Ahsan Javed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahsan Javed has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Adrienne E. Campbell-Washburn
Cardiovascular Branch, Division of Intramural Research National Heart, Lung, and Blood Institute, National Institutes of Health Bethesda Maryland USA
9 shared publications - Krishna Shrinivas Nayak
Ming Hsieh Department of Electrical and Computer Engineering Viterbi School of Engineering, University of Southern California Los Angeles California USA
8 shared publications Rajiv Ramasawmy
Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute National Institutes of Health Bethesda Maryland USA
5 shared publications- Rajiv Ramasawmy
Cardiovascular Branch, Division of Intramural Research National Heart, Lung & Blood Institute, NIH Bethesda Maryland USA
4 shared publications Pan Su
Siemens Medical Solutions USA Malvern Pennsylvania USA
3 shared publications- Pierre Daudé
Laboratory of Imaging Technology, Cardiovascular Branch, Division of Intramural Research National Heart, Lung & Blood Institute, NIH Bethesda Maryland USA
3 shared publications
Latest Publications
- Open Access
- 28 July 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (5) , 2213-2227
“Two‐For‐One”: 4D Cardiac and Pulmonary MR Imaging From a Single Acquisition Using bSTAR
Purpose: To generate 4D (3D+time) images of both the heart and lungs using a single volumetric radial free‐breathing bSSFP dual echo acquisition (bSTAR) with two image reconstructions within a single pipeline deployed inline at 0.55 and 1.5 T. Methods: 10 healthy volunteers and 12 patients with cardiomyopathy, lung diseases, or pulmonary hypertension were imaged at 0.55 T. Left‐ventricular volumetry was compared to 2D cine images for the cardiac images. Image quality score was measured by two expert readers for cardiac and pulmonary bSTAR images. Results: Cardiac and pulmonary images were reconstructed inline in 18 min 28 s and 8 min 39 s respectively. Ejection Fraction measurements showed no significant difference (mean bias −0.39%, p > 0.05) between bSTAR and 2D cines. Experts scored whole heart bSTAR images fair‐to‐good (image quality score of 3.47 ± 0.58) and whole lung bSTAR images as good (image quality score of 3.94 ± 0.85). Conclusion: The ability to assess both cardiac and lung morphology and function in a single scan with parallel image reconstructions will facilitate the evaluation of the cardio‐pulmonary interplay. Trial Registration: ClinicalTrials.gov identifier: NCT03331380
- 28 July 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (5) , 2213-2227
Open Access“Two‐For‐One”: 4D Cardiac and Pulmonary MR Imaging From a Single Acquisition Using bSTAR
Purpose: To generate 4D (3D+time) images of both the heart and lungs using a single volumetric radial free‐breathing bSSFP dual echo acquisition (bSTAR) with two image reconstructions within a single pipeline deployed inline at 0.55 and 1.5 T. Methods: 10 healthy volunteers and 12 patients with cardiomyopathy, lung diseases, or pulmonary hypertension were imaged at 0.55 T. Left‐ventricular volumetry was compared to 2D cine images for the cardiac images. Image quality score was measured by two expert readers for cardiac and pulmonary bSTAR images. Results: Cardiac and pulmonary images were reconstructed inline in 18 min 28 s and 8 min 39 s respectively. Ejection Fraction measurements showed no significant difference (mean bias −0.39%, p > 0.05) between bSTAR and 2D cines. Experts scored whole heart bSTAR images fair‐to‐good (image quality score of 3.47 ± 0.58) and whole lung bSTAR images as good (image quality score of 3.94 ± 0.85). Conclusion: The ability to assess both cardiac and lung morphology and function in a single scan with parallel image reconstructions will facilitate the evaluation of the cardio‐pulmonary interplay. Trial Registration: ClinicalTrials.gov identifier: NCT03331380
- Open Access
- 7 November 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (4) , 2241-2253
Coil Sketching for Fast and Efficient 4D Lung MRI Reconstruction
