Buntaro Fujita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Buntaro Fujita has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Jan Gummert
Department for Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Ruhr-University Bochum, Bad Oeynhausen, Germany
4 shared publicationsJochen Börgermann
Department for Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Ruhr-University Bochum, Bad Oeynhausen, Germany
4 shared publicationsSmita Scholtz
4 shared publicationsMaximilian Kütting
Institute of Applied Medical Engineering, Helmholtz-Institute RWTH Aachen University, Aachen, Germany
3 shared publicationsStephan Ensminger
Department of Thoracic and Cardiovascular Surgery, Heart and Diabetes Center NRW, Ruhr-University Bochum, Bad Oeynhausen, Germany
3 shared publicationsUlrich Steinseifer
Institute of Applied Medical Engineering, Helmholtz-Institute RWTH Aachen University, Aachen, Germany
3 shared publications
Latest Publications
- Open Access
- 27 November 2017
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 53 (3) , 552-559
Trends in practice and outcomes from 2011 to 2015 for surgical aortic valve replacement: an update from the German Aortic Valve Registry on 42 776 patients
Surgical aortic valve replacement (sAVR) is coming under close scrutiny with the recent upswing in the use of less invasive approaches. The aim of this analysis was to identify current trends in patient selection, procedural characteristics and outcomes after sAVR in Germany. We analysed data from 42 776 patients included in the German Aortic Valve Registry who underwent sAVR with and without coronary artery bypass surgery (CABG) between 2011 and 2015. Baseline, procedural and short-term outcome parameters were analysed. Of all registered patients, 26 618 (62.2%) underwent isolated sAVR and 16 158 (37.8%) sAVR + CABG. The median age was 72 years, and the median Society of Thoracic Surgeons Predicted Risk of Mortality (STS PROM) was 2.3%. From 2011 to 2015, there was a decline in STS PROM (2.4–2.2%, P < 0.001) and a decline in risk factors, such as pulmonary hypertension (9.1–3.2%, P < 0.001), occlusive arterial disease (19.6–17.7%, P = 0.003), mitral regurgitation ≥2° (10.6–7.6%, P < 0.001) and New York Heart Association Class III/IV (65.3–59.2%, P < 0.001). In-hospital mortality was 2.3%, 1.3% had disabling stroke, 0.4% residual aortic regurgitation ≥2°, and the incidence of new-onset pacemaker/implantable cardioverter–defibrillator implantation was 3.9%. There was an increase in the use of biological valves in patients P < 0.001), and the proportion of rapid deployment valves increased significantly (1.5–8.4%, P < 0.001) over the investigated time period. Both isolated sAVR as well as sAVR + CABG resulted in excellent in-hospital outcomes based on >42 000 patients treated between 2011 and 2015. The implementation of alternative treatment strategies has resulted in palpable changes in patient and device selection.
- 27 November 2017
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 53 (3) , 552-559
Open AccessTrends in practice and outcomes from 2011 to 2015 for surgical aortic valve replacement: an update from the German Aortic Valve Registry on 42 776 patients
Surgical aortic valve replacement (sAVR) is coming under close scrutiny with the recent upswing in the use of less invasive approaches. The aim of this analysis was to identify current trends in patient selection, procedural characteristics and outcomes after sAVR in Germany. We analysed data from 42 776 patients included in the German Aortic Valve Registry who underwent sAVR with and without coronary artery bypass surgery (CABG) between 2011 and 2015. Baseline, procedural and short-term outcome parameters were analysed. Of all registered patients, 26 618 (62.2%) underwent isolated sAVR and 16 158 (37.8%) sAVR + CABG. The median age was 72 years, and the median Society of Thoracic Surgeons Predicted Risk of Mortality (STS PROM) was 2.3%. From 2011 to 2015, there was a decline in STS PROM (2.4–2.2%, P < 0.001) and a decline in risk factors, such as pulmonary hypertension (9.1–3.2%, P < 0.001), occlusive arterial disease (19.6–17.7%, P = 0.003), mitral regurgitation ≥2° (10.6–7.6%, P < 0.001) and New York Heart Association Class III/IV (65.3–59.2%, P < 0.001). In-hospital mortality was 2.3%, 1.3% had disabling stroke, 0.4% residual aortic regurgitation ≥2°, and the incidence of new-onset pacemaker/implantable cardioverter–defibrillator implantation was 3.9%. There was an increase in the use of biological valves in patients P < 0.001), and the proportion of rapid deployment valves increased significantly (1.5–8.4%, P < 0.001) over the investigated time period. Both isolated sAVR as well as sAVR + CABG resulted in excellent in-hospital outcomes based on >42 000 patients treated between 2011 and 2015. The implementation of alternative treatment strategies has resulted in palpable changes in patient and device selection.
