Ilie Dumitru
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ilie Dumitru has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
D Tutunea
Faculty of Mechanics, University of Craiova, România
4 shared publicationsL D Racila
Faculty of Mechanics, University of Craiova, România
4 shared publicationsL Matei
Faculty of Mechanics, University of Craiova, România
4 shared publicationsM Racila
Department of Applied Mathematics, University of Craiova, Romania
4 shared publicationsO Otat
Faculty of Mechanics, University of Craiova, România
4 shared publications- Laurentiu Racila
University of Craiova
3 shared publications
Latest Publications
- 20 November 2024
- Published by Springer Nature
- p. 38-49
Traffic Flow Investigation of an Adaptive Signal Control System in Several Junctions
- 20 November 2024
- Published by Springer Nature
- p. 38-49
Traffic Flow Investigation of an Adaptive Signal Control System in Several Junctions
- Open Access
- 7 October 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (10) , 1002
Assessment of Thermal Influence on an Orthodontic System by Means of the Finite Element Method
The development of the finite element method (FEM) combined block polynomial interpolation with the concepts of finite difference formats and the variation principle. Because of this combination, the FEM overcomes the shortcomings of traditional variation methods while maintaining the benefits of current variation methods and the flexibility of the finite difference method. As a result, the FEM is an advancement above the traditional variation methods. The purpose of this study is to experimentally highlight the thermal behavior of two stomatognathic systems, one a control and the other presenting orthodontic treatment by means of a fixed metallic orthodontic appliance, both being subjected to several thermal regimes. In order to sustain this experimental research, we examined the case of a female subject, who was diagnosed with Angle class I malocclusion. The patient underwent a bimaxillary CBCT investigation before initiating the orthodontic treatment. A three-dimensional model with fully closed surfaces was obtained by using the InVesalius and Geomagic programs. Like the tissues examined in the patient, bracket and tube-type elements as well as orthodontic wires can be included to the virtual models. Once it is finished and geometrically accurate, the model is exported to an FEM-using program, such as Ansys Workbench. The intention was to study the behavior of two stomatognathic systems (with and without a fixed metallic orthodontic appliance) subjected to very hot food (70 °C) and very cold food (−18 °C). From the analysis of the obtained data, it was concluded that, following the simulations carried out in the presence of the fixed metallic orthodontic appliance, significantly higher temperatures were generated in the dental pulp.
- 7 October 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (10) , 1002
Open AccessAssessment of Thermal Influence on an Orthodontic System by Means of the Finite Element Method
The development of the finite element method (FEM) combined block polynomial interpolation with the concepts of finite difference formats and the variation principle. Because of this combination, the FEM overcomes the shortcomings of traditional variation methods while maintaining the benefits of current variation methods and the flexibility of the finite difference method. As a result, the FEM is an advancement above the traditional variation methods. The purpose of this study is to experimentally highlight the thermal behavior of two stomatognathic systems, one a control and the other presenting orthodontic treatment by means of a fixed metallic orthodontic appliance, both being subjected to several thermal regimes. In order to sustain this experimental research, we examined the case of a female subject, who was diagnosed with Angle class I malocclusion. The patient underwent a bimaxillary CBCT investigation before initiating the orthodontic treatment. A three-dimensional model with fully closed surfaces was obtained by using the InVesalius and Geomagic programs. Like the tissues examined in the patient, bracket and tube-type elements as well as orthodontic wires can be included to the virtual models. Once it is finished and geometrically accurate, the model is exported to an FEM-using program, such as Ansys Workbench. The intention was to study the behavior of two stomatognathic systems (with and without a fixed metallic orthodontic appliance) subjected to very hot food (70 °C) and very cold food (−18 °C). From the analysis of the obtained data, it was concluded that, following the simulations carried out in the presence of the fixed metallic orthodontic appliance, significantly higher temperatures were generated in the dental pulp.
- Open Access
- 11 September 2024
- Published by MDPI AG in Preprints.org
Assessment of Thermal Influence on an Orthodontic System by Means of the Finite Element Method
The development of the finite element method (FEM) combined block polynomial interpolation with the concepts of finite difference formats and the variation principle. Because of this combination, FEM overcomes the shortcomings of traditional variation methods while maintaining the benefits of current variation methods and the flexibility of the finite difference method. As a result, FEM is an advancement above the traditional variation methods. The aim of the study is to experimentally determine the thermal behavior of two stomatognathic systems, one control and the other presenting orthodontic treatment by means of a fixed metallic orthodontic appliance, both being subjected to several thermal regimes. In order to carry out this experimental study, we examined the case of a female subject, who was diagnosed with Angle class I malocclusion. The patient underwent a bimaxillary CBCT investigation before initiating the orthodontic treatment. A three-dimensional model with fully closed surfaces was obtained by using the InVesalius and Geomagic programs. Like the tissues examined in the patient, bracket and tube-like components, as well as orthodontic wires, can be included to these models. Once it is finished and geometrically accurate, the model is exported to a FEM-using program, such as Ansys Workbench. The intention was to study the behavior of two stomatognathic systems (with and without a fixed metallic orthodontic appliance) subjected to very hot food (70 ⁰C) and very cold food (-18 ⁰C). From the analysis of the obtained data, it was concluded that, following the simulations carried out in the presence of the fixed metallic orthodontic appliance, significantly higher temperatures were generated in the dental pulp.
