Mohammad Reza Kardan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mohammad Reza Kardan has a total of 140 co-authors. Here are the top co-authors by number of shared publications:
M. Taheri
5 shared publications- S. Mehdi Hosseini Pooya
Nuclear Science and Technology Research Institute, Tehran, Iran
5 shared publications S. Setayeshi
Faculty of Nuclear Engineering and Physics, Amirkabir University of Tech., P.O. Box 15875-4413, Tehran, Iran
4 shared publicationsAli Mostofizadeh
Harbin Institute of Technology
3 shared publicationsFarideh Zakeri
Nuclear Science & Technology Research Institute, End of North Kargar, Tehran, Iran
3 shared publicationsH. Afarideh
Amirkabir University of Technology
3 shared publications
Latest Publications
- 1 October 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16  (10) , P10011
Patient-specific dose assessment using CBCT images and Monte Carlo calculations
- 1 October 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16  (10) , P10011
Patient-specific dose assessment using CBCT images and Monte Carlo calculations
- 1 November 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 944
Unfolding of fast neutron spectra by superheated drop detectors using Adaptive Network-Based Fuzzy Inference System (ANFIS)
- 1 November 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 944
Unfolding of fast neutron spectra by superheated drop detectors using Adaptive Network-Based Fuzzy Inference System (ANFIS)
- 21 May 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 939, 55-60
Development and validation of a Geant4 application to calculate the Response Matrix of a set of Superheated Drop Detectors under various external pressures
- 21 May 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 939, 55-60
Development and validation of a Geant4 application to calculate the Response Matrix of a set of Superheated Drop Detectors under various external pressures
- 1 March 2019
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 198, 11-17
Public ingestion exposure to 226Ra in Ramsar, Iran
- 1 March 2019
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 198, 11-17
Public ingestion exposure to 226Ra in Ramsar, Iran
- 1 December 2018
- Vol. 15  (Special -1) , 223
Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners
- 1 December 2018
- Vol. 15  (Special -1) , 223
Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners
- 29 November 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 184  (2) , 189-197
ASSESSMENT OF TERRESTRIAL RADIATION BY DIRECT MEASUREMENT OF AMBIENT DOSE EQUIVALENT RATE OF BACKGROUND RADIATION
Estimation of terrestrial external radiation is essential for assessment of public exposure to natural radiation. During national survey of natural radionuclide in soil in Iran, 979 soil samples were collected from different locations, in the same time ambient dose equivalent rate was measured by a scintillator detector. In this work, terrestrial radiation was estimated by direct measurement of ambient dose equivalent rate of background radiation. The response of dose measuring instrument to cosmic radiation at ground level was measured and other components were discussed and estimated. For verification, terrestrial radiation derived from this method was compared with those calculated from activity concentration of natural radionuclides in soil. The averages of ambient dose equivalent rate derived from activity concentration of by natural radionuclide in soil and from direct measurement are 55.07 and 62.57 nSv/h, respectively. The source of statistical and systematic uncertainties are introduced and discussed.
- 29 November 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 184  (2) , 189-197
ASSESSMENT OF TERRESTRIAL RADIATION BY DIRECT MEASUREMENT OF AMBIENT DOSE EQUIVALENT RATE OF BACKGROUND RADIATION
Estimation of terrestrial external radiation is essential for assessment of public exposure to natural radiation. During national survey of natural radionuclide in soil in Iran, 979 soil samples were collected from different locations, in the same time ambient dose equivalent rate was measured by a scintillator detector. In this work, terrestrial radiation was estimated by direct measurement of ambient dose equivalent rate of background radiation. The response of dose measuring instrument to cosmic radiation at ground level was measured and other components were discussed and estimated. For verification, terrestrial radiation derived from this method was compared with those calculated from activity concentration of natural radionuclides in soil. The averages of ambient dose equivalent rate derived from activity concentration of by natural radionuclide in soil and from direct measurement are 55.07 and 62.57 nSv/h, respectively. The source of statistical and systematic uncertainties are introduced and discussed.
