Giuseppe Santarpino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Giuseppe Santarpino has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Steffen Pfeiffer
Department of Cardiac Surgery, Paracelsus Medical University, Nuremberg, Germany
5 shared publicationsTheodor Fischlein
Department of Cardiac Surgery, Paracelsus Medical University, Nuremberg, Germany
5 shared publicationsFerdinand Vogt
Department of Cardiac Surgery, Paracelsus Medical University, Nuremberg, Germany
4 shared publicationsJoachim Sirch
Department of Cardiac Surgery, Paracelsus Medical University, Nuremberg, Germany
3 shared publicationsJurij M Kalisnik
2 shared publications- Steffen Pfeiffer
Department of Cardiac Surgery, Klinikum Nürnberg, Paracelsus Medical University, Nuremberg, Germany
2 shared publications
Latest Publications
- 1 July 2017
- Published by Edizioni Minerva Medica in The Journal of Cardiovascular Surgery
- Vol. 58 (5) , 731-738
Efficacy of sutureless aortic valves in minimally invasive cardiac surgery: an evolution of the surgical technique
Sutureless aortic valve prostheses have the potential of shortening surgical time, but if this results in improved clinical outcome remains to be determined. The aim of this study was to compare the outcome of patients undergoing conventional vs. minimally invasive AVR, with either a stented or sutureless bioprosthesis. From 2007 to 2015, 627 patients underwent elective isolated AVR and were divided into three groups: patients who underwent sutureless-AVR via J sternotomy (group A, N.=206) and patients who underwent stented-AVR via J sternotomy (group B, N.=247) or full-sternotomy (group C, N.=174). Patients in group A were significantly older than groups B and C (77±5 vs. 74±7 and 70±8 years; P<0.001). Aortic cross-clamp and cardiopulmonary bypass times were shorter in group A than in groups B and C. As expected, aortic cross-clamp time was prolonged in group B as compared to groups A and C (60±18 vs. 36±10 and 54±16 min; P<0.001). After multivariate adjustment, minimally invasive AVR resulted in significantly fewer postoperative complications in terms of drainage bleeding and the need for blood transfusions (385±287 vs. 500±338 mL, P=0.006; and 1.3±2.1 vs. 1.8±2.6 IU, P=0.001, respectively). No differences in postoperative outcomes were observed among groups. The minimally invasive approach confers a protective effect against bleeding complications, but it is time-consuming. The use of sutureless valves is associated with significantly shorter surgical times compared with stented bioprostheses. In addition, no differences in mortality were observed among groups, and patients who received a sutureless valve, though significantly older, showed a better clinical outcome than patients who received a stented valve.
- 1 July 2017
- Published by Edizioni Minerva Medica in The Journal of Cardiovascular Surgery
- Vol. 58 (5) , 731-738
Efficacy of sutureless aortic valves in minimally invasive cardiac surgery: an evolution of the surgical technique
Sutureless aortic valve prostheses have the potential of shortening surgical time, but if this results in improved clinical outcome remains to be determined. The aim of this study was to compare the outcome of patients undergoing conventional vs. minimally invasive AVR, with either a stented or sutureless bioprosthesis. From 2007 to 2015, 627 patients underwent elective isolated AVR and were divided into three groups: patients who underwent sutureless-AVR via J sternotomy (group A, N.=206) and patients who underwent stented-AVR via J sternotomy (group B, N.=247) or full-sternotomy (group C, N.=174). Patients in group A were significantly older than groups B and C (77±5 vs. 74±7 and 70±8 years; P<0.001). Aortic cross-clamp and cardiopulmonary bypass times were shorter in group A than in groups B and C. As expected, aortic cross-clamp time was prolonged in group B as compared to groups A and C (60±18 vs. 36±10 and 54±16 min; P<0.001). After multivariate adjustment, minimally invasive AVR resulted in significantly fewer postoperative complications in terms of drainage bleeding and the need for blood transfusions (385±287 vs. 500±338 mL, P=0.006; and 1.3±2.1 vs. 1.8±2.6 IU, P=0.001, respectively). No differences in postoperative outcomes were observed among groups. The minimally invasive approach confers a protective effect against bleeding complications, but it is time-consuming. The use of sutureless valves is associated with significantly shorter surgical times compared with stented bioprostheses. In addition, no differences in mortality were observed among groups, and patients who received a sutureless valve, though significantly older, showed a better clinical outcome than patients who received a stented valve.
