Régis Verdier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Régis Verdier has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Jacques H. Caton
Clinique Emilie de Vialar, 116 rue Antoine Charial, 69003, Lyon, France
3 shared publications- Jean Louis Prudhon
Clinique des Cèdres, 21 rue Albert Londres, 38432, Echirolles, France,
3 shared publications Jean-Marc Puch
Clinique Saint-Georges, 2 Avenue de Rimiez, 06100, Nice, France
2 shared publicationsLoys Descamps
Clinique Saint-Georges, 2 Avenue de Rimiez, 06100, Nice, France
2 shared publicationsThierry Aslanian
Groupe lépine, Genay, 175 rue Jacquard, CS 50307-69727, Genay Cedex, France
2 shared publicationsAndré Ferreira
Clinique du Parc 155 Ter Boulevard de Stalingrad 69006 Lyon France
1 shared publication
Latest Publications
- 7 July 2017
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (2) , 311-316
How is patella height modified after total knee arthroplasty?
Since the first measurement method of patella height in 1929 (Janssen), more than 16 methods have been described. Most of these measures are not suitable to measure patella height after total knee arthroplasty (TKA). One of us (JC) modified the original Caton Deschamps (oCD), index with a new relative index called modified Caton Deschamps (mCD) index, by using new landmarks. The purpose of this study was to determine how patella height is modified after TKA.
- 7 July 2017
- Published by Springer Nature in International Orthopaedics
- Vol. 42 (2) , 311-316
How is patella height modified after total knee arthroplasty?
Since the first measurement method of patella height in 1929 (Janssen), more than 16 methods have been described. Most of these measures are not suitable to measure patella height after total knee arthroplasty (TKA). One of us (JC) modified the original Caton Deschamps (oCD), index with a new relative index called modified Caton Deschamps (mCD) index, by using new landmarks. The purpose of this study was to determine how patella height is modified after TKA.
- 20 December 2016
- Published by Springer Nature in International Orthopaedics
- Vol. 41 (3) , 563-571
Low friction arthroplasty and dual mobility cup: a new gold standard
Introduction Low friction arthroplasty (LFA) introduced by Sir John Charnley was the gold standard for many years. Dislocation and infection are the first causes for early revision. Late failures are polyethylene (PE) wear and loosening. Due to dislocation risk we slowly switched to the use of LFA with dual mobility cups (DMC). The purposes of this study are (1) to assess whether our changes have improved outcomes and (2) what is the new gold standard? Material and methods We selected from an observational registry of 1,091 cases of hybrid Charnley total hip arthroplasty (THA). The acetabular component was either DMC in 455 cases or fixed cup (FC) in 636 cases. Results Three dislocations (0.6%) occurred in the DMC group (none revised). In the FC group 54 dislocated (8.49%) and 20 were recurrent and underwent revision (revision rate 3.14%). In the DMC group, five acetabular and three femoral revisions were performed (revision rate for loosening 1.7%). In the FC group 19 cases underwent acetabular revision, and five cases had femoral component revised (revision rate for loosening 3.7%). Discussion Charnley's LFA has proven over 50 years of excellent survivorship. To decrease dislocation risk, one suggested increasing femoral head diameter. Gilles Bousquet proposed another way, namely, the DMC concept. Dislocation is no longer a critical issue with DMC as demonstrated in our series and main series. DMC in primary THA is still a subject of debate. Mid-term results do not demonstrate a higher rate of wear than LFA. What is the current gold standard? LFA was and is our current gold standard in association with a DMC.
- 20 December 2016
- Published by Springer Nature in International Orthopaedics
- Vol. 41 (3) , 563-571
Low friction arthroplasty and dual mobility cup: a new gold standard
Introduction Low friction arthroplasty (LFA) introduced by Sir John Charnley was the gold standard for many years. Dislocation and infection are the first causes for early revision. Late failures are polyethylene (PE) wear and loosening. Due to dislocation risk we slowly switched to the use of LFA with dual mobility cups (DMC). The purposes of this study are (1) to assess whether our changes have improved outcomes and (2) what is the new gold standard? Material and methods We selected from an observational registry of 1,091 cases of hybrid Charnley total hip arthroplasty (THA). The acetabular component was either DMC in 455 cases or fixed cup (FC) in 636 cases. Results Three dislocations (0.6%) occurred in the DMC group (none revised). In the FC group 54 dislocated (8.49%) and 20 were recurrent and underwent revision (revision rate 3.14%). In the DMC group, five acetabular and three femoral revisions were performed (revision rate for loosening 1.7%). In the FC group 19 cases underwent acetabular revision, and five cases had femoral component revised (revision rate for loosening 3.7%). Discussion Charnley's LFA has proven over 50 years of excellent survivorship. To decrease dislocation risk, one suggested increasing femoral head diameter. Gilles Bousquet proposed another way, namely, the DMC concept. Dislocation is no longer a critical issue with DMC as demonstrated in our series and main series. DMC in primary THA is still a subject of debate. Mid-term results do not demonstrate a higher rate of wear than LFA. What is the current gold standard? LFA was and is our current gold standard in association with a DMC.