Purpose: To develop and evaluate a memory‐efficient and accelerated reconstruction framework for respiratory‐resolved 4D lung MRI using coil sketching and Toeplitz approximation, enabling high‐quality motion‐compensated low‐rank (MoCo‐LR) reconstructions on clinically accessible GPU hardware. Theory and Methods: Respiratory‐resolved 4D MRI enables non‐invasive assessment of pulmonary structure and function but is limited by computational and memory demands from large matrices and long acquisitions. We extend the coil sketching framework—previously proposed for 3D imaging—to 4D (3D + time), allowing the data consistency term of compressed‐sensing objective functions to be solved with reduced GPU memory consumption and reconstruction duration while preserving image accuracy. Additionally, we implement Toeplitz approximation to accelerate repeated applications of the normal encoding operator, further reducing computational demand. Finally, we outline a MoCo‐LR regularization technique that uses only forward deformations, improving reconstruction stability over many iterations. Reconstructions were performed across several regularization schemes using a 3D stack‐of‐spirals acquisition and evaluated for memory footprint, speed, and image accuracy. Results: The proposed 4D coil sketching method reduced memory usage by ˜3‐fold compared to fully sampled reconstructions and enabled high‐resolution MoCo‐LR reconstructions in < 10 min on < 48 GB GPUs. Toeplitz approximation further reduced runtime with minimal impact on image quality. Compared to conventional coil compression, coil sketching preserved parenchymal signal and structural fidelity in low‐SNR regions. Conclusion: Coil sketching and Toeplitz approximation provide a generalizable, hardware‐efficient solution for 4D lung MRI reconstruction. These methods reduce computational barriers, improve reconstruction speed, and maintain image quality, offering a path toward broader clinical adoption of respiratory‐resolved lung MRI.
- 7 November 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (4) , 2241-2253
Open AccessCoil Sketching for Fast and Efficient 4D Lung MRI Reconstruction
Purpose: To develop and evaluate a memory‐efficient and accelerated reconstruction framework for respiratory‐resolved 4D lung MRI using coil sketching and Toeplitz approximation, enabling high‐quality motion‐compensated low‐rank (MoCo‐LR) reconstructions on clinically accessible GPU hardware. Theory and Methods: Respiratory‐resolved 4D MRI enables non‐invasive assessment of pulmonary structure and function but is limited by computational and memory demands from large matrices and long acquisitions. We extend the coil sketching framework—previously proposed for 3D imaging—to 4D (3D + time), allowing the data consistency term of compressed‐sensing objective functions to be solved with reduced GPU memory consumption and reconstruction duration while preserving image accuracy. Additionally, we implement Toeplitz approximation to accelerate repeated applications of the normal encoding operator, further reducing computational demand. Finally, we outline a MoCo‐LR regularization technique that uses only forward deformations, improving reconstruction stability over many iterations. Reconstructions were performed across several regularization schemes using a 3D stack‐of‐spirals acquisition and evaluated for memory footprint, speed, and image accuracy. Results: The proposed 4D coil sketching method reduced memory usage by ˜3‐fold compared to fully sampled reconstructions and enabled high‐resolution MoCo‐LR reconstructions in < 10 min on < 48 GB GPUs. Toeplitz approximation further reduced runtime with minimal impact on image quality. Compared to conventional coil compression, coil sketching preserved parenchymal signal and structural fidelity in low‐SNR regions. Conclusion: Coil sketching and Toeplitz approximation provide a generalizable, hardware‐efficient solution for 4D lung MRI reconstruction. These methods reduce computational barriers, improve reconstruction speed, and maintain image quality, offering a path toward broader clinical adoption of respiratory‐resolved lung MRI.
