Danny Santoso Mintorogo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Danny Santoso Mintorogo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Anik Juniwati
Fakultas Teknik Sipil dan Perencanaan Fakultas Teknik Sipil dan Perencanaan Teknik Mesin Fakultas Teknik Industri di Surabaya. Hasil penelitian menunjukkan bahwa EAHE Universitas Kristen Petra Surabaya Universitas Kristen Petra Surabaya Universitas Kristen Petra Surabaya
4 shared publications- Wanda K. Widigdo
Department of Architecture, Petra Christian University, Jalan Siwalankerto 121-131, Surabaya 60235, East-Java, Indonesia
2 shared publications - Aris Budhiyanto
Department of Architecture, Petra Christian University, Surabaya, Indonesia
1 shared publication - Ekadewi Anggraini Handoyo
Petra Christian University
1 shared publication Fandi D. Suprianto
Department of Mechanical Engineering, Petra Christian University, East-Java, Indonesia
1 shared publication- Feny Elsiana
Department of Architecture, Petra Christian University, Surabaya, Indonesia
1 shared publication
Latest Publications
- Open Access
- 1 February 2025
- Published by LPPM ITN Malang in Pawon: Jurnal Arsitektur
- Vol. 9 (01) , 141-150
OPTIMASI EAHE SEBAGAI UPAYA PENDINGIN RUANG SIANG HARI DI SURABAYA
ABSTRAK Tinggal dan beraktifitas dalam lingkungan bersuhu tinggi di iklim tropis lembab meningkatkan risiko dehidrasi, menurunkan konsentrasi, kelelahan, menimbulkan masalah kesehatan dan menurunkan produktivitas. Upaya pendinginan pasif dengan ventilasi alami sering kali tidak efektif karena suhu tinggi, kelembaban, radiasi matahari, serta kecepatan angin yang tidak mendukung. Sedang meningkatkan kecepatan angin akan mengganggu aktifitas. Salah satu solusi untuk pendinginan adalah dengan memindahkan panas udara ke tanah, atau dikenal sebagai Earth-to-Air Heat Exchanger (EAHE). Penelitian ini merupakan eksperimental studi lanjutan untuk mendapatkan optimasi model EAHE di siang hari di Surabaya. Hasilnya menunjukkan bahwa EAHE efektif menurunkan suhu ruang hingga 2ºC. Angka ini cukup signifikan untuk dipakai sebagai pendinginan ruang. Kajian lebih lanjut diperlukan untuk menentukan kebutuhan udara dingin yang proporsional dengan volume ruang. Kata kunci: Kenyamanan Termal, Ventilasi, Pendinginan Udara, EAHE ABSTRACT People living and working in high-temperature environments are prone to dehydration, reduced concentration, and fatigue, leading to health issues and decreased productivity. Passive cooling through natural ventilation is often ineffective in humid tropical cities due to high temperatures, humidity, and low wind speeds, while high wind speeds can disrupt activities. Earth-to-Air Heat Exchanger (EAHE) systems provide a cooling solution by transferring air heat to the ground. This experimental study on ventilation using EAHE is an optimization EAHE model on daytime in Surabaya. The result showed that EAHE reduced room temperatures by up to 2ºC during the day. This confirms EAHE’s potential for cooling applications. Further research is needed to optimize the required air volume for effective space cooling. Keywords: Thermal comfort, ventilation, air-cooling, EAHE
- 1 February 2025
- Published by LPPM ITN Malang in Pawon: Jurnal Arsitektur
- Vol. 9 (01) , 141-150
Open AccessOPTIMASI EAHE SEBAGAI UPAYA PENDINGIN RUANG SIANG HARI DI SURABAYA
