Ronan Grimes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Ronan Grimes has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Edmond J. Walsh
Department of Engineering Science, University of Oxford, OX1 3PJ, UK
34 shared publications - Pat Walsh
University of Limerick
17 shared publications - Jeff Punch
University of Limerick
13 shared publications Ed Walsh
University of Limerick, Limerick, Ireland
10 shared publications- Vanessa Egan
CONNECT, Stokes Laboratories, Bernal Institute, University of Limerick, Ireland, V94T9PX
9 shared publications - Asensio Gonzalez
Northern Ireland Regional Histocompatibility and Immunogenetics Laboratory, City Hospital, Belfast, UK
5 shared publications
Latest Publications
- Open Access
- 29 July 2026
- Published by Elsevier in SSRN Electronic Journal
Levelized Cost of Heat Based Optimisation Framework of Plate Heat Exchangers for High Temperature Heat Pumps: Simultaneous Optimisation of Geometry, Pinch Point Temperature Difference and CO₂/Acetone Mixtures Composition
High-temperature heat pumps (HTHPs) delivering heat at 200 °C and above require large temperature lifts, leading to increased thermodynamic irreversibilities and greater sensitivity to heat exchanger pressure losses and pinch point temperature differences ( ∆Tpp ). While plate heat exchangers (PHEs) and zeotropic refrigerants have been widely investigated for HTHPs, previous studies have largely relied on fixed heat exchanger geometries and prescribed ∆Tpp values, overlooking the coupled effects of PHE design, pressure drop induced compressor power, refrigerant composition, and system-level economics. The novelty of this study is the comprehensive thermo-economic optimisation framework that simultaneously optimises evaporator and condenser PHE geometries, ∆Tpp , and CO₂/acetone refrigerant composition to minimise the levelized cost of heat ( LCOHΔP both ). The framework explicitly accounts for the additional compressor power required to overcome pressure losses in both heat exchangers. Four PHE geometric parameters, plate length, plate width, corrugation pitch, and corrugation height were optimised by evaluating 34,944 geometric configurations across 16 ∆Tpp values. Unlike conventional approaches, ∆Tpp was treated as a design variable, enabling simultaneous optimisation of heat exchanger geometry and operating conditions. The optimum configuration, comprising an 8% CO₂/92% acetone mixture with a ∆Tpp of 1.6 K, achieved the lowest LCOHΔP both of 0.0667 €/kWh. The results indicate that the evaporator pressure drop contributes more significantly to performance degradation than the condenser pressure drop and highlight the importance of integrated optimisation of heat exchanger design, refrigerant composition, ∆Tpp , and pressure-drop effects to minimise heat generation costs in high-temperature industrial waste heat recovery syste
- 29 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessLevelized Cost of Heat Based Optimisation Framework of Plate Heat Exchangers for High Temperature Heat Pumps: Simultaneous Optimisation of Geometry, Pinch Point Temperature Difference and CO₂/Acetone Mixtures Composition
High-temperature heat pumps (HTHPs) delivering heat at 200 °C and above require large temperature lifts, leading to increased thermodynamic irreversibilities and greater sensitivity to heat exchanger pressure losses and pinch point temperature differences ( ∆Tpp ). While plate heat exchangers (PHEs) and zeotropic refrigerants have been widely investigated for HTHPs, previous studies have largely relied on fixed heat exchanger geometries and prescribed ∆Tpp values, overlooking the coupled effects of PHE design, pressure drop induced compressor power, refrigerant composition, and system-level economics. The novelty of this study is the comprehensive thermo-economic optimisation framework that simultaneously optimises evaporator and condenser PHE geometries, ∆Tpp , and CO₂/acetone refrigerant composition to minimise the levelized cost of heat ( LCOHΔP both ). The framework explicitly accounts for the additional compressor power required to overcome pressure losses in both heat exchangers. Four PHE geometric parameters, plate length, plate width, corrugation pitch, and corrugation height were optimised by evaluating 34,944 geometric configurations across 16 ∆Tpp values. Unlike conventional approaches, ∆Tpp was treated as a design variable, enabling simultaneous optimisation of heat exchanger geometry and operating conditions. The optimum configuration, comprising an 8% CO₂/92% acetone mixture with a ∆Tpp of 1.6 K, achieved the lowest LCOHΔP both of 0.0667 €/kWh. The results indicate that the evaporator pressure drop contributes more significantly to performance degradation than the condenser pressure drop and highlight the importance of integrated optimisation of heat exchanger design, refrigerant composition, ∆Tpp , and pressure-drop effects to minimise heat generation costs in high-temperature industrial waste heat recovery syste
- 1 December 2019
- Published by Elsevier in Solar Energy
- Vol. 194, 751-765
Integrated optical-thermal-mechanical model for investigations into high temperature sodium receiver operation
- 1 December 2019
- Published by Elsevier in Solar Energy
- Vol. 194, 751-765
Integrated optical-thermal-mechanical model for investigations into high temperature sodium receiver operation
- 1 September 2019
- Published by Elsevier in Applied Energy
- Vol. 250, 1673-1685
Enhanced performance of air-cooled thermal power plants using low temperature thermal storage
- 1 September 2019
- Published by Elsevier in Applied Energy
- Vol. 250, 1673-1685
Enhanced performance of air-cooled thermal power plants using low temperature thermal storage
- 1 December 2018
- Published by Elsevier in Renewable Energy
- Vol. 129, 150-167
Thermohydraulic analysis of single phase heat transfer fluids in CSP solar receivers
- 1 December 2018
- Published by Elsevier in Renewable Energy
- Vol. 129, 150-167
Thermohydraulic analysis of single phase heat transfer fluids in CSP solar receivers
- 1 November 2018
- Published by Elsevier in Applied Energy
- Vol. 230, 590-614
Thermal and mechanical analysis of a sodium-cooled solar receiver operating under a novel heliostat aiming point strategy
- 1 November 2018
- Published by Elsevier in Applied Energy
- Vol. 230, 590-614
Thermal and mechanical analysis of a sodium-cooled solar receiver operating under a novel heliostat aiming point strategy
- 1 May 2018
- Published by Elsevier in Solar Energy
- Vol. 166, 472-485
Levelized cost of electricity evaluation of liquid sodium receiver designs through a thermal performance, mechanical reliability, and pressure drop analysis
- 1 May 2018
- Published by Elsevier in Solar Energy
- Vol. 166, 472-485
Levelized cost of electricity evaluation of liquid sodium receiver designs through a thermal performance, mechanical reliability, and pressure drop analysis
- 1 February 2016
- Published by Elsevier in International Journal of Heat and Fluid Flow
- Vol. 57, 48-57
Thermal and flow characteristics of a single-row circular-finned tube heat exchanger under elevated free-stream turbulence
- 1 February 2016
- Published by Elsevier in International Journal of Heat and Fluid Flow
- Vol. 57, 48-57
Thermal and flow characteristics of a single-row circular-finned tube heat exchanger under elevated free-stream turbulence
- 1 August 2015
- Published by Elsevier in Applied Thermal Engineering
- Vol. 87, 106-116
Pressure drop analysis of steam condensation in air-cooled circular tube bundles
- 1 August 2015
- Published by Elsevier in Applied Thermal Engineering
- Vol. 87, 106-116
Pressure drop analysis of steam condensation in air-cooled circular tube bundles