MVMartin Vitek

Martin Vitek

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Martin Vitek has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Brno University of Technology Smartphone PPG Database (BUT PPG): Annotated Dataset for PPG Quality Assessment and Heart Rate Estimation

    by Andrea Nemcova, Enikö Vargova, Radovan Smisek, Lucie Marsanova, Lukas Smital, Martin Vitek

    To the best of our knowledge, there is no annotated database of PPG signals recorded by smartphone publicly available. This article introduces Brno University of Technology Smartphone PPG Database (BUT PPG) which is an original database created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, for the purpose of evaluating photoplethysmographic (PPG) signal quality and estimation of heart rate (HR). The data comprises 48 10‐second recordings of PPGs and associated electrocardiographic (ECG) signals used for determination of reference HR. The data were collected from 12 subjects (6 female, 6 male) aged between 21 and 61. PPG data were collected by smartphone Xiaomi Mi9 with sampling frequency of 30 Hz. Reference ECG signals were recorded using a mobile ECG recorder (Bittium Faros 360) with a sampling frequency of 1,000 Hz. Each PPG signal includes annotation of quality created manually by biomedical experts and reference HR. PPG signal quality is indicated binary: 1 indicates good quality for HR estimation, 0 indicates signals where HR cannot be detected reliably, and thus, these signals are unsuitable for further analysis. As the only available database containing PPG signals recorded by smartphone, BUT PPG is a unique tool for the development of smart, user‐friendly, cheap, on‐the‐spot, self‐home‐monitoring of heart rate with the potential of widespread using.


  • Real-Time Quality Assessment of Long-Term ECG Signals Recorded by Wearables in Free-Living Conditions

    by Lukas Smital, Clifton R. Haider, Martin Vitek, Pavel Leinveber, Pavel Jurak, Andrea Nemcova, Radovan Smisek, Lucie Marsanova, Ivo Provaznik, Christopher L. Felton, et al.

    Nowadays, methods for ECG quality assessment are mostly designed to binary distinguish between good/bad quality of the whole signal. Such classification is not suitable to long-term data collected by wearable devices. In this paper, a novel approach to estimate long-term ECG signal quality is proposed. The real-time quality estimation is performed in a local time window by calculation of continuous signal-to-noise ratio (SNR) curve. The layout of the data quality segments is determined by analysis of SNR waveform. It is distinguished between three levels of ECG signal quality: signal suitable for full wave ECG analysis, signal suitable only for QRS detection, and signal unsuitable for further processing. The SNR limits for reliable QRS detection and full ECG waveform analysis are 5 and 18 dB respectively. The method was developed and tested using synthetic data and validated on real data from wearable device. The proposed solution is a robust, accurate and computationally efficient algorithm for annotation of ECG signal quality that will facilitate the subsequent tailored analysis of ECG signals recorded in free-living conditions. The field of long-term ECG signals self-monitoring by wearable devices is swiftly developing. The analysis of massive amount of collected data is time consuming. It is advantageous to characterize data quality in advance and thereby limit consequent analysis to useable signals.


  • Open Access

    Rapid Bacterial Species Delineation Based on Parameters Derived From Genome Numerical Representations

    by Denisa Maderankova, Robin Jugas, Karel Sedlar, Martin Vitek, Helena Skutkova

    Species delineation based on bacterial genomes is an essential part of the research of prokaryotes. In silico genome-to-genome comparison methods are computationally demanding, but much less tedious and error prone than the wet-lab methods. In this paper, we present a novel method for the delineation of bacterial genomes based on genomic signal processing. The proposed method uses numerical representations of whole bacterial genomes, phase signal and cumulated phase signal, from which four parameters are derived for each genome. The parameters characterize a genome and their calculation is independent of the other genomes comprising a delineation dataset. The delineation itself is processed as a calculation of the parameters' average similarity. The method was statistically verified on 1826 bacterial genomes. A similarity threshold of 96% was set based on the receiver operating characteristic curve that featured sensitivity of 99.78% and specificity of 97.25%. Additionally, comparative analysis on another 33 bacterial genomes was conducted using standard delineation tools as these tools were not able to process the dataset of 1826 genomes using desktop computer. The proposed method achieved comparable or better delineation results in comparison with the standard tools. Besides the excellent delineation results, another great advantage of the method is its small computational demands, which enables the delineation of thousands of genomes on a desktop computer. The calculation of the parameters takes tens of minutes for thousands of genomes. Moreover, they can be calculated in advance by creating a database, meaning the delineation itself is then completed in a matter of seconds.


  • Open Access

    A degeneration-reducing criterion for optimal digital mapping of genetic codes

    by Helena Skutkova, Denisa Maderankova, Karel Sedlar, Robin Jugas, Martin Vitek

    Bioinformatics may seem to be a scientific field processing primarily large string datasets, as nucleotides and amino acids are represented with dedicated characters. On the other hand, many computational tasks that bioinformatics challenges are mathematical problems understandable as operations with digits. In fact, many computational tasks are solved this way in the background. One of the most widely used digital representations is mapping of nucleotides and amino acids with integers 0-3 and 0-20, respectively. The limitation of this mapping occurs when the digital signal of nucleotides has to be translated into a digital signal of amino acids as the genetic code is degenerated. This causes non-monotonies in a mapping function. Although map for reducing this undesirable effect has already been proposed, it is defined theoretically and for standard genetic codes only. In this study, we derived a novel optimal criterion for reducing the influence of degeneration by utilizing a large dataset of real sequences with various genetic codes. As a result, we proposed a new robust global optimal map suitable for any genetic code as well as specialized optimal maps for particular genetic codes.


