Da-Kai Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Da-Kai Liang has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Jie Zeng
Nanjing University of Aeronautics and Astronautics , China
10 shared publications- Jie Zeng
College of Aerospace Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
4 shared publications Xiao-Li Zhang
3 shared publicationsH. Wu
Key Laboratory of Nondestructive Test (Ministry of Education), School of Measuring and Optical Engineering, Nanchang Hangkong University, Nanchang 330063, China
2 shared publicationsJian-Min Zeng
2 shared publicationsL. Huang
State Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
2 shared publications
Latest Publications
- 10 December 2020
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 64 (1-4) , 137-145
Helicopter main reduction planetary gear fault diagnosis method based on SVDD
Aiming at the irregularity of the fault characteristics of the helicopter main reducer planetary gear, a fault diagnosis method based on support vector data description (SVDD) is proposed. The working condition of the helicopter is complex and changeable, and the fault characteristics of the planetary gear also show irregularity with the change of working conditions. It is impossible to diagnose the fault by the regularity of a single fault feature; so a method of SVDD based on Gaussian kernel function is used. By connecting the energy characteristics and fault characteristics of the helicopter main reducer running state signal and performing vector quantization, the planetary gear of the helicopter main reducer is characterized, and simultaneously couple the multi-channel information, which can accurately characterize the operational state of the planetary gear’s state.
- 10 December 2020
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 64 (1-4) , 137-145
Helicopter main reduction planetary gear fault diagnosis method based on SVDD
Aiming at the irregularity of the fault characteristics of the helicopter main reducer planetary gear, a fault diagnosis method based on support vector data description (SVDD) is proposed. The working condition of the helicopter is complex and changeable, and the fault characteristics of the planetary gear also show irregularity with the change of working conditions. It is impossible to diagnose the fault by the regularity of a single fault feature; so a method of SVDD based on Gaussian kernel function is used. By connecting the energy characteristics and fault characteristics of the helicopter main reducer running state signal and performing vector quantization, the planetary gear of the helicopter main reducer is characterized, and simultaneously couple the multi-channel information, which can accurately characterize the operational state of the planetary gear’s state.
- Open Access
- 18 December 2019
- Published by MDPI AG in Applied Sciences
- Vol. 10 (1) , 18
Measurement of Structural Loads Using a Novel MEMS Extrinsic Fabry–Perot Strain Sensor
In this paper, microelectromechanical systems (MEMS) technology was used to fabricate a novel extrinsic fiber Fabry–Perot (EFFP) strain sensor; this fiber sensor is applied to measure load with higher precision for a small structure. The sensor cavity consists of two Fabry–Perot (FP) cavity mirrors that are processed by surface micromachining and then fused and spliced together by the silicon–glass anode bonding process. The initial cavity length can be strictly controlled, and the excellent parallelism of the two faces of the cavity results in a high interference fineness. Then, the anti-reflection coating process is applied to the sensor to improve the clarity of the interference signal with the cavity, with its wavelength working within the range of the C + L band. Next, the sensor placement is determined by the finite element software Nastran. Experimental results indicate that the sensor exhibits a good linear response (99.77%) to load changes and a high repeatability. Considering the strain transfer coefficient, the sensitivity for the tested structure load is as high as 35.6 pm/N. Due to the miniaturization, repeatability, and easy-to-batch production, the proposed sensor can be used as a reliable and practical force sensor.
- 18 December 2019
- Published by MDPI AG in Applied Sciences
- Vol. 10 (1) , 18
Open AccessMeasurement of Structural Loads Using a Novel MEMS Extrinsic Fabry–Perot Strain Sensor
In this paper, microelectromechanical systems (MEMS) technology was used to fabricate a novel extrinsic fiber Fabry–Perot (EFFP) strain sensor; this fiber sensor is applied to measure load with higher precision for a small structure. The sensor cavity consists of two Fabry–Perot (FP) cavity mirrors that are processed by surface micromachining and then fused and spliced together by the silicon–glass anode bonding process. The initial cavity length can be strictly controlled, and the excellent parallelism of the two faces of the cavity results in a high interference fineness. Then, the anti-reflection coating process is applied to the sensor to improve the clarity of the interference signal with the cavity, with its wavelength working within the range of the C + L band. Next, the sensor placement is determined by the finite element software Nastran. Experimental results indicate that the sensor exhibits a good linear response (99.77%) to load changes and a high repeatability. Considering the strain transfer coefficient, the sensitivity for the tested structure load is as high as 35.6 pm/N. Due to the miniaturization, repeatability, and easy-to-batch production, the proposed sensor can be used as a reliable and practical force sensor.