- 11 September 2024
- Published by MDPI AG in Preprints.org
Open AccessAssessment of Thermal Influence on an Orthodontic System by Means of the Finite Element Method
The development of the finite element method (FEM) combined block polynomial interpolation with the concepts of finite difference formats and the variation principle. Because of this combination, FEM overcomes the shortcomings of traditional variation methods while maintaining the benefits of current variation methods and the flexibility of the finite difference method. As a result, FEM is an advancement above the traditional variation methods. The aim of the study is to experimentally determine the thermal behavior of two stomatognathic systems, one control and the other presenting orthodontic treatment by means of a fixed metallic orthodontic appliance, both being subjected to several thermal regimes. In order to carry out this experimental study, we examined the case of a female subject, who was diagnosed with Angle class I malocclusion. The patient underwent a bimaxillary CBCT investigation before initiating the orthodontic treatment. A three-dimensional model with fully closed surfaces was obtained by using the InVesalius and Geomagic programs. Like the tissues examined in the patient, bracket and tube-like components, as well as orthodontic wires, can be included to these models. Once it is finished and geometrically accurate, the model is exported to a FEM-using program, such as Ansys Workbench. The intention was to study the behavior of two stomatognathic systems (with and without a fixed metallic orthodontic appliance) subjected to very hot food (70 ⁰C) and very cold food (-18 ⁰C). From the analysis of the obtained data, it was concluded that, following the simulations carried out in the presence of the fixed metallic orthodontic appliance, significantly higher temperatures were generated in the dental pulp.
- Open Access
- 31 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (7) , 4156
Reducing NOx Emissions through Microwave Heating of Aftertreatment Systems for Sustainable Transport in the Inland Waterway Sector
The inland navigation sector makes a significant contribution to the growth of the global economy as well as to climate change due to pollutants emitted by diesel engines. NOx emissions are very high in port areas where, due to traffic, the ships run at idling regimes. Selective catalytic reduction (SCR) represents one of the most suitable technologies, in terms of cost effectiveness, but does not perform well if the temperature during vessel operation is lower than 180 °C. Microwave technology can support preheating of the ceramic core of SCR in order to increase the temperature towards the optimal interval for the best NOx reduction. Research has focused on coupling a magnetron head to a SCR device in order to evaluate to what extent the technology can meet the requirements of Stage V of the European Directive related to NOx emissions. Measurements of NOx emitted have been performed on engines with 603.5 kW nominal power and 1500 rpm that operate at a lower engine speed (700–1200 rpm) and output power (58–418 kW). The values recorded for emissions using microwave heating of ceramic core of SCR have decreased by 89% for a constant load of engine and idling engine speed.
- 31 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (7) , 4156
Open AccessReducing NOx Emissions through Microwave Heating of Aftertreatment Systems for Sustainable Transport in the Inland Waterway Sector
The inland navigation sector makes a significant contribution to the growth of the global economy as well as to climate change due to pollutants emitted by diesel engines. NOx emissions are very high in port areas where, due to traffic, the ships run at idling regimes. Selective catalytic reduction (SCR) represents one of the most suitable technologies, in terms of cost effectiveness, but does not perform well if the temperature during vessel operation is lower than 180 °C. Microwave technology can support preheating of the ceramic core of SCR in order to increase the temperature towards the optimal interval for the best NOx reduction. Research has focused on coupling a magnetron head to a SCR device in order to evaluate to what extent the technology can meet the requirements of Stage V of the European Directive related to NOx emissions. Measurements of NOx emitted have been performed on engines with 603.5 kW nominal power and 1500 rpm that operate at a lower engine speed (700–1200 rpm) and output power (58–418 kW). The values recorded for emissions using microwave heating of ceramic core of SCR have decreased by 89% for a constant load of engine and idling engine speed.
- Open Access
- 28 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 262
Reconfigurable/Foldable Overconstrained Mechanism and Its Application
The paper presents some possible applications started from a six revolute joints (6R) overconstrained mechanism. The spatial devices obtained are based on the 6R Wohlhart symmetric mechanism in a special spatial position, with three non-adjacent joints constrained to remain in a fixed plane. This special spatial disposition allows us to obtain some reconfigurable/foldable devices, with an estimated application in the automotive industry field.