  • Multi-stage SVM approach for cardiac arrhythmias detection in short single-lead ECG recorded by a wearable device

    by Radovan Smisek, Jakub Hejc, Marina Ronzhina, Andrea Nemcova, Lucie Marsanova, Jana Kolarova, Lukas Smital, Martin Vitek

    Objective : Use of wearable ECG devices for arrhythmia screening is limited due to poor signal quality, small number of leads and short records, leading to incorrect recognition of pathological events. This paper introduces a novel approach to classification (normal/‘N’, atrial fibrillation/‘A’, other/‘O’, and noisy/‘P’) of short single-lead ECGs recorded by wearable devices. Approach : Various rhythm and morphology features are derived from the separate beats (‘local’ features) as well as the entire ECGs (‘global’ features) to represent short-term events and general trends respectively. Various types of atrial and ventricular activity, heart beats and, finally, ECG records are then recognised by a multi-level approach combining a support vector machine (SVM), decision tree and threshold-based rules. Main results : The proposed features are suitable for the recognition of ‘A’. The method is robust due to the noise estimation involved. A combination of radial and linear SVMs ensures both high predictive performance and effective generalisation. Cost-sensitive learning, genetic algorithm feature selection and thresholding improve overall performance. The generalisation ability and reliability of this approach are high, as verified by cross-validation on a training set and by blind testing, with only a slight decrease of overall F1-measure, from 0.84 on training to 0.81 on the tested dataset. ‘O’ recognition seems to be the most difficult (test F1-measures: 0.90/‘N’, 0.81/‘A’ and 0.72/‘O’) due to high inter-patient variability and similarity with ‘N’. Significance : These study results contribute to multidisciplinary areas, focusing on creation of robust and reliable cardiac monitoring systems in order to improve diagnosis, reduce unnecessary time-consuming expert ECG scoring and, consequently, ensure timely and effective treatment.


  • Assessment of ECG Signal Quality After Compression

    by Andrea Němcová, Martin Vítek, Lucie Maršánová, Radovan Smíšek, Lukáš Smital

  • Automatic Detection of P Wave in ECG During Ventricular Extrasystoles

    by Lucie Maršánová, Andrea Němcová, Radovan Smíšek, Tomáš Goldmann, Martin Vítek, Lukáš Smital


  • Open Access

    ECG features and methods for automatic classification of ventricular premature and ischemic heartbeats: A comprehensive experimental study

    by Lucie Maršánová, Marina Ronzhina, Radovan Smíšek, Martin Vítek, Andrea Němcová, Lukas Smital, Marie Nováková

    Accurate detection of cardiac pathological events is an important part of electrocardiogram (ECG) evaluation and subsequent correct treatment of the patient. The paper introduces the results of a complex study, where various aspects of automatic classification of various heartbeat types have been addressed. Particularly, non-ischemic, ischemic (of two different grades) and subsequent ventricular premature beats were classified in this combination for the first time. ECGs recorded in rabbit isolated hearts under non-ischemic and ischemic conditions were used for analysis. Various morphological and spectral features (both commonly used and newly proposed) as well as classification models were tested on the same data set. It was found that: a) morphological features are generally more suitable than spectral ones; b) successful results (accuracy up to 98.3% and 96.2% for morphological and spectral features, respectively) can be achieved using features calculated without time-consuming delineation of QRS-T segment; c) use of reduced number of features (3 to 14 features) for model training allows achieving similar or even better performance as compared to the whole feature sets (10 to 29 features); d) k-nearest neighbours and support vector machine seem to be the most appropriate models (accuracy up to 98.6% and 93.5%, respectively).


  • CSE database: extended annotations and new recommendations for ECG software testing

    by Radovan Smíšek, Lucie Maršánová, Andrea Němcová, Martin Vítek, Jiří Kozumplík, Marie Nováková

    Nowadays, cardiovascular diseases represent the most common cause of death in western countries. Among various examination techniques, electrocardiography (ECG) is still a highly valuable tool used for the diagnosis of many cardiovascular disorders. In order to diagnose a person based on ECG, cardiologists can use automatic diagnostic algorithms. Research in this area is still necessary. In order to compare various algorithms correctly, it is necessary to test them on standard annotated databases, such as the Common Standards for Quantitative Electrocardiography (CSE) database. According to Scopus, the CSE database is the second most cited standard database. There were two main objectives in this work. First, new diagnoses were added to the CSE database, which extended its original annotations. Second, new recommendations for diagnostic software quality estimation were established. The ECG recordings were diagnosed by five new cardiologists independently, and in total, 59 different diagnoses were found. Such a large number of diagnoses is unique, even in terms of standard databases. Based on the cardiologists’ diagnoses, a four-round consensus (4R consensus) was established. Such a 4R consensus means a correct final diagnosis, which should ideally be the output of any tested classification software. The accuracy of the cardiologists’ diagnoses compared with the 4R consensus was the basis for the establishment of accuracy recommendations. The accuracy was determined in terms of sensitivity = 79.20–86.81%, positive predictive value = 79.10–87.11%, and the Jaccard coefficient = 72.21–81.14%, respectively. Within these ranges, the accuracy of the software is comparable with the accuracy of cardiologists. The accuracy quantification of the correct classification is unique. Diagnostic software developers can objectively evaluate the success of their algorithm and promote its further development. The annotations and recommendations proposed in this work will allow for faster development and testing of classification software. As a result, this might facilitate cardiologists’ work and lead to faster diagnoses and earlier treatment.


  • Open Access

    Set of rules for genomic signal downsampling

    by Karel Sedlar, Helena Skutkova, Martin Vitek, Ivo Provaznik