Takaaki Ohmori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Takaaki Ohmori has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Hiroyuki Tsuchiya
Kanazawa University
10 shared publications - Tamon Kabata
Department of Orthopedic Surgery, Graduate School of Medical Science, Kanazawa University, Kanazawa, Japan
9 shared publications - Daisuke Inoue
Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
7 shared publications - Yoshitomo Kajino
Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
5 shared publications - Tomoharu Takagi
Department of Orthopedic Surgery, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
4 shared publications - Junya Yoshitani
Young Adult Hip Service, Department of Trauma and Orthopaedics Addenbrooke's ‐ Cambridge University Hospitals NHS Foundation Trust Cambridge UK
3 shared publications
Latest Publications
- Open Access
- 10 May 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (5) , 574
Chondroprotective Effects of Chondrogenic Differentiated Adipose-Derived Mesenchymal Stem Cells Sheet on Degenerated Articular Cartilage in an Experimental Rabbit Model
Adipose-derived stem cells (ADSCs) have been studied for many years as a therapeutic option for osteoarthritis (OA); however, their efficacy remains insufficient. Since platelet-rich plasma (PRP) induces chondrogenic differentiation in ADSCs and the formation of a sheet structure by ascorbic acid can increase the number of viable cells, we hypothesized that the injection of chondrogenic cell sheets combined with the effects of PRP and ascorbic acid may hinder the progression of OA. The effects of induction of differentiation by PRP and formation of sheet structure by ascorbic acid on changes in chondrocyte markers (collagen II, aggrecan, Sox9) in ADSCs were evaluated. Changes in mucopolysaccharide and VEGF-A secretion from cells injected intra-articularly in a rabbit OA model were also evaluated. ADSCs treated by PRP strongly chondrocyte markers, including type II collagen, Sox9, and aggrecan, and their gene expression was maintained even after sheet-like structure formation induced by ascorbic acid. In this rabbit OA model study, the inhibition of OA progression by intra-articular injection was improved by inducing chondrocyte differentiation with PRP and sheet structure formation with ascorbic acid in ADSCs.
- 10 May 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (5) , 574
Open AccessChondroprotective Effects of Chondrogenic Differentiated Adipose-Derived Mesenchymal Stem Cells Sheet on Degenerated Articular Cartilage in an Experimental Rabbit Model
Adipose-derived stem cells (ADSCs) have been studied for many years as a therapeutic option for osteoarthritis (OA); however, their efficacy remains insufficient. Since platelet-rich plasma (PRP) induces chondrogenic differentiation in ADSCs and the formation of a sheet structure by ascorbic acid can increase the number of viable cells, we hypothesized that the injection of chondrogenic cell sheets combined with the effects of PRP and ascorbic acid may hinder the progression of OA. The effects of induction of differentiation by PRP and formation of sheet structure by ascorbic acid on changes in chondrocyte markers (collagen II, aggrecan, Sox9) in ADSCs were evaluated. Changes in mucopolysaccharide and VEGF-A secretion from cells injected intra-articularly in a rabbit OA model were also evaluated. ADSCs treated by PRP strongly chondrocyte markers, including type II collagen, Sox9, and aggrecan, and their gene expression was maintained even after sheet-like structure formation induced by ascorbic acid. In this rabbit OA model study, the inhibition of OA progression by intra-articular injection was improved by inducing chondrocyte differentiation with PRP and sheet structure formation with ascorbic acid in ADSCs.
