SPSteffen Pfeiffer

Steffen Pfeiffer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steffen Pfeiffer has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Patterns of use and durability for the Mitroflow aortic valve: a systematic review of the literature

    by Theodor Fischlein, Steffen Pfeiffer, Vincenzo Bagnardi, Giuseppe Santarpino

    The aim of this study was to evaluate durability of Mitroflow and patterns of use compared with other aortic valves through a systematic review of the literature. A total of 52 papers that included 33,630 patients met eligibility requirements that allowed summary statistical information to be determined regarding structural valve degeneration risk. Mitroflow has been disporportionately implanted in patients to be at higher risk for structural valve degeneration. Since Mitroflow valves were implanted more often in these high-risk patients, it was impossible to distinguish the effects of valve size or gender from valve type on structural valve degeneration risk.


    • 1 May 2017
      • Vol. 26  (3) , 255-261

    Sutureless versus Transfemoral Transcatheter Aortic Valve Implant: A Propensity Score Matching Study.

    by Giuseppe Santarpino, Ferdinand Vogt, Steffen Pfeiffer, Angelo M Dell'aquila, Jürgen Jessl, Federica Cuomo, Che Von Wardenburg, Theodor Fischlein, Matthias Pauschinger, Johannes Schwab

    Transcatheter aortic valve implantation (TAVI), especially via the transfemoral (TF) route, is increasingly performed in patients considered in the 'gray zone' between TAVI and surgery. However, the best treatment option in this patient population remains to be established. Since 2010, a total of 923 patients underwent either TAVI (n = 538) or sutureless aortic valve replacement (AVR) (n = 385) at the authors' institutions. Among these patients, 79 treated with TF-TAVI were compared with 79 propensity score-matched patients who had undergone elective isolated AVR with the sutureless Perceval bioprosthesis. In-hospital mortality did not differ significantly between patients who underwent sutureless AVR or TF-TAVI (none versus three; 3.8%; p = 0.123). Similarly, postoperative complications were comparable between groups. Atrioventricular block requiring postoperative pacemaker implantation occurred in seven patients (9.2%) of the sutureless group and in eight patients (11.1%) of the TF-TAVI group (p = 0.455). The use of blood products varied between groups in terms of red blood cell transfusions (1.7 ± 2 versus 0.3 ± 0.9 units for the sutureless group versus TF-TAVI group; p <0.001). Paravalvular leakage at discharge was present in three patients (3.8%) in the sutureless group and in 26 patients (32.9%) in the TF-TAVI group (p <0.001). The mean follow up was longer for sutureless AVR (36 ± 21 versus 27 ± 20 months; p = 0.003). Survival rates were 97.5% and 84.8% in the sutureless and TF-TAVI groups, respectively (p = 0.001). Both, TF-TAVI and sutureless AVR are well-standardized, safe and effective procedures. TF-TAVI seems to be a valuable alternative to surgical AVR for frail patients, reducing the need for perioperative blood transfusion. In contrast, in patients with a favorable long-term survival outcome, minimally invasive AVR remains the procedure of choice as it is associated with better long-term results.


    • 1 October 2016
      • Vol. 64  (5) , 542-51

    Current knowledge and future perspectives regarding stented valves.

    by Giuseppe Santarpino, Jurij M Kalisnik, Theodor Fischlein, Steffen Pfeiffer

    Aortic valve bioprostheses are commonly implanted in the current era (also in younger patients) as they may obviate the need for anticoagulation while providing better hemodynamic performance and a more favorable quality of life. The steady increase in the use of biological valves has prompted the development of several different models of conventional stented bioprostheses. At present, there are four main types of stented aortic bioprostheses that compete in the market: the LivaNova Crown PRT (LivaNova Group, Burnaby, Canada), the St. Jude Medical Trifecta (St. Jude Medical, St. Paul, MN, USA), the Carpentier-Edwards Perimount Magna Ease (Edwards Lifesciences, Irvine, CA, USA), and the Medtronic Mosaic Ultra (Medtronic, Inc., Minneapolis, MN, USA). The purpose of this review is to describe the features of these bioprosthetic valve models and to compare the data provided by the manufacturers with those derived from the available literature.

