Atsushi Nozaki
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Atsushi Nozaki has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Akihiro Tanimoto
Department of Diagnostic Radiology, Keio University School of Medicine, Tokyo, Japan
1 shared publication Chihiro Mori
Department of Radiology, Ehime Prefectural Central Hospital, Kasuga-machi, Matsuyama, Ehime
1 shared publication- Hidenobu Takagi
Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan
1 shared publication - Hironobu Ueda
Division of Cardiology, Department of Internal Medicine, Iwate Medical University , Iwate , Japan
1 shared publication - Jumpei Fujiwara
Division of Cardiology, Department of Internal Medicine, Iwate Medical University , Iwate , Japan
1 shared publication - Jun Fujita
Keio University School of Medicine
1 shared publication
Latest Publications
- 10 February 2023
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 47 (4) , 524-529
Comparisons of Hepatobiliary Phase Imaging Using Combinations of Parallel Imaging and Variable Degrees of Compressed Sensing With Use of Parallel Imaging Alone
Objective: This study aimed to compare the image quality in the hepatobiliary phase images of gadoxetic acid–enhanced liver magnetic resonance imaging using parallel imaging (PI) and compressed sensing (CS) reconstruction, using variable CS factors with the standard method using the PI technique. Methods: In this study, 64 patients who underwent gadoxetic acid–enhanced liver magnetic resonance imaging at 3.0 T were enrolled. Hepatobiliary phase images were acquired 6 times using liver acquisition with volume acceleration (LAVA) and CS reconstruction with 5 CS factors 1.4, 1.6, 1.8, 2.0, and 2.5 (LAVA-CS 1.4, 1.6, 1.8, 2.0, and 2.5) and standard LAVA (LAVA-noCS). For objective analysis, the signal intensity ratios (SIRs) of the liver-to-spleen (SIRliver/spleen), liver-to-portal vein (SIRliver/portal vein), and liver-to-fat (SIRliver/fat) were estimated. For subjective analysis, 2 radiologists independently evaluated the quality of all the images. Results: The objective analysis demonstrated no significant difference in all evaluation parameters of all the images. Subjective analysis revealed that the scores of all evaluation items were higher for LAVA-noCS images than for LAVA-CS images, and only LAVA-CS 1.4 did not significantly differ from LAVA-noCS in all evaluation items (P = 1.00 in 2 readers). Conclusions: A CS factor of 1.4 in the hepatobiliary phase image with combined PI and CS can reduce the scan time without degrading the image quality compared with the standard method.
- 10 February 2023
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 47 (4) , 524-529
Comparisons of Hepatobiliary Phase Imaging Using Combinations of Parallel Imaging and Variable Degrees of Compressed Sensing With Use of Parallel Imaging Alone
Objective: This study aimed to compare the image quality in the hepatobiliary phase images of gadoxetic acid–enhanced liver magnetic resonance imaging using parallel imaging (PI) and compressed sensing (CS) reconstruction, using variable CS factors with the standard method using the PI technique. Methods: In this study, 64 patients who underwent gadoxetic acid–enhanced liver magnetic resonance imaging at 3.0 T were enrolled. Hepatobiliary phase images were acquired 6 times using liver acquisition with volume acceleration (LAVA) and CS reconstruction with 5 CS factors 1.4, 1.6, 1.8, 2.0, and 2.5 (LAVA-CS 1.4, 1.6, 1.8, 2.0, and 2.5) and standard LAVA (LAVA-noCS). For objective analysis, the signal intensity ratios (SIRs) of the liver-to-spleen (SIRliver/spleen), liver-to-portal vein (SIRliver/portal vein), and liver-to-fat (SIRliver/fat) were estimated. For subjective analysis, 2 radiologists independently evaluated the quality of all the images. Results: The objective analysis demonstrated no significant difference in all evaluation parameters of all the images. Subjective analysis revealed that the scores of all evaluation items were higher for LAVA-noCS images than for LAVA-CS images, and only LAVA-CS 1.4 did not significantly differ from LAVA-noCS in all evaluation items (P = 1.00 in 2 readers). Conclusions: A CS factor of 1.4 in the hepatobiliary phase image with combined PI and CS can reduce the scan time without degrading the image quality compared with the standard method.