ABSTRAK Tinggal dan beraktifitas dalam lingkungan bersuhu tinggi di iklim tropis lembab meningkatkan risiko dehidrasi, menurunkan konsentrasi, kelelahan, menimbulkan masalah kesehatan dan menurunkan produktivitas. Upaya pendinginan pasif dengan ventilasi alami sering kali tidak efektif karena suhu tinggi, kelembaban, radiasi matahari, serta kecepatan angin yang tidak mendukung. Sedang meningkatkan kecepatan angin akan mengganggu aktifitas. Salah satu solusi untuk pendinginan adalah dengan memindahkan panas udara ke tanah, atau dikenal sebagai Earth-to-Air Heat Exchanger (EAHE). Penelitian ini merupakan eksperimental studi lanjutan untuk mendapatkan optimasi model EAHE di siang hari di Surabaya. Hasilnya menunjukkan bahwa EAHE efektif menurunkan suhu ruang hingga 2ºC. Angka ini cukup signifikan untuk dipakai sebagai pendinginan ruang. Kajian lebih lanjut diperlukan untuk menentukan kebutuhan udara dingin yang proporsional dengan volume ruang. Kata kunci: Kenyamanan Termal, Ventilasi, Pendinginan Udara, EAHE ABSTRACT People living and working in high-temperature environments are prone to dehydration, reduced concentration, and fatigue, leading to health issues and decreased productivity. Passive cooling through natural ventilation is often ineffective in humid tropical cities due to high temperatures, humidity, and low wind speeds, while high wind speeds can disrupt activities. Earth-to-Air Heat Exchanger (EAHE) systems provide a cooling solution by transferring air heat to the ground. This experimental study on ventilation using EAHE is an optimization EAHE model on daytime in Surabaya. The result showed that EAHE reduced room temperatures by up to 2ºC during the day. This confirms EAHE’s potential for cooling applications. Further research is needed to optimize the required air volume for effective space cooling. Keywords: Thermal comfort, ventilation, air-cooling, EAHE
- Open Access
- 12 September 2022
- Published by Petra Christian University in Advances in Civil Engineering and Sustainable Architecture
- Vol. 4 (2) , 91-99
PARAMETER DESAIN UNTUK MODUL GREEN FAÇADE BANGUNAN VERTIKAL YANG MEMUDAHKAN PEMASANGAN DAN PERAWATAN
PARAMETER DESAIN UNTUK MODUL GREEN FAÇADE BANGUNAN VERTIKAL YANG MEMUDAHKAN PEMASANGAN DAN PERAWATAN
- 12 September 2022
- Published by Petra Christian University in Advances in Civil Engineering and Sustainable Architecture
- Vol. 4 (2) , 91-99
Open AccessPARAMETER DESAIN UNTUK MODUL GREEN FAÇADE BANGUNAN VERTIKAL YANG MEMUDAHKAN PEMASANGAN DAN PERAWATAN
PARAMETER DESAIN UNTUK MODUL GREEN FAÇADE BANGUNAN VERTIKAL YANG MEMUDAHKAN PEMASANGAN DAN PERAWATAN
- Open Access
- 15 February 2022
- Published by Taylor & Francis in Journal of Asian Architecture and Building Engineering
- Vol. 21 (6) , 2593-2604
Harvesting renewable energies through innovative kinetic honeycomb architectural facades: the mathematical & CFD modeling for wind turbine design optimization
The research was specifically focused on the renewable energy factors associated with thousands of hexagonal micro-module wind turbines, hexagonal solar cell modules, and hexagonal modules for solar-reflecting pipes. This involved the utilization of windmills and solar cells specifically designed in a non-structural facade of the front building envelope through a double facade technique. Moreover, electrical energy was obtained from each windmill module while extra renewable electricity from abundant sunlight was acquired through the hexagonal modules of the solar cells (photovoltaic) designed vertically on the building facade. But this current research only focuses on hexagonal wind turbines. ANSYS Fluent 12.0 simulated software and numerical analysis were used to optimize and redesign the wind turbine blades in order to obtain more electricity from one micro-module hexagonal wind turbine. The results showed that this design was able to produce 2.66 Watts per wind turbine compared to the 0.12 Watt from the previous design. The TSR was also found to be 0.5 and its power coefficient value (CP) of 0.4525 was observed to be much higher than the 0.0343 from the previous design. Therefore, means multilevel buildings have the ability to harvest sustainable greenery energies from such a smart architectural façade.