- 1 January 2017
- Published by Edizioni Minerva Medica in Minerva Cardiology and Angiology
- Vol. 65 (2) , 184-192
Implantation of the Sorin Perceval® sutureless aortic valve: a step by step approach
Article: Implantation of the Sorin Perceval® sutureless aortic valve: a step by step approach - Minerva Cardioangiologica 2017 April;65(2):184-92 - Minerva Medica - Journals
- 1 January 2017
- Published by Edizioni Minerva Medica in Minerva Cardiology and Angiology
- Vol. 65 (2) , 184-192
Implantation of the Sorin Perceval® sutureless aortic valve: a step by step approach
Article: Implantation of the Sorin Perceval® sutureless aortic valve: a step by step approach - Minerva Cardioangiologica 2017 April;65(2):184-92 - Minerva Medica - Journals
- 1 January 2017
- Published by Elsevier in Seminars in Thoracic and Cardiovascular Surgery
- Vol. 29 (1) , 1-7
Sutureless Sorin Perceval Aortic Valve Implantation
- 1 January 2017
- Published by Elsevier in Seminars in Thoracic and Cardiovascular Surgery
- Vol. 29 (1) , 1-7
Sutureless Sorin Perceval Aortic Valve Implantation
- 1 October 2016
- Vol. 64 (5) , 542-51
Current knowledge and future perspectives regarding stented valves.
Aortic valve bioprostheses are commonly implanted in the current era (also in younger patients) as they may obviate the need for anticoagulation while providing better hemodynamic performance and a more favorable quality of life. The steady increase in the use of biological valves has prompted the development of several different models of conventional stented bioprostheses. At present, there are four main types of stented aortic bioprostheses that compete in the market: the LivaNova Crown PRT (LivaNova Group, Burnaby, Canada), the St. Jude Medical Trifecta (St. Jude Medical, St. Paul, MN, USA), the Carpentier-Edwards Perimount Magna Ease (Edwards Lifesciences, Irvine, CA, USA), and the Medtronic Mosaic Ultra (Medtronic, Inc., Minneapolis, MN, USA). The purpose of this review is to describe the features of these bioprosthetic valve models and to compare the data provided by the manufacturers with those derived from the available literature.
- 1 October 2016
- Vol. 64 (5) , 542-51
Current knowledge and future perspectives regarding stented valves.
Aortic valve bioprostheses are commonly implanted in the current era (also in younger patients) as they may obviate the need for anticoagulation while providing better hemodynamic performance and a more favorable quality of life. The steady increase in the use of biological valves has prompted the development of several different models of conventional stented bioprostheses. At present, there are four main types of stented aortic bioprostheses that compete in the market: the LivaNova Crown PRT (LivaNova Group, Burnaby, Canada), the St. Jude Medical Trifecta (St. Jude Medical, St. Paul, MN, USA), the Carpentier-Edwards Perimount Magna Ease (Edwards Lifesciences, Irvine, CA, USA), and the Medtronic Mosaic Ultra (Medtronic, Inc., Minneapolis, MN, USA). The purpose of this review is to describe the features of these bioprosthetic valve models and to compare the data provided by the manufacturers with those derived from the available literature.
- 20 April 2016
What's up on stented valves.
Aortic valve bioprostheses are commonly implanted in the current era - also in younger patients - as they may obviate the need for anticoagulation while providing better hemodynamic performance and a more favorable quality of life. The steady increase in the use of biological valves has prompted the development of several different models of conventional stented bioprostheses. At present, there are four main types of stented aortic bioprostheses that compete in the market: the LivaNova Crown PRT (LivaNova Group, Burnaby, Canada), the St. Jude Medical Trifecta (St. Jude Medical, St. Paul, MN), the Carpentier-Edwards Perimount Magna Ease (Edwards Lifesciences, Irvine, CA), and the Medtronic Mosaic Ultra (Medtronic, Inc., Minneapolis, MN). The purpose of this review is to describe the features of these bioprosthetic valve models and to compare the data provided by the manufacturers with those derived from the available literature.
- 20 April 2016
What's up on stented valves.
Aortic valve bioprostheses are commonly implanted in the current era - also in younger patients - as they may obviate the need for anticoagulation while providing better hemodynamic performance and a more favorable quality of life. The steady increase in the use of biological valves has prompted the development of several different models of conventional stented bioprostheses. At present, there are four main types of stented aortic bioprostheses that compete in the market: the LivaNova Crown PRT (LivaNova Group, Burnaby, Canada), the St. Jude Medical Trifecta (St. Jude Medical, St. Paul, MN), the Carpentier-Edwards Perimount Magna Ease (Edwards Lifesciences, Irvine, CA), and the Medtronic Mosaic Ultra (Medtronic, Inc., Minneapolis, MN). The purpose of this review is to describe the features of these bioprosthetic valve models and to compare the data provided by the manufacturers with those derived from the available literature.