- 15 February 2018
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 38  (1) , 422-433
Prediction of dose to the relatives of patients treated with radioiodine-131 using neural networks
In this study, the effective dose received by the family members and caregivers of 52 thyroid cancer patients, who had been treated with radioiodine I-131, was measured to investigate the ability of the neural network to predict the doses to the relatives. The effectiveness of this method to predict the relatives who will receive doses of more than 1 mSv was evaluated. The effective doses were measured by TLD. The inputs of the neural network include 13 different parameters that can potentially affect the dose, and the output was the dose to the family members. The neural networks in this study were feed-forward with a sigmoid activation function and one hidden layer. The mean and median of the measured doses were 0.45 and 0.28 mSv and its range was 0.1–3.64 mSv. The mean square error of the predicted doses by the neural network and the measured doses by TLD (mean squared error) for 99 individuals was 0.142. The optimum neural network was able to predict all the relatives who received doses of more than 1 mSv. The area under the receiver operating characteristic curve for the trained neural network was 0.957, showing its ability to distinguish these groups. Predicting the dose to a patient’s relatives before release is a helpful strategy for future optimisation. Using neural networks is a promising method for predicting the dose to the family members and defining high-risk patients and relatives. Patient-specific criteria for release and patient-specific advice and consultation can be used to reduce the dose to each family member.
- 15 February 2018
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 38  (1) , 422-433
Prediction of dose to the relatives of patients treated with radioiodine-131 using neural networks
In this study, the effective dose received by the family members and caregivers of 52 thyroid cancer patients, who had been treated with radioiodine I-131, was measured to investigate the ability of the neural network to predict the doses to the relatives. The effectiveness of this method to predict the relatives who will receive doses of more than 1 mSv was evaluated. The effective doses were measured by TLD. The inputs of the neural network include 13 different parameters that can potentially affect the dose, and the output was the dose to the family members. The neural networks in this study were feed-forward with a sigmoid activation function and one hidden layer. The mean and median of the measured doses were 0.45 and 0.28 mSv and its range was 0.1–3.64 mSv. The mean square error of the predicted doses by the neural network and the measured doses by TLD (mean squared error) for 99 individuals was 0.142. The optimum neural network was able to predict all the relatives who received doses of more than 1 mSv. The area under the receiver operating characteristic curve for the trained neural network was 0.957, showing its ability to distinguish these groups. Predicting the dose to a patient’s relatives before release is a helpful strategy for future optimisation. Using neural networks is a promising method for predicting the dose to the family members and defining high-risk patients and relatives. Patient-specific criteria for release and patient-specific advice and consultation can be used to reduce the dose to each family member.
- Open Access
- 1 January 2018
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 33  (2) , 167-173
Retrospective radon measurements based on implanted 210Po in glass objects using polycarbonate detectors
In the present investigation, a surface-deposited polonium was measured in 37 houses in Rasht and Ramsar cities of Iran with the aim of evaluating the retrospective radon concentration. The CR-LR technique is widely used in this regard, but for the first time, Lexan polycarbonate detectors were used to measure the activity of 210Po planted in glassy objects. These detectors were placed on glassy surfaces for 153 to 365 days. A passive cylindrical diffusion chamber was used for the contemporary radon concentration measurements. The diffusion chamber consists of the Lexan polycarbonate films as a solid state nuclear track detectors and filter. The surface-deposited 210Po activity concentration was found to vary from 0.26 to 11.96 mBqcm-2 with average of 2.62 mBqcm-2. The sensitivity of 210Po to polycarbonate was determined to be 0.06456 track per cm2 per mBqhcm-2. Thus, the radon concentration was found to vary from 122 to 4840 Bqm-3 with an average value 1243 Bqm-3 and the contemporary radon concentration in the area was found to vary from 15 to 2420 Bqm-3 with an average 513 Bqm-3. The results indicate that there is a significant correlation between the concentration of the retrospective radon and the concentration of the contemporary radon gas in the indicated areas with a coefficient of 0.80672.