- Open Access
- 22 February 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-7
Primary total knee arthroplasty assisted by computed tomography-free navigation for secondary knee osteoarthritis following massive calcium phosphate cement packing for distal femoral giant-cell bone tumor treatment: a case report
Background: Giant cell tumor of bone (GCTB) is an intermediate tumor commonly arising from the epiphysis of the distal femur and proximal tibia. Standard GCTB treatment is joint-preserving surgery performed using thorough curettage and the filling of the cavity with allo-, auto-, polymethyl methacrylate (PMMA), or synthetic bone graft. Calcium phosphate cement (CPC) is an artificial bone substitute, which has the benefit of being able to adjust defects, consequently inducing immediate mechanical strength, and promoting biological healing. Secondary osteoarthritis may occur following GCTB treatment and may need additional surgery if severe. However, details regarding surgery for secondary osteoarthritis have not been fully elucidated. There are no reports on the use of total knee arthroplasty (TKA) for the treatment of secondary osteoarthritis following CPC packing. The insertion of an alignment rod is a standard procedure in TKA; however, it was difficult to perform in this case due to CPC. Therefore, we used a computed tomography (CT)-free navigation system to assist the distal femur cut. This study presents a knee joint secondary osteoarthritis case following CPC packing for GCTB curettage that was treated with standard TKA. Case presentation: A 67-year-old Japanese woman, who was previously diagnosed with left distal femur GCTB and was treated by curettage and CPC packing 7 years ago, complained of severe knee pain. Left knee joint plain radiography revealed Kellgren and Lawrence (K-L) grade 4 osteoarthritis without evidence of tumor recurrence. Therefore, she was scheduled for TKA. There are no reports on the cutting of a femoral condyle surface with massive CPC with accurate alignment. Because it is difficult to insert the alignment rod intramedullary and cut the femoral condyle with CPC, we planned CT-free navigation-guided surgery for accurate bone cutting using an oscillating tip saw system to prevent CPC cracks. We performed standard TKA without complications, as planned. Postoperative X-ray showed normal alignment. Knee Society Knee Score (KSKS) and Knee Society Function Score (KSFS) ameliorated from 27 and 29 to 64 and 68, respectively The patient can walk without a cane postoperatively. Conclusion: There was no report about the surface TKA guided by CT-free navigation after primary GCT surgery with CPC. We believe that this case report will help in planning salvage surgery for secondary osteoarthritis after CPC packing.
- 22 February 2022
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 23 (1) , 1-7
Open AccessPrimary total knee arthroplasty assisted by computed tomography-free navigation for secondary knee osteoarthritis following massive calcium phosphate cement packing for distal femoral giant-cell bone tumor treatment: a case report
Background: Giant cell tumor of bone (GCTB) is an intermediate tumor commonly arising from the epiphysis of the distal femur and proximal tibia. Standard GCTB treatment is joint-preserving surgery performed using thorough curettage and the filling of the cavity with allo-, auto-, polymethyl methacrylate (PMMA), or synthetic bone graft. Calcium phosphate cement (CPC) is an artificial bone substitute, which has the benefit of being able to adjust defects, consequently inducing immediate mechanical strength, and promoting biological healing. Secondary osteoarthritis may occur following GCTB treatment and may need additional surgery if severe. However, details regarding surgery for secondary osteoarthritis have not been fully elucidated. There are no reports on the use of total knee arthroplasty (TKA) for the treatment of secondary osteoarthritis following CPC packing. The insertion of an alignment rod is a standard procedure in TKA; however, it was difficult to perform in this case due to CPC. Therefore, we used a computed tomography (CT)-free navigation system to assist the distal femur cut. This study presents a knee joint secondary osteoarthritis case following CPC packing for GCTB curettage that was treated with standard TKA. Case presentation: A 67-year-old Japanese woman, who was previously diagnosed with left distal femur GCTB and was treated by curettage and CPC packing 7 years ago, complained of severe knee pain. Left knee joint plain radiography revealed Kellgren and Lawrence (K-L) grade 4 osteoarthritis without evidence of tumor recurrence. Therefore, she was scheduled for TKA. There are no reports on the cutting of a femoral condyle surface with massive CPC with accurate alignment. Because it is difficult to insert the alignment rod intramedullary and cut the femoral condyle with CPC, we planned CT-free navigation-guided surgery for accurate bone cutting using an oscillating tip saw system to prevent CPC cracks. We performed standard TKA without complications, as planned. Postoperative X-ray showed normal alignment. Knee Society Knee Score (KSKS) and Knee Society Function Score (KSFS) ameliorated from 27 and 29 to 64 and 68, respectively The patient can walk without a cane postoperatively. Conclusion: There was no report about the surface TKA guided by CT-free navigation after primary GCT surgery with CPC. We believe that this case report will help in planning salvage surgery for secondary osteoarthritis after CPC packing.