- 1 December 2015
- Published by Elsevier in The American Journal of Cardiology
- Vol. 116 (11) , 1737-1743
Clinical Outcome and Cost Analysis of Sutureless Versus Transcatheter Aortic Valve Implantation With Propensity Score Matching Analysis
- 1 December 2015
- Published by Elsevier in The American Journal of Cardiology
- Vol. 116 (11) , 1737-1743
Clinical Outcome and Cost Analysis of Sutureless Versus Transcatheter Aortic Valve Implantation With Propensity Score Matching Analysis
- 27 November 2015
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 22 (3) , 253-258
Sutureless aortic valve replacement with Perceval bioprosthesis: are there predicting factors for postoperative pacemaker implantation?
OBJECTIVES Aortic valve replacement (AVR) with sutureless bioprostheses has become an alternative to conventional AVR for patients with intermediate to high operative risk. However, this technique is associated with an increased risk of postoperative conduction disorders. METHODS We analysed 258 patients who underwent AVR with the Perceval prosthesis from July 2010 to September 2014 at our centre. Electrocardiography were obtained at baseline to record preoperatively the presence of conduction disorders. Preoperative risk factors, intraoperative procedures and complications (61 variables) were compared between patients with permanent pacemaker (PPM group) and without (no-PPM group) need for postoperative PPM implantation. RESULTS One hundred and sixty-nine patients underwent isolated AVR with the Perceval bioprosthesis, 89 patients had associated surgery and 23 patients underwent redo operations. The mean age was 77.7 ± 5 years, 139 patients were female (46%) and the mean logistic EuroSCORE was 13.2 ± 11%. At baseline, 8 patients had already an implanted pacemaker. Postoperatively, 27 patients (10.5%) required new PPM implantation due to complete atrioventricular block. On univariate analysis, age (PPM vs no-PPM group: 80 ± 5 vs 77 ± 5 years, P = 0.009) and preoperative presence of right bundle branch block (RBBB) [overall n = 20 (7.8%); PPM vs no-PPM group: 9 vs 11 (33 vs 4.8%); P < 0.001] were identified as independent predictors of postoperative conduction disorders, but only pre-existing RBBB persisted on multivariate analysis (odds ratio 11.3—C-statistic 0.74, error estimate 0.064, confidence interval 0.672–0.801; P = 0.0002). Among patients undergoing sutureless AVR, the rate of PPM implantation was high. CONCLUSIONS The analysis of the data collected made it possible to identify preoperatively a subset of patients undergoing sutureless AVR at higher risk of postoperative atrioventricular block. Additional surgical precautions should be implemented to prevent the occurrence of conduction disorders after sutureless AVR.
- 27 November 2015
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 22 (3) , 253-258
Sutureless aortic valve replacement with Perceval bioprosthesis: are there predicting factors for postoperative pacemaker implantation?
OBJECTIVES Aortic valve replacement (AVR) with sutureless bioprostheses has become an alternative to conventional AVR for patients with intermediate to high operative risk. However, this technique is associated with an increased risk of postoperative conduction disorders. METHODS We analysed 258 patients who underwent AVR with the Perceval prosthesis from July 2010 to September 2014 at our centre. Electrocardiography were obtained at baseline to record preoperatively the presence of conduction disorders. Preoperative risk factors, intraoperative procedures and complications (61 variables) were compared between patients with permanent pacemaker (PPM group) and without (no-PPM group) need for postoperative PPM implantation. RESULTS One hundred and sixty-nine patients underwent isolated AVR with the Perceval bioprosthesis, 89 patients had associated surgery and 23 patients underwent redo operations. The mean age was 77.7 ± 5 years, 139 patients were female (46%) and the mean logistic EuroSCORE was 13.2 ± 11%. At baseline, 8 patients had already an implanted pacemaker. Postoperatively, 27 patients (10.5%) required new PPM implantation due to complete atrioventricular block. On univariate analysis, age (PPM vs no-PPM group: 80 ± 5 vs 77 ± 5 years, P = 0.009) and preoperative presence of right bundle branch block (RBBB) [overall n = 20 (7.8%); PPM vs no-PPM group: 9 vs 11 (33 vs 4.8%); P < 0.001] were identified as independent predictors of postoperative conduction disorders, but only pre-existing RBBB persisted on multivariate analysis (odds ratio 11.3—C-statistic 0.74, error estimate 0.064, confidence interval 0.672–0.801; P = 0.0002). Among patients undergoing sutureless AVR, the rate of PPM implantation was high. CONCLUSIONS The analysis of the data collected made it possible to identify preoperatively a subset of patients undergoing sutureless AVR at higher risk of postoperative atrioventricular block. Additional surgical precautions should be implemented to prevent the occurrence of conduction disorders after sutureless AVR.