GGGüliz Görgül

Güliz Görgül

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Güliz Görgül has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Farklı Deney Düzeneği Kullanılarak Kök Kanalına Nd: YAG Lazer Uygulaması Sırasında Kök Yüzeyinde Oluşabilecek Sıcaklık Değişikliklerinin Değerlendirilmesi

    by Murat Maden, Güliz Görgül, Özgür Er, Özgür Uzun, Cevat Emre Erik

    Amaç: Bu çalışmada, kök kanalında Nd:YAG lazer uygulaması sırasında kök yüzeyinde oluşabilecek sıcaklık değerlerlerini saptamak ve kullanılan metodun güvenilirliğini araştırmak amaçlanmıştır. Gereç ve Yöntem: Çalışmada, çekilmiş 30 adet çürüksüz maksiller kanin ve santral diş kullanıldı. Giriş kaviteleri hazırlanan dişlerin kök kanal boyutları belirlendi. Dişler step-back tekniği ile 45 no’lu eğe boyutuna kadar genişletildi. Tüm dişler rastgele seçilerek her biri 10 adet dişten oluşan üç gruba ayrıldı. 1. gruptaki dişlere 1.5 W, 15 pps, 100 mj, 2. gruptaki dişlere 1.8 W, 15 pps, 120 mj ve 3. gruptaki dişlere de 2 W, 15 pps, 140 mj’de Nd:YAG lazer uygulaması öngörüldü. Bulgular ve Sonuç: İlk lazer uygulaması ve son lazer uygulaması sonucu oluşan sıcaklık değerleri ve gruplar arası karşılaştırma Student-T test ve One Way Anova analizi yardımıyla istatistiksel olarak değerlendirildi. Bu çalışmada test edilen tüm lazer seviyeleri göz önüne alındığında aralıklı lazer uygulamasının kabul edilebilir sınırlar içinde kaldığı ve hiçbir şekilde periapikal dokularda geriye dönüşümsüz hasar yaratan 10°C sınırını aşmadığı saptanmıştır.

  • Open Access

    Apical extrusion of sodium hypochlorite activated with two laser systems and ultrasonics: a spectrophotometric analysis

    by Bağdagül Helvacıoğlu Kıvanç, Hacer Deniz Arısu, Nazlı Özge Yanar, Hülya Mercan Silah, Recai İnam, Güliz Görgül

    The aim of the present study was to compare the effect of ultrasonically or laser (Nd:YAG or diode) activated irrigation on the irrigating solution extrusion compared to non-activated syringe irrigation. Extracted mandibular premolar teeth (n = 48) with single canals were instrumented. The teeth were secured through the lid of an Eppendorf tube filled with 1.0 mL distilled water to collect the apically extruded irrigating solution. The teeth were randomly divided into four groups: non-activated syringe irrigation, diode laser, Nd:YAG laser and passive ultrasonic irrigation (PUI) using 2 % NaOCl. The irrigating solution extruded through the apical foramen was collected in the Eppendorf tube and evaluated by a chemical reaction with using a spectrophotometer. The data was analyzed using one-way ANOVA and Tukey’s post hoc test (α = 0.05). All the groups showed apically extruded irrigating solution. There were significant differences among the groups (p < 0.05). Nd:YAG laser activated irrigation showed greater extrusion (p < 0.05), while the non-activated syringe irrigation showed less extrusion (p < 0.05). Only the difference between diode laser and PUI was not statistically significant (p > 0.05). Within the limitations of this in vitro study, the researchers concluded that non-activated syringe irrigation caused less apically extruded irrigating solution than PUI and LAI using Nd:YAG or diode lasers.