- Open Access
- 20 January 2017
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 24 (4) , 506-513
Dual source computed tomography based analysis of stent performance, its association with valvular calcification and residual aortic regurgitation after implantation of a balloon-expandable transcatheter heart valve
OBJECTIVES: The aim of this study was to investigate the mutual influence of valvular calcifications and transcatheter aortic valve stent geometry during and after implantation of a balloon-expandable SAPIEN®/SAPIEN XT® prostheses. Aortic valve calcification has been linked with adverse complications after transcatheter aortic valve implantation (TAVI). However, little is known about the fate of the calcifications after TAVI as well as its influence on transcatheter heart valve geometry. METHODS: Thirty one patients underwent cardiac dual source computed tomography (DSCT) before and after a TAVI with the Edwards SAPIEN/SAPIEN XT® prostheses. Detailed DSCT image analysis was performed with Mimics® and 3Matic® (both Materialise, Leuven, Belgium). RESULTS: Implanted stents reached an average degree of expansion of 84% and achieved good circularity despite the presence of fairly oval native annuli and a heterogeneous degree of valvular calcification. Both, the degree of stent expansion and the degree of stent eccentricity were inversely related to the degree of oversizing, but independent of the degree of valvular calcification and native annular ovality. Visualization of the position of calcific debris before and after TAVI showed that calcifications were shifted upwards and outwards as a consequence of the implantation procedure. The degree of stent eccentricity was related to residual aortic regurgitation grade ≥2. CONCLUSIONS: The SAPIEN®/SAPIEN XT® prostheses achieved good degrees of stent expansion and circularity regardless of the morphology of the landing zone. Increased stent ovality was associated with an elevated risk for aortic regurgitation. The total calcification volume, degree of annular ovality and stent expansion were not associated with residual AR.
- 20 January 2017
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 24 (4) , 506-513
Open AccessDual source computed tomography based analysis of stent performance, its association with valvular calcification and residual aortic regurgitation after implantation of a balloon-expandable transcatheter heart valve
OBJECTIVES: The aim of this study was to investigate the mutual influence of valvular calcifications and transcatheter aortic valve stent geometry during and after implantation of a balloon-expandable SAPIEN®/SAPIEN XT® prostheses. Aortic valve calcification has been linked with adverse complications after transcatheter aortic valve implantation (TAVI). However, little is known about the fate of the calcifications after TAVI as well as its influence on transcatheter heart valve geometry. METHODS: Thirty one patients underwent cardiac dual source computed tomography (DSCT) before and after a TAVI with the Edwards SAPIEN/SAPIEN XT® prostheses. Detailed DSCT image analysis was performed with Mimics® and 3Matic® (both Materialise, Leuven, Belgium). RESULTS: Implanted stents reached an average degree of expansion of 84% and achieved good circularity despite the presence of fairly oval native annuli and a heterogeneous degree of valvular calcification. Both, the degree of stent expansion and the degree of stent eccentricity were inversely related to the degree of oversizing, but independent of the degree of valvular calcification and native annular ovality. Visualization of the position of calcific debris before and after TAVI showed that calcifications were shifted upwards and outwards as a consequence of the implantation procedure. The degree of stent eccentricity was related to residual aortic regurgitation grade ≥2. CONCLUSIONS: The SAPIEN®/SAPIEN XT® prostheses achieved good degrees of stent expansion and circularity regardless of the morphology of the landing zone. Increased stent ovality was associated with an elevated risk for aortic regurgitation. The total calcification volume, degree of annular ovality and stent expansion were not associated with residual AR.