- Open Access
- 11 April 2021
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 479 (7) , 1613-1623
Antibacterial Activity in Iodine-coated Implants Under Conditions of Iodine Loss: Study in a Rat Model Plus In Vitro Analysis
Background: We developed iodine-coated titanium implants to suppress microbial activity and prevent periprosthetic joint infection (PJI); their efficacy was demonstrated in animal and in vitro models. The iodine content in iodine-coated implants naturally decreases in vivo. However, to our knowledge, the effect of reduced iodine content on the implant’s antimicrobial activity has not been evaluated to date. Questions/purposes: (1) How much does the iodine content on the implant surface decrease after 4 and 8 weeks in vivo in a rat model? (2) What effect does the reduced iodine content have on the antimicrobial effect of the implant against multiple bacteria in an in vitro model? Methods: This experiment was performed in two parts: an in vivo experiment to determine attenuation of iodine levels over time in rats, and an in vitro experiment in which we sought to assess whether the reduced iodine content observed in the in vivo experiment was still sufficient to deliver antimicrobial activity against common pathogens seen in PJI. For the in vivo experiment, three types of titanium alloy washers were implanted in rats: untreated (Ti), surface-anodized to produce an oxide film (Ti-O), and with an iodine layer on the oxidation film (Ti-I). The attenuation of iodine levels in rats was measured over time using inductively coupled plasma-mass spectrometry. Herein, only the Ti-I washer was used, with five implanted in each rat that were removed after 4 or 8 weeks. For the 4- and 8-week models, two rats and 15 washers were used. For the in vitro study, to determine the antibacterial effect, three types of washers (Ti, Ti-O, and Ti-I) (nine washers in total) were implanted in each rat. Then, the washers were removed and the antibacterial effect of each washer was examined on multiple bacterial species using the spread plate method and fluorescence microscopy. For the spread plate method, six rats were used, and five rats were used for the observation using fluorescence microscopy; further, 4- and 8-week models were made for each method. Thus, a total of 22 rats and 198 washers were used. Live and dead bacteria in the biofilm were stained, and the biofilm coverage percentage for quantitative analysis was determined using fluorescence microscopy in a nonblinded manner. Ti-I was used as the experimental group, and Ti and Ti-O were used as control groups. The total number of rats and washers used throughout this study was 24 and 213, respectively. Results: Iodine content in rats implanted with Ti-I samples decreased to 72% and 65% after the in vivo period of 4 and 8 weeks, respectively (p = 0.001 and p < 0.001, respectively). In the in vitro experiment, the Ti-I implants demonstrated a stronger antimicrobial activity than Ti and Ti-O implants in the 4- and 8-week models. Both the median number of bacterial colonies and the median biofilm coverage percentage with live bacteria on Ti-I were lower than those on Ti or Ti-O implants for each bacterial species in the 4- and 8-week models. There was no difference in the median biofilm coverage percentage of dead bacteria. In the 8-week model, the antibacterial activity using the spread plate method had median (interquartile range) numbers of bacteria on the Ti, Ti-O, and Ti-I implants of 112 (104 to 165) × 105, 147 (111 to 162) × 105, and 55 (37 to 67) × 105 of methicillin-sensitive Staphylococcus aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.009); 71 (39 to 111) × 105, 50 (44 to 62) × 105, and 26 (9 to 31)× 105 CFU of methicillin-resistant S. aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.034); and 77 (74 to 83) × 106, 111 (95 to 117) × 106, and 30 (21 to 45) × 106 CFU of Pseudomonas aeruginosa (Ti-I versus Ti, p = 0.004; Ti-I versus Ti-O, p = 0.009). Despite the decrease in the iodine content of Ti-I after 8 weeks, it demonstrated better antibacterial activity against all tested bacteria than the Ti and Ti-O implants. Conclusion: Iodine-coated implants retained their iodine content and antibacterial activity against methicillin-sensitive S. aureus, methicillin-resistant S. aureus, and P. aeruginosa for 8 weeks in vivo in rats. To evaluate the longer-lasting antibacterial efficacy, further research using larger infected animal PJI models with implants in the joints of both males and females is desirable. Clinical Relevance: Iodine-coated titanium implants displayed an antibacterial activity for 8 weeks in rats in vivo. Although the findings in a rat model do not guarantee efficacy in humans, they represent an important step toward clinical application.