- Open Access
- 20 November 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (4) , 1741-1750
Variable‐flip‐angle 3D spiral‐in‐out turbo spin‐echo imaging using concomitant gradient compensation and echo reordering at 0.55 T
Purpose: To develop single‐slab 3D spiral turbo spin echo (spiral SPACE) for 1‐mm 3 isotropic whole‐brain T 2 ‐weighted imaging on a high‐performance 0.55T scanner, with high scan efficiency from interleaved spiral‐in‐out trajectories, variable‐flip‐angle refocusing radiofrequency (RF) pulses, echo reordering, and concomitant‐field compensation. Methods: A stack‐of‐spirals (in‐out waveforms) turbo‐spin‐echo acquisition was implemented with T 2 ‐weighed contrast. Gradient infidelity was corrected using the gradient impulse response function (GIRF), and concomitant‐field compensation was used to correct for phase errors among echoes and during the readout windows. To maintain a long echo train (˜600 ms) within each shot, variable‐flip‐angle refocusing RF pulses were generated using extended‐phase‐graph analysis. An echo‐reordering scheme provided a smooth signal variation along the echo direction in k‐space. Images from spiral SPACE with and without concomitant‐field compensation were compared with those from Cartesian SPACE in phantoms and 6 healthy volunteers. Results: Phantom results demonstrated the improved performance of concomitant‐field correction via sequence‐based modifications and of GIRF–based trajectory estimation. Volunteer data showed that with concomitant‐field correction and echo reordering, system imperfection associated image artifacts and blurring were substantially mitigated in spiral SPACE. Compared with Cartesian SPACE, spiral SPACE had an overall 15%–25% signal‐to‐noise ratio (SNR) improvement in both white matter and gray matter. Conclusion: A 3D spiral‐in‐out SPACE acquisition with variable‐flip‐angles, concomitant‐field compensation, and echo‐reordering was demonstrated at 0.55 T, showing promising gains in SNR, compared with Cartesian SPACE.
- 20 November 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (4) , 1741-1750
Open AccessVariable‐flip‐angle 3D spiral‐in‐out turbo spin‐echo imaging using concomitant gradient compensation and echo reordering at 0.55 T
Purpose: To develop single‐slab 3D spiral turbo spin echo (spiral SPACE) for 1‐mm 3 isotropic whole‐brain T 2 ‐weighted imaging on a high‐performance 0.55T scanner, with high scan efficiency from interleaved spiral‐in‐out trajectories, variable‐flip‐angle refocusing radiofrequency (RF) pulses, echo reordering, and concomitant‐field compensation. Methods: A stack‐of‐spirals (in‐out waveforms) turbo‐spin‐echo acquisition was implemented with T 2 ‐weighed contrast. Gradient infidelity was corrected using the gradient impulse response function (GIRF), and concomitant‐field compensation was used to correct for phase errors among echoes and during the readout windows. To maintain a long echo train (˜600 ms) within each shot, variable‐flip‐angle refocusing RF pulses were generated using extended‐phase‐graph analysis. An echo‐reordering scheme provided a smooth signal variation along the echo direction in k‐space. Images from spiral SPACE with and without concomitant‐field compensation were compared with those from Cartesian SPACE in phantoms and 6 healthy volunteers. Results: Phantom results demonstrated the improved performance of concomitant‐field correction via sequence‐based modifications and of GIRF–based trajectory estimation. Volunteer data showed that with concomitant‐field correction and echo reordering, system imperfection associated image artifacts and blurring were substantially mitigated in spiral SPACE. Compared with Cartesian SPACE, spiral SPACE had an overall 15%–25% signal‐to‐noise ratio (SNR) improvement in both white matter and gray matter. Conclusion: A 3D spiral‐in‐out SPACE acquisition with variable‐flip‐angles, concomitant‐field compensation, and echo‐reordering was demonstrated at 0.55 T, showing promising gains in SNR, compared with Cartesian SPACE.
- 1 September 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (1) , 289-300
T1 and T2 measurements across multiple 0.55T MRI systems using open‐source vendor‐neutral sequences
Purpose: To compare T1 and T2 measurements across commercial and prototype 0.55T MRI systems in both phantom and healthy participants using the same vendor‐neutral pulse sequences, reconstruction, and analysis methods.Methods: Standard spin echo measurements and abbreviated protocol measurements of T1, B1, and T2 were made on two prototype 0.55 T systems and two commercial 0.55T systems using an ISMRM/NIST system phantom. Additionally, five healthy participants were imaged at each system using the abbreviated protocol for T1, B1, and T2 measurement. The phantom measurements were compared to NMR‐based reference measurements to determine accuracy, and both phantom and in vivo measurements were compared to assess reproducibility and differences between the prototype and commercial systems.Results: Vendor‐neutral sequences were implemented across all four systems, and the code for pulse sequences and reconstruction is freely available. For participants, there was no difference in the mean T1 and T2 relaxation times between the prototype and commercial systems. In the phantom, there were no significant differences between the prototype and commercial systems for T1 and T2 measurements using the abbreviated protocol.Conclusion: Quantitative T1 and T2 measurements at 0.55T in phantom and healthy participants are not statistically different across the prototype and commercial systems.