- 8 March 2016
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 12 (01) , 14-20
Vor- und Nachteile von selbstexpandierenden und ballonexpandierbaren Prothesen zur kathetergestützten Aortenklappenimplantation
Different biologic prostheses are currently in use for transcatheter aortic valve implantation. Recent experience has shown that balloon-expandable and self-expanding valves achieve similar clinical outcomes. In addition, numerous factors have been identified that are associated with favorable results with one or the other prosthesis type. At the same time, new prostheses with alternative stent designs and implantation techniques have been released on the market. Future research should aim at identifying further factors to ultimately enable prosthesis selection on an individual patient base
- 8 March 2016
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 12 (01) , 14-20
Vor- und Nachteile von selbstexpandierenden und ballonexpandierbaren Prothesen zur kathetergestützten Aortenklappenimplantation
Different biologic prostheses are currently in use for transcatheter aortic valve implantation. Recent experience has shown that balloon-expandable and self-expanding valves achieve similar clinical outcomes. In addition, numerous factors have been identified that are associated with favorable results with one or the other prosthesis type. At the same time, new prostheses with alternative stent designs and implantation techniques have been released on the market. Future research should aim at identifying further factors to ultimately enable prosthesis selection on an individual patient base
- Open Access
- 12 January 2016
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 17 (12) , 1385-1393
Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation
New-onset conduction disturbances still represent a considerable problem after transcatheter aortic valve implantation (TAVI). The aim of this study was to identify calcification patterns with an elevated risk for permanent pacemaker implantation (PPI) after TAVI and investigate underlying mechanisms in an ex vivo setting. One hundred and sixty-two patients who underwent TAVI with the Edwards SAPIEN XT® or Medtronic CoreValve® at our institution were analysed. The calcium load of the device landing zone was quantified with 3mensio®, and calcium patterns with an elevated risk for PPI were identified. Ex vivo simulations of balloon valvuloplasty were performed in 3D-printed silicone annuli of patients matching the identified risk profile. Patients with a calcium load of the left coronary cusp (LCC) above 209 mm3 had a higher rate of PPI than patients below this threshold (16.7 vs. 2.6%, P = 0.003). Multivariate regression revealed pre-existing right bundle branch block (RBBB) and increased LCC calcification as independent predictors for PPI. Simulation of the TAVI procedure in a silicone annulus revealed an off-centreline shift of the valvuloplasty balloon and transcatheter heart valve away from the LCC towards the commissure between right- and non-coronary cusp. Pre-existing RBBB and elevated LCC calcification were identified as independent predictors for PPI. These two risk factors enabled us to distinguish between patients according to their risk for PPI after TAVI. Ex vivo simulations suggested an off-centreline shift of the balloon as a possible explanation.
- 12 January 2016
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 17 (12) , 1385-1393
Open AccessCalcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation
New-onset conduction disturbances still represent a considerable problem after transcatheter aortic valve implantation (TAVI). The aim of this study was to identify calcification patterns with an elevated risk for permanent pacemaker implantation (PPI) after TAVI and investigate underlying mechanisms in an ex vivo setting. One hundred and sixty-two patients who underwent TAVI with the Edwards SAPIEN XT® or Medtronic CoreValve® at our institution were analysed. The calcium load of the device landing zone was quantified with 3mensio®, and calcium patterns with an elevated risk for PPI were identified. Ex vivo simulations of balloon valvuloplasty were performed in 3D-printed silicone annuli of patients matching the identified risk profile. Patients with a calcium load of the left coronary cusp (LCC) above 209 mm3 had a higher rate of PPI than patients below this threshold (16.7 vs. 2.6%, P = 0.003). Multivariate regression revealed pre-existing right bundle branch block (RBBB) and increased LCC calcification as independent predictors for PPI. Simulation of the TAVI procedure in a silicone annulus revealed an off-centreline shift of the valvuloplasty balloon and transcatheter heart valve away from the LCC towards the commissure between right- and non-coronary cusp. Pre-existing RBBB and elevated LCC calcification were identified as independent predictors for PPI. These two risk factors enabled us to distinguish between patients according to their risk for PPI after TAVI. Ex vivo simulations suggested an off-centreline shift of the balloon as a possible explanation.
