Muhammad Afzal Kamboh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Muhammad Afzal Kamboh has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Hamid Rashidi Nodeh
Department of Chemistry, Faculty of Science University of Tehran Tehran Iran
4 shared publications - Sadaf Sadia Arain
National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan
4 shared publications - Sharifah Mohamad
Department of Chemistry, Faculty of Science, University of Malaya, Lembah Pantai 50603, Kuala Lumpur, Malaysia
4 shared publications - Abdul Haleem Panhwar
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan
3 shared publications - Hassan Imran Afridi
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, Pakistan
3 shared publications - Kapil Dev Brahman
National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
3 shared publications
Latest Publications
- Open Access
Headspace Extraction of Chlorobenzenes from Water Using Electrospun Nanofibers Fabricated with Calix[4]arene-Doped Polyurethane–Polysulfone
Chlorobenzenes (CBs) are persistent and potentially have a carcinogenic effect on mammals. Thus, the determination of CBs is essential for human health. Hence, in this study, novel polyurethane–polysulfone/calix[4]arene (PU-PSU/calix[4]arene) nanofibers were synthesized using an electrospinning approach over in-situ coating on a stainless-steel wire. The nanosorbent was comprehensively characterized using scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FT-IR) techniques. The SEM analysis depicted the nanofiber’s unique morphology and size distribution in the range of 50–200 nm. To determine the levels of 1,2,4-trichlorobenzene, 1,2,3-trichlorobenzene, and 1,2,3,4-tetrachlorobenzene in water samples, freshly prepared nanosorbent was employed using headspace-solid phase microextraction (HS-SPME) in combination with gas chromatography micro electron capture detector (GC-µECD). Other calixarenes, such as sulfonated calix[4]arene, p-tert-calixarene, and calix[6]arene were also examined, and among the fabricated sorbents, the PU–PSU/calix[4]arene showed the highest efficiency. The key variables of the procedure, including ionic strength, extraction temperature, extraction duration, and desorption conditions were examined. Under optimal conditions, the LOD (0.1–1.0 pg mL−1), the LDR (0.4–1000 pg mL−1), and the R2 > 0.990 were determined. Additionally, the repeatability from fiber to fiber and the intra-day and inter-day reproducibility were determined to be 1.4–6.0, 4.7–10.1, and 0.9–9.7%, respectively. The nanofiber adsorption capacity was found to be 670–720 pg/g for CBs at an initial concentration of 400 pg mL−1. A satisfactory recovery of 80–106% was attained when the suggested method’s application for detecting chlorobenzenes (CBs) in tap water, river water, sewage water, and industrial water was assessed.
Open AccessHeadspace Extraction of Chlorobenzenes from Water Using Electrospun Nanofibers Fabricated with Calix[4]arene-Doped Polyurethane–Polysulfone
Chlorobenzenes (CBs) are persistent and potentially have a carcinogenic effect on mammals. Thus, the determination of CBs is essential for human health. Hence, in this study, novel polyurethane–polysulfone/calix[4]arene (PU-PSU/calix[4]arene) nanofibers were synthesized using an electrospinning approach over in-situ coating on a stainless-steel wire. The nanosorbent was comprehensively characterized using scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FT-IR) techniques. The SEM analysis depicted the nanofiber’s unique morphology and size distribution in the range of 50–200 nm. To determine the levels of 1,2,4-trichlorobenzene, 1,2,3-trichlorobenzene, and 1,2,3,4-tetrachlorobenzene in water samples, freshly prepared nanosorbent was employed using headspace-solid phase microextraction (HS-SPME) in combination with gas chromatography micro electron capture detector (GC-µECD). Other calixarenes, such as sulfonated calix[4]arene, p-tert-calixarene, and calix[6]arene were also examined, and among the fabricated sorbents, the PU–PSU/calix[4]arene showed the highest efficiency. The key variables of the procedure, including ionic strength, extraction temperature, extraction duration, and desorption conditions were examined. Under optimal conditions, the LOD (0.1–1.0 pg mL−1), the LDR (0.4–1000 pg mL−1), and the R2 > 0.990 were determined. Additionally, the repeatability from fiber to fiber and the intra-day and inter-day reproducibility were determined to be 1.4–6.0, 4.7–10.1, and 0.9–9.7%, respectively. The nanofiber adsorption capacity was found to be 670–720 pg/g for CBs at an initial concentration of 400 pg mL−1. A satisfactory recovery of 80–106% was attained when the suggested method’s application for detecting chlorobenzenes (CBs) in tap water, river water, sewage water, and industrial water was assessed.