- 15 February 2022
- Published by Taylor & Francis in Journal of Asian Architecture and Building Engineering
- Vol. 21 (6) , 2593-2604
Open AccessHarvesting renewable energies through innovative kinetic honeycomb architectural facades: the mathematical & CFD modeling for wind turbine design optimization
The research was specifically focused on the renewable energy factors associated with thousands of hexagonal micro-module wind turbines, hexagonal solar cell modules, and hexagonal modules for solar-reflecting pipes. This involved the utilization of windmills and solar cells specifically designed in a non-structural facade of the front building envelope through a double facade technique. Moreover, electrical energy was obtained from each windmill module while extra renewable electricity from abundant sunlight was acquired through the hexagonal modules of the solar cells (photovoltaic) designed vertically on the building facade. But this current research only focuses on hexagonal wind turbines. ANSYS Fluent 12.0 simulated software and numerical analysis were used to optimize and redesign the wind turbine blades in order to obtain more electricity from one micro-module hexagonal wind turbine. The results showed that this design was able to produce 2.66 Watts per wind turbine compared to the 0.12 Watt from the previous design. The TSR was also found to be 0.5 and its power coefficient value (CP) of 0.4525 was observed to be much higher than the 0.0343 from the previous design. Therefore, means multilevel buildings have the ability to harvest sustainable greenery energies from such a smart architectural façade.
- Open Access
- 28 February 2020
- Published by Petra Christian University in DIMENSI: Journal of Architecture and Built Environment
- Vol. 46 (2) , 155-160
PUMICE LAYER: A SOLUTION TO DIMINISH THERMAL ON HORIZONTAL LEFTOVER PLACE IN ROOFTOP
There are many ways to solve thermal on buildings, such as the installation of horizontal and vertical sun-shading devices on four-direction facades. However, rooftops are often ignored. In low-rise to high-rise buildings’ rooftop, there are leftover places exposed to solar heat radiation all day. Some rooftop places are equipped with polymer thermal roof insulation, and some are even without outer thermal insulation. The research aims to find a solution to diminish the horizontal thermal radiation by using eco-friendly material, pumice, as an outer thermal insulation. Exploiting method was used on one roof model as a conventional rooftop (without outer insulation), and another as a modified rooftop model covered with pumice. Couple HOBO data logger U12-012 temperature sensors were used to measure rooftop surface temperatures and room model temperatures. Results show that the thermal radiation were blocked efficiently: 26oC on pumice covered rooftop. It saved 8.4oC room temperature.
- 28 February 2020
- Published by Petra Christian University in DIMENSI: Journal of Architecture and Built Environment
- Vol. 46 (2) , 155-160
Open AccessPUMICE LAYER: A SOLUTION TO DIMINISH THERMAL ON HORIZONTAL LEFTOVER PLACE IN ROOFTOP
There are many ways to solve thermal on buildings, such as the installation of horizontal and vertical sun-shading devices on four-direction facades. However, rooftops are often ignored. In low-rise to high-rise buildings’ rooftop, there are leftover places exposed to solar heat radiation all day. Some rooftop places are equipped with polymer thermal roof insulation, and some are even without outer thermal insulation. The research aims to find a solution to diminish the horizontal thermal radiation by using eco-friendly material, pumice, as an outer thermal insulation. Exploiting method was used on one roof model as a conventional rooftop (without outer insulation), and another as a modified rooftop model covered with pumice. Couple HOBO data logger U12-012 temperature sensors were used to measure rooftop surface temperatures and room model temperatures. Results show that the thermal radiation were blocked efficiently: 26oC on pumice covered rooftop. It saved 8.4oC room temperature.