  • Effects of Nd: YAG Laser Irradiation on the Adaptation of Composite Resins to Root Dentin

    by Murat Maden, Güliz Görgül, A. Cemal Tinaz, Bağdagül H. Kivanç, Özgür Like Atasoy Ulusoy

    One of the most important goals of the restoration of endodontically treated teeth with a composite resin post system is to achieve good adaptation of the composite material to dentin walls to prevent microleakage apically and coronally. In post core systems, to avoid microleakage between the dentin wall and resin material, laser irradiation may seem to be an alternative therapy for increasing adaptation quality. The aim of this study was to investigate the adaptation of a packable composite resin to lased root canal dentin when it was used as post material. Forty-five freshly extracted human teeth were selected and post spaces were prepared. The teeth were divided into three groups. In group 1 the dentin of the post spaces were etched with 35% phosphoric acid, in group 2 the dentin surfaces were irradiated with an Nd: YAG laser, and in group 3 the dentin surfaces were initially treated with the laser and then etched. The teeth of all groups were obturated with a bonding agent and composite. The groups were divided into two subgroups: a group for the scanning electron microscope (SEM) study and a group for the microleakage study. The lased group showed poor adaptation and more microleakage was detected (p0.05). The Nd: YAG laser irradiation adversely affects adhesion to dentin for using composite resin as a post material and does not constitute an alternative to acid-etching. Citation: Görgül G, Kivanç BH, Maden M, Ulsoy ÖLA, Tinaz AC. Effects of Nd: YAG Laser Irradiation on the Adaptation of Composite Resins to Root Dentin. J Contemp Dent Pract 2005 November;(6)4:116-123.


  • Microleakage of Packable Composites Used in Post Spaces Condensed Using Different Methods

    by Güliz Görgül, A. Cemal Tinaz, Tayfun Alaçam, Bağdagül H. Kivanç, Özgür Uzun

    The aim of this in vitro study was to evaluate the apical and coronal microleakage of a packable composite material compacted by either hand or ultrasonic condensers when placed in post spaces. Fortytwo extracted anterior teeth were used. After conventional obturation of the root canals, parallel post spaces 5 mm in depth and 2 mm in diameter were prepared using Gates Glidden and diamond burs. A primer and a dentin bonding agent (Prime & Bond NT) was applied to the etched surface for 30 seconds and light polymerized for 40 seconds. Surefil packable composite resin was inserted in four equal increments and each polymerized for 40 seconds. Half of the specimens were compacted with an ultrasonic tip and the other half with a mechanical hand compactor. After immersion in the dye, the teeth were sectioned longitudinally and dye penetration was evaluated using a stereomicroscope and microleakage recorded in mm. A One-Way Analysis of Variance indicated the two condensing methods were not statistically different (p>0.05). When microleakage was compared within groups, there was also no statistical difference between coronal or apical microleakage (p>0.05). In an in vitro environment, ultrasonic condensers do not offer any advantage over hand condensers. Both the coronal and apical portions of the root had microleakage indicating that regardless of the condensation method and the use of a packable composite, there is still microleakage that could potentially create further clinical problems. Citation: Görgül G, Alaçam T, Kivanç BH, et. al. Microleakage of Packable Composites Used in Post Spaces Condensed Using Different Methods. J Contemp Dent Pract 2002 May;(3)2: 023-030.


  • Evaluation of Apical Leakage of Root Canals Obturated with Nd: YAG Laser Softened Gutta-Percha, System-B, and Lateral Condensation Techniques

    by Murat Maden, Güliz Görgül, A. Cemal Tinaz

    In endodontics, a laser can be used as a heat source and gutta-percha can be softened by a laser and used in the root canals. The System-B endodontic heat source unit was designed for the obturation of the root canal system with a single continuous wave of thermoplasticized gutta-percha. The aim of this study was to compare the apical leakage of lateral condensation; Nd:YAG laser-softened gutta-percha and System-B techniques. Fifty-five extracted, single root human maxillary anterior and premolar teeth were used in this study. After working length determination, the “step-back technique” was used to prepare the root canals. The teeth were randomly divided into three experimental groups of 15 each and two control groups of 5 specimens each. The first group was obturated by lateral condensation, the second group by gutta-percha softened with an Nd:YAG laser, and the third group was obturated using the system-B technique. Apical leakage of the roots was evaluated by dye penetration using a stereomicroscope after sectioning the roots. The results of the first and third groups were similar, and the results of the second group showed differences when compared with the other groups. However, variance analysis revealed there was no statistically significant difference among the results. Citation: Maden M, Görgül G, Tinaz AC. Evaluation of Apical Leakage of Root Canals Obturated with Nd:Yag laser-softened Gutta-percha, System-B, and Lateral Condensation Techniques. J Contemp Dent Pract 2002 Feb;(3)1: 016-026.