Edmond J. Walsh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Edmond J. Walsh has a total of 132 co-authors. Here are the top co-authors by number of shared publications:
- Ronan Grimes
Stokes Institute, University of Limerick, Limerick, Ireland
34 shared publications - Pat Walsh
University of Limerick
31 shared publications - Vanessa Egan
CONNECT, Stokes Laboratories, Bernal Institute, University of Limerick, Ireland, V94T9PX
16 shared publications - Jeff Punch
University of Limerick
15 shared publications - Peter Richard Cook
University of Oxford
13 shared publications Donald M. McEligot
11 shared publications
Latest Publications
- Open Access
Identification and isolation of migratory subpopulations of cancer cells using microfluidics with fluid walls
Microfluidic assays have great potential for investigating cancer cell migration, a key process underlying metastasis which remains a major clinical challenge. However, adoption by biologists is limited due to complex fabrication and operation methods combined with difficulty in retrieving cells of interest. We jet-print dumbbell-shaped microfluidic environments with fluid walls in standard Petri dishes in seconds using standard growth media and immiscible oil. Prostate cancer cells and chemoattractant (bovine serum) are introduced into each end using local transient differences in Laplace pressure to enable spatial confinement. Automated live-cell imaging monitors chemotaxis towards serum using standard microscopes, as the confining fluid walls are optically transparent. Distinct subpopulations of migratory cells exhibit different morphologies and motilities, assessed using a custom machine-learning segmentation model. Then, we leverage the reconfigurability of fluid walls to isolate and retrieve rapidly-migrating single cells. This demonstrates that fluid-walled microfluidics is a versatile and accessible approach for investigating cancer cell migration at single-cell resolution, offering new opportunities to examine cellular heterogeneity in metastasis.
Open AccessIdentification and isolation of migratory subpopulations of cancer cells using microfluidics with fluid walls
Microfluidic assays have great potential for investigating cancer cell migration, a key process underlying metastasis which remains a major clinical challenge. However, adoption by biologists is limited due to complex fabrication and operation methods combined with difficulty in retrieving cells of interest. We jet-print dumbbell-shaped microfluidic environments with fluid walls in standard Petri dishes in seconds using standard growth media and immiscible oil. Prostate cancer cells and chemoattractant (bovine serum) are introduced into each end using local transient differences in Laplace pressure to enable spatial confinement. Automated live-cell imaging monitors chemotaxis towards serum using standard microscopes, as the confining fluid walls are optically transparent. Distinct subpopulations of migratory cells exhibit different morphologies and motilities, assessed using a custom machine-learning segmentation model. Then, we leverage the reconfigurability of fluid walls to isolate and retrieve rapidly-migrating single cells. This demonstrates that fluid-walled microfluidics is a versatile and accessible approach for investigating cancer cell migration at single-cell resolution, offering new opportunities to examine cellular heterogeneity in metastasis.
- Open Access
- 19 July 2025
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 122 (10) , 2739-2750
Generation of Clonal Cultures of Adherent or Suspension Cells Using Flat Sessile Drops for Assurance of Monoclonality
Single‐cell isolation is an essential step in many biomedical workflows, including genetic analyses and drug‐based assays. It is commonly attempted through limiting dilution into microtiter wells. However, dark optical edge effects at the well periphery make it difficult to confirm which wells contain just one cell. Consequently, statistical methods are used to obtain the probability that a well contains a single cell. Sessile microdrops can be deposited in the center of wells away from obscuring walls. If these drops have low contact angles, optical edge effects are minimal. A dilute cell suspension can be infused into such drops, which are then imaged to confirm the presence of a single cell with certainty. Subsequently, wells are flooded with media and incubated to allow clonal growth. The fraction of single cells yielding colonies then provides an accurate and non‐probabilistic measure of cloning efficiency. We demonstrate average cloning efficiencies between 62% and 78% with human embryonic kidney, cancer, and induced pluripotent stem cells, as well as Chinese‐hamster suspension cells. We verify that stem cells continue to express pluripotency markers after cloning and incorporate the method into a gene‐editing workflow for cell‐line development. This demonstrates the seamless integration of sessile microdrops into established protocols, providing assurance of monoclonality with high cloning efficiency.