- Open Access
- 12 March 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (5) , 1018
Influence of Initial Phase Modulation on the Sensitivity of the Optical Fiber Sagnac Acoustic Emission Sensor
Improving the phase sensitivity of the optical fiber Sagnac sensor is very important for accurately detecting weak signals of acoustic emission. Theoretical analysis shows that the initial phase of the sensor is π under ideal conditions, and the maximum phase sensitivity is obtained when the bias phase is π/2. In this work, an experimental system was built with an aluminum alloy plate as the experimental object. The initial phase of the sensor was modulated by a Y-branch waveguide, and the fitting curve of the experimental data was in good agreement with the curve of the numerical simulation. Moreover, our experiments show there was a single value for the bias phase of π/2, which significantly deviated from the theoretical value. The results show that the greatest phase sensitivity of the sensor not only could be increased by nearly nine times through modulating the initial phase, but also could suppress the harmonic interferences in the sensing system. This study can provide a useful reference for improving the phase sensitivity of the optical fiber Sagnac AE sensor in practical applications.
- 12 March 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (5) , 1018
Open AccessInfluence of Initial Phase Modulation on the Sensitivity of the Optical Fiber Sagnac Acoustic Emission Sensor
Improving the phase sensitivity of the optical fiber Sagnac sensor is very important for accurately detecting weak signals of acoustic emission. Theoretical analysis shows that the initial phase of the sensor is π under ideal conditions, and the maximum phase sensitivity is obtained when the bias phase is π/2. In this work, an experimental system was built with an aluminum alloy plate as the experimental object. The initial phase of the sensor was modulated by a Y-branch waveguide, and the fitting curve of the experimental data was in good agreement with the curve of the numerical simulation. Moreover, our experiments show there was a single value for the bias phase of π/2, which significantly deviated from the theoretical value. The results show that the greatest phase sensitivity of the sensor not only could be increased by nearly nine times through modulating the initial phase, but also could suppress the harmonic interferences in the sensing system. This study can provide a useful reference for improving the phase sensitivity of the optical fiber Sagnac AE sensor in practical applications.
- 31 October 2015
- Published by Elsevier in Optics & Laser Technology
- Vol. 78, 79-82
A silicon-based wideband multisubpart profile grating reflector
- 31 October 2015
- Published by Elsevier in Optics & Laser Technology
- Vol. 78, 79-82
A silicon-based wideband multisubpart profile grating reflector
- 16 October 2015
- Published by Elsevier in Optics & Laser Technology
- Vol. 78, 1-4
SOI-based high performance multi-subpart profile grating mirror
- 16 October 2015
- Published by Elsevier in Optics & Laser Technology
- Vol. 78, 1-4
SOI-based high performance multi-subpart profile grating mirror
- 1 December 2013
- Vol. 33 (12) , 3273-7
[Study on the axial strain sensor of birefringence photonic crystal fiber loop mirror based on the absolute integral of the monitoring peak].
In the present paper, the theoretical expression of the wavelength change and the axial strain of birefringence fiber loop mirror is developed. The theoretical result shows that the axial strain sensitivity of birefringence photonic crystal fiber loop mirror is much lower than conventional birefringence fiber loop mirror. It is difficult to measure the axial strain by monitoring the wavelength change of birefringence photonic crystal fiber loop mirror, and it is easy to cause the measurement error because the output spectrum is not perfectly smooth. The different strain spectrum of birefringence photonic crystal fiber loop mirror was measured experimentally by an optical spectrum analyzer. The measured spectrum was analysed. The results show that the absolute integral of the monitoring peak decreases with increasing strain and the absolute integral is linear versus strain. Based on the above results, it is proposed that the axial strain can be measured by monitoring the absolute integral of the monitoring peak in this paper. The absolute integral of the monitoring peak is a comprehensive index which can indicate the light intensity of different wavelength. This method of monitoring the absolute integral of the monitoring peak to measure the axial strain can not only overcome the difficulty of monitoring the wavelength change of birefringence photonic crystal fiber loop mirror, but also reduce the measurement error caused by the unsmooth output spectrum.