- 11 April 2021
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 479 (7) , 1613-1623
Open AccessAntibacterial Activity in Iodine-coated Implants Under Conditions of Iodine Loss: Study in a Rat Model Plus In Vitro Analysis
Background: We developed iodine-coated titanium implants to suppress microbial activity and prevent periprosthetic joint infection (PJI); their efficacy was demonstrated in animal and in vitro models. The iodine content in iodine-coated implants naturally decreases in vivo. However, to our knowledge, the effect of reduced iodine content on the implant’s antimicrobial activity has not been evaluated to date. Questions/purposes: (1) How much does the iodine content on the implant surface decrease after 4 and 8 weeks in vivo in a rat model? (2) What effect does the reduced iodine content have on the antimicrobial effect of the implant against multiple bacteria in an in vitro model? Methods: This experiment was performed in two parts: an in vivo experiment to determine attenuation of iodine levels over time in rats, and an in vitro experiment in which we sought to assess whether the reduced iodine content observed in the in vivo experiment was still sufficient to deliver antimicrobial activity against common pathogens seen in PJI. For the in vivo experiment, three types of titanium alloy washers were implanted in rats: untreated (Ti), surface-anodized to produce an oxide film (Ti-O), and with an iodine layer on the oxidation film (Ti-I). The attenuation of iodine levels in rats was measured over time using inductively coupled plasma-mass spectrometry. Herein, only the Ti-I washer was used, with five implanted in each rat that were removed after 4 or 8 weeks. For the 4- and 8-week models, two rats and 15 washers were used. For the in vitro study, to determine the antibacterial effect, three types of washers (Ti, Ti-O, and Ti-I) (nine washers in total) were implanted in each rat. Then, the washers were removed and the antibacterial effect of each washer was examined on multiple bacterial species using the spread plate method and fluorescence microscopy. For the spread plate method, six rats were used, and five rats were used for the observation using fluorescence microscopy; further, 4- and 8-week models were made for each method. Thus, a total of 22 rats and 198 washers were used. Live and dead bacteria in the biofilm were stained, and the biofilm coverage percentage for quantitative analysis was determined using fluorescence microscopy in a nonblinded manner. Ti-I was used as the experimental group, and Ti and Ti-O were used as control groups. The total number of rats and washers used throughout this study was 24 and 213, respectively. Results: Iodine content in rats implanted with Ti-I samples decreased to 72% and 65% after the in vivo period of 4 and 8 weeks, respectively (p = 0.001 and p < 0.001, respectively). In the in vitro experiment, the Ti-I implants demonstrated a stronger antimicrobial activity than Ti and Ti-O implants in the 4- and 8-week models. Both the median number of bacterial colonies and the median biofilm coverage percentage with live bacteria on Ti-I were lower than those on Ti or Ti-O implants for each bacterial species in the 4- and 8-week models. There was no difference in the median biofilm coverage percentage of dead bacteria. In the 8-week model, the antibacterial activity using the spread plate method had median (interquartile range) numbers of bacteria on the Ti, Ti-O, and Ti-I implants of 112 (104 to 165) × 105, 147 (111 to 162) × 105, and 55 (37 to 67) × 105 of methicillin-sensitive Staphylococcus aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.009); 71 (39 to 111) × 105, 50 (44 to 62) × 105, and 26 (9 to 31)× 105 CFU of methicillin-resistant S. aureus (Ti-I versus Ti, p = 0.026; Ti-I versus Ti-O, p = 0.034); and 77 (74 to 83) × 106, 111 (95 to 117) × 106, and 30 (21 to 45) × 106 CFU of Pseudomonas aeruginosa (Ti-I versus Ti, p = 0.004; Ti-I versus Ti-O, p = 0.009). Despite the decrease in the iodine content of Ti-I after 8 weeks, it demonstrated better antibacterial activity against all tested bacteria than the Ti and Ti-O implants. Conclusion: Iodine-coated implants retained their iodine content and antibacterial activity against methicillin-sensitive S. aureus, methicillin-resistant S. aureus, and P. aeruginosa for 8 weeks in vivo in rats. To evaluate the longer-lasting antibacterial efficacy, further research using larger infected animal PJI models with implants in the joints of both males and females is desirable. Clinical Relevance: Iodine-coated titanium implants displayed an antibacterial activity for 8 weeks in rats in vivo. Although the findings in a rat model do not guarantee efficacy in humans, they represent an important step toward clinical application.