- Retracted
- 1 October 2021
- Published by Elsevier in Environmental Research
- Vol. 201, 111588
RETRACTED: Green sporopollenin supported cyanocalixarene based magnetic adsorbent for pesticides removal from water: Kinetic and equilibrium studies
- 1 October 2021
- Published by Elsevier in Environmental Research
- Vol. 201, 111588
RetractedRETRACTED: Green sporopollenin supported cyanocalixarene based magnetic adsorbent for pesticides removal from water: Kinetic and equilibrium studies
- 1 April 2021
- Published by Elsevier in Chemosphere
- Vol. 268, 129348
Nitrile-calixarene grafted magnetic graphene oxide for removal of arsenic from aqueous media: Isotherm, kinetic and thermodynamic studies
- 1 April 2021
- Published by Elsevier in Chemosphere
- Vol. 268, 129348
Nitrile-calixarene grafted magnetic graphene oxide for removal of arsenic from aqueous media: Isotherm, kinetic and thermodynamic studies
- Open Access
Synthesis of Polyaniline-Coated Graphene Oxide@SrTiO3 Nanocube Nanocomposites for Enhanced Removal of Carcinogenic Dyes from Aqueous Solution
The present investigation highlights the synthesis of polyaniline (PANI)-coated graphene oxide doped with SrTiO3 nanocube nanocomposites through facile in situ oxidative polymerization method for the efficient removal of carcinogenic dyes, namely, the cationic dye methylene blue (MB) and the anionic dye methyl orange (MO). The presence of oxygenated functional groups comprised of hydroxyl and epoxy groups in graphene oxide (GO) and nitrogen-containing functionalities such as imine groups and amine groups in polyaniline work synergistically to impart cationic and anionic nature to the synthesised nanocomposite, whereas SrTiO3 nanocubes act as spacers aiding in segregation of GO sheets, thereby increasing the effective surface area of nanocomposite. The synthesised nanocomposites were characterised by field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), thermogravimetric analysis (TGA), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adsorption efficiencies of graphene oxide (GO), PANI homopolymer, and SrTiO3 nanocubes-doped nanocomposites were assessed by monitoring the adsorption of methylene blue and methyl orange dyes from aqueous solution. The adsorption efficiency of nanocomposites doped with SrTiO3 nanocubes were found to be of higher magnitude as compared with undoped nanocomposite. Moreover, the nanocomposite with 2 wt % SrTiO3 with respect to graphene oxide demonstrated excellent adsorption behaviour with 99% and 91% removal of MB and MO, respectively, in a very short duration of time.
Open AccessSynthesis of Polyaniline-Coated Graphene Oxide@SrTiO3 Nanocube Nanocomposites for Enhanced Removal of Carcinogenic Dyes from Aqueous Solution
The present investigation highlights the synthesis of polyaniline (PANI)-coated graphene oxide doped with SrTiO3 nanocube nanocomposites through facile in situ oxidative polymerization method for the efficient removal of carcinogenic dyes, namely, the cationic dye methylene blue (MB) and the anionic dye methyl orange (MO). The presence of oxygenated functional groups comprised of hydroxyl and epoxy groups in graphene oxide (GO) and nitrogen-containing functionalities such as imine groups and amine groups in polyaniline work synergistically to impart cationic and anionic nature to the synthesised nanocomposite, whereas SrTiO3 nanocubes act as spacers aiding in segregation of GO sheets, thereby increasing the effective surface area of nanocomposite. The synthesised nanocomposites were characterised by field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), thermogravimetric analysis (TGA), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adsorption efficiencies of graphene oxide (GO), PANI homopolymer, and SrTiO3 nanocubes-doped nanocomposites were assessed by monitoring the adsorption of methylene blue and methyl orange dyes from aqueous solution. The adsorption efficiency of nanocomposites doped with SrTiO3 nanocubes were found to be of higher magnitude as compared with undoped nanocomposite. Moreover, the nanocomposite with 2 wt % SrTiO3 with respect to graphene oxide demonstrated excellent adsorption behaviour with 99% and 91% removal of MB and MO, respectively, in a very short duration of time.