- 1 December 2013
- Vol. 33 (12) , 3273-7
[Study on the axial strain sensor of birefringence photonic crystal fiber loop mirror based on the absolute integral of the monitoring peak].
In the present paper, the theoretical expression of the wavelength change and the axial strain of birefringence fiber loop mirror is developed. The theoretical result shows that the axial strain sensitivity of birefringence photonic crystal fiber loop mirror is much lower than conventional birefringence fiber loop mirror. It is difficult to measure the axial strain by monitoring the wavelength change of birefringence photonic crystal fiber loop mirror, and it is easy to cause the measurement error because the output spectrum is not perfectly smooth. The different strain spectrum of birefringence photonic crystal fiber loop mirror was measured experimentally by an optical spectrum analyzer. The measured spectrum was analysed. The results show that the absolute integral of the monitoring peak decreases with increasing strain and the absolute integral is linear versus strain. Based on the above results, it is proposed that the axial strain can be measured by monitoring the absolute integral of the monitoring peak in this paper. The absolute integral of the monitoring peak is a comprehensive index which can indicate the light intensity of different wavelength. This method of monitoring the absolute integral of the monitoring peak to measure the axial strain can not only overcome the difficulty of monitoring the wavelength change of birefringence photonic crystal fiber loop mirror, but also reduce the measurement error caused by the unsmooth output spectrum.
- 1 January 2013
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 62 (6) , 064216
Influence of monitoring point wavelength on axial strain sensitivity of high-birefringence fiber loop mirror
研究了高双折射光纤环镜监测点波长对轴向应变灵敏度的影响. 经理论推导得出高双折射光纤环镜轴向应变灵敏度公式. 结果表明: 当高双折射光纤材料选定后, 灵敏度随着监测点波长的增大而增大; 当监测点选定后, 监测点的灵敏度为常数, 波长变化与应变成线性关系. 实验选取不同波长的波峰进行应变灵敏度监测, 对各监测点进行数据拟合, 实验结果与理论分析一致. 研究结果对提高高双折射光纤环镜应变、温度等灵敏度具有指导意义.
- 1 January 2013
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 62 (6) , 064216
Influence of monitoring point wavelength on axial strain sensitivity of high-birefringence fiber loop mirror
研究了高双折射光纤环镜监测点波长对轴向应变灵敏度的影响. 经理论推导得出高双折射光纤环镜轴向应变灵敏度公式. 结果表明: 当高双折射光纤材料选定后, 灵敏度随着监测点波长的增大而增大; 当监测点选定后, 监测点的灵敏度为常数, 波长变化与应变成线性关系. 实验选取不同波长的波峰进行应变灵敏度监测, 对各监测点进行数据拟合, 实验结果与理论分析一致. 研究结果对提高高双折射光纤环镜应变、温度等灵敏度具有指导意义.
- 1 December 2012
- Vol. 32 (12) , 3367-71
[Research on axial strain sensitivity of high-birefringence fiber loop mirror].
In the present paper, the theoretical expressions for the axial strain sensitivity of high-birefringence fiber loop mirror (Hi-Bi FLM) was developed. The key influence factors on the axial strain sensitivity are discussed for the same input light source as the high-birefringence fiber material is certain, including the high-birefringence fiber length and the sensing length. The relationship between the high-birefringence fiber material and the axial strain sensitivity is discussed for the same input light source. The results show that the wavelength shift of high-birefringence fiber loop mirror is linear with the axial strain, and the linear sensitivity is constant decided by the high-birefringence fiber material and the center wavelength of input light source, having nothing to do with the high-birefringence fiber length and the sensing length.
- 1 December 2012
- Vol. 32 (12) , 3367-71
[Research on axial strain sensitivity of high-birefringence fiber loop mirror].
In the present paper, the theoretical expressions for the axial strain sensitivity of high-birefringence fiber loop mirror (Hi-Bi FLM) was developed. The key influence factors on the axial strain sensitivity are discussed for the same input light source as the high-birefringence fiber material is certain, including the high-birefringence fiber length and the sensing length. The relationship between the high-birefringence fiber material and the axial strain sensitivity is discussed for the same input light source. The results show that the wavelength shift of high-birefringence fiber loop mirror is linear with the axial strain, and the linear sensitivity is constant decided by the high-birefringence fiber material and the center wavelength of input light source, having nothing to do with the high-birefringence fiber length and the sensing length.