- 19 July 2025
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 122 (10) , 2739-2750
Open AccessGeneration of Clonal Cultures of Adherent or Suspension Cells Using Flat Sessile Drops for Assurance of Monoclonality
Single‐cell isolation is an essential step in many biomedical workflows, including genetic analyses and drug‐based assays. It is commonly attempted through limiting dilution into microtiter wells. However, dark optical edge effects at the well periphery make it difficult to confirm which wells contain just one cell. Consequently, statistical methods are used to obtain the probability that a well contains a single cell. Sessile microdrops can be deposited in the center of wells away from obscuring walls. If these drops have low contact angles, optical edge effects are minimal. A dilute cell suspension can be infused into such drops, which are then imaged to confirm the presence of a single cell with certainty. Subsequently, wells are flooded with media and incubated to allow clonal growth. The fraction of single cells yielding colonies then provides an accurate and non‐probabilistic measure of cloning efficiency. We demonstrate average cloning efficiencies between 62% and 78% with human embryonic kidney, cancer, and induced pluripotent stem cells, as well as Chinese‐hamster suspension cells. We verify that stem cells continue to express pluripotency markers after cloning and incorporate the method into a gene‐editing workflow for cell‐line development. This demonstrates the seamless integration of sessile microdrops into established protocols, providing assurance of monoclonality with high cloning efficiency.
- Open Access
- 30 July 2024
- Published by Elsevier in International Journal of Thermofluids
- Vol. 23
Performance of pin-fin structures on pool boiling heat transfer
- 30 July 2024
- Published by Elsevier in International Journal of Thermofluids
- Vol. 23
Open AccessPerformance of pin-fin structures on pool boiling heat transfer
- Open Access
- 20 June 2024
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 10 (1) , 1-11
Stable diffusion gradients in microfluidic conduits bounded by fluid walls
Assays mimicking in vitro the concentration gradients triggering biological responses like those involved in fighting infections and blood clotting are essential for biomedical research. Microfluidic assays prove especially attractive as they allow precise control of gradient shape allied to a reduction in scale. Conventional microfluidic devices are fabricated using solid plastics that prevent direct access to responding cells. Fluid-walled microfluidics allows the manufacture of circuits on standard Petri dishes in seconds, coupled to simple operating methods; cell-culture medium sitting in a standard dish is confined to circuits by fluid walls made of an immiscible fluorocarbon. We develop and experimentally validate an analytical model of diffusion between two or more aqueous streams flowing at different rates into a fluid-walled conduit with the cross-section of a circular segment. Unlike solid walls, fluid walls morph during flows as pressures fall, with wall shape changing down the conduit. The model is validated experimentally for Fourier numbers < 0.1 using fluorescein diffusing between laminar streams. It enables a priori prediction of concentration gradients throughout a conduit, so allowing rapid circuit design as well as providing bio-scientists with an accurate way of predicting local concentrations of bioactive molecules around responsive and non-responsive cells.
- 20 June 2024
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 10 (1) , 1-11
Open AccessStable diffusion gradients in microfluidic conduits bounded by fluid walls
Assays mimicking in vitro the concentration gradients triggering biological responses like those involved in fighting infections and blood clotting are essential for biomedical research. Microfluidic assays prove especially attractive as they allow precise control of gradient shape allied to a reduction in scale. Conventional microfluidic devices are fabricated using solid plastics that prevent direct access to responding cells. Fluid-walled microfluidics allows the manufacture of circuits on standard Petri dishes in seconds, coupled to simple operating methods; cell-culture medium sitting in a standard dish is confined to circuits by fluid walls made of an immiscible fluorocarbon. We develop and experimentally validate an analytical model of diffusion between two or more aqueous streams flowing at different rates into a fluid-walled conduit with the cross-section of a circular segment. Unlike solid walls, fluid walls morph during flows as pressures fall, with wall shape changing down the conduit. The model is validated experimentally for Fourier numbers < 0.1 using fluorescein diffusing between laminar streams. It enables a priori prediction of concentration gradients throughout a conduit, so allowing rapid circuit design as well as providing bio-scientists with an accurate way of predicting local concentrations of bioactive molecules around responsive and non-responsive cells.
- Open Access
- 6 June 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (13) , 3252-3264
A fluid-walled microfluidic platform for human neuron microcircuits and directed axotomy
In vivo , different neurons make directional connections; however, most in vitro models fail to capture such connectivity. We use microfluidics with fluid walls to study neuronal circuits in vitro in ways that fit into existing bio-medical workflows.
- 6 June 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (13) , 3252-3264
Open AccessA fluid-walled microfluidic platform for human neuron microcircuits and directed axotomy
In vivo , different neurons make directional connections; however, most in vitro models fail to capture such connectivity. We use microfluidics with fluid walls to study neuronal circuits in vitro in ways that fit into existing bio-medical workflows.