- 29 March 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (12) , 1093-1103
Contralateral Lower-Limb Functional Status Before Total Hip Arthroplasty
Background: Postoperative gait speed, especially comfortable gait speed, is an important factor for predicting function after total hip arthroplasty (THA). In this study, we examined factors related to gait speed, including preoperative lower and upper-limb functional parameters and postoperative lower-limb alignment. In addition, we examined factors related to postoperative good comfortable gait speed (≥1.34 m/s: one indicator of a good clinical outcome). The purpose of this study was to determine if better preoperative functional parameters had a positive effect on postoperative gait speed. Methods: This prospective case-control study included 91 patients with hip osteoarthritis who underwent unilateral THA. Patients who had undergone a prior hip surgical procedure or had Crowe type-3 and 4 hips, complications after THA, knee osteoarthritis-related pain, and severe lumbar conditions were excluded. The 1-leg standing time (OLST) and knee extensor strength of the operatively treated side and the contralateral side and the functional reach test were examined preoperatively and at 1 year postoperatively. The leg-length discrepancy and global offset compared with the contralateral side and leg lengthening were examined using 3-dimensional models captured through computed tomographic scans. Results: The preoperative contralateral side OLST was a significant factor (p < 0.001) for postoperative comfortable gait speed, and the preoperative contralateral-side knee extensor strength was a significant factor (p = 0.018) for postoperative maximum gait speed. Leg-length discrepancy and differences in global offset after THA were not significant factors for postoperative gait speed. The preoperative comfortable gait speed with a cutoff value of 1.115 m/s (area under the receiver operating characteristic curve, 0.690 [95% confidence interval, 0.569 to 0.810]; p = 0.003; sensitivity of 65.5% and specificity of 74.2%) was an independent factor associated with a good postoperative comfortable gait speed. Preoperative contralateral-side OLST was a significant factor (p = 0.027) for preoperative comfortable gait speed. Conclusions: The preoperative contralateral-side, lower-limb functional status is a significant factor for postoperative gait speed. Early surgical intervention before the contralateral-side function declines or a preoperative rehabilitation intervention on the contralateral side may improve THA outcome. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
- 29 March 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (12) , 1093-1103
Contralateral Lower-Limb Functional Status Before Total Hip Arthroplasty
Background: Postoperative gait speed, especially comfortable gait speed, is an important factor for predicting function after total hip arthroplasty (THA). In this study, we examined factors related to gait speed, including preoperative lower and upper-limb functional parameters and postoperative lower-limb alignment. In addition, we examined factors related to postoperative good comfortable gait speed (≥1.34 m/s: one indicator of a good clinical outcome). The purpose of this study was to determine if better preoperative functional parameters had a positive effect on postoperative gait speed. Methods: This prospective case-control study included 91 patients with hip osteoarthritis who underwent unilateral THA. Patients who had undergone a prior hip surgical procedure or had Crowe type-3 and 4 hips, complications after THA, knee osteoarthritis-related pain, and severe lumbar conditions were excluded. The 1-leg standing time (OLST) and knee extensor strength of the operatively treated side and the contralateral side and the functional reach test were examined preoperatively and at 1 year postoperatively. The leg-length discrepancy and global offset compared with the contralateral side and leg lengthening were examined using 3-dimensional models captured through computed tomographic scans. Results: The preoperative contralateral side OLST was a significant factor (p < 0.001) for postoperative comfortable gait speed, and the preoperative contralateral-side knee extensor strength was a significant factor (p = 0.018) for postoperative maximum gait speed. Leg-length discrepancy and differences in global offset after THA were not significant factors for postoperative gait speed. The preoperative comfortable gait speed with a cutoff value of 1.115 m/s (area under the receiver operating characteristic curve, 0.690 [95% confidence interval, 0.569 to 0.810]; p = 0.003; sensitivity of 65.5% and specificity of 74.2%) was an independent factor associated with a good postoperative comfortable gait speed. Preoperative contralateral-side OLST was a significant factor (p = 0.027) for preoperative comfortable gait speed. Conclusions: The preoperative contralateral-side, lower-limb functional status is a significant factor for postoperative gait speed. Early surgical intervention before the contralateral-side function declines or a preoperative rehabilitation intervention on the contralateral side may improve THA outcome. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 19 October 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-11
Periodic injections of adipose-derived stem cell sheets attenuate osteoarthritis progression in an experimental rabbit model
Background: Subcutaneous adipose tissue represents an abundant source of multipotent adult stem cells named as Adipose-derived stem cells (ADSCs). With a cell sheet approach, ADSCs survive longer, and can be delivered in large quantities. We investigated whether intra-articular ADSC sheets attenuated osteoarthritis (OA) progression in a rabbit anterior cruciate ligament transection (ACLT) model. Methods: Fabricating medium containing ascorbate-2-phosphate was used to enhance collagen protein secretion by the ADSCs to make ADSC sheets. At 4 weeks after ACLT, autologous ADSC sheets were injected intra-articularly into the right knee (ADSC sheets group), and autologous cell death sheets treated by liquid nitrogen were injected into the left knee (control group). Subsequent injections were administered once weekly. Femoral condyles were compared macroscopically and histologically. Results: Macroscopically, OA progression was significantly milder in the ADSC sheets than in the control groups. Histologically, control knees showed obvious erosions in the medial and lateral condyles, while cartilage was retained predominantly in the ADSC sheets group. Immunohistochemically, MMP-1, MMP-13, ADAMTS-4 were less expressive in the ADSC sheets than in the control groups. Conclusions: Periodic ADSC sheets injections inhibited articular cartilage degeneration without inducing any adverse effects. A large quantity of autologous ADSCs delivered by cell sheets homed to the synovium and protected chondrocytes.