    • 20 April 2016

    What's up on stented valves.

    by Giuseppe Santarpino, Jurij M Kalisnik, Theodor Fischlein, Steffen Pfeiffer

    Aortic valve bioprostheses are commonly implanted in the current era - also in younger patients - as they may obviate the need for anticoagulation while providing better hemodynamic performance and a more favorable quality of life. The steady increase in the use of biological valves has prompted the development of several different models of conventional stented bioprostheses. At present, there are four main types of stented aortic bioprostheses that compete in the market: the LivaNova Crown PRT (LivaNova Group, Burnaby, Canada), the St. Jude Medical Trifecta (St. Jude Medical, St. Paul, MN), the Carpentier-Edwards Perimount Magna Ease (Edwards Lifesciences, Irvine, CA), and the Medtronic Mosaic Ultra (Medtronic, Inc., Minneapolis, MN). The purpose of this review is to describe the features of these bioprosthetic valve models and to compare the data provided by the manufacturers with those derived from the available literature.

    • 1 September 2013
      • Vol. 22  (5) , 615-20

    REDO aortic valve replacement: the sutureless approach.

    by Giuseppe Santarpino, Steffen Pfeiffer, Giovanni Concistrè, Theodor Fischlein

    The study aim was to report the results of a single-center cohort of patients who underwent aortic valve replacement (AVR) with a sutureless prosthesis in case of cardiac reoperation (REDO). Between March 2010 and December 2011, a total of 83 patients underwent AVR with the Perceval S sutureless aortic bioprosthesis (Sorin Biomedica Cardio Srl, Saluggia, Italy) at the authors' institution. Thirteen of these patients (six males, seven females; mean age 75.2 +/- 5.6 years) had previously undergone cardiac surgery and represented the study population. Preoperative, periprocedural and echocardiographic parameters, as well as clinical outcomes, were analyzed for all patients. The primary procedure was AVR, using a bioprosthesis in six patients (46%) and coronary artery bypass grafting in seven (54%). The logistic EuroSCORE was 19.4 +/- 10.7%. Surgery was always performed via a full sternotomy; the mean implanted valve size was 23.6 +/- 1.3 mm (the previous valve size was 23.2 +/- 3.2 mm; p = 0.66). The mean cross-clamp time was 44 +/- 16 min, and the mean intensive care unit stay was 3.3 +/- 2.3 days. No intraoperative or in-hospital deaths occurred, and all patients were alive at a mean follow up of 8.5 months. Two postoperative events included transient ischemic attack in one patient, and the need for pacemaker implantation in one patient. On echocardiographic evaluation, no patient showed signs of paraprosthetic leak. The mean transvalvular gradient was 10.3 +/- 1.5 mmHg. Use of the Perceval S sutureless AVR offers a fast and safe procedure, even in high-risk REDO surgery, providing a good hemodynamic performance with excellent clinical recovery, demonstrated at a follow up of six months. Although the sample size was limited, the results were encouraging and support the use of sutureless valves in the frame of REDO surgery for aortic valve disease.


    • 1 July 2013
      • Vol. 22  (4) , 455-9

    Advanced age per se should not be an exclusion criterion for minimally invasive aortic valve replacement.

    by Giuseppe Santarpino, Steffen Pfeiffer, Ferdinand Vogt, Martin Hinzmann, Giovanni Concistrè, Theodor Fischlein

    The introduction of transcatheter aortic valve implantation (TAVI), coupled with the increasing number of elderly patients requiring cardiac surgery, has given rise to an intense debate on the most appropriate treatment strategy for this high-risk population. The study aim was to compare clinical outcomes in older versus younger patients undergoing minimally invasive aortic valve replacement (AVR). Between March 2010 and July 2012, 66 patients undergoing minimally invasive isolated AVR with the sutureless Perceval S bioprosthesis (Sorin Group, Saluggia, Italy) were allocated to two groups according to age > or = 80 years (group A, n = 25) or < 80 years (group B, n = 41). In-hospital and follow up data were collected for all patients, including an evaluation of the patients' quality of life, using the SF-36 questionnaire. Mean age and logistic EuroSCORE were statistically different between groups (p < 0.001 and p = 0.002, respectively). The length of intensive care unit stay was similar in groups A and B (1.9 +/- 0.8 and 2.5 +/- 1.4 days, respectively; p = 0.061). In-hospital mortality occurred in only one patient of group A (1.5%). Postoperative transient cerebral ischemic events occurred with similar frequency in both groups (two in group A and four in group B; p = 0.59). One patient in group A and two patients in group B required pacemaker implantation (1.5 versus 3%; p = 0.68). The mean follow up was 13.9 +/- 7.4 months, during which time three patients died (two in group A, one in group B). All enrolled patients answered the SF-36 questionnaire, and there were no significant differences between groups in all eight domains of the test. Within the setting of minimally invasive isolated AVR, the study results showed that the clinical outcomes and quality of life in patients aged > or = 80 years were comparable to those of younger patients. Therefore, advanced age per se does not preclude successful AVR through a minimally invasive approach.