JPJean Louis Prudhon

Jean Louis Prudhon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jean Louis Prudhon has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Revision of a Monoblock Metal-on-Metal Cup Using a Dual Mobility Component: Is It a Reasonable Option?

    by Saverio Affatato, Emanuela Castiello, Luca Amendola, Saverio Comitini, Jean Louis Prudhon, Domenico Tigani

    Revision of large-diameter, monoblock acetabular components for both hip resurfacing arthroplasty and metal-on-metal (MoM) total hip arthroplasty (THA) is correlated to a high amount of complications. For this reason, performing a limited revision by conversion to a dual mobility (DM) without acetabular component exchange has been proposed in order to limit these complications. Although DM bearing offers an easy solution avoiding the intraoperative and time-associated complications, concern about polyethylene wear and stability remains due to the difference regarding the design, the coverage angle and the clearance of the two implants. In order to evaluate the performance of this new solution with the new material to prevent the possibility of failure it is essential to conduct a review of the literature A qualitative systematic review of the literature has been conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A comprehensive search of PubMed, EMBASE, Google Scholar, and Scopus for English and French articles between January 2000 and October 2019 was performed, with the primary objective of finding articles about dual mobility bearing coupling with large metal-on-metal cup in the case of hip revision procedure. Various combinations of the key words were used in the search strategy. Thirteen articles with DM bearing mated with MoM cup were analyzed. Of the 130 hip revisions selected, with a follow-up from 6 to 53 months, there were a total of 14 with complications (10.77%): four true dislocations (3.08%); six intra-prosthetic dislocations (IPD, 4.6%), two of which presented plastic deformation and polyethylene wear; four other complications (3.08%), included a cup osteolysis, a clicking noise, a superficial infection and a periprosthetic fracture. All the mentioned true dislocations occurred during the first month while IPDs appeared during the first two years from the index revision. In conclusion, according to the literature analyzed, we can stress that the concerns and doubts about mating a DM bearing with large MoM cup cannot be dissolved. It has been pointed out that a DM bearing is not designed for a MoM cup; it is not mechanically tested on MoM cups, which presents different clearance and coverage angles. Predictable complications may occur, such as IPD, polyethylene wear and true dislocation. These complications have been reported at an even higher rate than they were in the eighties, when the first generation of DM implants were of a lower quality of polyethylene and the characteristic of the design was less optimal than modern ones.


  • Open Access

    Letter to the editor on “Asymptomatic intraprosthetic dual mobility cup dislocation with increased metal ion levels”

    by Emanuela Castiello, Luca Amendola, Paolo Barca, Domenico Tigani, Jacques H. Caton, Thomas Neri, Jean Louis Prudhon


  • Open Access

    Charnley femoral cemented stem with a permeable and resorbable cement restrictor and low-viscosity cement

    by Jean-Louis Prudhon, Jacques H. Caton, Thierry Aslanian

    Introduction: In 1979, in his first book dealing with low-friction arthroplasty (LFA), Charnley highlighted the use of a cement restrictor. Breusch and Malchau described in 2005 the “second-generation cementing technique.” The main objective of this study was to report on the clinical survival of 100 cases of Charnley femoral component implanted in 2007 and 2008 using a permeable and resorbable cement restrictor and a low-viscosity antibiotic-loaded cement. The secondary objectives were to analyze the complications and side effects and the accuracy of the device positioning. Material and methods: This was a monocentric retrospective review of a prospectively compiled database. Diaphyseal restrictor was biodegradable and permeable to gas, blood, and fluids to avoid intramedullary over pression during cementation. The cement was a low-viscosity antibiotic-loaded cement. Among 3555 patients, we selected the first continuous 100 cases of patients where we implanted the device. Survival probability was computed according to Kaplan–Meier method. Results: Mean follow-up was 6.55 ± 2.6 (range 1–11). Considering femoral component revision as the endpoint, survival rate was 100%. No patients died intraoperatively, none in the first month and the first year after surgery. No early periprosthetic fractures have been reported. Discussion: As described initially by Charnley, the use of a cement restrictor was highly recommended through the different generations of cementing techniques. Hypotensive episodes and cardiac arrest have been reported during cement insertion. In our series, we did not deplore any adverse effect related to the cementation. Conclusion: Our study demonstrates a 100% survival rate of a cemented femoral component without adverse effects when using routinely a resorbable and permeable cement restrictor and a low-viscosity cement. Bone cement is still a fantastic ally for the surgeon and the patients.


  • Open Access

    Letter to the editor on “Catastrophic failure of a dual mobility bearing in a revision total hip arthroplasty”

    by Jean Louis Prudhon, Domenico Tigani, Thomas Neri, André Ferreira, Jean Alain Epinette, Michel H. Fessy, Jacques H. Caton


  • Primary cementless total knee arthroplasty with or without stem extension: a matched comparative study of ninety eight standard stems versus ninety eight long stems after more than ten years of follow-up

    by Jean-Louis Prudhon, Régis Verdier, Jacques H. Caton

    Using a cementless fixation for total knee arthroplasty (TKA) is controversial. We hypothesized that cementless tibial base plate with a monoblock long stem (MLS) would provide secure tibial alignment and stable fixation when bone conditions were considered as poor for a cementless fixation. The purpose of this study was to compare the mean eight year survivorship of cementless standard keels (SK) vs cementless MLS.