- 1 July 2017
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 23 (7) , 6173-6178
Remarkable 3-in-1 Pakis-Stem Green Roofs for Saving Thermal Flat Rooftop
The green councils in the world are often promoting green buildings in terms of energy savings by mitigating the thermal load on buildings especially thermal rooftop into the room. Green roofs can be the most effective to lower roof thermal in tropical regions but complicated and costly to build a perfect green roof even for a simple extensive green rooftop. This research looks for a remarkable growing medium for constructing green roof. Pakis-stem blocks can perform a 3 in 1 function: as a light-weight growing medium for green rooftops, an easytoform urban farming in private buildings or residences, and an eco-friendly external roof insulation. After a deep measurement on the rooftop surface and room thermal behaviour, the pakis-stem green rooftop can reduce 16.4 °C of surface dry-bulk temperature and approximately 7 °C ambient room dry-bulk temperature lower compared to conventional rooftops at noon. Furthermore, the surface temperature and ambient room air temperature difference between Pakis vegetative green rooftops and miana scrub green rooftop is approximately 7 °C and 3 °C respectively.
- 1 July 2017
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 23 (7) , 6173-6178
Remarkable 3-in-1 Pakis-Stem Green Roofs for Saving Thermal Flat Rooftop
The green councils in the world are often promoting green buildings in terms of energy savings by mitigating the thermal load on buildings especially thermal rooftop into the room. Green roofs can be the most effective to lower roof thermal in tropical regions but complicated and costly to build a perfect green roof even for a simple extensive green rooftop. This research looks for a remarkable growing medium for constructing green roof. Pakis-stem blocks can perform a 3 in 1 function: as a light-weight growing medium for green rooftops, an easytoform urban farming in private buildings or residences, and an eco-friendly external roof insulation. After a deep measurement on the rooftop surface and room thermal behaviour, the pakis-stem green rooftop can reduce 16.4 °C of surface dry-bulk temperature and approximately 7 °C ambient room dry-bulk temperature lower compared to conventional rooftops at noon. Furthermore, the surface temperature and ambient room air temperature difference between Pakis vegetative green rooftops and miana scrub green rooftop is approximately 7 °C and 3 °C respectively.
- 1 January 2017
- Published by AIP Publishing
The value of corridor in flat as place attachment in the life of the dwellers
Place attachment has been examined extensively in the behavioral and architecture studies over the past two decades. In the production of housing, designers mainly focus on the quality of the physical components. Place attachment is just the form of connection between a person and the environmental setting. However, it was challenging for this study to grasp the aspects of meanings and attachment, both in the level of personal, community and natural environment contexts, which are not adequately considered in the design process. In this study, three-dimensional model of personal and community attachments to their corridor in the flat was conceptually and empirically examined. The aim is to test an integrated approach to measuring place attachment at the corridor in flat in understanding the values of locations in the life of the dwellers. Sample cases included the examination of attachment to the hallway in three units located in Surabaya, Indonesia. It found out that the value of corridor as a place was affected by the daily experience of the places, social bonding, neighborhood interaction, and landscape values.
- 1 January 2017
- Published by AIP Publishing
The value of corridor in flat as place attachment in the life of the dwellers
Place attachment has been examined extensively in the behavioral and architecture studies over the past two decades. In the production of housing, designers mainly focus on the quality of the physical components. Place attachment is just the form of connection between a person and the environmental setting. However, it was challenging for this study to grasp the aspects of meanings and attachment, both in the level of personal, community and natural environment contexts, which are not adequately considered in the design process. In this study, three-dimensional model of personal and community attachments to their corridor in the flat was conceptually and empirically examined. The aim is to test an integrated approach to measuring place attachment at the corridor in flat in understanding the values of locations in the life of the dwellers. Sample cases included the examination of attachment to the hallway in three units located in Surabaya, Indonesia. It found out that the value of corridor as a place was affected by the daily experience of the places, social bonding, neighborhood interaction, and landscape values.