- 8 November 2016
- Published by Springer Nature in International Orthopaedics
- Vol. 41 (3) , 475-480
Dual-mobility cup in total hip arthroplasty in patients less than fifty five years and over ten years of follow-up
We report clinical and radiological outcome of a dual mobility cup (DMC) of 2nd generation after a minimum of ten year-follow-up (FU). The goal of this work was to compare the results of this DMC in patients aged less than 55 years and in patients aged more than 55 years. From 2000 to 2005, a prospective and consecutive series of 119 THAs with a cementless DMC of 2nd generation (GIROS) were performed in patients aged less than 55 years and 444 in patients aged more than 55 years. The mean FU was 11 years (8 to 15 years). Survivorships (failure of both components or cup loosening) were not different between patients aged less than 55 years and patients aged more than 55 years. There was no dislocation. DEVANE classification, Harris, PMA and Oxford scores improved after THA but no difference could be found between between < 55 years and > 55 years patients. These results are better than those of first generation (BOUSQUET) DMC (77 % of survival rate at 20 years of FU). These results are in the same agreement than those of the literature: 99 % of survival rate at 14.2 years of FU for KERBOULL with a low friction arthroplasty and 96.5 % at ten years of FU for ceramic/ceramic bearing (R CHANA). The DMC for young patient is a relevant surgical option with no dislocation and excellent clinical results and survival rate at more than ten years of FU.
- 8 November 2016
- Published by Springer Nature in International Orthopaedics
- Vol. 41 (3) , 475-480
Dual-mobility cup in total hip arthroplasty in patients less than fifty five years and over ten years of follow-up
We report clinical and radiological outcome of a dual mobility cup (DMC) of 2nd generation after a minimum of ten year-follow-up (FU). The goal of this work was to compare the results of this DMC in patients aged less than 55 years and in patients aged more than 55 years. From 2000 to 2005, a prospective and consecutive series of 119 THAs with a cementless DMC of 2nd generation (GIROS) were performed in patients aged less than 55 years and 444 in patients aged more than 55 years. The mean FU was 11 years (8 to 15 years). Survivorships (failure of both components or cup loosening) were not different between patients aged less than 55 years and patients aged more than 55 years. There was no dislocation. DEVANE classification, Harris, PMA and Oxford scores improved after THA but no difference could be found between between < 55 years and > 55 years patients. These results are better than those of first generation (BOUSQUET) DMC (77 % of survival rate at 20 years of FU). These results are in the same agreement than those of the literature: 99 % of survival rate at 14.2 years of FU for KERBOULL with a low friction arthroplasty and 96.5 % at ten years of FU for ceramic/ceramic bearing (R CHANA). The DMC for young patient is a relevant surgical option with no dislocation and excellent clinical results and survival rate at more than ten years of FU.
- 9 August 2016
- Published by Springer Nature in International Orthopaedics
- Vol. 40 (12) , 2527-2531
Patellar height assessment in total knee arthroplasty: a new method
Introduction We described in 1981 a method to evaluate patellar height in normal and symptomatic knees on sagittal X-ray view. This index is a frequently used method, yet it is not suitable after a total knee arthroplasty (TKA). Material and method The original method measures the distance between the distal margin of the articular surface of the patella (point A) and the anterosuperior angle of the tibial plateau (point T), then the length of the patellar articular surface (AP). The index is AT/AP ratio (normal values range from 0.8 to 1.2). After TKA, the T landmark is no longer available, so we must define a new T’ landmark. This point is situated at the intersection between the line perpendicular to the tibial posterior cortex elevated at the tip of the fibular head and the tibial anterior cortex. This remarkable landmark can be identified before and after TKA, with a new relative index AT’/AP ratio. This modified method allows the comparison of patella height before and after TKA. Results We have used this modified index with the collaboration of several authors during the testing of different models of TKA, with an accurate reproducibility. Repeatability (usually called intra-observer reliability) was good, with intra-class correlation coefficients (ICCs) between 0.58 and 0.75 among the observers. Reproducibility (usually called inter-observer reliability) was also considered as good, with ICC ranging from 0.64 to 0.72. Discussion Patella height measurement has to be assessed with the original method (AT/AP) to detect patella infera that could influence the surgical approach. The correlation between original and modified indexes has to be assessed. The modification of patella height after TKA could be evaluated through the modified index and compared with functional results.
