Greg Smith
Research Subjects
Research Interests
Greg Smith has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Richard Mielke
Northwest Pipe Co., Vancouver, WA, USA
2 shared publications - Brent Keil
Corporate Chief Engineer, Northwest Pipe Company, 5721 SE Columbia Way, Suite 200, Vancouver, WA 98661
1 shared publication - Shah Rahman
Senior Conveyance Engineer, CH2M Hill, 1100 112th Ave NE, Suite 400, Bellevue, WA 98004
1 shared publication
Latest Publications
- 11 June 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 30-41
Large-Diameter Transmission Pipeline Corrosion Control State-of-the-Art: Advances in the Steel Water Pipe Industry
Various studies in the past 15 years have highlighted the dire consequences of failing to proactively protect buried metallic water distribution and transmission infrastructure from the effects of corrosion. Metallic municipal pipelines are composed of cast and ductile iron, composite concrete pressure pipes, and steel pipe. For more than a hundred years, the buried steel pipe industry has employed effective corrosion protection, both on the inside and outside walls of pipelines. Lines more than 100 years old serve as testimony of the effectiveness of these systems. Both rigid cementitious and flexible dielectric corrosion barriers - combined with cathodic protection, when required - have ensured long service lives. By the 1940's, the American Water Works Association (AWWA) had published two standards for corrosion protection of steel pipes, one for cementitious systems and the other for dielectric systems. With advances in technology, many other technologies have been added to the list of standards, the most recent as recently as 2008. This paper will provide an update on the state-of-the-art lining and coating systems currently specified for steel pipe by the engineering community at large. AWWA, NACE International, and other standards-writing organizations' documents will be discussed. Focus on corrosion prevention through surface preparation for lining and coating applications, quality control, handling, repair, joint completion, and installation will be highlighted.
- 11 June 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 30-41
Large-Diameter Transmission Pipeline Corrosion Control State-of-the-Art: Advances in the Steel Water Pipe Industry
Various studies in the past 15 years have highlighted the dire consequences of failing to proactively protect buried metallic water distribution and transmission infrastructure from the effects of corrosion. Metallic municipal pipelines are composed of cast and ductile iron, composite concrete pressure pipes, and steel pipe. For more than a hundred years, the buried steel pipe industry has employed effective corrosion protection, both on the inside and outside walls of pipelines. Lines more than 100 years old serve as testimony of the effectiveness of these systems. Both rigid cementitious and flexible dielectric corrosion barriers - combined with cathodic protection, when required - have ensured long service lives. By the 1940's, the American Water Works Association (AWWA) had published two standards for corrosion protection of steel pipes, one for cementitious systems and the other for dielectric systems. With advances in technology, many other technologies have been added to the list of standards, the most recent as recently as 2008. This paper will provide an update on the state-of-the-art lining and coating systems currently specified for steel pipe by the engineering community at large. AWWA, NACE International, and other standards-writing organizations' documents will be discussed. Focus on corrosion prevention through surface preparation for lining and coating applications, quality control, handling, repair, joint completion, and installation will be highlighted.
- 17 August 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 494-504
Rehabilitation of Large Diameter PCCP: Relining and Sliplining with Steel Pipe
Failures of Prestressed Concrete Cylinder Pipe (PCCP) throughout North American municipal water transmission systems since the 1970's has led to the development of a myriad of rehabilitation technologies. Besides removing and replacing full sections of distressed pipe with new pipe, the most widely used method of rehabilitation of PCCP is the structurally independent, Type IV relining of the host pipe with steel cylinders. Referred to as Steel Cylinder Relining or Sliplining, both of these semi-trenchless technologies allow a fully structural renewal of long lengths of PCCP in an economical and expeditious manner. The differences between Relining and Sliplining are discussed from the standpoint of manufacture, flow capacities, design, planning, installation and corrosion protection. The paper also provides a description and comparison of other rehab technologies.
- 17 August 2012
- Published by American Society of Civil Engineers (ASCE)
- p. 494-504
Rehabilitation of Large Diameter PCCP: Relining and Sliplining with Steel Pipe
Failures of Prestressed Concrete Cylinder Pipe (PCCP) throughout North American municipal water transmission systems since the 1970's has led to the development of a myriad of rehabilitation technologies. Besides removing and replacing full sections of distressed pipe with new pipe, the most widely used method of rehabilitation of PCCP is the structurally independent, Type IV relining of the host pipe with steel cylinders. Referred to as Steel Cylinder Relining or Sliplining, both of these semi-trenchless technologies allow a fully structural renewal of long lengths of PCCP in an economical and expeditious manner. The differences between Relining and Sliplining are discussed from the standpoint of manufacture, flow capacities, design, planning, installation and corrosion protection. The paper also provides a description and comparison of other rehab technologies.
- 28 July 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 1-15
Steel Water Pipe Joint Testing
Steel water pipe in the municipal industry has typically been designed with either restrained or non-restrained joints, (typically rubber gaskets). Restrained joints are required where thrust at elbows, tees, laterals, wyes, reducers, valves, and dead ends. These joints are restrained by welding, harnessing and blocking. Most typical are the welded slip joint, because of its flexibility, ease in forming and laying, watertight quality and its ability to make small angle changes at each joint. The efficiency of the welded slip joints and rubber gasket joints has been tested by numerous manufactures for internal pressure. The pipe barrel will usually fail by exceeding the elastic limit of the steel prior to leaking or failure of the joint. This is due to the increased section modulus of the joint configuration and stress orientation. The ASME, recommends applying joint efficiencies of 0.45 and 0.55, respectfully for single and double-fillet lap welds and 0.9 for butt-welded pipe. The full-scale tests done by Thompson Pipe and Steel Company (1984) showed efficiencies in the 0.83 to 0.76 range for lap welded pipe. The unpublished tests at Consolidated Western Steel (1958) revealed efficiencies at nearly 1.0 for lap welded joints. Joint efficiency values are sometimes used to calculate shell thickness for buried pipelines. The question arises, what do these efficiencies mean, and how should they used in design of welded joints?
- 28 July 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 1-15
Steel Water Pipe Joint Testing
Steel water pipe in the municipal industry has typically been designed with either restrained or non-restrained joints, (typically rubber gaskets). Restrained joints are required where thrust at elbows, tees, laterals, wyes, reducers, valves, and dead ends. These joints are restrained by welding, harnessing and blocking. Most typical are the welded slip joint, because of its flexibility, ease in forming and laying, watertight quality and its ability to make small angle changes at each joint. The efficiency of the welded slip joints and rubber gasket joints has been tested by numerous manufactures for internal pressure. The pipe barrel will usually fail by exceeding the elastic limit of the steel prior to leaking or failure of the joint. This is due to the increased section modulus of the joint configuration and stress orientation. The ASME, recommends applying joint efficiencies of 0.45 and 0.55, respectfully for single and double-fillet lap welds and 0.9 for butt-welded pipe. The full-scale tests done by Thompson Pipe and Steel Company (1984) showed efficiencies in the 0.83 to 0.76 range for lap welded pipe. The unpublished tests at Consolidated Western Steel (1958) revealed efficiencies at nearly 1.0 for lap welded joints. Joint efficiency values are sometimes used to calculate shell thickness for buried pipelines. The question arises, what do these efficiencies mean, and how should they used in design of welded joints?