- Open Access
- 11 August 2016
- Published by MDPI AG in Preprints.org
Synthesis of Polyaniline coated Graphene Oxide @ SrTiO3 Nanocube Nanocomposites for Enhanced Removal of Carcinogenic Dyes from Aqueous Solution
The present investigation highlights the synthesis of polyaniline (PANI) coated graphene oxide doped with SrTiO3 nanocube nanocomposites through facile in-situ oxidative polymerization method for the efficient removal of carcinogenic dyes, namely, the cationic dye methylene blue (MB) and the anionic dye methyl orange (MO). The synthesised nanocomposites were characterised by field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), thermogravimetric analysis (TGA), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adsorption efficiencies of graphene oxide (GO), PANI homopolymer and SrTiO3 nanocubes-doped nanocomposites were assessed by monitoring the adsorption of methylene blue and methyl orange dyes from aqueous solution. The adsorption efficiency of nanocomposites doped with SrTiO3 nanocubes were found to be of higher magnitude as compared with undoped nanocomposite. Moreover, the nanocomposite with 2 wt% SrTiO3 with respect to graphene oxide demonstrated excellent adsorption behaviour with 99% and 91% removal of MB and MO respectively, in a very short duration of time.
- 11 August 2016
- Published by MDPI AG in Preprints.org
Open AccessSynthesis of Polyaniline coated Graphene Oxide @ SrTiO3 Nanocube Nanocomposites for Enhanced Removal of Carcinogenic Dyes from Aqueous Solution
The present investigation highlights the synthesis of polyaniline (PANI) coated graphene oxide doped with SrTiO3 nanocube nanocomposites through facile in-situ oxidative polymerization method for the efficient removal of carcinogenic dyes, namely, the cationic dye methylene blue (MB) and the anionic dye methyl orange (MO). The synthesised nanocomposites were characterised by field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), thermogravimetric analysis (TGA), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adsorption efficiencies of graphene oxide (GO), PANI homopolymer and SrTiO3 nanocubes-doped nanocomposites were assessed by monitoring the adsorption of methylene blue and methyl orange dyes from aqueous solution. The adsorption efficiency of nanocomposites doped with SrTiO3 nanocubes were found to be of higher magnitude as compared with undoped nanocomposite. Moreover, the nanocomposite with 2 wt% SrTiO3 with respect to graphene oxide demonstrated excellent adsorption behaviour with 99% and 91% removal of MB and MO respectively, in a very short duration of time.
- 9 August 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (80) , 77047-77058
Magnetic solid phase extraction of polycyclic aromatic hydrocarbons and chlorophenols based on cyano-ionic liquid functionalized magnetic nanoparticles and their determination by HPLC-DAD
A magnetic solid-phase extraction (MSPE) procedure on the newly synthesized cyano-ionic liquid functionalized magnetic nanoparticles (MNP@CN/IL) was established and validated for the separation/preconcentration of polycyclic aromatic hydrocarbons (PAHs) and chlorophenols (CPs) from water samples prior to their HPLC-DAD determination. The new magnetic (MNP@CN/IL) adsorbent was characterized by Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), elemental analysis (CHNS), energy-dispersive X-ray spectroscopy (EDX), vibrating sample magnetometry (VSM), thermal gravimetric analysis (TGA) and transmission electron microscopy (TEM). The proposed method showed preconcentrations of 200 and 100 with low limits of detection (LOD = 0.40–0.59 and 0.35–0.67 μg L−1) with linearity ranges from 0.1–100 and 3–100 μg L−1 for PAHs and CPs, respectively. The extraction recoveries from environmental samples (leachate and sludge from a landfill site) ranged from 89.50–110.2% and 80.67–112.7% for PAHs and CPs, respectively, with satisfactory precision (% RSD less than 5%). The combination of cyano group and ionic liquid on the surface of the MNPs enhanced the extraction efficiency which might be due to π–π interactions as well as electrostatic interactions.
- 9 August 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (80) , 77047-77058
Magnetic solid phase extraction of polycyclic aromatic hydrocarbons and chlorophenols based on cyano-ionic liquid functionalized magnetic nanoparticles and their determination by HPLC-DAD
A magnetic solid-phase extraction (MSPE) procedure on the newly synthesized cyano-ionic liquid functionalized magnetic nanoparticles (MNP@CN/IL) was established and validated for the separation/preconcentration of polycyclic aromatic hydrocarbons (PAHs) and chlorophenols (CPs) from water samples prior to their HPLC-DAD determination. The new magnetic (MNP@CN/IL) adsorbent was characterized by Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), elemental analysis (CHNS), energy-dispersive X-ray spectroscopy (EDX), vibrating sample magnetometry (VSM), thermal gravimetric analysis (TGA) and transmission electron microscopy (TEM). The proposed method showed preconcentrations of 200 and 100 with low limits of detection (LOD = 0.40–0.59 and 0.35–0.67 μg L−1) with linearity ranges from 0.1–100 and 3–100 μg L−1 for PAHs and CPs, respectively. The extraction recoveries from environmental samples (leachate and sludge from a landfill site) ranged from 89.50–110.2% and 80.67–112.7% for PAHs and CPs, respectively, with satisfactory precision (% RSD less than 5%). The combination of cyano group and ionic liquid on the surface of the MNPs enhanced the extraction efficiency which might be due to π–π interactions as well as electrostatic interactions.