- 19 October 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-11
Open AccessPeriodic injections of adipose-derived stem cell sheets attenuate osteoarthritis progression in an experimental rabbit model
Background: Subcutaneous adipose tissue represents an abundant source of multipotent adult stem cells named as Adipose-derived stem cells (ADSCs). With a cell sheet approach, ADSCs survive longer, and can be delivered in large quantities. We investigated whether intra-articular ADSC sheets attenuated osteoarthritis (OA) progression in a rabbit anterior cruciate ligament transection (ACLT) model. Methods: Fabricating medium containing ascorbate-2-phosphate was used to enhance collagen protein secretion by the ADSCs to make ADSC sheets. At 4 weeks after ACLT, autologous ADSC sheets were injected intra-articularly into the right knee (ADSC sheets group), and autologous cell death sheets treated by liquid nitrogen were injected into the left knee (control group). Subsequent injections were administered once weekly. Femoral condyles were compared macroscopically and histologically. Results: Macroscopically, OA progression was significantly milder in the ADSC sheets than in the control groups. Histologically, control knees showed obvious erosions in the medial and lateral condyles, while cartilage was retained predominantly in the ADSC sheets group. Immunohistochemically, MMP-1, MMP-13, ADAMTS-4 were less expressive in the ADSC sheets than in the control groups. Conclusions: Periodic ADSC sheets injections inhibited articular cartilage degeneration without inducing any adverse effects. A large quantity of autologous ADSCs delivered by cell sheets homed to the synovium and protected chondrocytes.
- 8 June 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 35 (01) , 032-038
Importance of Three-Dimensional Evaluation of Surgical Transepicondylar Axis in Total Knee Arthroplasty
In total knee arthroplasty, the surgical transepicondylar axis (SEA) is one of the most reliable rotation axes for stabilizing of the patellofemoral joint. The SEA is identified with reference to the lateral epicondyle and the medial sulcus of the medial epicondyle. However, these two structures rarely appear on the same plane on computed tomography (CT), and it is necessary to take two points in separate images. Many surgeons measure the SEA on the same image (pseudo SEA) instead. We aimed to determine the difference between true SEAs and pseudo SEAs. A total of 31 normal knees and 24 varus knees were included in this study. Three-dimensional (3D) models of the femur were reconstructed from CT images, and a reconstructed plane was made using the International Society of Biomechanics coordinate system. Pseudo SEAs drawn in the plane passing through the lateral epicondyle and medial sulcus were defined as l-SEA and m-SEA, respectively. L-SEA, m-SEA, true SEA, and posterior condylar axis (PCA) were projected onto the International Society of Biomechanics coordinate plane and, “p l-SEA,” “p m-SEA,” “p true SEA,” and “p PCA” were obtained. The true SEA angle was defined as the angle between p true SEA and p PCA. The l-SEA angle or m-SEA angle was defined as the angle between the p l-SEA or p m-SEA and p PCA, respectively. There were no statistically significant differences between true SEA angle (2.64 ± 2.01 degrees) and pseudo SEA angle (l-SEA angle: 2.74 ± 2.07 degrees, m-SEA: 2.54 ± 2.19 degrees). Conversely, 12 knees in the normal group and 2 knees in the varus group had differences of more than 1 degree (p = 0.01). Among them, 6 knees in the normal group and 0 knees in the varus group had a difference of 2 degrees or more (p = 0.03). In most cases, pseudo SEA can be substituted for true SEA.