- 1 September 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (1) , 289-300
T1 and T2 measurements across multiple 0.55T MRI systems using open‐source vendor‐neutral sequences
Purpose: To compare T1 and T2 measurements across commercial and prototype 0.55T MRI systems in both phantom and healthy participants using the same vendor‐neutral pulse sequences, reconstruction, and analysis methods.Methods: Standard spin echo measurements and abbreviated protocol measurements of T1, B1, and T2 were made on two prototype 0.55 T systems and two commercial 0.55T systems using an ISMRM/NIST system phantom. Additionally, five healthy participants were imaged at each system using the abbreviated protocol for T1, B1, and T2 measurement. The phantom measurements were compared to NMR‐based reference measurements to determine accuracy, and both phantom and in vivo measurements were compared to assess reproducibility and differences between the prototype and commercial systems.Results: Vendor‐neutral sequences were implemented across all four systems, and the code for pulse sequences and reconstruction is freely available. For participants, there was no difference in the mean T1 and T2 relaxation times between the prototype and commercial systems. In the phantom, there were no significant differences between the prototype and commercial systems for T1 and T2 measurements using the abbreviated protocol.Conclusion: Quantitative T1 and T2 measurements at 0.55T in phantom and healthy participants are not statistically different across the prototype and commercial systems.
- Open Access
- 19 March 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (1) , 173-185
Increasing the scan‐efficiency of pulmonary imaging at 0.55 T using iterative concomitant field and motion‐corrected reconstruction
Purpose: To develop an iterative concomitant field and motion corrected (iCoMoCo) reconstruction for isotropic high‐resolution UTE pulmonary imaging at 0.55 T.Methods: A free‐breathing golden‐angle stack‐of‐spirals UTE sequence was used to acquire data for 8 min with prototype and commercial 0.55 T MRI scanners. The data was binned into 12 respiratory phases based on superior–inferior navigator readouts. The previously published iterative motion corrected (iMoCo) reconstruction was extended to include concomitant field correction directly in the cost function. The reconstruction was implemented within the Gadgetron framework for inline reconstruction. Data were retrospectively reconstructed to simulate scan times of 2, 4, 6, and 8 min. Image quality was assessed using apparent SNR and image sharpness. The technique was evaluated in healthy volunteers and patients with known lung pathology including coronavirus disease 2019 infection, chronic granulomatous disease, lymphangioleiomyomatosis, and lung nodules.Results: The technique provided diagnostic‐quality images, and image quality was maintained with a slight loss in SNR for simulated scan times down to 4 min. Parenchymal apparent SNR was 4.33 ± 0.57, 5.96 ± 0.65, 7.36 ± 0.64, and 7.87 ± 0.65 using iCoMoCo with scan times of 2, 4, 6, and 8 min, respectively. Image sharpness at the diaphragm was comparable between iCoMoCo and reference images. Concomitant field corrections visibly improved the sharpness of anatomical structures away from the isocenter. Inline image reconstruction and artifact correction were achieved in <5 min.Conclusion: The proposed iCoMoCo pulmonary imaging technique can generate diagnostic quality images with 1.75 mm isotropic resolution in less than 5 min using a 6‐min acquisition, on a 0.55 T scanner.