- 4 May 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (55) , 49358-49369
A novel cyano functionalized silica-titania oxide sol–gel based ionic liquid for the extraction of hazardous chlorophenols from aqueous environments
In the present investigation a cyano functionalized silica-titania oxide sol–gel based ionic liquid (Si-Ti@CN/IL) has been successfully synthesised via sol–gel immobilization of cyanopropyltriethoxysilane and 1-benzyl-3-(trimethoxysilylpropyl)imidazolium chloride ionic liquid (BTMP-IM) on the silica-titania mixed oxide surface. The newly prepared Si-Ti@CN/IL was used as an adsorbent for the separation/preconcentration of chlorophenols from water samples prior to their HPLC-UV determination. Synthesis of Si-Ti@CN/IL was confirmed by Fourier transform infrared (FT-IR) spectroscopy, field emission scanning electron microscopy (FESEM), Brunauer–Emmett–Teller (BET), thermo gravimetric analysis (TGA), X-ray diffraction (XRD) and elemental (CHNS) analysis. During the extraction process, various kinds of interactions such as π–π interactions and hydrogen bonding between the anionic/cationic sites were monitored. The extraction of chlorophenols on Si-Ti@CN/IL is highly pH dependent and a significant percent extraction was achieved at pH = 2. The Si-Ti@CN/IL provided low limit of detection (LOD = 0.83–0.95 μg L−1) with a linearity range from 10–1000 μg L−1 (LOQ = 2.77–3.17 μg L−1). The field studies with high recovery (73.39–105.54%) as well as acceptable precision (%RSD 0.82–4.19) also supported the effectiveness of Si-Ti@CN/IL, which could be useful for the extraction of selected chlorophenols from tap water, lake water and leachate from landfill sites. The comparative data support Si-Ti@CN/IL as an effective extractant for selected chlorophenols.
- 4 May 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (55) , 49358-49369
A novel cyano functionalized silica-titania oxide sol–gel based ionic liquid for the extraction of hazardous chlorophenols from aqueous environments
In the present investigation a cyano functionalized silica-titania oxide sol–gel based ionic liquid (Si-Ti@CN/IL) has been successfully synthesised via sol–gel immobilization of cyanopropyltriethoxysilane and 1-benzyl-3-(trimethoxysilylpropyl)imidazolium chloride ionic liquid (BTMP-IM) on the silica-titania mixed oxide surface. The newly prepared Si-Ti@CN/IL was used as an adsorbent for the separation/preconcentration of chlorophenols from water samples prior to their HPLC-UV determination. Synthesis of Si-Ti@CN/IL was confirmed by Fourier transform infrared (FT-IR) spectroscopy, field emission scanning electron microscopy (FESEM), Brunauer–Emmett–Teller (BET), thermo gravimetric analysis (TGA), X-ray diffraction (XRD) and elemental (CHNS) analysis. During the extraction process, various kinds of interactions such as π–π interactions and hydrogen bonding between the anionic/cationic sites were monitored. The extraction of chlorophenols on Si-Ti@CN/IL is highly pH dependent and a significant percent extraction was achieved at pH = 2. The Si-Ti@CN/IL provided low limit of detection (LOD = 0.83–0.95 μg L−1) with a linearity range from 10–1000 μg L−1 (LOQ = 2.77–3.17 μg L−1). The field studies with high recovery (73.39–105.54%) as well as acceptable precision (%RSD 0.82–4.19) also supported the effectiveness of Si-Ti@CN/IL, which could be useful for the extraction of selected chlorophenols from tap water, lake water and leachate from landfill sites. The comparative data support Si-Ti@CN/IL as an effective extractant for selected chlorophenols.