- 8 June 2020
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 35 (01) , 032-038
Importance of Three-Dimensional Evaluation of Surgical Transepicondylar Axis in Total Knee Arthroplasty
In total knee arthroplasty, the surgical transepicondylar axis (SEA) is one of the most reliable rotation axes for stabilizing of the patellofemoral joint. The SEA is identified with reference to the lateral epicondyle and the medial sulcus of the medial epicondyle. However, these two structures rarely appear on the same plane on computed tomography (CT), and it is necessary to take two points in separate images. Many surgeons measure the SEA on the same image (pseudo SEA) instead. We aimed to determine the difference between true SEAs and pseudo SEAs. A total of 31 normal knees and 24 varus knees were included in this study. Three-dimensional (3D) models of the femur were reconstructed from CT images, and a reconstructed plane was made using the International Society of Biomechanics coordinate system. Pseudo SEAs drawn in the plane passing through the lateral epicondyle and medial sulcus were defined as l-SEA and m-SEA, respectively. L-SEA, m-SEA, true SEA, and posterior condylar axis (PCA) were projected onto the International Society of Biomechanics coordinate plane and, “p l-SEA,” “p m-SEA,” “p true SEA,” and “p PCA” were obtained. The true SEA angle was defined as the angle between p true SEA and p PCA. The l-SEA angle or m-SEA angle was defined as the angle between the p l-SEA or p m-SEA and p PCA, respectively. There were no statistically significant differences between true SEA angle (2.64 ± 2.01 degrees) and pseudo SEA angle (l-SEA angle: 2.74 ± 2.07 degrees, m-SEA: 2.54 ± 2.19 degrees). Conversely, 12 knees in the normal group and 2 knees in the varus group had differences of more than 1 degree (p = 0.01). Among them, 6 knees in the normal group and 0 knees in the varus group had a difference of 2 degrees or more (p = 0.03). In most cases, pseudo SEA can be substituted for true SEA.
- Open Access
- 31 January 2018
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2018 (1) , 1743068
Clinical Results of Total Hip Arthroplasty in Two Patients with Charcot Hip Joints due to Congenital Insensivity to Pain with Anhydrosis
Traditionally, Charcot arthropathy has been considered an absolute contraindication for total hip arthroplasty (THA). However, some recent reports have shown that good short‐ to mid‐term results can be achieved by improving the durability of the implant. This paper reports the mid‐ to long‐term results of THA in two patients with Charcot hip joints caused by congenital insensivity to pain with anhydrosis. Both patients suffered multiple posterior dislocations in the six months immediately following surgery. However, with the continuous use of a hard abduction brace, one patient was eventually able to walk with a lofstrand cane and the other with the use of one crutch. Although one patient experienced a dislocation five years after surgery, X‐rays taken after nine years and five years, respectively, revealed no clinical signs of implant loosening. We conclude that, with careful planning and appropriate precautions, THA may be a viable treatment option for Charcot hip joints caused by congenital insensivity to pain with anhydrosis.
- 31 January 2018
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2018 (1) , 1743068
Open AccessClinical Results of Total Hip Arthroplasty in Two Patients with Charcot Hip Joints due to Congenital Insensivity to Pain with Anhydrosis
Traditionally, Charcot arthropathy has been considered an absolute contraindication for total hip arthroplasty (THA). However, some recent reports have shown that good short‐ to mid‐term results can be achieved by improving the durability of the implant. This paper reports the mid‐ to long‐term results of THA in two patients with Charcot hip joints caused by congenital insensivity to pain with anhydrosis. Both patients suffered multiple posterior dislocations in the six months immediately following surgery. However, with the continuous use of a hard abduction brace, one patient was eventually able to walk with a lofstrand cane and the other with the use of one crutch. Although one patient experienced a dislocation five years after surgery, X‐rays taken after nine years and five years, respectively, revealed no clinical signs of implant loosening. We conclude that, with careful planning and appropriate precautions, THA may be a viable treatment option for Charcot hip joints caused by congenital insensivity to pain with anhydrosis.
- 21 March 2017
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 27 (8) , 1131-1138
The influence of surgical approach on postoperative pelvic tilt after total hip arthroplasty
Background Past reports have shown the tendency of posterior pelvic tilt to increase over time after total hip arthroplasty (THA). We have hypothesized that the volume and extent of released joint capsule may influence the change in postoperative pelvic tilt. This study was conducted to ascertain whether surgical approach during THA (posterior or anterior) has an effect on postoperative changes in pelvic tilt. Methods We conducted a retrospective review of 81 hips in 60 patients. Patients classified as Crowe group 2, 3, and 4, those who had multiple previous compression fractures, and those with spinal fusion due to spinal arthrosis were excluded. Also, those who had previously undergone THA or total hip resurfacing also were excluded. Patients were divided into two groups, those with preoperative anterior pelvic tilt and those with posterior tilt. Preoperative and postoperative X-rays and CT scans for each group were assessed to determine the chronological change in pelvic tilt, and the data were statistically analyzed for patients who had experienced both the posterior and anterior approaches. Results Regardless of surgical approach, there was no significant difference in the mean change in postoperative APP angle over time in either the bilateral or unilateral cases or in the groups of preoperative anterior or posterior pelvic tilt. Conclusions Our results showed that surgical approach does not influence postoperative pelvic tilt after THA. In preoperative planning for THA, therefore, surgeons may need not to consider the difference of surgical approach with regard to postoperative changes in pelvic tilt.