- Open Access
- 3 March 2024
- Published by Elsevier in International Journal of Thermofluids
- Vol. 22
Pool boiling heat transfer of Novec 649 on sandblasted surfaces
- 3 March 2024
- Published by Elsevier in International Journal of Thermofluids
- Vol. 22
Open AccessPool boiling heat transfer of Novec 649 on sandblasted surfaces
- Open Access
A fluid-walled microfluidic platform for human neuron microcircuits and directed axotomy
In our brains, different neurons make appropriate connections; however, there remain few in vitro models of such circuits. We use an open microfluidic approach to build and study neuronal circuits in vitro in ways that fit easily into existing bio-medical workflows. Dumbbell-shaped circuits are built in minutes in standard Petri dishes; the aqueous phase is confined by fluid walls – interfaces between cell-growth medium and an immiscible fluorocarbon, FC40. Conditions are established that ensure post-mitotic neurons derived from human induced pluripotent stem cells (iPSCs) plated in one chamber of a dumbbell remain where deposited. After seeding cortical neurons on one side, axons grow through the connecting conduit to ramify amongst striatal neurons on the other – an arrangement mimicking unidirectional cortico-striatal connectivity. We also develop a moderate-throughput non-contact axotomy assay. Cortical axons in conduits are severed by a media jet; then, brain-derived neurotrophic factor and striatal neurons in distal chambers promote axon regeneration. As additional conduits and chambers are easily added, this opens up the possibility of mimicking complex neuronal networks, and screening drugs for their effects on connectivity.
Open AccessA fluid-walled microfluidic platform for human neuron microcircuits and directed axotomy
In our brains, different neurons make appropriate connections; however, there remain few in vitro models of such circuits. We use an open microfluidic approach to build and study neuronal circuits in vitro in ways that fit easily into existing bio-medical workflows. Dumbbell-shaped circuits are built in minutes in standard Petri dishes; the aqueous phase is confined by fluid walls – interfaces between cell-growth medium and an immiscible fluorocarbon, FC40. Conditions are established that ensure post-mitotic neurons derived from human induced pluripotent stem cells (iPSCs) plated in one chamber of a dumbbell remain where deposited. After seeding cortical neurons on one side, axons grow through the connecting conduit to ramify amongst striatal neurons on the other – an arrangement mimicking unidirectional cortico-striatal connectivity. We also develop a moderate-throughput non-contact axotomy assay. Cortical axons in conduits are severed by a media jet; then, brain-derived neurotrophic factor and striatal neurons in distal chambers promote axon regeneration. As additional conduits and chambers are easily added, this opens up the possibility of mimicking complex neuronal networks, and screening drugs for their effects on connectivity.
- Open Access
- 22 August 2023
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 969, A28
Flows in fluid-walled conduits driven by Laplace pressure
In conventional microfluidic devices, fluids are often confined behind solid plastic walls that restrict access and trap gas bubbles; in open microfluidics some solid walls are replaced by fluid ones (i.e. interfaces with immiscible fluids). In both cases, flows are usually driven by external pumps or gravity. An innovative open technology has been developed in which two-dimensional patterns of cell-culture medium in standard Petri dishes are confined by fluid walls made of an immiscible and bio-inert fluorocarbon (FC40). To provide refreshing media flows to cells in such circuits, an established pumping system that exploits differences in Laplace pressure across open interfaces has been applied to drive flow without using external pumps: a source drop autonomously empties through a straight conduit into the rest of the dish (the sink). Whereas conduits with solid walls have unchanging boundaries and flows within them are well understood, the challenge is to predict flows in circuits where fluid walls morph as pressures change. Numerical and semi-analytical equations enabling the prediction of changing flows are developed, and predictions validated experimentally.
- 22 August 2023
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 969, A28
Open AccessFlows in fluid-walled conduits driven by Laplace pressure
In conventional microfluidic devices, fluids are often confined behind solid plastic walls that restrict access and trap gas bubbles; in open microfluidics some solid walls are replaced by fluid ones (i.e. interfaces with immiscible fluids). In both cases, flows are usually driven by external pumps or gravity. An innovative open technology has been developed in which two-dimensional patterns of cell-culture medium in standard Petri dishes are confined by fluid walls made of an immiscible and bio-inert fluorocarbon (FC40). To provide refreshing media flows to cells in such circuits, an established pumping system that exploits differences in Laplace pressure across open interfaces has been applied to drive flow without using external pumps: a source drop autonomously empties through a straight conduit into the rest of the dish (the sink). Whereas conduits with solid walls have unchanging boundaries and flows within them are well understood, the challenge is to predict flows in circuits where fluid walls morph as pressures change. Numerical and semi-analytical equations enabling the prediction of changing flows are developed, and predictions validated experimentally.
