall as it is crucial for the dose delivered to the heart and the ipsilateral lung. Inter-observer variation in online image matching was investigated. The best general image matching position was the compromise of the vertebrae, ribs and sternum, while the worst position was the vertebrae alone (p ≤ 0.03). The setup margins required for the chest wall varied from 4.3 mm to 5.5 mm in the lung direction while in the superior-inferior (SI) direction the margins varied from 5.1 mm to 7.6 mm. The inter-observer variation increased the minimal margins by approximately 1 mm. The margin of the lymph node areas should be at least 4.8 mm. Setup margins can be reduced by proper selection of a matching position for the orthogonal setup images. To retain the minimal margins sufficient, systematic error of the chest wall should not exceed 4 mm in the tangential field image.