- 19 March 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (1) , 173-185
Open AccessIncreasing the scan‐efficiency of pulmonary imaging at 0.55 T using iterative concomitant field and motion‐corrected reconstruction
Purpose: To develop an iterative concomitant field and motion corrected (iCoMoCo) reconstruction for isotropic high‐resolution UTE pulmonary imaging at 0.55 T.Methods: A free‐breathing golden‐angle stack‐of‐spirals UTE sequence was used to acquire data for 8 min with prototype and commercial 0.55 T MRI scanners. The data was binned into 12 respiratory phases based on superior–inferior navigator readouts. The previously published iterative motion corrected (iMoCo) reconstruction was extended to include concomitant field correction directly in the cost function. The reconstruction was implemented within the Gadgetron framework for inline reconstruction. Data were retrospectively reconstructed to simulate scan times of 2, 4, 6, and 8 min. Image quality was assessed using apparent SNR and image sharpness. The technique was evaluated in healthy volunteers and patients with known lung pathology including coronavirus disease 2019 infection, chronic granulomatous disease, lymphangioleiomyomatosis, and lung nodules.Results: The technique provided diagnostic‐quality images, and image quality was maintained with a slight loss in SNR for simulated scan times down to 4 min. Parenchymal apparent SNR was 4.33 ± 0.57, 5.96 ± 0.65, 7.36 ± 0.64, and 7.87 ± 0.65 using iCoMoCo with scan times of 2, 4, 6, and 8 min, respectively. Image sharpness at the diaphragm was comparable between iCoMoCo and reference images. Concomitant field corrections visibly improved the sharpness of anatomical structures away from the isocenter. Inline image reconstruction and artifact correction were achieved in <5 min.Conclusion: The proposed iCoMoCo pulmonary imaging technique can generate diagnostic quality images with 1.75 mm isotropic resolution in less than 5 min using a 6‐min acquisition, on a 0.55 T scanner.
- Open Access
- 12 March 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 751-760
Inline automatic quality control of 2D phase‐contrast flow MRI for subject‐specific scan time adaptation
Purpose: To develop an inline automatic quality control to achieve consistent diagnostic image quality with subject-specific scan time, and to demonstrate this method for 2D phase-contrast flow MRI to reach a predetermined SNR. Methods: We designed a closed-loop feedback framework between image reconstruction and data acquisition to intermittently check SNR (every 20 s) and automatically stop the acquisition when a target SNR is achieved. A free-breathing 2D pseudo-golden-angle spiral phase-contrast sequence was modified to listen for image-quality messages from the reconstructions. Ten healthy volunteers and 1 patient were imaged at 0.55 T. Target SNR was selected based on retrospective analysis of cardiac output error, and performance of the automatic SNR-driven "stop" was assessed inline. Results: SNR calculation and automated segmentation was feasible within 20 s with inline deployment. The SNR-driven acquisition time was 2 min 39 s +/- 67 s (aorta) and 3 min +/- 80 s (main pulmonary artery) with a min/max acquisition time of 1 min 43 s/4 min 52 s (aorta) and 1 min 43 s/5 min 50 s (main pulmonary artery) across 6 healthy volunteers, while ensuring a diagnostic measurement with relative absolute error in quantitative flow measurement lower than 2.1% (aorta) and 6.3% (main pulmonary artery). Conclusion: The inline quality control enables subject-specific optimized scan times while ensuring consistent diagnostic image quality. The distribution of automated stopping times across the population revealed the value of a subject-specific scan time.
- 12 March 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 751-760
Open AccessInline automatic quality control of 2D phase‐contrast flow MRI for subject‐specific scan time adaptation
Purpose: To develop an inline automatic quality control to achieve consistent diagnostic image quality with subject-specific scan time, and to demonstrate this method for 2D phase-contrast flow MRI to reach a predetermined SNR. Methods: We designed a closed-loop feedback framework between image reconstruction and data acquisition to intermittently check SNR (every 20 s) and automatically stop the acquisition when a target SNR is achieved. A free-breathing 2D pseudo-golden-angle spiral phase-contrast sequence was modified to listen for image-quality messages from the reconstructions. Ten healthy volunteers and 1 patient were imaged at 0.55 T. Target SNR was selected based on retrospective analysis of cardiac output error, and performance of the automatic SNR-driven "stop" was assessed inline. Results: SNR calculation and automated segmentation was feasible within 20 s with inline deployment. The SNR-driven acquisition time was 2 min 39 s +/- 67 s (aorta) and 3 min +/- 80 s (main pulmonary artery) with a min/max acquisition time of 1 min 43 s/4 min 52 s (aorta) and 1 min 43 s/5 min 50 s (main pulmonary artery) across 6 healthy volunteers, while ensuring a diagnostic measurement with relative absolute error in quantitative flow measurement lower than 2.1% (aorta) and 6.3% (main pulmonary artery). Conclusion: The inline quality control enables subject-specific optimized scan times while ensuring consistent diagnostic image quality. The distribution of automated stopping times across the population revealed the value of a subject-specific scan time.