- 13 August 2015
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 87 (5) , 989-992
Valve-in-valve using an Edwards Sapien XT into a JenaValve in a patient with a low originating left coronary artery and a heavily calcified aorta
- 13 August 2015
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 87 (5) , 989-992
Valve-in-valve using an Edwards Sapien XT into a JenaValve in a patient with a low originating left coronary artery and a heavily calcified aorta
- 23 July 2015
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 29 (4) , 241-253
Aktueller Stand der kathetergestützten Aortenklappenimplantation
- 23 July 2015
- Published by Springer Nature in Zeitschrift für Herz-,Thorax- und Gefäßchirurgie
- Vol. 29 (4) , 241-253
Aktueller Stand der kathetergestützten Aortenklappenimplantation
- Open Access
- 6 April 2015
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 21 (1) , 87-95
Development of an algorithm to plan and simulate a new interventional procedure
The number of implanted biological valves for treatment of valvular heart disease is growing and a percentage of these patients will eventually undergo a transcatheter valve-in-valve (ViV) procedure. Some of these patients will represent challenging cases. The aim of this study was to develop a feasible algorithm to plan and in vitro simulate a new interventional procedure to improve patient outcome. In addition to standard diagnostic routine, our algorithm includes 3D printing of the annulus, hydrodynamic measurements and high-speed analysis of leaflet kinematics after simulation of the procedure in different prosthesis positions as well as X-ray imaging of the most suitable valve position to create a ‘blueprint’ for the patient procedure. This algorithm was developed for a patient with a degenerated Perceval aortic sutureless prosthesis requiring a ViV procedure. Different ViV procedures were assessed in the algorithm and based on these results the best option for the patient was chosen. The actual procedure went exactly as planned with help of this algorithm. Here we have developed a new technically feasible algorithm simulating important aspects of a novel interventional procedure prior to the actual procedure. This algorithm can be applied to virtually all patients requiring a novel interventional procedure to help identify risks and find optimal parameters for prosthesis selection and placement in order to maximize safety for the patient.
- 6 April 2015
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 21 (1) , 87-95
Open AccessDevelopment of an algorithm to plan and simulate a new interventional procedure
The number of implanted biological valves for treatment of valvular heart disease is growing and a percentage of these patients will eventually undergo a transcatheter valve-in-valve (ViV) procedure. Some of these patients will represent challenging cases. The aim of this study was to develop a feasible algorithm to plan and in vitro simulate a new interventional procedure to improve patient outcome. In addition to standard diagnostic routine, our algorithm includes 3D printing of the annulus, hydrodynamic measurements and high-speed analysis of leaflet kinematics after simulation of the procedure in different prosthesis positions as well as X-ray imaging of the most suitable valve position to create a ‘blueprint’ for the patient procedure. This algorithm was developed for a patient with a degenerated Perceval aortic sutureless prosthesis requiring a ViV procedure. Different ViV procedures were assessed in the algorithm and based on these results the best option for the patient was chosen. The actual procedure went exactly as planned with help of this algorithm. Here we have developed a new technically feasible algorithm simulating important aspects of a novel interventional procedure prior to the actual procedure. This algorithm can be applied to virtually all patients requiring a novel interventional procedure to help identify risks and find optimal parameters for prosthesis selection and placement in order to maximize safety for the patient.