- Open Access
- 18 March 2021
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 94 (1120) , 20201249
Reliability of respiratory-triggered two-dimensional cine k-adaptive-t-autocalibrating reconstruction for Cartesian sampling for the assessment of biventricular volume and function in patients with repaired tetralogy of Fallot
Objective: To compare left ventricular (LV) and right ventricular (RV) volume, function, and image quality of a respiratory-triggered two-dimensional (2D)-cine k-adaptive-t-autocalibrating reconstruction for Cartesian sampling (2D kat-ARC) with those of the standard reference, namely, breath-hold 2D balanced steady-state free precession (2D SSFP), in patients with repaired tetralogy of Fallot (TOF). Methods: 30 patients (14 males, mean age 32.2 ± 13.9 years) underwent cardiac magnetic resonance, and 2D kat-ARC and 2D SSFP images were acquired on short-axis view. Biventricular end-diastolic volume (EDV) and end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass (LVM) were analysed. Results: The 2D kat-ARC had significantly shorter scan time (35.2 ± 9.1 s vs 80.4 ± 16.7 s; p < 0.0001). Despite an analysis of image quality showed significant impairment using 2D kat-ARC compared to 2D SSFP cine (p < 0.0001), the two sequences demonstrated no significant difference in terms of biventricular EDV, LVESV, LVSV, LVEF, and LVM. However, the RVESV was overestimated for 2D kat-ARC compared with that for 2D SSFP (73.8 ± 43.2 ml vs 70.3 ± 44.5 ml, p = 0.0002) and the RVSV and RVEF were underestimated (RVSV = 46.2±20.5 ml vs 49.4 ± 20.4 ml, p = 0.0024; RVEF = 40.2±12.7% vs. 43.5±14.0%, p = 0.0002). Conclusion: Respiratory-triggered 2D kat-ARC cine is a reliable technique that could be used in the evaluation of LV volumes and function. Advances in knowledge: 2D cine kat-ARC is a reliable technique for the assessment LV volume and function in patients with repaired TOF.
- 18 March 2021
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 94 (1120) , 20201249
Open AccessReliability of respiratory-triggered two-dimensional cine k-adaptive-t-autocalibrating reconstruction for Cartesian sampling for the assessment of biventricular volume and function in patients with repaired tetralogy of Fallot
Objective: To compare left ventricular (LV) and right ventricular (RV) volume, function, and image quality of a respiratory-triggered two-dimensional (2D)-cine k-adaptive-t-autocalibrating reconstruction for Cartesian sampling (2D kat-ARC) with those of the standard reference, namely, breath-hold 2D balanced steady-state free precession (2D SSFP), in patients with repaired tetralogy of Fallot (TOF). Methods: 30 patients (14 males, mean age 32.2 ± 13.9 years) underwent cardiac magnetic resonance, and 2D kat-ARC and 2D SSFP images were acquired on short-axis view. Biventricular end-diastolic volume (EDV) and end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass (LVM) were analysed. Results: The 2D kat-ARC had significantly shorter scan time (35.2 ± 9.1 s vs 80.4 ± 16.7 s; p < 0.0001). Despite an analysis of image quality showed significant impairment using 2D kat-ARC compared to 2D SSFP cine (p < 0.0001), the two sequences demonstrated no significant difference in terms of biventricular EDV, LVESV, LVSV, LVEF, and LVM. However, the RVESV was overestimated for 2D kat-ARC compared with that for 2D SSFP (73.8 ± 43.2 ml vs 70.3 ± 44.5 ml, p = 0.0002) and the RVSV and RVEF were underestimated (RVSV = 46.2±20.5 ml vs 49.4 ± 20.4 ml, p = 0.0024; RVEF = 40.2±12.7% vs. 43.5±14.0%, p = 0.0002). Conclusion: Respiratory-triggered 2D kat-ARC cine is a reliable technique that could be used in the evaluation of LV volumes and function. Advances in knowledge: 2D cine kat-ARC is a reliable technique for the assessment LV volume and function in patients with repaired TOF.
- 30 April 2015
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 33 (7) , 911-917
Three-dimensional cardiac cine imaging using the kat ARC acceleration: Initial experience in clinical adult patients at 3T
- 30 April 2015
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 33 (7) , 911-917
Three-dimensional cardiac cine imaging using the kat ARC acceleration: Initial experience in clinical adult patients at 3T