- Open Access
- 8 June 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1396-1413
Dynamic lung water MRI during exercise stress
Purpose: Exercise‐induced dyspnea caused by lung water is an early heart failure symptom. Dynamic lung water quantification during exercise is therefore of interest to detect early stage disease. This study developed a time‐resolved 3D MRI method to quantify transient lung water dynamics during rest and exercise stress.Methods: The method was evaluated in 15 healthy subjects and 2 patients with heart failure imaged in transitions between rest and exercise, and in a porcine model of dynamic extravascular lung water accumulation through mitral regurgitation (n = 5). Time‐resolved images were acquired at 0.55T using a continuous 3D stack‐of‐spirals proton density weighted sequence with 3.5 mm isotropic resolution, and derived using a motion corrected sliding‐window reconstruction with 90‐s temporal resolution in 20‐s increments. A supine MRI‐compatible pedal ergometer was used for exercise. Global and regional lung water density (LWD) and percent change in LWD (ΔLWD) were automatically quantified.Results: A ΔLWD increase of 3.3 ± 1.5% was achieved in the animals. Healthy subjects developed a ΔLWD of 7.8 ± 5.0% during moderate exercise, peaked at 16 ± 6.8% during vigorous exercise, and remained unchanged over 10 min at rest (−1.4 ± 3.5%, p = 0.18). Regional LWD were higher posteriorly compared the anterior lungs (rest: 33 ± 3.7% vs 20 ± 3.1%, p < 0.0001; peak exercise: 36 ± 5.5% vs 25 ± 4.6%, p < 0.0001). Accumulation rates were slower in patients than healthy subjects (2.0 ± 0.1%/min vs 2.6 ± 0.9%/min, respectively), whereas LWD were similar at rest (28 ± 10% and 28 ± 2.9%) and peak exercise (ΔLWD 17 ± 10% vs 16 ± 6.8%).Conclusion: Lung water dynamics can be quantified during exercise using continuous 3D MRI and a sliding‐window image reconstruction.
- 8 June 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1396-1413
Open AccessDynamic lung water MRI during exercise stress
Purpose: Exercise‐induced dyspnea caused by lung water is an early heart failure symptom. Dynamic lung water quantification during exercise is therefore of interest to detect early stage disease. This study developed a time‐resolved 3D MRI method to quantify transient lung water dynamics during rest and exercise stress.Methods: The method was evaluated in 15 healthy subjects and 2 patients with heart failure imaged in transitions between rest and exercise, and in a porcine model of dynamic extravascular lung water accumulation through mitral regurgitation (n = 5). Time‐resolved images were acquired at 0.55T using a continuous 3D stack‐of‐spirals proton density weighted sequence with 3.5 mm isotropic resolution, and derived using a motion corrected sliding‐window reconstruction with 90‐s temporal resolution in 20‐s increments. A supine MRI‐compatible pedal ergometer was used for exercise. Global and regional lung water density (LWD) and percent change in LWD (ΔLWD) were automatically quantified.Results: A ΔLWD increase of 3.3 ± 1.5% was achieved in the animals. Healthy subjects developed a ΔLWD of 7.8 ± 5.0% during moderate exercise, peaked at 16 ± 6.8% during vigorous exercise, and remained unchanged over 10 min at rest (−1.4 ± 3.5%, p = 0.18). Regional LWD were higher posteriorly compared the anterior lungs (rest: 33 ± 3.7% vs 20 ± 3.1%, p < 0.0001; peak exercise: 36 ± 5.5% vs 25 ± 4.6%, p < 0.0001). Accumulation rates were slower in patients than healthy subjects (2.0 ± 0.1%/min vs 2.6 ± 0.9%/min, respectively), whereas LWD were similar at rest (28 ± 10% and 28 ± 2.9%) and peak exercise (ΔLWD 17 ± 10% vs 16 ± 6.8%).Conclusion: Lung water dynamics can be quantified during exercise using continuous 3D MRI and a sliding‐window image reconstruction.