- 21 March 2017
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 27 (8) , 1131-1138
The influence of surgical approach on postoperative pelvic tilt after total hip arthroplasty
Background Past reports have shown the tendency of posterior pelvic tilt to increase over time after total hip arthroplasty (THA). We have hypothesized that the volume and extent of released joint capsule may influence the change in postoperative pelvic tilt. This study was conducted to ascertain whether surgical approach during THA (posterior or anterior) has an effect on postoperative changes in pelvic tilt. Methods We conducted a retrospective review of 81 hips in 60 patients. Patients classified as Crowe group 2, 3, and 4, those who had multiple previous compression fractures, and those with spinal fusion due to spinal arthrosis were excluded. Also, those who had previously undergone THA or total hip resurfacing also were excluded. Patients were divided into two groups, those with preoperative anterior pelvic tilt and those with posterior tilt. Preoperative and postoperative X-rays and CT scans for each group were assessed to determine the chronological change in pelvic tilt, and the data were statistically analyzed for patients who had experienced both the posterior and anterior approaches. Results Regardless of surgical approach, there was no significant difference in the mean change in postoperative APP angle over time in either the bilateral or unilateral cases or in the groups of preoperative anterior or posterior pelvic tilt. Conclusions Our results showed that surgical approach does not influence postoperative pelvic tilt after THA. In preoperative planning for THA, therefore, surgeons may need not to consider the difference of surgical approach with regard to postoperative changes in pelvic tilt.
- 5 November 2015
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 25 (8) , 1293-1300
Usefullness of three-dimensional templating software to quantify the contact state between implant and femur in total hip arthroplasty
It would be ideal if surgeons could precisely confirm whether the planned femoral component achieves the best fit and fill of implant and femur. However, the cortico-cancellous interfaces can be difficult to standardize using plain radiography, and therefore, determining the contact state is a subjective decision by the examiner. Few reports have described the use of CT-based three-dimensional templating software to quantify the contact state of stem and femur in detail. The purpose of this study was to use three-dimensional templating software to quantify the implant–femur contact state and develop a technique to analyze the initial fixation pattern of a cementless femoral stem. We conducted a retrospective review of 55 hips in 53 patients using a short proximal fit-and-fill anatomical stem (APS Natural-Hip™ System). All femurs were examined by density mapping which can visualize and digitize the contact state. We evaluated the contact state of implant and femur by using density mapping. The varus group (cases that had changed varus 2° by 3 months after surgery) consisted of 11 hips. The varus group showed no significant difference with regard to cortical contact in the proximal medial portion (Gruen 7), but the contact area in the distal portion (Gruen 3 and Gruen 5) was significantly lower than that of non-varus group. Density mapping showed that the stem only has to be press-fit to the medial calcar, but also must fill the distal portion of the implant in order to achieve the ideal contact state. Our results indicated that quantifying the contact state of implant and femur by using density mapping is a useful technique to accurately analyze the fixation pattern of a cementless femoral stem.
- 5 November 2015
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 25 (8) , 1293-1300
Usefullness of three-dimensional templating software to quantify the contact state between implant and femur in total hip arthroplasty
It would be ideal if surgeons could precisely confirm whether the planned femoral component achieves the best fit and fill of implant and femur. However, the cortico-cancellous interfaces can be difficult to standardize using plain radiography, and therefore, determining the contact state is a subjective decision by the examiner. Few reports have described the use of CT-based three-dimensional templating software to quantify the contact state of stem and femur in detail. The purpose of this study was to use three-dimensional templating software to quantify the implant–femur contact state and develop a technique to analyze the initial fixation pattern of a cementless femoral stem. We conducted a retrospective review of 55 hips in 53 patients using a short proximal fit-and-fill anatomical stem (APS Natural-Hip™ System). All femurs were examined by density mapping which can visualize and digitize the contact state. We evaluated the contact state of implant and femur by using density mapping. The varus group (cases that had changed varus 2° by 3 months after surgery) consisted of 11 hips. The varus group showed no significant difference with regard to cortical contact in the proximal medial portion (Gruen 7), but the contact area in the distal portion (Gruen 3 and Gruen 5) was significantly lower than that of non-varus group. Density mapping showed that the stem only has to be press-fit to the medial calcar, but also must fill the distal portion of the implant in order to achieve the ideal contact state. Our results indicated that quantifying the contact state of implant and femur by using density mapping is a useful technique to accurately analyze the fixation pattern of a cementless femoral stem.