- 1 January 2018
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 33  (2) , 167-173
Open AccessRetrospective radon measurements based on implanted 210Po in glass objects using polycarbonate detectors
In the present investigation, a surface-deposited polonium was measured in 37 houses in Rasht and Ramsar cities of Iran with the aim of evaluating the retrospective radon concentration. The CR-LR technique is widely used in this regard, but for the first time, Lexan polycarbonate detectors were used to measure the activity of 210Po planted in glassy objects. These detectors were placed on glassy surfaces for 153 to 365 days. A passive cylindrical diffusion chamber was used for the contemporary radon concentration measurements. The diffusion chamber consists of the Lexan polycarbonate films as a solid state nuclear track detectors and filter. The surface-deposited 210Po activity concentration was found to vary from 0.26 to 11.96 mBqcm-2 with average of 2.62 mBqcm-2. The sensitivity of 210Po to polycarbonate was determined to be 0.06456 track per cm2 per mBqhcm-2. Thus, the radon concentration was found to vary from 122 to 4840 Bqm-3 with an average value 1243 Bqm-3 and the contemporary radon concentration in the area was found to vary from 15 to 2420 Bqm-3 with an average 513 Bqm-3. The results indicate that there is a significant correlation between the concentration of the retrospective radon and the concentration of the contemporary radon gas in the indicated areas with a coefficient of 0.80672.
- 9 December 2017
- Published by Walter de Gruyter GmbH in Kerntechnik
- Vol. 82  (6) , 648-652
Developing light nano-composites with improved mechanical properties for neutron shielding
Although radiation exposures in manned space missions are normally below the limits recommended to NASA by NCRP, in long-duration deep space exploratory missions astronauts may receive relatively high doses of ionizing radiation. Novel light polyethylene-based composites can be considered as effective radiation shields in space explorations. However, normally these composites cannot provide desired mechanical properties. Over the past several years our laboratories have focused on developing efficient methods for both physical and biological protection of the crew in long term space missions. In this study carbon nanotubes and either nano-sized or micro-sized boron carbide (B4C) fillers were incorporated into the continuous phase of low density polyethylene (LDPE). In the next phase, the mechanical characteristics of the composites as well as their neutron attenuation properties were studied. Findings of this study indicated enhanced mechanical properties accompanied by an enhanced shielding efficiency for neutrons at some specific weight fraction of the fillers.
- 9 December 2017
- Published by Walter de Gruyter GmbH in Kerntechnik
- Vol. 82  (6) , 648-652
Developing light nano-composites with improved mechanical properties for neutron shielding
Although radiation exposures in manned space missions are normally below the limits recommended to NASA by NCRP, in long-duration deep space exploratory missions astronauts may receive relatively high doses of ionizing radiation. Novel light polyethylene-based composites can be considered as effective radiation shields in space explorations. However, normally these composites cannot provide desired mechanical properties. Over the past several years our laboratories have focused on developing efficient methods for both physical and biological protection of the crew in long term space missions. In this study carbon nanotubes and either nano-sized or micro-sized boron carbide (B4C) fillers were incorporated into the continuous phase of low density polyethylene (LDPE). In the next phase, the mechanical characteristics of the composites as well as their neutron attenuation properties were studied. Findings of this study indicated enhanced mechanical properties accompanied by an enhanced shielding efficiency for neutrons at some specific weight fraction of the fillers.
- 1 November 2017
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 178-179, 168-176
A national survey of natural radionuclides in soils and terrestrial radiation exposure in Iran
- 1 November 2017
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 178-179, 168-176
A national survey of natural radionuclides in soils and terrestrial radiation exposure in Iran