MDMohammad Reza Deevband

Mohammad Reza Deevband

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohammad Reza Deevband has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Mohammad Reza Kardan

    Nuclear Science and Technology Research Institute, Tehran, Iran

    2 shared publications
  • Abolhasan Divband

    Department of Pediatrics, Faculty of Medicine College/Hormozgan University of Medical Science Bandar Abbas Iran

    1 shared publication
  • Ahmad Mostaar

    Department of Medical Physics and Biomedical Engineering, Faculty of Medicine Shahid Beheshti University of Medical Sciences and Health Services Tehran Iran

    1 shared publication
  • Ali Akbar Salehi

    Department of Energy Engineering, Sharif University of Technology, Tehran, Iran

    1 shared publication
  • Faranak Sadeghi Pour

    Biomedical Engineering and Medical Physics Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran

    1 shared publication
  • Habib Mohammadi

    Department of Medical Physics and Biomedical Engineering, Faculty of Medicine Shahid Beheshti University of Medical Sciences and Health Services Tehran Iran

    1 shared publication

Latest Publications

  • Open Access

    Introducing fitting models for estimating age‐specific dose and effective dose in paediatric patients undergoing head, chest and abdomen–pelvis imaging protocols: a patient study

    by Mohammad Reza Deevband, Habib Mohammadi, Yazdan Salimi, Ahmad Mostaar, Niloofar Deravi, Mobina Fathi, Kimia Vakili, Shirin Yaghoobpoor, Mehdi Ghorbani, Abolhasan Divband, et al.

    Introduction: Concerns regarding the adverse consequences of radiation have increased due to the expanded application of computed tomography (CT) in medical practice. Certain studies have indicated that the radiation dosage depends on the anatomical region, the imaging technique employed and patient‐specific variables. The aim of this study is to present fitting models for the estimation of age‐specific dose estimates (ASDE), in the same direction of size‐specific dose estimates, and effective doses based on patient age, gender and the type of CT examination used in paediatric head, chest and abdomen–pelvis imaging.Methods: A total of 583 paediatric patients were included in the study. Radiometric data were gathered from DICOM files. The patients were categorised into five distinct groups (under 15 years of age), and the effective dose, organ dose and ASDE were computed for the CT examinations involving the head, chest and abdomen–pelvis. Finally, the best fitting models were presented for estimation of ASDE and effective doses based on patient age, gender and the type of examination.Results: The ASDE in head, chest, and abdomen–pelvis CT examinations increases with increasing age. As age increases, the effective dose in head and abdomen–pelvis CT scans decreased. However, for chest scans, the effective dose initially showed a decreasing trend until the first year of life; after that, it increases in correlation with age.Conclusions: Based on the presented fitting model for the ASDE, these CT scan quantities depend on factors such as patient age and the type of CT examination. For the effective dose, the gender was also included in the fitting model. By utilising the information about the scan type, region and age, it becomes feasible to estimate the ASDE and effective dose using the models provided in this study.


  • Open Access

    Incidence risk assessment of secondary cancer due to radiotherapy of women with rectal cancer using BEIR VII, EPA, and ICRP models

    by Rowaidah Hamzah, Mohammad Reza Deevband, Mahdi Ghorbani, Mehdi Khosravi, Faranak Sadeghi Pour

    Background: Radiotherapy has a significant side effect known as radiation-induced secondary cancer. This study aims to evaluate the dose and secondary cancer risk for women with rectal cancer treated with three-dimensional conformal radiation therapy (3DCRT) to the organs at risk (OARs) and some sensitive organs using different types of radiation-induced cancer risk prediction models, including Biological Effects of Ionizing Radiation (BEIRVII), Environmental Protection Agency (EPA) and International Commission on Radiological Protection (ICRP), and compare the results of the different models for same organs. Materials and methods: Thirty female patients with rectal cancer were considered and dose calculations were based on the PCRT-3D treatment planning system, while the radiotherapy of the patients had been performed using Shinva linear accelerator with a total dose of 45 Gy at 25 fractions. Planning target volume (PTV), OARs, and some sensitive organs were contoured, three models were used to evaluate secondary cancer risk (SCR) using the excess relative risk (ERR) and excess absolute risk (EAR). Results: The bladder presents the highest risk, in terms of ERR, and the femur head and uterus in terms of EAR from the three models (BEIR VII, EPA, and ICRP). Conclusion: Based on the obtained results, radiotherapy of rectal cancer is relatively higher for the bladder and femur head, compared to the risk for other organs, the kidney risk is significantly lower. It was observed that the SCR from the ICRP model was higher compared to BEIR VII and EPA models. Background: Radiotherapy has a significant side effect known as radiation-induced secondary cancer. This study aims to evaluate the dose and secondary cancer risk for women with rectal cancer treated with three-dimensional conformal radiation therapy (3DCRT) to the organs at risk (OARs) and some sensitive organs using different types of radiation-induced cancer risk prediction models, including Biological Effects of Ionizing Radiation (BEIRVII), Environmental Protection Agency (EPA) and International Commission on Radiological Protection (ICRP), and compare the results of the different models for same organs. Materials and methods: Thirty female patients with rectal cancer were considered and dose calculations were based on the PCRT-3D treatment planning system, while the radiotherapy of the patients had been performed using Shinva linear accelerator with a total dose of 45 Gy at 25 fractions. Planning target volume (PTV), OARs, and some sensitive organs were contoured, three models were used to evaluate secondary cancer risk (SCR) using the excess relative risk (ERR) and excess absolute risk (EAR). Results: The bladder presents the highest risk, in terms of ERR, and the femur head and uterus in terms of EAR from the three models (BEIR VII, EPA, and ICRP). Conclusion: Based on the obtained results, radiotherapy of rectal cancer is relatively higher for the bladder and femur head, compared to the risk for other organs, the kidney risk is significantly lower. It was observed that the SCR from the ICRP model was higher compared to BEIR VII and EPA models.


  • Public ingestion exposure to 226Ra in Ramsar, Iran

    by Nasrin Fathabadi, Ali Akbar Salehi, Kazem Naddafi, Mohammad Reza Kardan, Masud Yunesian, Ramin Nabizadeh Nodehi, Mohammad Reza Deevband, Molood Gooniband Shooshtari


  • Establishment of diagnostic reference levels for common multi-detector computed tomography examinations in Iran

    by Mohsen Najafi, Mohammad Reza Deevband, Mohsen Ahmadi, Mohammad Reza Kardan

    In order to establish diagnostic reference levels (DRLs) for multi-detector computed tomography (MDCT), four routine CT examinations were identified and a computer program was developed to collect data from 19 MDCT scanners in Iran. Mean values of Volume computed tomography dose index (CTDIvol) and dose-length product (DLP) in each site were calculated and the DRLs were defined as the 75th percentile of the distribution of the CTDIvol/DLP values for each examination. In terms of DLP, the DRLs of adult age group are 700, 290, 330, and 550 mGy cm for the Brain, Sinus, Chest, and Abdomen and Pelvis protocols, respectively. Although DRLs of this study are comparable to other international DRLs and in most cases are less than the international reference values, the great extent of dose distributions indicates that the CT imaging procedures in Iran should be optimized by applying diagnostic reference levels in order to decrease the radiation dose to patient undergoing CT examination.