- 15 May 2015
- Published by Springer Nature in Biological Trace Element Research
- Vol. 168 (2) , 287-295
Correlation of Arsenic Levels in Smokeless Tobacco Products and Biological Samples of Oral Cancer Patients and Control Consumers
It has been extensively reported that chewing of smokeless tobacco (SLT) can lead to cancers of oral cavity. In present study, the relationship between arsenic (As) exposure via chewing/inhaling different SLT products in oral cancer patients have or/not consumed SLT products was studied. The As in different types of SLT products (gutkha, mainpuri, and snuff) and biological (scalp hair and blood) samples of different types of oral cancer patients and controls were analyzed. Both controls and oral cancer patients have same age group (ranged 30–60 years), socio-economic status, localities, and dietary habits. The concentrations of As in SLT products and biological samples were measured by electrothermal atomic absorption spectrophotometer after microwave-assisted acid digestion. The validity and accuracy of the methodology were checked by certified reference materials. The resulted data of present study indicates that the concentration of As was significantly higher in scalp hair and blood samples of oral cancer patients than those of controls (p p > 0.01). The intake of As via consuming different SLT may have synergistic effects, in addition to other risk factors associated with oral cancer.
- 15 May 2015
- Published by Springer Nature in Biological Trace Element Research
- Vol. 168 (2) , 287-295
Correlation of Arsenic Levels in Smokeless Tobacco Products and Biological Samples of Oral Cancer Patients and Control Consumers
It has been extensively reported that chewing of smokeless tobacco (SLT) can lead to cancers of oral cavity. In present study, the relationship between arsenic (As) exposure via chewing/inhaling different SLT products in oral cancer patients have or/not consumed SLT products was studied. The As in different types of SLT products (gutkha, mainpuri, and snuff) and biological (scalp hair and blood) samples of different types of oral cancer patients and controls were analyzed. Both controls and oral cancer patients have same age group (ranged 30–60 years), socio-economic status, localities, and dietary habits. The concentrations of As in SLT products and biological samples were measured by electrothermal atomic absorption spectrophotometer after microwave-assisted acid digestion. The validity and accuracy of the methodology were checked by certified reference materials. The resulted data of present study indicates that the concentration of As was significantly higher in scalp hair and blood samples of oral cancer patients than those of controls (p p > 0.01). The intake of As via consuming different SLT may have synergistic effects, in addition to other risk factors associated with oral cancer.
- 1 May 2015
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 187 (5) , 1-13
Preconcentration and determination of lead and cadmium levels in blood samples of adolescent workers consuming smokeless tobacco products in Pakistan
The present study was aimed to evaluate the cadmium (Cd) and lead (Pb) levels in the blood samples of adolescent boys, chewing different smokeless tobacco (SLT) products in Pakistan. For comparative purpose, boys of the same age group (12–15 years), not consumed any SLT products were selected as referents. To determine trace levels of Cd and Pb in blood samples, a preconcentration method, vortex-assisted liquid–liquid microextraction (VLLME) has been developed, prior to analysis by flame atomic absorption spectrometry. The hydrophobic chelates of Cd and Pb with ammonium pyrrolidinedithiocarbamate were extracted into the fine droplets of ionic liquid (IL) 1-butyl-3-methylimidazolium hexafluorophosphate, while nonionic surfactant, Triton X-114 was used as a dispersing medium. The main factors affecting the recoveries of Cd and Pb, such as concentration of APDC, centrifugation time, volume of IL and TX-114, were investigated in detail. It was also observed that adolescent boys who consumed different SLT products have 2- to 3-fold higher levels of Cd and Pb in their blood samples as compared to referent boys (p < 0.001).
- 1 May 2015
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 187 (5) , 1-13
Preconcentration and determination of lead and cadmium levels in blood samples of adolescent workers consuming smokeless tobacco products in Pakistan
The present study was aimed to evaluate the cadmium (Cd) and lead (Pb) levels in the blood samples of adolescent boys, chewing different smokeless tobacco (SLT) products in Pakistan. For comparative purpose, boys of the same age group (12–15 years), not consumed any SLT products were selected as referents. To determine trace levels of Cd and Pb in blood samples, a preconcentration method, vortex-assisted liquid–liquid microextraction (VLLME) has been developed, prior to analysis by flame atomic absorption spectrometry. The hydrophobic chelates of Cd and Pb with ammonium pyrrolidinedithiocarbamate were extracted into the fine droplets of ionic liquid (IL) 1-butyl-3-methylimidazolium hexafluorophosphate, while nonionic surfactant, Triton X-114 was used as a dispersing medium. The main factors affecting the recoveries of Cd and Pb, such as concentration of APDC, centrifugation time, volume of IL and TX-114, were investigated in detail. It was also observed that adolescent boys who consumed different SLT products have 2- to 3-fold higher levels of Cd and Pb in their blood samples as compared to referent boys (p < 0.001).