EGEran Gazit

Eran Gazit

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eran Gazit has a total of 82 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mobgap: A State-of-the-Art Python Framework for Reproducible Estimation and Algorithm Validation of Digital Mobility Outcomes from a Single Wearable Device

    by Cameron Kirk, Arne Kuederle, Paolo Tasca, Metin Bicer, Dimitrios Megaritis, Eran Gazit, Tecla Bonci, Anisora Ionescu, Chloe Hinchliffe, Alexandru Stihi, et al.

    Objective, continuous assessment of real-world mobility using wearables has significant potential to transform clinical research and practice, yet the field lacks standardised, open-source tools that enable reproducible algorithm real-world validation, across multiple clinical cohorts. This would improve transparency around definitions and performance, thereby enhancing interpretation and more meaningful comparison across studies. The Mobilise-D consortium validated a comprehensive analytical pipeline for estimating digital mobility outcomes from wearables, originally implemented in a combination of MATLAB, R, and Python codes. To overcome the licencing, reproducibility, and accessibility limitations of this implementation, the pipeline has been re-implemented and re-validated, against gold standards, as the open-source mobgap Python package. Here, we describe the mobgap ecosystem, detail how algorithms can be integrated and benchmarked in a reproducible way and present a re-validation of the pipeline against reference data across six clinical cohorts under real-world conditions. Validation results showed that across all cohorts, walking speed was estimated with an absolute error of 0.10 m/s and an intraclass correlation coefficient (ICC) of 0.81, demonstrating comparable or superior performance to the original implementation. Mobgap (v1.2) is openly available and is intended to serve as a reproducible reference implementation and benchmarking platform for researchers developing or validating mobility analysis algorithms using wearable data.


  • Open Access

    Combining 24-Hour Continuous Monitoring of Time-Locked Heart Rate, Physical Activity and Gait in Older Adults: Preliminary Findings

    by Eitan E. Asher, Eran Gazit, Nasim Montazeri, Elisa Mejía-Mejía, Rachel Godfrey, David A. Bennett, Veronique G. VanderHorst, Aron S. Buchman, Andrew S. P. Lim, Jeffrey M. Hausdorff

    Hemodynamic homeostasis is essential for adapting the heart rate (HR) to postural and physiological changes during daily activities. Traditional HR monitoring, such as 24 hour (h) Holter monitoring, provides important information on homeostasis during daily living. However, this approach lacks concurrent activity recording, limiting insights into hemodynamic adaptation and our ability to interpret changes in HR. To address this, we utilized a novel wearable sensor system (ANNE@Sibel) to capture time-locked HR and daily activity (i.e., lying, sitting, standing, walking) data in 105 community-dwelling older adults. We developed custom tools to extract 24 h time-locked measurements and introduced a “heart rate response score” (HRRS), based on root Jensen–Shannon divergence, to quantify HR changes relative to activity. As expected, we found a progressive HR increase with more vigorous activities, though individual responses varied widely, highlighting heterogeneous HR adaptations. The HRRS (mean: 0.38 ± 0.14; min: −0.11; max: 0.74) summarized person-specific HR changes and was correlated with several clinical measures, including systolic blood pressure changes during postural transitions (r = 0.325, p = 0.003), orthostatic hypotension status, and calcium channel blocker medication use. These findings demonstrate the potential of unobtrusive sensors in remote phenotyping as a means of providing valuable physiological and behavioral data to enhance the quantitative description of aging phenotypes. This approach could enhance personalized medicine by informing targeted interventions based on hemodynamic adaptations during everyday activities.


  • Associations of pain sensitivity and conditioned pain modulation with physical activity: findings from the Multicenter Osteoarthritis Study (MOST)

    by Soyoung Lee, Tuhina Neogi, Brooke McGinley, Na Wang, Laura Frey Law, Kaveh A. Torabian, Kosaku Aoyagi, Joshua J. Stefanik, Lisa C. Carlesso, Jeffrey M. Hausdorff, et al.