- 1 November 2012
- Vol. 32 (11) , 2929-34
[Surface plasmon resonance spectral based fiber optic sensor for detection of total dissolved solids in water quality analysis].
As surface plasmon resonance (SPR) spectrum is sensitive to refractive index of the mediums, we explored its sensitivity characteristic of ions composition detection in a solution so as to measure the total dissolved solid value in water. Seven ionic (NaCl, KCl, CaCl2, MgCl2, Na2CO3, MgSO4 and ZnSO4) and 3 non-ionic (glucose, glycerol and sucrose) liquid samples were studied experimentally with a fiber optic SPR sensor. The influence of ion concentration on the resonance wavelength shift in SPR spectrum was investigated and discussed, and with that, the response curves were established to realize the detection of total dissolved solid in water quality analysis. The FO-SPR sensor spectral curve for TDS measurement was in conformity with ionic conductivity in 8 different water samples, and results show that the spectral method was better in high ion concentration detection of water. This research will broaden the SPR application in the field of water quality monitoring.
- 1 November 2012
- Vol. 32 (11) , 2929-34
[Surface plasmon resonance spectral based fiber optic sensor for detection of total dissolved solids in water quality analysis].
As surface plasmon resonance (SPR) spectrum is sensitive to refractive index of the mediums, we explored its sensitivity characteristic of ions composition detection in a solution so as to measure the total dissolved solid value in water. Seven ionic (NaCl, KCl, CaCl2, MgCl2, Na2CO3, MgSO4 and ZnSO4) and 3 non-ionic (glucose, glycerol and sucrose) liquid samples were studied experimentally with a fiber optic SPR sensor. The influence of ion concentration on the resonance wavelength shift in SPR spectrum was investigated and discussed, and with that, the response curves were established to realize the detection of total dissolved solid in water quality analysis. The FO-SPR sensor spectral curve for TDS measurement was in conformity with ionic conductivity in 8 different water samples, and results show that the spectral method was better in high ion concentration detection of water. This research will broaden the SPR application in the field of water quality monitoring.
- 1 February 2012
- Vol. 32 (2) , 402-6
[Research on optical fiber SPR humidity sensor and resonance spectrum characteristic].
A new type of humidity sensor based on optical fiber SPR sensor probe was introduced and manufactured. Firstly the sensitivity of optical fiber SPR sensor probe to environment humidity was studied. On this basis, coating with thin PVA film of different thickness and with capacity of adsorbing water molecule on the surface of optical fiber SPR sensor probe, for the purpose of monitoring relative humidity was proposed. The research shows that the SPR sensor probe coated with double layers of thin PVA film gets better detection result, and humidity measurement sensitivity is 1.59%/%RH, being improved notably compared with SPR optical fiber probe. The SPR sensor coated with single layer of thin PVA film has relative humidity measuring sensitivity of 2.411 nm/%RH related to resonance wavelength in high humidity area. In addition, the new type of optical fiber humidity-sensitive probe with PVA film losing efficiency can be reusable after special treatment.
- 1 February 2012
- Vol. 32 (2) , 402-6
[Research on optical fiber SPR humidity sensor and resonance spectrum characteristic].
A new type of humidity sensor based on optical fiber SPR sensor probe was introduced and manufactured. Firstly the sensitivity of optical fiber SPR sensor probe to environment humidity was studied. On this basis, coating with thin PVA film of different thickness and with capacity of adsorbing water molecule on the surface of optical fiber SPR sensor probe, for the purpose of monitoring relative humidity was proposed. The research shows that the SPR sensor probe coated with double layers of thin PVA film gets better detection result, and humidity measurement sensitivity is 1.59%/%RH, being improved notably compared with SPR optical fiber probe. The SPR sensor coated with single layer of thin PVA film has relative humidity measuring sensitivity of 2.411 nm/%RH related to resonance wavelength in high humidity area. In addition, the new type of optical fiber humidity-sensitive probe with PVA film losing efficiency can be reusable after special treatment.