  • Open Access

    Extended trochanteric osteotomy: comparison of 3 modes of fixation: metallic wires, cables, plate, about a series of 157 cases

    by Jean Louis Prudhon, Nicolas Tardy

    Introduction: The trans femoral osteotomy was initially described by Wagner in 1987 and the extended trochanteric osteotomy (ETO) was described by Younger et al. in 1995 and is considered to be the gold standard technique for removal of well-fixed femoral stems in revision total hip arthroplasty (THA). The purpose of this report is: to compare the different types of fixation metallic wires, cables, metallic reinforcement plate (MRP) we have used in revision THA where an ETO was performed; analyse the clinical and radiological outcomes of these devices at 1 year; analyse the complication. Materialand method: It is a retrospective continuous monocentric series of 157 patients where an ETO was performed. It was fixed by an MRP in 17 patients, cables in 43, metallic wires in 97. The main outcome was the consolidation of the osteotomized femoral flap (OFF). Secondary outcomes were Postel Merle d’Aubigne score and complications occurred at 1 year follow up. Qualitative variable was presented as percentage, quantitative variables as mean or median, standard deviation and range.Result: 157 patients (73−46, 5% females) were included. Mean age at surgery was 66.7 year (sd = 10.63). Mean interval between index surgery and revision was 11.07 year (sd = 5.67). Causes for revision and bone defects were comparable. At 1 year OFF is healed without displacement in 82% with metallic wires, 70% with cables, 88% with MRP. Not significant.Discussion: Fixation of the femoral flap is a technical issue in ETO. Metallic wires and cables are the most commonly used to secure the fixation. Fixation with a metallic plate is reported in a few number of articles and may be helpful specially when a fracture of the OFF occurred during surgery.


  • Open Access

    Letter to the editor on “Early intraprosthetic dislocation in dual-mobility implants: a systematic review”

    by Domenico Tigani, Jean Louis Prudhon, Luca Amendola, Thierry Aslanian


  • Open Access

    Cemented or cementless total knee arthroplasty?

    by Jean-Louis Prudhon, Régis Verdier

    Introduction: Since 1996 we have been using cementless fixation with hydroxyapatite (HA) coating. The purpose of this paper is to compare survivorship of a series of 100 cemented Total Knee Arthroplasty (TKA) to a similar series of 100 cementless with a follow up of 11–16 years. Material methods: Both TKA are mobile bearing total knee postero-stabilized. They can be used with cement or without cement. Among 1030 New Wave TKATM implanted from 2002 to 2015 we have identified 100 cemented TKAs and 100 cementless TKAs. All these cases were primary replacement. Differences in survival probability were determined using log-rank test. Results: Survival probabilities at 11 years of follow-up were: Cemented group: 90.2% CI95% [81.9–94.8]; Cementless group: 95.4% CI95% [88.1–98.2]. Comparison between both group showed significant difference, p = 0.32. Discussion: The advantages of cementless TKA are bone stock preservation, cement debris protection and the potential to achieve biologic fixation. Cementless implants rely on a porous or roughened surface to facilitate bone formation. HA has been shown to accelerate bone integration and to decrease micro motion of the components and to increase fixation. With a survival probability of 90.2% (cemented version) and 95.4% (cementless version), this total knee prosthesis performs as intended in primary total knee arthroplasty. No statistical differences could be found between cemented and cementless implants.


  • How is patella height modified after total knee arthroplasty?

    by Jean Louis Prudhon, Jacques H. Caton, Thierry Aslanian, Régis Verdier

    Since the first measurement method of patella height in 1929 (Janssen), more than 16 methods have been described. Most of these measures are not suitable to measure patella height after total knee arthroplasty (TKA). One of us (JC) modified the original Caton Deschamps (oCD), index with a new relative index called modified Caton Deschamps (mCD) index, by using new landmarks. The purpose of this study was to determine how patella height is modified after TKA.


  • Is dual mobility associated with an increased risk of revision for infection? Matched cohort of 231 cases of dual-mobility cups and 231 fixed cups

    by Jean Louis Prudhon, Romain Desmarchelier, Moussa Hamadouche, Christian Delaunay, Regis Verdier

    Introduction: We used a matched cohort of 231 cases of revision of primary dual-mobility cups (DMC) total hip arthroplasty (THA) and 231 cases of fixed cups (FC) THA, to determine whether (i) revision for infection was more frequent when using DMC-THA than FC-THA; (ii) Causes for revision were significantly different. Methods: The French Society of Orthopaedics and Traumatology carried out a prospective multicentre study from 2010 to 2011. The inclusion criterion was an exhaustive collection of 1st revision THA (at least 1 component revised, re-revision excluded). 2,044 1st revision cases were prospectively collected; 251 (13.5%) were revision of DMC-THA and 1,793 were revision of FC-THA (87.7%). We defined a matching process (1:1) between the 2 cohorts. 231 DMC-THAs were eligible for comparison with 231 FC-THAs. Results: 47 (20.3%) FC-THAs were revised for infection and 54 (23.3%) DMC-THAs. There was no statistical difference (p = 0.43). 41 (17.7%) FC-THAs were revised for dislocation, compared to 11 (4.7%) DMC-THAs (p<0.001). Discussion: The main finding of our study was that DMC was not associated with an increased risk of revision for infection compared to standard THA. THA revision for infection was not correlated to the type of cup used. It is mandatory to report on comparable types of patients when comparing outcomes. For similar patient profiles (i) DMC-THAs were not revised more often for infection than FC-THA (ii) FC-THAs were revised 4 times more for dislocation than DMC-THA.