  • Open Access

    Discriminating between indoor and outdoor environments during daily living activities using local magnetic field characteristics and machine learning techniques

    by Vincenzo Marcianò, Stefano Bertuletti, Marco Caruso, Tecla Bonci, Lisa Alcock, Eran Gazit, Neil Ireson, Antonio Bevilacqua, Claudia Mazzà, Fabio Ciravegna, et al.

    Wearable technology has rapidly evolved, enabling the integration of various sensors and algorithms, opening new possibilities for context-aware applications in fields such as healthcare, fitness tracking, and environmental monitoring. The discrimination between indoor and outdoor environments is crucial. This is often accomplished through technologies like GPS, Wi-Fi, cellular, and Bluetooth. However, these methods have drawbacks, including privacy concerns, high power consumption, and reliance on external infrastructure. To address these challenges, recent studies have explored using the ambient magnetic field for indoor-outdoor detection, though comprehensive validation with real-life data is lacking. This paper seeks to validate specific machine learning techniques - random forest, extreme gradient boosting, and stacked long short-term memory networks - for indoor-outdoor discrimination. The validation exclusively relies on magnetometer data from the daily activities of 20 participants in four cities across three countries (United Kingdom, Germany, and Italy). The study examines factors such as magnetometer placement (feet, lower back, and non-dominant wrist) and pre-processing techniques (features, window size, etc.). Reference data is obtained through a GPS-based algorithm coupled with a geographical database running on a smartphone carried by the participants. The extreme gradient boosting algorithm yielded the best results, with an accuracy of 0.91, an F1-score of 0.90, and an area under the ROC curve of 0.94. These findings confirm the feasibility of extracting precise indoor/outdoor context information from magnetometer data.


  • Open Access

    A robust walking detection algorithm using a single foot-worn inertial sensor: validation in real-life settings

    by Gaëlle Prigent, Kamiar Aminian, Andrea Cereatti, Francesca Salis, Tecla Bonci, Kirsty Scott, Claudia Mazzà, Lisa Alcock, Silvia Del Din, Eran Gazit, et al.

    Walking activity and gait parameters are considered among the most relevant mobility-related parameters. Currently, gait assessments have been mainly analyzed in laboratory or hospital settings, which only partially reflect usual performance (i.e., real world behavior). In this study, we aim to validate a robust walking detection algorithm using a single foot-worn inertial measurement unit (IMU) in real-life settings. We used a challenging dataset including 18 individuals performing free-living activities. A multi-sensor wearable system including pressure insoles, multiple IMUs, and infrared distance sensors (INDIP) was used as reference. Accurate walking detection was obtained, with sensitivity and specificity of 98 and 91% respectively. As robust walking detection is needed for ambulatory monitoring to complete the processing pipeline from raw recorded data to walking/mobility outcomes, a validated algorithm would pave the way for assessing patient performance and gait quality in real-world conditions. Graphical Abstract


  • Open Access

    Gait Detection from a Wrist-Worn Sensor Using Machine Learning Methods: A Daily Living Study in Older Adults and People with Parkinson’s Disease

    by Yonatan E. Brand, Dafna Schwartz, Eran Gazit, Aron S. Buchman, Ran Gilad-Bachrach, Jeffrey M. Hausdorff

    Remote assessment of the gait of older adults (OAs) during daily living using wrist-worn sensors has the potential to augment clinical care and mobility research. However, hand movements can degrade gait detection from wrist-sensor recordings. To address this challenge, we developed an anomaly detection algorithm and compared its performance to four previously published gait detection algorithms. Multiday accelerometer recordings from a wrist-worn and lower-back sensor (i.e., the “gold-standard” reference) were obtained in 30 OAs, 60% with Parkinson’s disease (PD). The area under the receiver operator curve (AUC) and the area under the precision–recall curve (AUPRC) were used to evaluate the performance of the algorithms. The anomaly detection algorithm obtained AUCs of 0.80 and 0.74 for OAs and PD, respectively, but AUPRCs of 0.23 and 0.31 for OAs and PD, respectively. The best performing detection algorithm, a deep convolutional neural network (DCNN), exhibited high AUCs (i.e., 0.94 for OAs and 0.89 for PD) but lower AUPRCs (i.e., 0.66 for OAs and 0.60 for PD), indicating trade-offs between precision and recall. When choosing a classification threshold of 0.9 (i.e., opting for high precision) for the DCNN algorithm, strong correlations (r > 0.8) were observed between daily living walking time estimates based on the lower-back (reference) sensor and the wrist sensor. Further, gait quality measures were significantly different in OAs and PD compared to healthy adults. These results demonstrate that daily living gait can be quantified using a wrist-worn sensor.


