Real-Time Quality Assessment of Long-Term ECG Signals Recorded by Wearables in Free-Living Conditions
Authors:
- Lukas SmitalLSLukas Smital
- Clifton R. HaiderCHClifton R. Haider
- Martin VitekMVMartin Vitek
- Pavel LeinveberPLPavel Leinveber
- Pavel JurakPJPavel Jurak
- Andrea NemcovaANAndrea Nemcova
- Radovan SmisekRSRadovan Smisek
- Lucie MarsanovaLMLucie Marsanova
- Ivo ProvaznikIvo Provaznik
- Christopher L. FeltonCFChristopher L. Felton
- Barry K. GilbertBGBarry K. Gilbert
- David R. HolmesDHDavid R. Holmes
- 27 January 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (10) , 2721-2734
Abstract
Nowadays, methods for ECG quality assessment are mostly designed to binary distinguish between good/bad quality of the whole signal. Such classification is not suitable to long-term data collected by wearable devices. In this paper, a novel approach to estimate long-term ECG signal quality is proposed. The real-time quality estimation is performed in a local time window by calculation of continuous signal-to-noise ratio (SNR) curve. The layout of the data quality segments is determined by analysis of SNR waveform. It is distinguished between three levels of ECG signal quality: signal suitable for full wave ECG analysis, signal suitable only for QRS detection, and signal unsuitable for further processing. The SNR limits for reliable QRS detection and full ECG waveform analysis are 5 and 18 dB respectively. The method was developed and tested using synthetic data and validated on real data from wearable device. The proposed solution is a robust, accurate and computationally efficient algorithm for annotation of ECG signal quality that will facilitate the subsequent tailored analysis of ECG signals recorded in free-living conditions. The field of long-term ECG signals self-monitoring by wearable devices is swiftly developing. The analysis of massive amount of collected data is time consuming. It is advantageous to characterize data quality in advance and thereby limit consequent analysis to useable signals.Keywords
Funding Information
- United States Office of Naval Research Global (N62909-19-1-2006)
- National Program of Sustainability II (LQ1605)
This publication has 40 references indexed in Scilit:
- Signal quality measures for pulse oximetry through waveform morphology analysisPhysiological Measurement, 2011
- Novel therapeutic concepts * The epidemic of cardiovascular disease in the developing world: global implicationsEuropean Heart Journal, 2010
- Artificial arterial blood pressure artifact models and an evaluation of a robust blood pressure and heart rate estimatorBioMedical Engineering OnLine, 2009
- P wave detector with PP rhythm tracking: evaluation in different arrhythmia contextsPhysiological Measurement, 2008
- Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filterPhysiological Measurement, 2007
- A dynamical model for generating synthetic electrocardiogram signalsIEEE Transactions on Biomedical Engineering, 2003
- A novel algorithm for cardiac biosignal filtering based on filtered residue methodIEEE Transactions on Biomedical Engineering, 2002
- A novel approach for precise simulation of the EMG signal detected by surface electrodesIEEE Transactions on Biomedical Engineering, 2001
- Automatic Detection of Wave Boundaries in Multilead ECG Signals: Validation with the CSE DatabaseComputers and Biomedical Research, 1994
- Establishment of a reference library for evaluating computer ECG measurement programsComputers and Biomedical Research, 1985