Tetsuya Tatsumi
Research Subjects
Tetsuya Tatsumi has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hiroshi Kubota
Department of Cardiovascular Medicine, Kyoto Chubu Medical Center, 25, Yagi-Ueno, Yagi-cho, Nantan, Japan
4 shared publications - Natsuya Keira
Department of Cardiovascular Medicine, Nantan General Hospital, Japan
4 shared publications - Tetsuya Nomura
Department of Cardiovascular Medicine, Kyoto Chubu Medical Center, 25, Yagi-Ueno, Yagi-cho, Nantan City, Kyoto 629-0197, Japan
4 shared publications - Ryota Urata
Department of Cardiovascular Medicine, Kyoto Chubu Medical Center, 25, Yagi-Ueno, Yagi-cho, Nantan, Japan.
3 shared publications - Takeshi Sugimoto
Department of Cardiovascular Medicine, Kyoto Chubu Medical Center, 25, Yagi-Ueno, Yagi-cho, Nantan, Japan
3 shared publications - Taku Kato
Nantan General Hospital
3 shared publications
Latest Publications
- Open Access
- 21 March 2019
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 13 (1) , 90
Successful bailout procedure for acute popliteal artery occlusion associated with EXOSEAL® vascular closure device: a case report
Vascular closure devices have been widely used to achieve rapid hemostasis after percutaneous catheterization procedures via the common femoral artery. The EXOSEAL vascular closure device is a device that can deliver a bioabsorbable polyglycolic acid plug to fill the subcutaneous puncture route at the groin for rapid hemostasis, and this device has a lower risk of arterial occlusion than other vascular closure devices. An 83-year-old Japanese man underwent percutaneous coronary intervention for a proximal stenosis in his left circumflex artery through a 7-Fr sheath from his right common femoral artery. We encountered acute popliteal artery occlusion associated with EXOSEAL vascular closure device. We detected the plug material of this device at the occluded lesion by intravascular ultrasound, and performed successful bailout stenting after pulling the embolus with an inflated balloon catheter up to the superficial femoral artery from the popliteal artery. Acute limb ischemia caused by an EXOSEAL vascular closure device is a very rare complication. Balloon angioplasty and stenting are considered to be effective options to deal with the plug dislodgement of an EXOSEAL vascular closure device. We must be prepared for every rare complication during endovascular treatment.
- 21 March 2019
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 13 (1) , 90
Open AccessSuccessful bailout procedure for acute popliteal artery occlusion associated with EXOSEAL® vascular closure device: a case report
Vascular closure devices have been widely used to achieve rapid hemostasis after percutaneous catheterization procedures via the common femoral artery. The EXOSEAL vascular closure device is a device that can deliver a bioabsorbable polyglycolic acid plug to fill the subcutaneous puncture route at the groin for rapid hemostasis, and this device has a lower risk of arterial occlusion than other vascular closure devices. An 83-year-old Japanese man underwent percutaneous coronary intervention for a proximal stenosis in his left circumflex artery through a 7-Fr sheath from his right common femoral artery. We encountered acute popliteal artery occlusion associated with EXOSEAL vascular closure device. We detected the plug material of this device at the occluded lesion by intravascular ultrasound, and performed successful bailout stenting after pulling the embolus with an inflated balloon catheter up to the superficial femoral artery from the popliteal artery. Acute limb ischemia caused by an EXOSEAL vascular closure device is a very rare complication. Balloon angioplasty and stenting are considered to be effective options to deal with the plug dislodgement of an EXOSEAL vascular closure device. We must be prepared for every rare complication during endovascular treatment.
- Open Access
- 2 August 2016
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 16 (1) , 1-6
Instructive percutaneous coronary intervention to avoid the risk of side branch occlusion at a lesion with a lotus root appearance: a case report
A lotus root appearance is a rare entity, and there is little opportunity to perform coronary intervention for this kind of lesion. Because of its peculiar anatomical characteristics, one of the problems regarding percutaneous coronary intervention (PCI) for these lesions is related to the involvement of branch vessels. We encountered a case of PCI for a stenotic lesion with a lotus root appearance in the mid-portion of the right coronary artery (RCA). To avoid the risk of right ventricular (RV) branch occlusion due to stent deployment in the main RCA, we re-crossed the third guidewire into the main RCA via the nearest point to the RV branch ostium through the communicating vascular lumen. Thereafter, we deployed a drug-eluting stent in the main RCA crossing over the RV branch, and the ostium of the RV branch remained intact, as we expected. This case is the first report in the world describing the details of how to maintain the patency of the side branch bifurcating from a lesion with a lotus root appearance under optical coherence tomography guidance.
- 2 August 2016
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 16 (1) , 1-6
Open AccessInstructive percutaneous coronary intervention to avoid the risk of side branch occlusion at a lesion with a lotus root appearance: a case report
A lotus root appearance is a rare entity, and there is little opportunity to perform coronary intervention for this kind of lesion. Because of its peculiar anatomical characteristics, one of the problems regarding percutaneous coronary intervention (PCI) for these lesions is related to the involvement of branch vessels. We encountered a case of PCI for a stenotic lesion with a lotus root appearance in the mid-portion of the right coronary artery (RCA). To avoid the risk of right ventricular (RV) branch occlusion due to stent deployment in the main RCA, we re-crossed the third guidewire into the main RCA via the nearest point to the RV branch ostium through the communicating vascular lumen. Thereafter, we deployed a drug-eluting stent in the main RCA crossing over the RV branch, and the ostium of the RV branch remained intact, as we expected. This case is the first report in the world describing the details of how to maintain the patency of the side branch bifurcating from a lesion with a lotus root appearance under optical coherence tomography guidance.
- Open Access
- 28 July 2015
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 9 (1) , 1-6
Successful percutaneous coronary intervention with GuideLiner® catheter for subtotal occlusive lesion in the right coronary artery with anomalous origin from the left sinus of Valsalva: a case report
- 28 July 2015
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 9 (1) , 1-6
Open AccessSuccessful percutaneous coronary intervention with GuideLiner® catheter for subtotal occlusive lesion in the right coronary artery with anomalous origin from the left sinus of Valsalva: a case report
- Open Access
- 9 April 2014
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 8 (1) , 124
Apical myocardial infarction with bizarre coronary images mimicking left ventricular apical ballooning syndrome: a case report
Although several etiopathogenetic mechanisms have been proposed, the causes of left ventricular apical ballooning syndrome are still controversial.
- 9 April 2014
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 8 (1) , 124
Open AccessApical myocardial infarction with bizarre coronary images mimicking left ventricular apical ballooning syndrome: a case report
Although several etiopathogenetic mechanisms have been proposed, the causes of left ventricular apical ballooning syndrome are still controversial.