  • Open Access

    A Quality Control Check to Ensure Comparability of Stereophotogrammetric Data between Sessions and Systems

    by Kirsty Scott, Tecla Bonci, Lisa Alcock, Ellen Buckley, Clint Hansen, Eran Gazit, Lars Schwickert, Andrea Cereatti, Claudia Mazzà, on behalf of the Mobilise-D Consortium

    Optoelectronic stereophotogrammetric (SP) systems are widely used in human movement research for clinical diagnostics, interventional applications, and as a reference system for validating alternative technologies. Regardless of the application, SP systems exhibit different random and systematic errors depending on camera specifications, system setup and laboratory environment, which hinders comparing SP data between sessions and across different systems. While many methods have been proposed to quantify and report the errors of SP systems, they are rarely utilized due to their complexity and need for additional equipment. In response, an easy-to-use quality control (QC) check has been designed that can be completed immediately prior to a data collection. This QC check requires minimal training for the operator and no additional equipment. In addition, a custom graphical user interface ensures automatic processing of the errors in an easy-to-read format for immediate interpretation. On initial deployment in a multicentric study, the check (i) proved to be feasible to perform in a short timeframe with minimal burden to the operator, and (ii) quantified the level of random and systematic errors between sessions and systems, ensuring comparability of data in a variety of protocol setups, including repeated measures, longitudinal studies and multicentric studies.


  • Open Access

    Using Wearable Sensors and Machine Learning to Automatically Detect Freezing of Gait during a FOG-Provoking Test

    by Tal Reches, Moria Dagan, Talia Herman, Eran Gazit, Natalia A. Gouskova, Nir Giladi, Brad Manor, Jeffrey M. Hausdorff

    Freezing of gait (FOG) is a debilitating motor phenomenon that is common among individuals with advanced Parkinson’s disease. Objective and sensitive measures are needed to better quantify FOG. The present work addresses this need by leveraging wearable devices and machine-learning methods to develop and evaluate automated detection of FOG and quantification of its severity. Seventy-one subjects with FOG completed a FOG-provoking test while wearing three wearable sensors (lower back and each ankle). Subjects were videotaped before (OFF state) and after (ON state) they took their antiparkinsonian medications. Annotations of the videos provided the “ground-truth” for FOG detection. A leave-one-patient-out validation process with a training set of 57 subjects resulted in 84.1% sensitivity, 83.4% specificity, and 85.0% accuracy for FOG detection. Similar results were seen in an independent test set (data from 14 other subjects). Two derived outcomes, percent time frozen and number of FOG episodes, were associated with self-report of FOG. Both derived-metrics were higher in the OFF state than in the ON state and in the most challenging level of the FOG-provoking test, compared to the least challenging level. These results suggest that this automated machine-learning approach can objectively assess FOG and that its outcomes are responsive to therapeutic interventions.


  • What happens before the first step? A New Approach to Quantifying Gait Initiation Using a Wearable Sensor

    by Eran Gazit, Aron S. Buchman, Robert Dawe, Thomas A. Curran, Anat Mirelman, Nir Giladi, Jeffrey M. Hausdorff


  • Changes in event-related potentials during dual task walking in aging and Parkinson's disease

    by Inbal Maidan, Firas Fahoum, Shiran Shustak, Eran Gazit, Dmitry Patashov, Dmitry Tchertov, Nir Giladi, Jeffrey M Hausdorff, Anat Mirelman