- Open Access
- 4 August 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (5) , 2326-2327
Erratum to: Self‐gated 3D stack‐of‐spirals UTE pulmonary imaging at 0.55 T (Magn Reson Med 2022;87:1784–1798)
- 4 August 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (5) , 2326-2327
Open AccessErratum to: Self‐gated 3D stack‐of‐spirals UTE pulmonary imaging at 0.55 T (Magn Reson Med 2022;87:1784–1798)
- 17 November 2021
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (3) , e4643
Myocardial blood flow is the dominant factor influencing cardiac magnetic resonance adenosine stress T2
Stress imaging identifies ischemic myocardium by comparing hemodynamics during rest and hyperemic stress. Hyperemia affects multiple hemodynamic parameters in myocardium, including myocardial blood flow (MBF), myocardial blood volume (MBV), and venous blood oxygen levels (PvO2). Cardiac T2 is sensitive to these changes and therefore is a promising non‐contrast option for stress imaging; however, the impact of individual hemodynamic factors on T2 is poorly understood, making the connection from altered T2 to changes within the tissue difficult. To better understand this interplay, we performed T2 mapping and measured various hemodynamic factors independently in healthy pigs at multiple levels of hyperemic stress, induced by different doses of adenosine (0.14‐0.56 mg/kg/min). T1 mapping quantified changes in MBV. MBF was assessed with microspheres, and oxygen consumption was determined by the rate pressure product (RPP). Simulations were also run to better characterize individual contributions to T2.Myocardial T2, MBF, oxygen consumption, and MBV all changed to varying extents between each level of adenosine stress (T2 = 37.6‐41.8 ms; MBF = 0.48‐1.32 mL/min/g; RPP = 6507‐4001 bmp*mmHg; maximum percent change in MBV = 1.31%). Multivariable analyses revealed MBF as the dominant influence on T2 during hyperemia (significant β‐values >7). Myocardial oxygen consumption had almost no effect on T2 (β‐values 2 is influenced by both oxygen consumption and MBF, PvO2 changes detected by T2 during adenosine stress can be attributed to MBF. Simulations varying PvO2 and MBV confirmed that PvO2 had the strongest influence on T2, but MBV became important at high PvO2. Together, these data suggest a model where, during adenosine stress, myocardial T2 responds predominantly to changes in MBF, but at high hyperemia MBV is also influential. Thus, changes in adenosine stress T2 can now be interpreted in terms of the physiological changes that led to it, enabling T2 mapping to become a viable non‐contrast option to detect ischemic myocardial tissue.
- 17 November 2021
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (3) , e4643
Myocardial blood flow is the dominant factor influencing cardiac magnetic resonance adenosine stress T2
Stress imaging identifies ischemic myocardium by comparing hemodynamics during rest and hyperemic stress. Hyperemia affects multiple hemodynamic parameters in myocardium, including myocardial blood flow (MBF), myocardial blood volume (MBV), and venous blood oxygen levels (PvO2). Cardiac T2 is sensitive to these changes and therefore is a promising non‐contrast option for stress imaging; however, the impact of individual hemodynamic factors on T2 is poorly understood, making the connection from altered T2 to changes within the tissue difficult. To better understand this interplay, we performed T2 mapping and measured various hemodynamic factors independently in healthy pigs at multiple levels of hyperemic stress, induced by different doses of adenosine (0.14‐0.56 mg/kg/min). T1 mapping quantified changes in MBV. MBF was assessed with microspheres, and oxygen consumption was determined by the rate pressure product (RPP). Simulations were also run to better characterize individual contributions to T2.Myocardial T2, MBF, oxygen consumption, and MBV all changed to varying extents between each level of adenosine stress (T2 = 37.6‐41.8 ms; MBF = 0.48‐1.32 mL/min/g; RPP = 6507‐4001 bmp*mmHg; maximum percent change in MBV = 1.31%). Multivariable analyses revealed MBF as the dominant influence on T2 during hyperemia (significant β‐values >7). Myocardial oxygen consumption had almost no effect on T2 (β‐values 2 is influenced by both oxygen consumption and MBF, PvO2 changes detected by T2 during adenosine stress can be attributed to MBF. Simulations varying PvO2 and MBV confirmed that PvO2 had the strongest influence on T2, but MBV became important at high PvO2. Together, these data suggest a model where, during adenosine stress, myocardial T2 responds predominantly to changes in MBF, but at high hyperemia MBV is also influential. Thus, changes in adenosine stress T2 can now be interpreted in terms of the physiological changes that led to it, enabling T2 mapping to become a viable non‐contrast option to detect ischemic myocardial tissue.