- Open Access
- 19 July 2022
- Published by Wiley in Advanced Materials Technologies
- Vol. 7 (9)
Assaying Macrophage Chemotaxis Using Fluid‐Walled Microfluidics
While many tools exist to study immune‐cell chemotaxis in vitro, current methods often lack desirable features. Using fluid‐walled microfluidics, circuits are built around primary murine macrophages deposited in pre‐defined patterns on Petri dishes or microplates. Concentration gradients of complement component 5a (C5a) are established in flow‐free or flowing environments, cell migration imaged, and cell directionality and velocity correlated to calculated local C5a concentrations. In flow‐free circuits built around patterned macrophages, only cells nearest the C5a source migrate regardless of local attractant concentration. Conversely, in flowing circuits free from intercellular signaling and attractant degradation, only cells distant from the source migrate. In both systems, cells respond to lower C5a concentrations than previously reported (≈0.1 pM). Finally, macrophages follow instantly‐shifted gradients better than slowly‐shifting ones, suggesting that migration depends on both spatial and temporal responses to concentration.
- 19 July 2022
- Published by Wiley in Advanced Materials Technologies
- Vol. 7 (9)
Open AccessAssaying Macrophage Chemotaxis Using Fluid‐Walled Microfluidics
While many tools exist to study immune‐cell chemotaxis in vitro, current methods often lack desirable features. Using fluid‐walled microfluidics, circuits are built around primary murine macrophages deposited in pre‐defined patterns on Petri dishes or microplates. Concentration gradients of complement component 5a (C5a) are established in flow‐free or flowing environments, cell migration imaged, and cell directionality and velocity correlated to calculated local C5a concentrations. In flow‐free circuits built around patterned macrophages, only cells nearest the C5a source migrate regardless of local attractant concentration. Conversely, in flowing circuits free from intercellular signaling and attractant degradation, only cells distant from the source migrate. In both systems, cells respond to lower C5a concentrations than previously reported (≈0.1 pM). Finally, macrophages follow instantly‐shifted gradients better than slowly‐shifting ones, suggesting that migration depends on both spatial and temporal responses to concentration.
- Open Access
- 23 May 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (22) , 25209-25219
Reconfigurable Microfluidic Circuits for Isolating and Retrieving Cells of Interest
Microfluidic devices are widely used in many fields of biology, but a key limitation is that cells are typically surrounded by solid walls, making it hard to access those that exhibit a specific phenotype for further study. Here, we provide a general and flexible solution to this problem that exploits the remarkable properties of microfluidic circuits with fluid walls-transparent interfaces between culture media and an immiscible fluorocarbon that are easily pierced with pipets. We provide two proofs of concept in which specific cell subpopulations are isolated and recovered: (i) murine macrophages chemotaxing toward complement component 5a and (ii) bacteria (Pseudomonas aeruginosa) in developing biofilms that migrate toward antibiotics. We build circuits in minutes on standard Petri dishes, add cells, pump in laminar streams so molecular diffusion creates attractant gradients, acquire time-lapse images, and isolate desired subpopulations in real time by building fluid walls around migrating cells with an accuracy of tens of micrometers using 3D printed adaptors that convert conventional microscopes into wall-building machines. Our method allows live cells of interest to be easily extracted from microfluidic devices for downstream analyses.
- 23 May 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (22) , 25209-25219
Open AccessReconfigurable Microfluidic Circuits for Isolating and Retrieving Cells of Interest
Microfluidic devices are widely used in many fields of biology, but a key limitation is that cells are typically surrounded by solid walls, making it hard to access those that exhibit a specific phenotype for further study. Here, we provide a general and flexible solution to this problem that exploits the remarkable properties of microfluidic circuits with fluid walls-transparent interfaces between culture media and an immiscible fluorocarbon that are easily pierced with pipets. We provide two proofs of concept in which specific cell subpopulations are isolated and recovered: (i) murine macrophages chemotaxing toward complement component 5a and (ii) bacteria (Pseudomonas aeruginosa) in developing biofilms that migrate toward antibiotics. We build circuits in minutes on standard Petri dishes, add cells, pump in laminar streams so molecular diffusion creates attractant gradients, acquire time-lapse images, and isolate desired subpopulations in real time by building fluid walls around migrating cells with an accuracy of tens of micrometers using 3D printed adaptors that convert conventional microscopes into wall-building machines. Our method allows live cells of interest to be easily extracted from microfluidic devices for downstream analyses.