- 28 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 12 (1) , 262
Open AccessReconfigurable/Foldable Overconstrained Mechanism and Its Application
The paper presents some possible applications started from a six revolute joints (6R) overconstrained mechanism. The spatial devices obtained are based on the 6R Wohlhart symmetric mechanism in a special spatial position, with three non-adjacent joints constrained to remain in a fixed plane. This special spatial disposition allows us to obtain some reconfigurable/foldable devices, with an estimated application in the automotive industry field.
- Open Access
Microwave Technology Using Low Energy Concentrated Beam for Processing of Solid Waste Materials from Rapana thomasiana Seashells
The solid waste of Rapana thomasiana seashells both from domestic activities and natural waste on seashore can be used to obtain viable products for medical applications. However, conventional technologies applied for sintering the materials require massive energy consumption due to the resistance heating. Microwave heating represents an advanced technology for sintering, but the stability of the process, in terms of thermal runaway and microwave plasma arc discharge, jeopardizes the quality of the sintered products. This paper aims to present the results of research focused on viable heating technology and the mechanical properties of the final products. A comparative analysis, in terms of energy efficiency vs. mechanical properties, has been performed for three different heating technologies: direct microwave heating, hybrid microwave heating and resistance heating. The results obtained concluded that the hybrid microwave heating led to final products from Rapana thomasiana solid waste with similar mechanical properties compared with resistance heating. In terms of energy efficiency, the hybrid microwave heating was 20 times better than resistance heating.
Open AccessMicrowave Technology Using Low Energy Concentrated Beam for Processing of Solid Waste Materials from Rapana thomasiana Seashells
The solid waste of Rapana thomasiana seashells both from domestic activities and natural waste on seashore can be used to obtain viable products for medical applications. However, conventional technologies applied for sintering the materials require massive energy consumption due to the resistance heating. Microwave heating represents an advanced technology for sintering, but the stability of the process, in terms of thermal runaway and microwave plasma arc discharge, jeopardizes the quality of the sintered products. This paper aims to present the results of research focused on viable heating technology and the mechanical properties of the final products. A comparative analysis, in terms of energy efficiency vs. mechanical properties, has been performed for three different heating technologies: direct microwave heating, hybrid microwave heating and resistance heating. The results obtained concluded that the hybrid microwave heating led to final products from Rapana thomasiana solid waste with similar mechanical properties compared with resistance heating. In terms of energy efficiency, the hybrid microwave heating was 20 times better than resistance heating.
- 14 October 2019
- Published by Springer Nature
- p. 607-613
Solicitations in the Rear Axle Support of a Karting Frame
- 14 October 2019
- Published by Springer Nature
- p. 607-613
Solicitations in the Rear Axle Support of a Karting Frame
- 14 October 2019
- Published by Springer Nature
- p. 636-642
Construction of a Kart Chassis Through 3D Reconstruction Methods – Part 1 – Scanning and Alignment
- 14 October 2019
- Published by Springer Nature
- p. 636-642
Construction of a Kart Chassis Through 3D Reconstruction Methods – Part 1 – Scanning and Alignment
- Open Access
- 1 August 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 568 (1) , 012004
Focusing device based on overconstrained mechanism
The paper presents an application based on a very special 6R overconstrained mechanism. This mechanism is started from 6R Wohlhart symmetric mechanism, not in its classical spatial position but in a different one, with three non-adjacent joints constrained to remain in a fixed plane. This disposition allows the conception of an interesting device, a focusing table, capable to obtain a good accuracy.
- 1 August 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 568 (1) , 012004
Open AccessFocusing device based on overconstrained mechanism
The paper presents an application based on a very special 6R overconstrained mechanism. This mechanism is started from 6R Wohlhart symmetric mechanism, not in its classical spatial position but in a different one, with three non-adjacent joints constrained to remain in a fixed plane. This disposition allows the conception of an interesting device, a focusing table, capable to obtain a good accuracy.
- Open Access
- 1 August 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 568 (1) , 012085
Focusing Device Based on Overconstrained Mechanism
The paper presents an application based on an exceptional 6R overconstrained mechanism. This mechanism is started from 6R Wohlhart symmetric mechanism, not in its classical spatial position but a different one, with three non-adjacent joints constrained to remain in a fixed plane. This disposition allows the conception of an interesting device, a focusing table, capable of obtaining good accuracy.
- 1 August 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 568 (1) , 012085
Open AccessFocusing Device Based on Overconstrained Mechanism
The paper presents an application based on an exceptional 6R overconstrained mechanism. This mechanism is started from 6R Wohlhart symmetric mechanism, not in its classical spatial position but a different one, with three non-adjacent joints constrained to remain in a fixed plane. This disposition allows the conception of an interesting device, a focusing table, capable of obtaining good accuracy.