Vivien Lacour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Vivien Lacour has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jean-François Manceau
Lab. de Phys. et Metrol. des Oscillateurs, CNRS, Besancon, France
2 shared publications - Thérèse Leblois
FEMTO-ST Institute, CNRS UMR-6174, Université de Bourgogne Franche-Comté, 25030 Besançon, France
2 shared publications - Charles-Louis Azzopardi
CNRS, Institut FEMTO-ST, Université Marie et Louis Pasteur, 25000 Besançon, France
1 shared publication - Dimitri Bonnet
FEMTO-ST Institute, Univ. Bourgogne Franche-Comté, CNRS, 15B Avenue des Montboucons, 25030 Besançon, Cedex, France
1 shared publication - Franck Chollet
FEMTO-ST Institute, Université Bourgogne Franche-Comté, CNRS UMR 6174, 15B Avenue des Montboucons, 25030 Besançon cedex, France
1 shared publication - Magali Barthès
FEMTO-ST Institute, Univ. Bourgogne Franche-Comté, CNRS, 15B Avenue des Montboucons, 25030 Besançon, Cedex, France
1 shared publication
Latest Publications
- Open Access
- 14 October 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (10) , 308
A Fluidic Interface with High Flow Uniformity for Reusable Large Area Resonant Biosensors
Resonant biosensors are known for their high accuracy and high level of miniaturization. However, their fabrication costs prevent them from being used as disposable sensors and their effective commercial success will depend on their ability to be reused repeatedly. Accordingly, all the parts of the sensor in contact with the fluid need to tolerate the regenerative process which uses different chemicals (H3PO4, H2SO4 based baths) without degrading the characteristics of the sensor. In this paper, we propose a fluidic interface that can meet these requirements, and control the liquid flow uniformity at the surface of the vibrating area. We study different inlet and outlet channel configurations, estimating their performance using numerical simulations based on finite element method (FEM). The interfaces were fabricated using wet chemical etching on Si, which has all the desirable characteristics for a reusable biosensor circuit. Using a glass cover, we could observe the circulation of liquid near the active surface, and by using micro-particle image velocimetry (μPIV) on large surface area we could verify experimentally the effectiveness of the different designs and compare with simulation results.
- 14 October 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (10) , 308
Open AccessA Fluidic Interface with High Flow Uniformity for Reusable Large Area Resonant Biosensors
Resonant biosensors are known for their high accuracy and high level of miniaturization. However, their fabrication costs prevent them from being used as disposable sensors and their effective commercial success will depend on their ability to be reused repeatedly. Accordingly, all the parts of the sensor in contact with the fluid need to tolerate the regenerative process which uses different chemicals (H3PO4, H2SO4 based baths) without degrading the characteristics of the sensor. In this paper, we propose a fluidic interface that can meet these requirements, and control the liquid flow uniformity at the surface of the vibrating area. We study different inlet and outlet channel configurations, estimating their performance using numerical simulations based on finite element method (FEM). The interfaces were fabricated using wet chemical etching on Si, which has all the desirable characteristics for a reusable biosensor circuit. Using a glass cover, we could observe the circulation of liquid near the active surface, and by using micro-particle image velocimetry (μPIV) on large surface area we could verify experimentally the effectiveness of the different designs and compare with simulation results.
- Open Access
- 5 November 2015
- Published by MDPI AG
GaAs Lamb wave micro sensor
Acoustic Lamb Wave microsensors are suitable for label free sensing in liquid. The device relies on the interaction between acoustic waves propagating within a thin membrane and the liquid. Lamb wave sensors have been previously studied using AlN/Si structure to detect multi-parameters of a liquid, such as its temperature, density, sound velocity and viscosity using various modes as A0 and S0. These devices already showed good ability to perform measurements on fluids (gas or liquid) but in this case, chemical wet etching silicon was used to realize thin membranes combined with an Aln piezoelectric layer used to generate and detect the acoustic wave. This paper reports the use of Gallium Arsenide as piezoelectric material to generate and propagate Lamb waves. GaAs material presents intrinsically interesting piezoelectric properties and is compatible with wet chemical etching process. The fabrication process allows producing a thin membrane but is also adapted for microfluidic microchannels. So, the same substrate can be used for the resonant structure and its excitation. The design of the resonant structure has been optimized using simulations to adapt the design of interdigital electrodes to the GaAs substrate taking into account the shear piezoelectric coefficient and its orientation. An experimental setup has been realized and measurements of the interaction with fluids are presented.
- 5 November 2015
- Published by MDPI AG
Open AccessGaAs Lamb wave micro sensor
Acoustic Lamb Wave microsensors are suitable for label free sensing in liquid. The device relies on the interaction between acoustic waves propagating within a thin membrane and the liquid. Lamb wave sensors have been previously studied using AlN/Si structure to detect multi-parameters of a liquid, such as its temperature, density, sound velocity and viscosity using various modes as A0 and S0. These devices already showed good ability to perform measurements on fluids (gas or liquid) but in this case, chemical wet etching silicon was used to realize thin membranes combined with an Aln piezoelectric layer used to generate and detect the acoustic wave. This paper reports the use of Gallium Arsenide as piezoelectric material to generate and propagate Lamb waves. GaAs material presents intrinsically interesting piezoelectric properties and is compatible with wet chemical etching process. The fabrication process allows producing a thin membrane but is also adapted for microfluidic microchannels. So, the same substrate can be used for the resonant structure and its excitation. The design of the resonant structure has been optimized using simulations to adapt the design of interdigital electrodes to the GaAs substrate taking into account the shear piezoelectric coefficient and its orientation. An experimental setup has been realized and measurements of the interaction with fluids are presented.