Successful bailout procedure for acute popliteal artery occlusion associated with EXOSEAL® vascular closure device: a case report
Authors:
- Ryota UrataRURyota Urata
- Tetsuya NomuraTNTetsuya Nomura
- Yusuke HoriYHYusuke Hori
- Kenichi YoshiokaKYKenichi Yoshioka
- Hiroshi KubotaHKHiroshi Kubota
- Daisuke MiyawakiDMDaisuke Miyawaki
- Takeshi SugimotoTSTakeshi Sugimoto
- Masakazu KikaiMKMasakazu Kikai
- Natsuya KeiraNKNatsuya Keira
- Tetsuya TatsumiTTTetsuya Tatsumi
Open Access
- 21 March 2019
- journal article
- case report
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 13 (1) , 90
Abstract
Vascular closure devices have been widely used to achieve rapid hemostasis after percutaneous catheterization procedures via the common femoral artery. The EXOSEAL vascular closure device is a device that can deliver a bioabsorbable polyglycolic acid plug to fill the subcutaneous puncture route at the groin for rapid hemostasis, and this device has a lower risk of arterial occlusion than other vascular closure devices. An 83-year-old Japanese man underwent percutaneous coronary intervention for a proximal stenosis in his left circumflex artery through a 7-Fr sheath from his right common femoral artery. We encountered acute popliteal artery occlusion associated with EXOSEAL vascular closure device. We detected the plug material of this device at the occluded lesion by intravascular ultrasound, and performed successful bailout stenting after pulling the embolus with an inflated balloon catheter up to the superficial femoral artery from the popliteal artery. Acute limb ischemia caused by an EXOSEAL vascular closure device is a very rare complication. Balloon angioplasty and stenting are considered to be effective options to deal with the plug dislodgement of an EXOSEAL vascular closure device. We must be prepared for every rare complication during endovascular treatment.Keywords
This publication has 6 references indexed in Scilit:
- Vascular Closure Devices: Technical Tips, Complications, and ManagementTechniques in Vascular and Interventional Radiology, 2015
- Cases of Femoral Artery Occlusion after using the Exoseal Closure Device: Including Experiment in Vascular ModelCardiovascular Intervention and Therapeutics Japanese Edition, 2015
- Percutaneous Vascular Closure System Based on an Extravascular, Bioabsorbable Polyglycolic Plug (ExoSeal): Results from 1000 PatientsClinical Medicine Insights: Cardiology, 2014
- Endovascular treatment of acute limb ischemia caused by an intravascularly deployed bioabsorbable plug of a vascular closure deviceVasa, 2013
- Meta-analysis of randomized trials on the efficacy of vascular closure devices after diagnostic angiography and angioplastyAmerican Heart Journal, 2010
- A Randomized Comparison of a Novel Bioabsorbable Vascular Closure Device Versus Manual Compression in the Achievement of Hemostasis After Percutaneous Femoral ProceduresJACC: Cardiovascular Interventions, 2009