- 16 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (4) , 1784-1798
Self‐gated 3D stack‐of‐spirals UTE pulmonary imaging at 0.55T
Purpose: To develop an isotropic high‐resolution stack‐of‐spirals UTE sequence for pulmonary imaging at 0.55 Tesla by leveraging a combination of robust respiratory‐binning, trajectory correction, and concomitant‐field corrections.Methods: A stack‐of‐spirals golden‐angle UTE sequence was used to continuously acquire data for 15.5 minutes. The data was binned to a stable respiratory phase based on superoinferior readout self‐navigator signals. Corrections for trajectory errors and concomitant field artifacts, along with image reconstruction with conjugate gradient SENSE, were performed inline within the Gadgetron framework. Finally, data were retrospectively reconstructed to simulate scan times of 5, 8.5, and 12 minutes. Image quality was assessed using signal‐to‐noise, image sharpness, and qualitative reader scores. The technique was evaluated in healthy volunteers, patients with coronavirus disease 2019 infection, and patients with lung nodules.Results: The technique provided diagnostic quality images with parenchymal lung SNR of 3.18 ± 0.0.60, 4.57 ± 0.87, 5.45 ± 1.02, and 5.89 ± 1.28 for scan times of 5, 8.5, 12, and 15.5 minutes, respectively. The respiratory binning technique resulted in significantly sharper images (p < 0.001) as measured with relative maximum derivative at the diaphragm. Concomitant field corrections visibly improved sharpness of anatomical structures away from iso‐center. The image quality was maintained with a slight loss in SNR for simulated scan times down to 8.5 minutes. Inline image reconstruction and artifact correction were achieved in <5 minutes.Conclusion: The proposed pulmonary imaging technique combined efficient stack‐of‐spirals imaging with robust respiratory binning, concomitant field correction, and trajectory correction to generate diagnostic quality images with 1.75 mm isotropic resolution in 8.5 minutes on a high‐performance 0.55 Tesla system.
- 16 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (4) , 1784-1798
Self‐gated 3D stack‐of‐spirals UTE pulmonary imaging at 0.55T
Purpose: To develop an isotropic high‐resolution stack‐of‐spirals UTE sequence for pulmonary imaging at 0.55 Tesla by leveraging a combination of robust respiratory‐binning, trajectory correction, and concomitant‐field corrections.Methods: A stack‐of‐spirals golden‐angle UTE sequence was used to continuously acquire data for 15.5 minutes. The data was binned to a stable respiratory phase based on superoinferior readout self‐navigator signals. Corrections for trajectory errors and concomitant field artifacts, along with image reconstruction with conjugate gradient SENSE, were performed inline within the Gadgetron framework. Finally, data were retrospectively reconstructed to simulate scan times of 5, 8.5, and 12 minutes. Image quality was assessed using signal‐to‐noise, image sharpness, and qualitative reader scores. The technique was evaluated in healthy volunteers, patients with coronavirus disease 2019 infection, and patients with lung nodules.Results: The technique provided diagnostic quality images with parenchymal lung SNR of 3.18 ± 0.0.60, 4.57 ± 0.87, 5.45 ± 1.02, and 5.89 ± 1.28 for scan times of 5, 8.5, 12, and 15.5 minutes, respectively. The respiratory binning technique resulted in significantly sharper images (p < 0.001) as measured with relative maximum derivative at the diaphragm. Concomitant field corrections visibly improved sharpness of anatomical structures away from iso‐center. The image quality was maintained with a slight loss in SNR for simulated scan times down to 8.5 minutes. Inline image reconstruction and artifact correction were achieved in <5 minutes.Conclusion: The proposed pulmonary imaging technique combined efficient stack‐of‐spirals imaging with robust respiratory binning, concomitant field correction, and trajectory correction to generate diagnostic quality images with 1.75 mm isotropic resolution in 8.5 minutes on a high‐performance 0.55 Tesla system.