- 9 August 2016
- Published by Springer Nature in International Orthopaedics
- Vol. 40 (12) , 2527-2531
Patellar height assessment in total knee arthroplasty: a new method
Introduction We described in 1981 a method to evaluate patellar height in normal and symptomatic knees on sagittal X-ray view. This index is a frequently used method, yet it is not suitable after a total knee arthroplasty (TKA). Material and method The original method measures the distance between the distal margin of the articular surface of the patella (point A) and the anterosuperior angle of the tibial plateau (point T), then the length of the patellar articular surface (AP). The index is AT/AP ratio (normal values range from 0.8 to 1.2). After TKA, the T landmark is no longer available, so we must define a new T’ landmark. This point is situated at the intersection between the line perpendicular to the tibial posterior cortex elevated at the tip of the fibular head and the tibial anterior cortex. This remarkable landmark can be identified before and after TKA, with a new relative index AT’/AP ratio. This modified method allows the comparison of patella height before and after TKA. Results We have used this modified index with the collaboration of several authors during the testing of different models of TKA, with an accurate reproducibility. Repeatability (usually called intra-observer reliability) was good, with intra-class correlation coefficients (ICCs) between 0.58 and 0.75 among the observers. Reproducibility (usually called inter-observer reliability) was also considered as good, with ICC ranging from 0.64 to 0.72. Discussion Patella height measurement has to be assessed with the original method (AT/AP) to detect patella infera that could influence the surgical approach. The correlation between original and modified indexes has to be assessed. The modification of patella height after TKA could be evaluated through the modified index and compared with functional results.
- 14 December 2015
- Published by Springer Nature in International Orthopaedics
- Vol. 41 (3) , 455-459
Causes for revision of dual-mobility and standard primary total hip arthroplasty
The causes for revision of primary total hip arthroplasty (THA) are various and quite well known. The developing use of dual-mobility THA (DM-THA) seems a relevant option to decrease the risk of instability. Due to lack of long-term follow-up, this innovative retentive concept is suspected to increase the risk of polyethylene (PE) wear. the aim of the study was to analyse the causes for DM-THA revision and assess whether or not its occurrence is different from that of fixed-standard (FS) THA , particularly for aseptic loosening or wear and/or osteolysis. The SoFCOT group conducted an observational prospective multicentre study from 1 January 2010 to 31 December 2011. Inclusion criteria comprised an exhaustive collection of 2044 first-revision THAs with 251 DM-THAs and 1793 FS-THAs. After excluding complications linked to patient factors (infection and periprosthetic fractures), we performed a matched case–control study (matching ratio 1:1) comparing two groups of 133 THAs. Revisions for aseptic loosening or osteolysis/wear were as frequent in DM-THA (58.7 %) as in FS-THA (57.1 %) (p 0.32); 7.5 % of DM-THA were revised for dislocation versus 19.5 % of FS-THA (p 0.007). Revision for osteolysis/wear and aseptic loosening were as frequent in DM-THA as in FS-THA; revision for dislocation was less frequent in DM-THA. This confirms the efficiency of the DM concept regarding the risk of dislocation. Causes for revision were different between groups, and revisions for dislocation were less frequent in DM-THA. Only prospective comparative studies could provide reliable information that may support broader use of the DM concept.
- 14 December 2015
- Published by Springer Nature in International Orthopaedics
- Vol. 41 (3) , 455-459
Causes for revision of dual-mobility and standard primary total hip arthroplasty
The causes for revision of primary total hip arthroplasty (THA) are various and quite well known. The developing use of dual-mobility THA (DM-THA) seems a relevant option to decrease the risk of instability. Due to lack of long-term follow-up, this innovative retentive concept is suspected to increase the risk of polyethylene (PE) wear. the aim of the study was to analyse the causes for DM-THA revision and assess whether or not its occurrence is different from that of fixed-standard (FS) THA , particularly for aseptic loosening or wear and/or osteolysis. The SoFCOT group conducted an observational prospective multicentre study from 1 January 2010 to 31 December 2011. Inclusion criteria comprised an exhaustive collection of 2044 first-revision THAs with 251 DM-THAs and 1793 FS-THAs. After excluding complications linked to patient factors (infection and periprosthetic fractures), we performed a matched case–control study (matching ratio 1:1) comparing two groups of 133 THAs. Revisions for aseptic loosening or osteolysis/wear were as frequent in DM-THA (58.7 %) as in FS-THA (57.1 %) (p 0.32); 7.5 % of DM-THA were revised for dislocation versus 19.5 % of FS-THA (p 0.007). Revision for osteolysis/wear and aseptic loosening were as frequent in DM-THA as in FS-THA; revision for dislocation was less frequent in DM-THA. This confirms the efficiency of the DM concept regarding the risk of dislocation. Causes for revision were different between groups, and revisions for dislocation were less frequent in DM-THA. Only prospective comparative studies could provide reliable information that may support broader use of the DM concept.
- Open Access
- 5 June 2015
- Published by EDP Sciences in SICOT-J
- Vol. 1, 7
Trans trochanteric approach with coronal osteotomy of the great trochanter
SICOT-J, official journal of the Société Internationale de Chirurgie Orthopédique et de Traumatologie (SICOT)
- 5 June 2015
- Published by EDP Sciences in SICOT-J
- Vol. 1, 7
Open AccessTrans trochanteric approach with coronal osteotomy of the great trochanter
SICOT-J, official journal of the Société Internationale de Chirurgie Orthopédique et de Traumatologie (SICOT)